Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmology ; 128(4): 554-560, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32941962

RESUMO

PURPOSE: To determine the relationship between refractive error and diabetic retinopathy (DR). DESIGN: Clinical trial. PARTICIPANTS: Type I diabetes individuals with serial refractive error and DR stage measurements over 30 years in the Diabetes Control and Complications Trial (DCCT) and Epidemiology of Diabetes Interventions and Complications (EDIC) follow-up study. METHODS: Stage of DR was measured every 6 months from standard fundus photographs, and refractive error was measured annually during the 6.5 years of DCCT; then, both were staggered every fourth year during EDIC with the full cohort measured at EDIC years 4 and 10. Outcomes of DR were 2- or 3-step progression, presence of proliferative DR (PDR), clinically significant macular edema (CSME), diabetic macular edema (DME), or ocular surgery. Myopia, emmetropia, and hyperopia were defined as a spherical equivalent of ≤-0.5, >-0.5 and <0.5, and ≥0.5, respectively. MAIN OUTCOME MEASURES: For each outcome separately, Cox proportional hazard (PH) models assessed the association between the refractive error status and the subsequent risk of that outcome, both without and with adjustment for potential risk factors. RESULTS: Hyperopia was associated with a higher risk of 2-step progression (hazard ratio [HR], 1.29; 95% confidence interval [CI], 1.05-1.59), 3-step progression (HR, 1.35; 95% CI, 1.05-1.73), and PDR (HR, 1.40; 95% CI, 1.02-1.92) compared with emmetropia in unadjusted models. These associations remained significant after adjustment for DCCT treatment group, cohort, age, sex, smoking, duration of diabetes, systolic and diastolic blood pressures, pulse, low-density lipoprotein, high-density lipoprotein, triglycerides, albumin excretion rate, and DCCT/EDIC mean updated hemoglobin A1c (HbA1c) (2-step progression: HR, 1.28; 95% CI, 1.03-1.58; 3-step progression: HR, 1.30; 95% CI, 1.00-1.68; PDR: HR, 1.38; 95% CI, 1.00-1.90). Myopia was not associated with any of the 5 DR outcomes in the unadjusted models and only marginally associated with 2-step progression (HR, 1.11; 95% CI, 1.00-1.24) in the adjusted models. CONCLUSIONS: Myopia is not associated with DR progression risk. Hyperopia is an independent risk factor for 2-step and 3-step DR progression and PDR.


Assuntos
Diabetes Mellitus Tipo 1/fisiopatologia , Retinopatia Diabética/fisiopatologia , Hiperopia/fisiopatologia , Miopia/fisiopatologia , Adulto , Glicemia/metabolismo , Pressão Sanguínea , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/etiologia , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/etiologia , Progressão da Doença , Feminino , Seguimentos , Hemoglobinas Glicadas/metabolismo , Humanos , Edema Macular/diagnóstico , Edema Macular/etiologia , Edema Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Fatores de Risco
2.
Retina ; 40(2): 303-311, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31972801

RESUMO

PURPOSE: To analyze and provide an overview of the incidence, management, and prevention of conjunctival erosion in Argus II clinical trial subjects and postapproval patients. METHODS: This retrospective analysis followed the results of 274 patients treated with the Argus II Retinal Prosthesis System between June 2007 and November 2017, including 30 subjects from the US and European clinical trials, and 244 patients in the postapproval phase. Results were gathered for incidence of a serious adverse event, incidence of conjunctival erosion, occurrence sites, rates of erosion, and erosion timing. RESULTS: Overall, 60% of subjects in the clinical trial subjects versus 83% of patients in the postapproval phase did not experience device- or surgery-related serious adverse events. In the postapproval phase, conjunctival erosion had an incidence rate of 6.2% over 5 years and 11 months. In 55% of conjunctival erosion cases, erosion occurred in the inferotemporal quadrant, 25% in the superotemporal quadrant, and 20% in both. Sixty percent of the erosion events occurred in the first 15 months after implantation, and 85% within the first 2.5 years. CONCLUSION: Reducing occurrence of conjunctival erosion in patients with the Argus II Retinal Prosthesis requires identification and minimization of risk factors before and during implantation. Implementing inverted sutures at the implant tabs, use of graft material at these locations as well as Mersilene rather than nylon sutures, and accurate Tenon's and conjunctiva closure are recommended for consideration in all patients.


Assuntos
Túnica Conjuntiva/cirurgia , Doenças da Túnica Conjuntiva/etiologia , Complicações Pós-Operatórias/etiologia , Implantação de Prótese/efeitos adversos , Retinose Pigmentar/cirurgia , Próteses Visuais/efeitos adversos , Doenças da Túnica Conjuntiva/epidemiologia , Doenças da Túnica Conjuntiva/prevenção & controle , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Implantação de Prótese/métodos , Estudos Retrospectivos , Estados Unidos/epidemiologia
3.
Graefes Arch Clin Exp Ophthalmol ; 257(11): 2489-2494, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31388743

RESUMO

BACKGROUND: To characterize how prior incisional glaucoma surgery affects the intraocular pressure (IOP) elevation immediately following intravitreal anti-VEGF injections (IVI). METHODS: Single institution, experimental study. Patients with a history of incisional glaucoma surgery who were receiving anti-VEGF injections were recruited as well as control eyes. Pre- and post-injection IOP measurements were compared as well as time to recovery to within 5 and 10 mmHg of baseline IOP. RESULTS: Ten eyes with a history of glaucoma surgery and 29 control eyes receiving anti-VEGF injections were included. The most common indication for intravitreal anti-VEGF injection was proliferative diabetic retinopathy in both surgical and control eyes (50% vs 45%, p = 1.00). Post-injection IOP was significantly decreased compared to baseline IOP after anti-VEGF injection in surgical versus control eyes (26.5 ± 8.9 mmHg vs 44.2 ± 8.5 mmHg, respectively, p < 0.001). The mean change in IOP following intravitreal anti-VEGF injection was lower in surgical eyes (10.7 ± 6.6 mmHg vs 28.6 ± 8.3 mmHg, p < 0.001). The mean time for the IOP to return to within 10 mmHg of pre-injection IOP was less in surgical eyes (5.2 ± 4.1 min vs 13.3 ± 7.6 min, p = 0.002). CONCLUSIONS: Eyes with prior incisional glaucoma surgery demonstrated a significantly lower post-injection IOP elevation and a faster recovery to within 10 mmHg of their pre-injection IOP. Incisional glaucoma surgery may be considered for patients where the attenuation of post-injection IOP elevation is needed and other less invasive measures have failed.


Assuntos
Bevacizumab/administração & dosagem , Cirurgia Filtrante/métodos , Glaucoma/terapia , Pressão Intraocular/fisiologia , Ranibizumab/administração & dosagem , Idoso , Inibidores da Angiogênese/administração & dosagem , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Injeções Intravítreas , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Estudos Prospectivos , Tonometria Ocular , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular
4.
Retina ; 38(10): 1913-1919, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28796149

RESUMO

PURPOSE: To evaluate visual and anatomical outcomes of diabetic tractional retinal detachment repaired with pars plana vitrectomy. METHODS: Operative records were used to retrospectively identify all patients with tractional retinal detachments secondary to proliferative diabetic retinopathy surgically repaired with pars plana vitrectomy between November 1, 2009, and January 1, 2015 at the LAC + USC (Los Angeles County + University of Southern California) Medical Center. RESULTS: A total of 403 eyes with diabetic tractional retinal detachment in 359 patients were included. Successful reattachment of the retina was achieved in 87.6% of eyes after one surgery and 92.6% of eyes at the final follow-up. Best-corrected visual acuity at the final follow-up improved two or more lines in 56.3% of eyes, was stable in 23.8% of eyes, and decreased two or more lines in 19.9% of eyes. Eyes repaired with 23-gauge and 25-gauge vitrectomy systems had similar success rates as eyes treated with 20-gauge instrumentation (P = 0.73). Eyes receiving silicone oil tamponade had lower single-surgery reattachment rates (77.6% vs. 87.6%; P = 0.013), lower reattachment rates at the final follow-up (85.7% vs. 92.6%; P = 0.048), and higher rates of vision loss (34.7% vs. 19.9%; P < 0.0001) but were more likely to have concurrent rhegmatogenous detachment (47.0% vs. 21.3%; P < 0.0001) and macula involving detachment (74.5% vs. 60.0%; P < 0.0001). CONCLUSION: In this large, single-center retrospective study of patients with advanced diabetic tractional retinal detachment, vitrectomy achieved excellent anatomical outcome and improved or stabilized vision in 80.1% of eyes. Smaller gauge vitrectomy systems were found to have similar outcomes to 20-gauge instrumentation.


Assuntos
Retinopatia Diabética/complicações , Descolamento Retiniano/cirurgia , Vitrectomia/métodos , Adulto , Idoso , Retinopatia Diabética/patologia , Retinopatia Diabética/fisiopatologia , Feminino , Humanos , Macula Lutea/patologia , Masculino , Pessoa de Meia-Idade , Descolamento Retiniano/patologia , Descolamento Retiniano/fisiopatologia , Estudos Retrospectivos , Acuidade Visual/fisiologia
5.
Clin Exp Ophthalmol ; 45(2): 152-159, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27495262

RESUMO

BACKGROUND: The main objective of this study was to test Argus II subjects on three real-world functional vision tasks. DESIGN: The study was designed to be randomized and prospective. Testing was conducted in a hospital/research laboratory setting at the various participating centres. PARTICIPANTS: Twenty eight Argus II subjects, all profoundly blind, participated in this study. METHODS: Subjects were tested on the three real-world functional vision tasks: Sock Sorting, Sidewalk Tracking and Walking Direction Discrimination task MAIN OUTCOME MEASURES: For the Sock Sorting task, percentage correct was computed based on how accurately subjects sorted the piles on a cloth-covered table and on a bare table. In the Sidewalk Tracking task, an 'out of bounds' count was recorded, signifying how often the subject veered away from the test course. During the Walking Direction Discrimination task, subjects were tested on the number of times they correctly identified the direction of testers walking across their field of view. RESULTS: The mean percentage correct OFF versus ON for the Sock Sorting task was found to be significantly different for both testing conditions (t-test, P < 0.01). On the Sidewalk Tracking task, subjects performed significantly better with the system ON than they did with the system OFF (t-test, P < 0.05). Eighteen (18) of 27 subjects (67%) performed above chance with the system ON, and 6 (22%) did so with system OFF on the Walking Direction Discrimination task. CONCLUSIONS: Argus II subjects performed better on all three tasks with their systems ON than they did with their systems OFF.


Assuntos
Cegueira/reabilitação , Retina/fisiopatologia , Acuidade Visual , Próteses Visuais , Pessoas com Deficiência Visual/reabilitação , Cegueira/fisiopatologia , Eletrodos Implantados , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Caminhada
6.
Ophthalmology ; 123(10): 2248-54, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27453256

RESUMO

PURPOSE: The Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) was developed to restore some vision to patients blind as a result of retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception resulting from end-stage RP. DESIGN: Prospective, multicenter, single-arm clinical trial. Within-patient controls included the nonimplanted fellow eye and patients' native residual vision compared with their vision with the Argus II. PARTICIPANTS: Thirty participants in 10 centers in the United States and Europe. METHODS: The worse-seeing eye of blind patients was implanted with the Argus II. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. MAIN OUTCOME MEASURES: The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests. Secondary measures included functional vision performance on objectively scored real-world tasks. RESULTS: Twenty-four of 30 patients remained implanted with functioning Argus II Systems at 5 years after implantation. Only 1 additional serious adverse event was experienced after the 3-year time point. Patients performed significantly better with the Argus II on than off on all visual function tests and functional vision tasks. CONCLUSIONS: The 5-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind as a result of RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada.


Assuntos
Cegueira/cirurgia , Retina/patologia , Retinose Pigmentar/complicações , Acuidade Visual , Próteses Visuais , Pessoas com Deficiência Visual/reabilitação , Adulto , Idoso , Cegueira/etiologia , Cegueira/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Retina/fisiopatologia , Retinose Pigmentar/fisiopatologia , Retinose Pigmentar/cirurgia , Fatores de Tempo , Resultado do Tratamento
7.
Ophthalmology ; 122(8): 1547-54, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26162233

RESUMO

PURPOSE: Retinitis pigmentosa (RP) is a group of inherited retinal degenerations leading to blindness due to photoreceptor loss. Retinitis pigmentosa is a rare disease, affecting only approximately 100 000 people in the United States. There is no cure and no approved medical therapy to slow or reverse RP. The purpose of this clinical trial was to evaluate the safety, reliability, and benefit of the Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) in restoring some visual function to subjects completely blind from RP. We report clinical trial results at 1 and 3 years after implantation. DESIGN: The study is a multicenter, single-arm, prospective clinical trial. PARTICIPANTS: There were 30 subjects in 10 centers in the United States and Europe. Subjects served as their own controls, that is, implanted eye versus fellow eye, and system on versus system off (native residual vision). METHODS: The Argus II System was implanted on and in a single eye (typically the worse-seeing eye) of blind subjects. Subjects wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. MAIN OUTCOME MEASURES: The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests. RESULTS: A total of 29 of 30 subjects had functioning Argus II Systems implants 3 years after implantation. Eleven subjects experienced a total of 23 serious device- or surgery-related adverse events. All were treated with standard ophthalmic care. As a group, subjects performed significantly better with the system on than off on all visual function tests and functional vision assessments. CONCLUSIONS: The 3-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. Earlier results from this trial were used to gain approval of the Argus II by the Food and Drug Administration and a CE mark in Europe. The Argus II System is the first and only retinal implant to have both approvals.


Assuntos
Cegueira/reabilitação , Implantação de Prótese , Retinose Pigmentar/cirurgia , Baixa Visão/reabilitação , Próteses Visuais , Adulto , Idoso , Eletrodos Implantados , Feminino , Seguimentos , Humanos , Masculino , Microeletrodos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Retinose Pigmentar/fisiopatologia , Método Simples-Cego , Acuidade Visual/fisiologia
8.
Ophthalmol Sci ; 4(5): 100510, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38881600

RESUMO

Objective: To assess the efficacy and safety of the PRIMA neurostimulation system with a subretinal microchip for improving visual acuity (VA) in patients with geographic atrophy (GA) due to age-related macular degeneration (AMD) at 48-months postimplantation. Design: Feasibility clinical trial of the PRIMA subretinal prosthesis in patients with atrophic AMD, measuring best-corrected ETDRS VA (Clinicaltrials.govNCT03333954). Subjects: Five patients with GA, no foveal light perception, and VA of logarithm of the minimum angle of resolution (logMAR) 1.3 to 1.7 (20/400-20/1000) in their worse-seeing "study" eye. Methods: In patients subretinally implanted with a photovoltaic neurostimulation array containing 378 pixels of 100 µm in size, the VA was measured with and without the PRIMA system using ETDRS charts at 1 m. The system's external components, augmented reality glasses, and pocket computer provide image processing capabilities, including zoom. Main Outcome Measures: Visual acuity using ETDRS charts with and without the system, as well as light sensitivity in the central visual field, measured by Octopus perimetry. Anatomical outcomes demonstrated by fundus photography and OCT up to 48 months postimplantation. Results: All 5 subjects met the primary end point of light perception elicited by the implant in the scotoma area. In 1 patient, the implant was incorrectly inserted into the choroid. One subject died 18 months postimplantation due to study-unrelated reasons. ETDRS VA results for the remaining 3 subjects are reported here. Without zoom, VA closely matched the pixel size of the implant: 1.17 ± 0.13 pixels, corresponding to a mean logMAR of 1.39, or Snellen of 20/500, ranging from 20/438 to 20/565. Using zoom at 48 months, subjects improved their VA by 32 ETDRS letters versus baseline (standard error 5.1) 95% confidence intervals (13.4, 49.9; P < 0.0001). Natural peripheral visual function in the treated eye did not decline after surgery or during the 48-month follow-up period (P = 0.08). Conclusions: Subretinal implantation of PRIMA in subjects with GA experiencing profound vision loss due to AMD is feasible and well tolerated, with no reduction of natural peripheral vision up to 48 months. Prosthetic central vision provided by photovoltaic neurostimulation enabled patients to reliably recognize letters and sequences of letters, and with zoom, it improved VA of up to 8 ETDRS lines. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

9.
Retin Cases Brief Rep ; 16(4): 452-456, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32459699

RESUMO

PURPOSE: To report two cases of idiopathic intraocular cilia presenting as sectoral scleritis with progressive intraocular inflammation. METHODS: Both patients were treated with intravitreal antibiotics and underwent pars plana vitrectomy where the cilia were removed and identified on histopathology. RESULTS: One patient developed a retinal detachment while being treated for presumed endophthalmitis. The intraocular cilium was discovered during pars plana vitrectomy. In the second case, the cilium was detected on dilated fundus exam and was believed to be the cause of the patient's scleritis and vitritis. Therapeutic vitrectomy was performed. In both cases, the cilia were positively identified on histopathology. CONCLUSION: Idiopathic intraocular penetration of cilia should be considered in the differential diagnosis of sectoral scleritis with progressive intraocular inflammation.


Assuntos
Endoftalmite , Esclerite , Doenças da Úvea , Uveíte , Cílios , Endoftalmite/etiologia , Humanos , Inflamação/complicações , Inflamação/cirurgia , Estudos Retrospectivos , Esclerite/diagnóstico , Doenças da Úvea/cirurgia , Uveíte/complicações , Vitrectomia/efeitos adversos
12.
Diabetes Res Clin Pract ; 167: 108361, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32745697

RESUMO

The most common microvascular complication of diabetes is diabetic retinopathy, the leading cause of blindness in adults of working age. Our understanding of the vascular changes in diabetic retinopathy was enhanced by the demonstration of fluorescein angiography (FA) in the human retina for the first time in 1961. It was subsequently integrated with digital fundoscopic imaging to become an invaluable technique in evaluation of the retinal vasculature. The recent development of OCT-angiography (OCT-A) has revolutionized the clinician's ability to examine the retinal vasculature without the need for injection of a contrast dye. By coupling OCT, which can provide noninvasive cross-sectional imaging of the central retina, with angiography in OCT-A, one can reveal retinal perfusion by allowing visualization of the depth-resolved retinal capillary plexus. OCT-A has allowed for more precise delineation of changes in the retinal microvasculature, specifically the alterations of retinal vasculature and loss of capillary perfusion from chronic microvascular occlusion in diabetic retinopathy.


Assuntos
Angiografia/métodos , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/terapia , Tomografia de Coerência Óptica/métodos , Adulto , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/patologia , Retinopatia Diabética/patologia , Angiofluoresceinografia/métodos , Humanos , Microvasos/diagnóstico por imagem , Pessoa de Meia-Idade , Oftalmoscopia/métodos , Retina/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem
13.
J AAPOS ; 24(5): 306-309, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32919079

RESUMO

Cohen syndrome is a rare disease that causes myopia and retinal degeneration in the setting of developmental delay and characteristic craniofacial features. We report optical coherence tomography (OCT) abnormalities in 4 patients with Cohen syndrome, 2 of whom have longitudinal follow-up. All subjects had schisis-like changes, with cystoid spaces in the inner retina as well as diffuse outer retinal atrophy sparing the subfoveal region. Ophthalmologic findings in 1 patient led to the work-up that resulted in a diagnosis of Cohen syndrome, suggesting that characteristic retinal abnormalities visualized by fundus examination and OCT may represent distinguishing features of this syndrome.


Assuntos
Miopia , Degeneração Retiniana , Deficiências do Desenvolvimento , Dedos/anormalidades , Humanos , Deficiência Intelectual , Microcefalia , Hipotonia Muscular , Miopia/diagnóstico , Obesidade , Degeneração Retiniana/diagnóstico por imagem , Tomografia de Coerência Óptica
14.
PLoS One ; 15(12): e0243830, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33306736

RESUMO

PURPOSE: To quantitatively assess choriocapillaris (CC) flow deficits in eyes with diabetic retinopathy (DR) using swept-source optical coherence tomography angiography (SS-OCTA). METHODS: Diabetic subjects with different stages of DR and age-matched healthy subjects were recruited and imaged with SS-OCTA. The en face CC blood flow images were generated using previously published and validated algorithms. The percentage of CC flow deficits (FD%) and the mean CC flow deficit size were calculated in a 5-mm-diameter circle centered on the fovea from the 6×6-mm scans. RESULTS: Forty-five diabetic subjects and 27 control subjects were included in the study. The CC FD% in diabetic eyes was on average 1.4-fold greater than in control eyes (12.34±4.14% vs 8.82±2.61%, P < 0.001). The mean CC FD size in diabetic eyes was on average 1.4-fold larger than in control eyes (2151.3± 650.8µm2 vs 1574.4±255.0 µm2, P < 0.001). No significant difference in CC FD% or mean CC FD size was observed between eyes with nonproliferative DR and eyes with proliferative DR (P = 1.000 and P = 1.000, respectively). CONCLUSIONS: CC perfusion in DR can be objectively and quantitatively assessed with FD% and FD size. In the macular region, both CC FD% and CC FD size are increased in eyes with DR. SS-OCTA provides new insights for the investigations of CC perfusion status in diabetes in vivo.


Assuntos
Corioide/irrigação sanguínea , Corioide/diagnóstico por imagem , Retinopatia Diabética/diagnóstico por imagem , Tomografia de Coerência Óptica , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade
15.
Am J Ophthalmol ; 217: 325-334, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32217118

RESUMO

PURPOSE: To associate detection of potential pathogen DNA in endophthalmitis with clinical outcomes. DESIGN: Prospective cohort study. METHODS: Patients in whom endophthalmitis was diagnosed following an intraocular procedure were recruited. Clinical outcome data from baseline, week-1, month-1, and month-3 visits were collected. Intraocular biopsy samples were cultured by standard methods. Quantitative polymerase chain reaction (qPCR) was performed for specific pathogens and whole-genome sequencing (WGS). RESULTS: A total of 50 patients (mean age 72 years old; 52% male) were enrolled. Twenty-four cases were culture-positive and 26 were culture-negative. WGS identified the cultured organism in 76% of culture-positive cases and identified potential pathogens in 33% of culture-negative cases. Month-1 and -3 visual acuities did not vary by pathogen-positive versus pathogen-negative cases as detected by either culture or WGS. Visual outcomes of Staphylococcus epidermidis endophthalmitis were no different than those of pathogen-negative cases, whereas the patients infected with other pathogens showed worse outcome. Higher baseline bacterial DNA loads of bacteria other than those of S epidermidis detected by WGS were associated with worse month-1 and -3 visual acuity, whereas the S epidermidis loads did not appear to influence outcomes. Torque teno virus (TTV) and Merkel cell polyomavirus (MCV) were detected by qPCR in 49% and 19% of cases, respectively. Presence of TTV at presentation was associated with a higher rate of secondary pars plana vitrectomy (P = .009) and retinal detachment (P = .022). CONCLUSIONS: The presence and higher load of bacteria other than S epidermidis detected by WGS or DNA from TTV by qPCR in ocular fluids is associated with worse outcomes in post-procedure endophthalmitis.


Assuntos
Bactérias/genética , DNA Bacteriano/análise , Endoftalmite/microbiologia , Infecções Oculares Bacterianas/microbiologia , Estudo de Associação Genômica Ampla/métodos , Corpo Vítreo/microbiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Endoftalmite/diagnóstico , Endoftalmite/genética , Infecções Oculares Bacterianas/diagnóstico , Infecções Oculares Bacterianas/genética , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Prognóstico , Estudos Prospectivos , Acuidade Visual , Corpo Vítreo/diagnóstico por imagem
16.
J Ophthalmol ; 2019: 6710754, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31281669

RESUMO

PURPOSE: CAPTCHA (completely automated public turing test to tell computers and humans apart) was designed as a spam prevention test. In patients with visual impairment, completion of this task has been assumed to be difficult; but to date, no study has proven this to be true. As visual function is not well measured by Snellen visual acuity (VA) alone, we theorized that CAPTCHA performance may provide additional information on macular disease-related visual dysfunction. METHODS: This was designed as a pilot study. Active disease was defined as the presence of either intraretinal fluid (IRF) or subretinal fluid (SRF) on spectral-domain optical coherence tomography. CAPTCHA performance was tested using 10 prompts. In addition, near and distance VA, contrast sensitivity, and reading speed were measured. Visual acuity matched pseudophakic patients were used as controls. Primary outcome measures were average edit distance and percent of correct responses. RESULTS: 70 patients were recruited: 33 with active macular disease and 37 control subjects. Contrast sensitivity was found to be significantly different in both the IRF (p < 0.01) and SRF groups (p < 0.01). No significant difference was found comparing the odds ratio of average edit distance of active disease (IRF, SRF) vs. control (OR 1.09 (0.62, 1.90), 1.10 (0.58, 2.05), p=0.77, 0.77) or percent correct responses of active disease vs. control (OR 0.98 (0.96, 1.01), 1.09 (0.58, 2.05), p=0.22, 0.51) in CAPTCHA testing. The goodness of fit using logistic regression analysis for the dependent variables of either IRF or SRF did not improve accounting for average edit distance (p=0.49, p=0.27) or percent correct (p=0.89, p=0.61). CONCLUSIONS: Distance VA and contrast sensitivity are positively correlated with the presence of IRF and SRF in active macular disease. CAPTCHA performance did not appear to be a significant predictor of either IRF or SRF in our pilot study.

17.
Br J Ophthalmol ; 102(11): 1575-1578, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29437581

RESUMO

AIM: To evaluate whether people with age-related macular degeneration (AMD) and a history of amblyopia have equal severity of AMD in both eyes. METHODS: Billing records were used to locate all people with a history of amblyopia and AMD evaluated between 1 January 2003 and 1 June 2015 at a single ophthalmology institute. Two ophthalmic graders blinded to amblyopia status determined the severity of AMD in each eye using fundus photos and a validated grading scale. RESULTS: A total of 14 people were found to have AMD and a documented history of amblyopia. Average patient age was 77.0 years and average best corrected visual acuity was 20/160 in eyes with a history of amblyopia and 20/40 in fellow eyes without amblyopia. Eyes with a history of amblyopia were found to have a lower AMD severity score (mean lower score: -1.38; paired t-test P=0.019). Of the 11 people with asymmetric disease severity, 10 individuals had worse AMD in the non-amblyopic eye while one person had worse AMD in the amblyopic eye (P=0.0067). CONCLUSIONS: Our pilot study suggests that eyes with a history of amblyopia may manifest decreased severity of AMD compared with non-ambylopic eyes in the same patient. Further research is warranted to investigate this clinical observation.


Assuntos
Ambliopia/diagnóstico , Degeneração Macular/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Ambliopia/fisiopatologia , Feminino , Humanos , Degeneração Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Índice de Gravidade de Doença , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
18.
Am J Ophthalmol ; 193: 87-99, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29940167

RESUMO

PURPOSE: To assess the retinal anatomy and array position in Argus II retinal prosthesis recipients. DESIGN: Prospective, noncomparative cohort study. METHODS: Setting: International multicenter study. PATIENTS: Argus II recipients enrolled in the Post-Market Surveillance Studies. PROCEDURES: Spectral-domain optical coherence tomography images collected for the Surveillance Studies (NCT01860092 and NCT01490827) were reviewed. Baseline and postoperative macular thickness, electrode-retina distance (gap), optic disc-array overlap, and preretinal membrane presence were recorded at 1, 3, 6, and 12 months. MAIN OUTCOME MEASURES: Axial retinal thickness and axial gap along the array's long axis (a line between the tack and handle); maximal retinal thickness and maximal gap along a B-scan near the tack, midline, and handle. RESULTS: Thirty-three patients from 16 surgical sites in the United States and Germany were included. Mean axial retinal thickness increased from month 1 through month 12 at each location, but reached statistical significance only at the array midline (P = .007). The rate of maximal thickness increase was highest near the array midline (slope = 6.02, P = .004), compared to the tack (slope = 3.60, P < .001) or the handle (slope = 1.93, P = .368). The mean axial and maximal gaps decreased over the study period, and the mean maximal gap size decrease was significant at midline (P = .032). Optic disc-array overlap was seen in the minority of patients. Preretinal membranes were common before and after implantation. CONCLUSIONS: Progressive macular thickening under the array was common and corresponded to decreased electrode-retina gap over time. By month 12, the array was completely apposed to the macula in approximately half of the eyes.


Assuntos
Eletrodos Implantados , Retina/patologia , Retinose Pigmentar/cirurgia , Próteses Visuais , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Implantação de Prótese/métodos , Retinose Pigmentar/fisiopatologia , Acuidade Visual/fisiologia
19.
J Curr Ophthalmol ; 29(2): 133-135, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28626824

RESUMO

PURPOSE: To describe an atypical case of chronic central serous chorioretinopathy (CSCR). METHODS: A 58-year-old man with longstanding, bilateral visual impairment was self-referred for a second opinion. RESULTS: Findings by direct ophthalmoscopy, optical coherence tomography, fluorescein angiography, and fundus autofluorescence (FAF) were suggestive of atypical, chronic CSCR. Treatment with oral anti-mineralocorticoids resulted in moderate improvement, and photodynamic therapy (PDT) had minimal effect. CONCLUSION: Chronic CSCR may lack cardinal features of CSCR. Once retinal degenerative changes ensue, current treatments may not be effective in improving anatomical and visual outcomes in patients with chronic CSCR.

20.
J Glaucoma ; 26(6): e180-e186, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28221332

RESUMO

PURPOSE: To evaluate the clinical characteristics of a patient with primary open-angle glaucoma in whom macular retinoschisis resolved completely after trabeculectomy consistently lowered intraocular pressure (IOP). METHODS: A single case report. RESULTS: We report a case of retinoschisis involving the macula in a patient with primary open-angle glaucoma in the absence of myopic maculopathy, optic nerve anomaly, or x-linked retinoschisis. The patient's glaucoma was associated with progressive visual field loss in the setting of IOP fluctuations related to posture. A trabeculectomy reduced IOP and posture-related IOP fluctuations with subsequent resolution of macular retinoschisis. In the 1-year postoperative period following trabeculectomy, the patient has remained without retinoschisis and visual fields have been stable. CONCLUSIONS: Improved IOP control resulting in resolution of retinoschisis may distinguish retinoschisis associated with glaucoma from other forms of retinoschisis.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Retinosquise/cirurgia , Trabeculectomia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA