1.
Oral Dis ; 29(4): 1622-1631, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35189017

RESUMO

OBJECTIVES: The ciliopathies are a wide spectrum of human diseases, which are caused by perturbations in the function of primary cilia. Tooth enamel anomalies are often seen in ciliopathy patients; however, the role of primary cilia in enamel formation remains unclear. MATERIALS AND METHODS: We examined mice with epithelial conditional deletion of the ciliary protein, Ift88, (Ift88fl / fl ;K14Cre). RESULTS: Ift88fl / fl ;K14Cre mice showed premature abrasion in molars. A pattern of enamel rods which is determined at secretory stage, was disorganized in Ift88 mutant molars. Many amelogenesis-related molecules expressing at the secretory stage, including amelogenin and ameloblastin, enamelin, showed significant downregulation in Ift88 mutant molar tooth germs. Shh signaling is essential for amelogenesis, which was found to be downregulated in Ift88 mutant molar at the secretory stage. Application of Shh signaling agonist at the secretory stage partially rescued enamel anomalies in Ift88 mutant mice. CONCLUSION: Findings in the present study indicate that the function of the primary cilia via Ift88 is critical for the secretory stage of amelogenesis through involving Shh signaling.


Assuntos
Proteínas do Esmalte Dentário , Esmalte Dentário , Camundongos , Animais , Humanos , Amelogenina/genética , Amelogenina/metabolismo , Proteínas do Esmalte Dentário/genética , Proteínas do Esmalte Dentário/metabolismo , Amelogênese/genética , Proteínas Supressoras de Tumor , Proteínas Hedgehog/genética , Proteínas Hedgehog/metabolismo
2.
J Appl Clin Med Phys ; 18(6): 232-243, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28984023

RESUMO

To compare the radiation dose and image noise of nonenhanced CT scans performed at 80, 100, and 120 kVp with tube current modulation (TCM) we used anthropomorphic phantoms of newborn, 1-year-old, and 5-year-old children. The noise index was set at 12. The image noise in the center of the phantoms at the level of the chest and abdomen was measured within a circumscribed region of interest. We measured the doses in individual tissues or organs with radio-photoluminescence glass dosimeters for each phantom. Various tissues or organs were assigned and the radiation dose was calculated based on the international commission on radiological protection definition. With TCM the respective radiation dose at tube voltages of 80, 100, and 120 was 29.71, 31.60, and 33.79 mGy for the newborn, 32.00, 36.79, and 39.48 mGy for the 1-year-old, and 32.78, 38.11, and 40.85 mGy for the 5-year-old phantom. There were no significant differences in the radiation dose among the tube voltages and phantoms (P > 0.05). Our comparison of the radiation dose using anthropomorphic phantoms of young children showed that the radiation dose of nonenhanced CT performed at different tube voltages with TCM was not significantly different.


Assuntos
Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Antropometria , Criança , Humanos , Lactente , Recém-Nascido
4.
Maxillofac Plast Reconstr Surg ; 45(1): 4, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36662392

RESUMO

BACKGROUND: Craniofacial disharmony in cases of jaw deformity associated with abnormal lateral deviation of the jaw mostly involves both the maxilla and mandible. However, it has been still difficult to capture the jaw deviation aspect in a 3-dimensional and quantitative techniques. In this study, we focused on 3-dimensional mandibular morphology and position of the condylar head in relation to the base of the skull in patients with mandibular prognathism, one of the most common jaw deformities. We used cluster analysis to quantify and classify deviation and clarified its characteristics. We also investigated the degree of correlation between those findings and menton (Me) deviation measured on frontal cephalograms, which is a conventional indicator of jaw deformity. RESULTS: Findings obtained from 100 patients (35 men, 65 women) were classified into the following three groups based on mandibular morphology and condylar position relative to the skull base. Then, reclassification using these parameters enabled classification of cluster analysis findings into seven groups based on abnormal jaw deviation characteristics. Comparison among these seven groups showed that the classification criteria were ramus height, mandibular body length, distance from the gonion to the apex of the coronoid process, and the lateral and vertical positions of the mandible. Weak correlation was also found between Me deviation on frontal cephalograms and each of the above parameters measured on 3D images. CONCLUSIONS: Focusing on mandibular morphology and condylar position relative to the skull base in patients with mandibular prognathism, we used cluster analysis to quantify and classify jaw deviation. The present results showed that the 3D characteristics of the mandible based on mandibular morphology and condylar position relative to the skull base can be classified into seven groups. Further, we clarified that Me deviation on frontal cephalograms, which has been used to date, is inadequate for capturing jaw deviation characteristics.

5.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 63(5): 534-45, 2007 May 20.
Artigo em Japonês | MEDLINE | ID: mdl-17538218

RESUMO

Although many current CT scanners incorporate CT-AEC, performance evaluation is not standardized. This study evaluates the performance of the latest CT-AEC of each manufacturer with the aim of establishing a standard CT-AEC performance evaluation method. The design of the phantoms was based upon the operation characteristics of different CT-AECs. A cone, an ellipse, a variable-shaped ellipse, stepped phantoms, and their analysis software were devised and carried out the field test. The targets were LightSpeed VCT 64 with 2D and 3D Auto mA(GE), Aquilion 64M with Real-EC and Volume-EC(Toshiba), Sensation 64 with CARE Dose and CARE Dose 4D(Siemens), and Bulliance 16P with Dose Right(Philips). Data was acquired while varying the typical abdominal CT(with CT-AEC)scanning conditions (120 kV, 5 mm slice, standard function for abdomen, scanning range 200 mm). The acquired images were converted to the DICOM format and image noise(SD) was calculated using dedicated software. All 4 CT-AECs reduced exposure dose. For GE and Toshiba, image noise was constant and met the target. For Siemens, noise was independent of phantom shape but varied uniformly with phantom size. For Philips, noise varied with phantom size and shape, and variation degree depended on phantom thickness in scanogram direction. The results reflect the basic concept and performance characteristics of the methods. Standardization of CT-AEC performance evaluation is possible using these phantoms.


Assuntos
Tomografia Computadorizada por Raios X/instrumentação , Imagens de Fantasmas , Radiografia Abdominal/instrumentação , Tomografia Computadorizada por Raios X/normas