Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neuro Endocrinol Lett ; 35 Suppl 1: 40-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25433353

RESUMO

OBJECTIVE: The increasing number of patients with implantable cardiac devices raises the need for more efficient outpatient follow-up care. Due to technological progress in communication and transmission systems and in the implantable devices themselves, telemonitoring can be widely used as an important part of care for patients and devices. Our objective was to evaluate the benefits of continuous remote monitoring using the BIOTRONIK Home Monitoring® (HM) system compared to standard outpatient follow-ups. METHODS: 198 patients with single- or dual-chamber implantable cardioverter-defibrillator (ICD) implanted for primary or secondary prevention of sudden cardiac death were randomized into a group of patients followed through standard outpatient visits ( HM-) and a group telemonitored by the HM system (HM+). Planned and emergency visits, ICD-related hospitalizations, and delivered shocks and their appropriateness were evaluated in the respective groups. RESULTS: A significant reduction was achieved in the number of planned (by 48%, p<0.001) and total visits (by 45%, p<0.001) during a three-year evaluation. A comparable number of patients experienced one or more shocks. Mortality rates were equivalent, as was the number of patients hospitalized in relation to their ICD. However, there was a significant reduction in the number and proportion of inappropriate shocks delivered in the HM+ patient group: by 80% (p=0.002) in outpatient follow-up care and by 90% (p<0.001) when multiple shocks requiring hospitalization were included. CONCLUSIONS: The HM system was an effective and safe method of follow-up in patients with an implanted ICD. Remote monitoring reduces the number of outpatient visits and inappropriate shocks.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Monitorização Fisiológica/métodos , Marca-Passo Artificial , Telemetria/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Assistência de Longa Duração , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Estudos Prospectivos
2.
Pacing Clin Electrophysiol ; 33(9): 1039-46, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20528997

RESUMO

INTRODUCTION: Catheter ablation for paroxysmal atrial fibrillation is widely used for patients with drug-refractory paroxysms of arrhythmia. Recently, novel technologies have been introduced to the market that aim to simplify and shorten the procedure. AIM: To compare the clinical outcome of pulmonary vein (PV) isolation using a multipolar circular ablation catheter (PVAC group), with point-by-point PV isolation using an irrigated-tip ablation catheter and the CARTO mapping system (CARTO group; CARTO, Biosense Webster, Diamond Bar, CA, USA). METHODS: Patients with documented PAF were randomized to undergo PV isolation using PVAC or CARTO. Atrial fibrillation (AF) recurrences were documented by serial 7-day Holter monitoring. RESULTS: One hundred and two patients (mean age 58 ± 11 years, 68 men) were included in the study. The patients had comparable baseline clinical characteristics, including left atrial dimensions and left ventricular ejection fraction, in both study arms (PVAC: n = 51 and CARTO: n = 51). Total procedural and fluoroscopic times were significantly shorter in the PVAC group (107 ± 31 minutes vs 208 ± 46 minutes, P < 0.0001 and 16 ± 5 minutes vs 28 ± 8 minutes, P < 0.0001, respectively). The AF recurrence was documented in 23% and 29% of patients in the PVAC and CARTO groups, respectively (P = 0.8), during the mean follow-up of 200 ± 13 days. No serious complications were noted in both study groups. CONCLUSIONS: Clinical success rates of PV isolation are similar when using multipolar circular PV ablation catheter and point-by-point ablation with a three-dimensional (3D) navigation system in patients with PAF, and results in shorter procedural and fluoroscopic times with a comparable safety profile.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Idoso , Fibrilação Atrial/diagnóstico por imagem , República Tcheca , Eletrodos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Volume Sistólico/fisiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA