Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Sports Biomech ; 16(3): 342-360, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28523981

RESUMO

Lunges are a common, compound lower limb resistance exercise. If completed with aberrant technique, the increased stress on the joints used may increase risk of injury. This study sought to first investigate the ability of inertial measurement units (IMUs), when used in isolation and combination, to (a) classify acceptable and aberrant lunge technique (b) classify exact deviations in lunge technique. We then sought to investigate the most important features and establish the minimum number of top-ranked features and decision trees that are needed to maintain maximal system classification efficacy. Eighty volunteers performed the lunge with acceptable form and 11 deviations. Five IMUs positioned on the lumbar spine, thighs, and shanks recorded these movements. Time and frequency domain features were extracted from the IMU data and used to train and test a variety of classifiers. A single-IMU system achieved 83% accuracy, 62% sensitivity, and 90% specificity in binary classification and a five-IMU system achieved 90% accuracy, 80% sensitivity, and 92% specificity. A five-IMU set-up can also detect specific deviations with 70% accuracy. System efficiency was improved and classification quality was maintained when using only 20% of the top-ranked features for training and testing classifiers.


Assuntos
Acelerometria/métodos , Extremidade Inferior/fisiologia , Acelerometria/instrumentação , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Movimento , Estudos de Tempo e Movimento , Adulto Jovem
2.
J Biomech ; 58: 155-161, 2017 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-28545824

RESUMO

The deadlift is a compound full-body exercise that is fundamental in resistance training, rehabilitation programs and powerlifting competitions. Accurate quantification of deadlift biomechanics is important to reduce the risk of injury and ensure training and rehabilitation goals are achieved. This study sought to develop and evaluate deadlift exercise technique classification systems utilising Inertial Measurement Units (IMUs), recording at 51.2Hz, worn on the lumbar spine, both thighs and both shanks. It also sought to compare classification quality when these IMUs are worn in combination and in isolation. Two datasets of IMU deadlift data were collected. Eighty participants first completed deadlifts with acceptable technique and 5 distinct, deliberately induced deviations from acceptable form. Fifty-five members of this group also completed a fatiguing protocol (3-Repition Maximum test) to enable the collection of natural deadlift deviations. For both datasets, universal and personalised random-forests classifiers were developed and evaluated. Personalised classifiers outperformed universal classifiers in accuracy, sensitivity and specificity in the binary classification of acceptable or aberrant technique and in the multi-label classification of specific deadlift deviations. Whilst recent research has favoured universal classifiers due to the reduced overhead in setting them up for new system users, this work demonstrates that such techniques may not be appropriate for classifying deadlift technique due to the poor accuracy achieved. However, personalised classifiers perform very well in assessing deadlift technique, even when using data derived from a single lumbar-worn IMU to detect specific naturally occurring technique mistakes.


Assuntos
Exercício Físico/fisiologia , Vértebras Lombares/fisiologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Adulto Jovem
3.
Methods Inf Med ; 56(5): 361-369, 2017 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-28612890

RESUMO

BACKGROUND: The barbell squat is a popularly used lower limb rehabilitation exercise. It is also an integral exercise in injury risk screening protocols. To date athlete/patient technique has been assessed using expensive laboratory equipment or subjective clinical judgement; both of which are not without shortcomings. Inertial measurement units (IMUs) may offer a low cost solution for the objective evaluation of athlete/patient technique. However, it is not yet known if global classification techniques are effective in identifying naturally occurring, minor deviations in barbell squat technique. OBJECTIVES: The aims of this study were to: (a) determine if in combination or in isolation, IMUs positioned on the lumbar spine, thigh and shank are capable of distinguishing between acceptable and aberrant barbell squat technique; (b) determine the capabilities of an IMU system at identifying specific natural deviations from acceptable barbell squat technique; and (c) compare a personalised (N=1) classifier to a global classifier in identifying the above. METHODS: Fifty-five healthy volunteers (37 males, 18 females, age = 24.21 +/- 5.25 years, height = 1.75 +/- 0.1 m, body mass = 75.09 +/- 13.56 kg) participated in the study. All participants performed a barbell squat 3-repetition maximum max strength test. IMUs were positioned on participants' lumbar spine, both shanks and both thighs; these were utilized to record tri-axial accelerometer, gyroscope and magnetometer data during all repetitions of the barbell squat exercise. Technique was assessed and labelled by a Chartered Physiotherapist using an evaluation framework. Features were extracted from the labelled IMU data. These features were used to train and evaluate both global and personalised random forests classifiers. RESULTS: Global classification techniques produced poor accuracy (AC), sensitivity (SE) and specificity (SP) scores in binary classification even with a 5 IMU set-up in both binary (AC: 64%, SE: 70%, SP: 28%) and multi-class classification (AC: 59%, SE: 24%, SP: 84%). However, utilising personalised classification techniques even with a single IMU positioned on the left thigh produced good binary classification scores (AC: 81%, SE: 81%, SP: 84%) and moderate-to-good multi-class scores (AC: 69%, SE: 70%, SP: 89%). CONCLUSIONS: There are a number of challenges in developing global classification exercise technique evaluation systems for rehabilitation exercises such as the barbell squat. Building large, balanced data sets to train such systems is difficult and time intensive. Minor, naturally occurring deviations may not be detected utilising global classification approaches. Personalised classification approaches allow for higher accuracy and greater system efficiency for end-users in detecting naturally occurring barbell squat technique deviations. Applying this approach also allows for a single-IMU set up to achieve similar accuracy to a multi-IMU setup, which reduces total system cost and maximises system usability.


Assuntos
Tecnologia Biomédica , Exercício Físico/fisiologia , Reabilitação/métodos , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Curva ROC , Adulto Jovem
4.
Methods Inf Med ; 56(2): 88-94, 2017 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-27782290

RESUMO

BACKGROUND: The single leg squat (SLS) is a common lower limb rehabilitation exercise. It is also frequently used as an evaluative exercise to screen for an increased risk of lower limb injury. To date athlete / patient SLS technique has been assessed using expensive laboratory equipment or subjective clinical judgement; both of which are not without shortcomings. Inertial measurement units (IMUs) may offer a low cost solution for the objective evaluation of athlete / patient SLS technique. OBJECTIVES: The aims of this study were to determine if in combination or in isolation IMUs positioned on the lumbar spine, thigh and shank are capable of: (a) distinguishing between acceptable and aberrant SLS technique; (b) identifying specific deviations from acceptable SLS technique. METHODS: Eighty-three healthy volunteers participated (60 males, 23 females, age: 24.68 + / - 4.91 years, height: 1.75 + / - 0.09 m, body mass: 76.01 + / - 13.29 kg). All participants performed 10 SLSs on their left leg. IMUs were positioned on participants' lumbar spine, left shank and left thigh. These were utilized to record tri-axial accelerometer, gyroscope and magnetometer data during all repetitions of the SLS. SLS technique was labelled by a Chartered Physiotherapist using an evaluation framework. Features were extracted from the labelled sensor data. These features were used to train and evaluate a variety of random-forests classifiers that assessed SLS technique. RESULTS: A three IMU system was moderately successful in detecting the overall quality of SLS performance (77 % accuracy, 77 % sensitivity and 78 % specificity). A single IMU worn on the shank can complete the same analysis with 76 % accuracy, 75 % sensitivity and 76 % specificity. Single sensors also produce competitive classification scores relative to multi-sensor systems in identifying specific deviations from acceptable SLS technique. CONCLUSIONS: A single IMU positioned on the shank can differentiate between acceptable and aberrant SLS technique with moderate levels of accuracy. It can also capably identify specific deviations from optimal SLS performance. IMUs may offer a low cost solution for the objective evaluation of SLS performance. Additionally, the classifiers described may provide useful input to an exercise biofeedback application.


Assuntos
Tecnologia Biomédica/métodos , Terapia por Exercício/instrumentação , Perna (Membro)/fisiopatologia , Postura/fisiologia , Reabilitação/métodos , Adulto , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA