Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Open Vet J ; 13(4): 427-432, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37251269

RESUMO

Background: Accurate dose assessment during animal radiotherapy is beneficial for veterinary medicine and medical education. Aim: To visualize the radiation treatment distribution of orthovoltage X-ray equipment in clinical practice using Monte Carlo simulations and create a dog skull water phantom for animal-specific radiotherapy. Methods: EGSnrc-based BEAMnrc and DOSXYZnrc codes were used to simulate orthovoltage dose distributions. At 10, 20, 30, 40, 50, and 80 mm in a water phantom, the depth dose was measured with waterproof Farmer dosimetry chambers, and the diagonal off-axis ratio was measured with Gafchromic EBT3 film to simulate orthovoltage dose distributions. Energy differences between orthovoltage and linear accelerated radiotherapy were assessed with a heterogeneous bone and tissue virtual phantom. The animal-specific phantom for radiotherapy quality assurance (QA) was created from CT scans of a dog and printed with a three-dimensional printer using polyamide 12 nylon, with insertion points for dosimetry chambers and Gafchromic EBT3 film. Results: Monte Carlo simulated and measured dose distributions differed by no more than 2.0% along the central axis up to a depth of 80 mm. The anode heel effect occurred in shallow areas. The orthovoltage radiotherapy percentage depth dose in bone was >40%. Build-up was >40%, with build-down after bone exit, whereas linear accelerator radiotherapy absorption changed little in the bone. A highly water-impermeable, animal-specific dog skull water phantom could be created to evaluate dose distribution. Conclusion: Animal-specific water phantoms and Monte Carlo simulated pre-treatment radiotherapy are useful QA for orthovoltage radiotherapy and yield a visually familiar phantom that will be useful for veterinary medical education.


Assuntos
Radiometria , Água , Cães , Animais , Raios X , Radiometria/veterinária , Radiometria/métodos , Crânio , Impressão Tridimensional
2.
Phys Eng Sci Med ; 46(2): 623-632, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36940063

RESUMO

It is important to plan radiotherapy treatment and establish optimal dose distribution to reduce the chances of side effects and injury. Because there are no commercially available tools for calculating dose distribution in orthovoltage radiotherapy in companion animals, we developed an algorithm to accomplish this and verified its characteristics using tumor disease cases. First, we used the Monte Carlo method to develop an algorithm to calculate the dose distribution of orthovoltage radiotherapy (280 kVp; MBR-320, Hitachi Medical Corporation, Tokyo, Japan) using BEAMnrc at our clinic. Using development of Monte Carlo method, dose distribution for tumor and normal organs were evaluated in brain tumors, squamous cell carcinomas of the head, and feline nasal lymphomas. In all cases of brain tumors, the mean dose delivered to the GTV ranged from 36.2 to 76.1% of the prescribed dose due to the decrease through the skull. In the nasal lymphoma in cats, the eyes with covered a 2 mm-thick lead plate, the respective average dose to the eyes was 71.8% and 89.9% less than that to the uncovered eyes. The findings may be useful for informed decision making in orthovoltage radiotherapy with more effective and targeted irradiation and data collection allowing detailed informed consent.


Assuntos
Neoplasias Encefálicas , Planejamento da Radioterapia Assistida por Computador , Animais , Gatos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Método de Monte Carlo , Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA