Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
BMC Womens Health ; 23(1): 253, 2023 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-37170270

RESUMO

BACKGROUND: Endometriosis is the presence of active ectopic endometrial glands and stroma at other sites outside the uterine cavity. It is a common cause of chronic pelvic pain which is sometimes debilitating, and inflammation is one of the known triggers of endometriosis. Interleukins 6 and 16 (IL-6 and IL-16) are proinflammatory cytokines which play essential roles in inflammatory diseases. We therefore investigated the relationship between genetic polymorphisms of interleukins 6 and 16, and the development of endometriosis in Nigerian women. METHOD: One hundred and thirty (130) consenting women were consecutively enrolled, sixty-five (65) of whom had endometriosis and 65 age-matched women as reference group, surgically confirmed as not having endometriosis. Spectrophotometric determination of serum concentrations of Interleukins 6 and 16 was carried out and the genotyping of IL-6 (rs1800795) and IL-16 (rs4778889, rs11556218, rs4072111) genes were performed using TaqMan assays. RESULTS: Serum IL-16 concentration was significantly higher in women with severe chronic pelvic pain compared to those with mild pain (p = 0.023). The C allele of rs4778889 was associated with endometriosis (OR: 1.80, 95% CI: 1.08 - 3.02, p = 0.024). CONCLUSION: Serum IL-16 and IL-16 rs4778889 may be important markers for endometriosis in Nigerian, and by extension, African women. Multicentre African studies would clarify this.


Assuntos
Dor Crônica , Endometriose , Humanos , Feminino , Endometriose/genética , Endometriose/complicações , Interleucina-16/genética , Predisposição Genética para Doença , Interleucina-6/genética , Polimorfismo de Nucleotídeo Único , Dor Pélvica/genética , Dor Pélvica/complicações , Dor Crônica/complicações , Estudos de Casos e Controles
2.
BMC Public Health ; 22(1): 1922, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-36243709

RESUMO

OBJECTIVE: To evaluate the feasibility and performance of self-collected vaginal swab samples for HPV screening among women in Lagos, Nigeria. METHODS: A cross-sectional study was implemented from March to August 2020 among sexually active women. Study participants provided same-day paired vaginal swab samples. Medic-sampling and poster-directed self-sampling methods were used to collect the two samples per participant. A real-time PCR assay detected HPV 16, HPV 18, other-high-risk (OHR) HPV, and the human ß-globin gene. The self-collected samples' sensitivity, specificity, and accuracy were determined against the medic-collected samples using the MedCalc Online Diagnostic Calculator. RESULTS: Of the 213 women aged 16 ~ 63-year-old recruited, 187 (88%) participants had concordant results, while 26 (12%) participants had discordant results. Among the 187 concordant results, 35 (19%) were HPV positive, 150 (80%) participants were HPV negative, and two (1%) were invalid. 18 (69%) out of the 26 discordant samples were invalid. The self-collected sample was invalid for 14 (54%) participants. Two (8%) medic-collected samples were invalid. Compared to the medic-collected sample, the self-collected sample was 89.80% (95% CI: 77.77 ~ 96.60%) sensitive and 98.21% (95% CI: 94.87 ~ 99.63%) specific, with an accuracy of 96.31% (95% CI: 92.87 ~ 98.40%). The mean age for HPV positive and negative participants were 39 and 40, respectively, with an ANOVA p-value of 0.3932. The stratification of HPV infection by the age group was not statistically significant (P > 0.05). CONCLUSIONS: With high accuracy of 96%, self-collected sampling is adequate when tested with real-time PCR and may increase the uptake of HPV testing. Though more self-collected samples were invalid than medic-collected samples, most likely due to poor collection, they could be identified for repeat testing. Future implementation can avoid this error with improved guidance and awareness.


Assuntos
Alphapapillomavirus , Infecções por Papillomavirus , Neoplasias do Colo do Útero , Estudos Transversais , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Nigéria , Papillomaviridae/genética , Infecções por Papillomavirus/diagnóstico , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Neoplasias do Colo do Útero/diagnóstico , Esfregaço Vaginal/métodos , Globinas beta
3.
Front Oncol ; 13: 1254304, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37876969

RESUMO

Introduction: Human Papillomavirus (HPV) infection is a risk factor for cervical cancer, the fourth most common cancer among women globally. Its burden is the highest in sub-Saharan Africa, with over 90% mortality. Interventions may fail without evidence-based data on stratified prevalence and risk factors among most at-risk women across Nigeria. Methods: A cross-sectional comparative study, with participants recruited from the Nigerian Institute of Medical Research's Clinics, NGO outreaches, a cancer screening centre and a university teaching hospital. Questionnaires were self-administered. Trained medics performed sampling at healthcare facilities, and self-sampling was used at outreaches. Results: Nine hundred eighty-five study participants were recruited. About 37% and 27% of the women knew about HPV and its vaccines, respectively, but only 6% confirmed vaccination with HPV vaccines. HPV prevalence was highest among women with unknown marital status (35.9%), single women (33.8%), widowed/divorced/separated women (30.3%), and married/cohabiting women (19.6%). HPV infection was significantly higher among women who take alcohol (odds=1.7 [95% CI: 1.2-2.4]) and women who smoke (odds=2.6 [95% CI: 1.4 - 4.6]. HPV strains detected included HPV16 (1.3%), HPV18 (1.5%), Low Risk (0.2%) and Other High-Risk groups (19.7%). Conclusion: The inverse relationship between prevalence and education suggests interventions improving awareness and prevention would be impactful. Such interventions could also target HIV-positive women, women presenting with sexually-transmitted infections, who smoke and frequently drink alcohol.

4.
Viruses ; 14(6)2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35746741

RESUMO

A subgroup among people living with HIV (PLHIV) experience viral suppression, sometimes to an undetectable level in the blood and/or are able to maintain a healthy CD4+ T-cell count without the influence of antiretroviral (ARV) therapy. One out of three hundred PLHIV fall into this category, and a large sample of this group can be found in areas with a high prevalence of HIV infection such as Nigeria and South Africa. Understanding the mechanism underpinning the nonprogressive phenotype in this subgroup may provide insights into the control of the global HIV epidemic. This work provides mechanisms of the elite control and nonprogressive phenotype among PLHIV in Nigeria and South Africa and identifies research gaps that will contribute to a better understanding on HIV controllers among PLHIV.


Assuntos
Infecções por HIV , Controladores de Elite , Infecções por HIV/tratamento farmacológico , Infecções por HIV/genética , Humanos , Nigéria/epidemiologia , Prevalência , África do Sul/epidemiologia , Carga Viral
5.
PLoS One ; 16(6): e0252611, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34111179

RESUMO

The present global pandemic triggered by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has lingered for over a year in its devastating effects. Diagnosis of coronavirus disease 2019 (COVID-19) is currently established with a polymerase chain reaction (PCR) test by means of oropharyngeal-, nasopharyngeal-, anal-swabs, sputum and blood plasma. However, oral and nasal swabs are more commonly used. This study, therefore, assessed sensitivity and specificity of plasma as a diagnostic in comparison with a combination of oral and nasal swab samples, and the implications for blood transfusion. Oropharyngeal (OP) and nasopharyngeal (NP) swab samples were obtained from 125 individuals suspected to have COVID-19 and stored in viral transport medium (VTM) tubes. Ten millilitres of blood samples in EDTA were also obtained by venepuncture and spun to obtain plasma. Viral RNA was obtained from both swabs and plasma by manual extraction with Qiagen QIAamp viral RNA Mini Kit. Detection was done using a real time fluorescent RT-qPCR BGI kit, on a QuantStudio 3 real-time PCR instrument. Average age of study participants was 41 years, with 74 (59.2%) being male. Out of the 125 individuals tested for COVID-19, 75 (60%) were positive by OP/NP swab. However, only 6 (4.8%) had a positive plasma result for COVID-19 with median Ct value of 32.4. Sensitivity and specificity of RT-PCR SARS-CoV-2 test using plasma was 8% and 100% respectively. There was no false positive recorded, but 69 (55.2%) false negatives were obtained by plasma. SARS-CoV-2 viral RNA was detected, albeit low (4.8%) in plasma. Plasma is likely not a suitable biological sample to diagnose acute SARS-CoV-2 infection. The implication of transfusing blood in this era of COVID-19 needs further investigations.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19/diagnóstico , RNA Viral/análise , SARS-CoV-2/isolamento & purificação , Adolescente , Adulto , Idoso , COVID-19/sangue , COVID-19/epidemiologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nigéria/epidemiologia , RNA Viral/sangue , RNA Viral/genética , SARS-CoV-2/genética , Sensibilidade e Especificidade , Adulto Jovem
6.
PLoS One ; 16(2): e0246637, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33539485

RESUMO

A key element in containing the spread of the SARS-CoV-2 infection is quality diagnostics which is affected by several factors. We now report the comparative performance of five real-time diagnostic assays. Nasopharyngeal swab samples were obtained from persons seeking a diagnosis for SARS-CoV-2 infection in Lagos, Nigeria. The comparison was performed on the same negative, low, and high-positive sample set, with viral RNA extracted using the Qiagen Viral RNA Kit. All five assays are one-step reverse transcriptase real-time PCR assays. Testing was done according to each assay's manufacturer instructions for use using real-time PCR platforms. 63 samples were tested using the five qPCR assays, comprising of 15 negative samples, 15 positive samples (Ct = 16-30; one Ct = 35), and 33 samples with Tib MolBiol E-gene Ct value ranging from 36-41. All assays detected all high positive samples correctly. Three assays correctly identified all negative samples while two assays each failed to correctly identify one different negative sample. The consistent detection of positive samples at different Ct/Cq values gives an indication of when to repeat testing and/or establish more stringent in-house cut-off value. The varied performance of different diagnostic assays, mostly with emergency use approvals, for a novel virus is expected. Comparative assays' performance reported may guide laboratories to determine both their repeat testing Ct/Cq range and/or cut-off value.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , RNA Viral/genética , SARS-CoV-2/genética , COVID-19/epidemiologia , COVID-19/virologia , Humanos , Nigéria/epidemiologia , RNA Viral/análise , Estudos Retrospectivos , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA