Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Rapid Commun Mass Spectrom ; 25(9): 1231-40, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21488121

RESUMO

The evaluation of interactions between drug candidates and transporters such as P-glycoprotein (P-gp) has gained considerable interest in drug discovery and development. Inhibition of P-gp can be assessed by performing bi-directional permeability studies with in vitro P-gp-expressing cellular model systems such as Caco-2 (human colon carcinoma) cells, using digoxin as a substrate probe. Existing methodologies include either assaying (3)H-digoxin with liquid scintillation counting (LSC) detection or assaying non-labeled digoxin with liquid chromatography-tandem mass spectrometric (LC-MS/MS) analysis at a speed of several minutes per sample. However, it is not feasible to achieve a throughput high enough using these approaches to sustain an early liability screen that generates more than a thousand samples on a daily basis. To address this challenge, we developed an ultrafast (9 s per sample) bioanalytical method for digoxin analysis using RapidFire™, an on-line solid-phase extraction (SPE) system, with MS/MS detection. A stable isotope labeled analog, d3-digoxin, was used as internal standard to minimize potential ionization matrix effect during the RF-MS/MS analysis. The RF-MS/MS method was more than 16 times faster than the LC-MS/MS method but demonstrated similar sensitivity, selectivity, reproducibility, linearity and robustness. P-gp inhibition results of multiple validation compounds obtained with this RF-MS/MS method were in agreement with those generated by both the LC-MS/MS method and the (3)H-radiolabel assay. This method has been successfully deployed to assess P-gp inhibition potential as an important early liability screen for drug-transporter interaction.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/antagonistas & inibidores , Cromatografia Líquida/métodos , Digoxina/análise , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas em Tandem/métodos , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Células CACO-2 , Ciclosporina/química , Ciclosporina/farmacologia , Digoxina/química , Digoxina/metabolismo , Descoberta de Drogas/métodos , Descoberta de Drogas/normas , Humanos , Modelos Lineares , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida , Trítio
2.
Comb Chem High Throughput Screen ; 11(3): 231-7, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18336215

RESUMO

Small molecule high-throughput screening in drug discovery today is dominated by techniques which are dependent upon artificial labels or reporter systems. While effective, these approaches can be affected by certain experimental limitations, such as conformational restrictions imposed by the selected label or compound fluorescence/quenching. Label-free approaches potentially address many of these issues by allowing researchers to investigate more native systems without fluorescence- or luminescence-based readouts. However, due to throughput and expense constraints, label-free methods have been largely relegated to a supporting role as the basis of secondary assays. In this review, we describe recent improvements in impedance-based, optical biosensor-based, automated patch clamp and mass spectrometry technologies that have enhanced their ease of use and throughput and, hence, their utility for primary screening of small- to medium-sized compound libraries. The ultimate maturation of these techniques will enable drug discovery researchers to screen large chemical libraries against minimally manipulated biological systems.


Assuntos
Avaliação Pré-Clínica de Medicamentos/métodos , Bibliotecas de Moléculas Pequenas , Animais , Avaliação Pré-Clínica de Medicamentos/instrumentação , Impedância Elétrica , Humanos , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Técnicas de Patch-Clamp/instrumentação , Técnicas de Patch-Clamp/métodos , Espectrofotometria/instrumentação , Espectrofotometria/métodos , Ressonância de Plasmônio de Superfície/instrumentação , Ressonância de Plasmônio de Superfície/métodos
3.
J Biomol Screen ; 12(4): 473-80, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17478485

RESUMO

Mass spectrometry is an emerging format for label-free high-throughput screening. The main limitation of mass spectrometry is throughput, due to the requirement to purify samples prior to ionization. Here the authors compare an automated high-throughput mass spectrometry (HTMS) system (RapidFire) with the scintillation proximity assay (SPA). The cancer therapy target AKT1/PKBalpha was screened against a focused library of kinase inhibitors and IC50 values determined for all compounds that exhibit > 50% inhibition. A selection of additional compounds that exhibited

Assuntos
Proteínas Proto-Oncogênicas c-akt/antagonistas & inibidores , Proteínas Proto-Oncogênicas c-akt/isolamento & purificação , Contagem de Cintilação , Espectrometria de Massas por Ionização por Electrospray , Sequência de Aminoácidos , Reações Falso-Negativas , Reações Falso-Positivas , Dados de Sequência Molecular , Inibidores de Proteínas Quinases/farmacologia , Proteínas Proto-Oncogênicas c-akt/química
4.
J Biomol Screen ; 12(5): 628-34, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17478478

RESUMO

A high-throughput mass spectrometry assay to measure the catalytic activity of phosphatidylserine decarboxylase (PISD) is described. PISD converts phosphatidylserine to phosphatidylethanolamine during lipid synthesis. Traditional methods of measuring PISD activity are low throughput and unsuitable for the high-throughput screening of large compound libraries. The high-throughput mass spectrometry assay directly measures phosphatidylserine and phosphatidylethanolamine using the RapidFiretrade mark platform at a rate of 1 sample every 7.5 s. The assay is robust, with an average Z' value of 0.79 from a screen of 9920 compounds. Of 60 compounds selected for confirmation, 54 are active in dose-response studies. The application of high-throughput mass spectrometry permitted a high-quality screen to be performed for an otherwise intractable target.


Assuntos
Carboxiliases/antagonistas & inibidores , Inibidores Enzimáticos/farmacologia , Espectrometria de Massas/métodos , Carboxiliases/análise , Carboxiliases/genética , Linhagem Celular , Relação Dose-Resposta a Droga , Avaliação Pré-Clínica de Medicamentos , Estabilidade Enzimática , Congelamento , Humanos , Rim/citologia , Cinética , Plasmídeos , Proteínas Recombinantes de Fusão/antagonistas & inibidores , Robótica , Análise de Sequência de DNA , Transfecção
5.
Assay Drug Dev Technol ; 2(4): 373-81, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15357918

RESUMO

Mass spectrometry-based screening can be applied to a wide range of targets, including those intractable targets that use substrates such as lipids, fatty acids, phospholipids, steroids, prostaglandins, and other compounds not generally amenable to conventional screening techniques. The major limitation to this approach is throughput, making HTS via mass spectrometry impractical. We present a mass spectrometry-based technique and hardware for lead discovery applications. Mass spectrometry enables the design of label-free assays using biologically native substrates for a wide range of enzymatic targets. This system can be used for the direct quantification of analytes in complex reaction mixtures with typical throughputs of 4-5 s per sample. A mass spectrometry-based assay was developed to identify inhibitors of acetylcholinesterase, an enzyme with clinical importance in Alzheimer's disease. The system was used to screen a small chemical library. Several potent inhibitors were identified, and the IC(50) values of the inhibitors were determined.


Assuntos
Acetilcolinesterase/análise , Acetilcolinesterase/metabolismo , Técnicas Analíticas Microfluídicas/métodos , Inibidores da Colinesterase/química , Inibidores da Colinesterase/farmacologia , Humanos , Concentração Inibidora 50 , Espectrometria de Massas/métodos , Técnicas Analíticas Microfluídicas/instrumentação
6.
Methods Mol Biol ; 987: 25-50, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23475665

RESUMO

We describe here a high-throughput assay to support rapid evaluation of drug discovery compounds for possible drug-drug interaction (DDI). Each compound is evaluated for its DDI potential by incubating over a range of eight concentrations and against a panel of six cytochrome P450 (CYP) enzymes: 1A2, 2C8, 2C9, 2C19, 2D6, and 3A4. The method utilizes automated liquid handling for sample preparation, and online solid-phase extraction/tandem mass spectrometry (SPE/MS/MS) for sample analyses. The system is capable of generating two 96-well assay plates in 30 min, and completes the data acquisition and analysis of both plates in about 30 min. Many laboratories that perform the CYP inhibition screening automate only part of the processes leaving a throughput bottleneck within the workflow. The protocols described in this chapter are aimed to streamline the entire process from assay to data acquisition and processing by incorporating automation and utilizing high-precision instrument to maximize throughput and minimize bottleneck.


Assuntos
Inibidores das Enzimas do Citocromo P-450 , Avaliação Pré-Clínica de Medicamentos/métodos , Inibidores Enzimáticos/farmacologia , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas/métodos , Inibidores Enzimáticos/química , Indicadores e Reagentes/química , Concentração Inibidora 50 , Ácido Tricloroacético/química
7.
J Biomol Screen ; 16(10): 1186-95, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21908798

RESUMO

Histone acetyltransferases (HATs) catalyze the transfer of an acetyl group from an acetyl-coenzyme A donor molecule to specific lysine residues within proteins. The acetylation state of proteins, particularly histones, is known to modulate their intermolecular binding properties and control various cellular processes, most notably transcriptional activation. In addition, deregulation of HAT activity has been linked to the development of a number of cancers; therefore, compounds that affect these enzymes have strong potential as therapeutic agents. The research presented here demonstrates three label-free HAT screening approaches, all based on the fast and direct measurement of one or more substrate-product pairs by high-throughput mass spectrometry techniques. The first approach involves monitoring all possible acetylation states of a peptide concurrently to measure HAT activity. The second approach measures acetylation reactions, on both peptides and whole protein substrates, via direct detection of the acetyl-coenzyme A cosubstrate and coenzyme A coproduct. Lastly, the authors demonstrate the ability to monitor directly the acetylation state of whole histone proteins in the same high-throughput manner using time-of-flight mass spectrometry. The generation of compound-mediated inhibition data using each of these techniques establishes mass spectrometry as a versatile, label-free, and biologically relevant screening approach to this challenging target class.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Histona Acetiltransferases/metabolismo , Acetilação/efeitos dos fármacos , Ativação Enzimática/efeitos dos fármacos , Histonas/química , Espectrometria de Massas , Peptídeos/farmacologia , Proteína Supressora de Tumor p53/química , Fatores de Transcrição de p300-CBP/metabolismo
8.
J Biomol Screen ; 16(10): 1217-26, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21911826

RESUMO

The sirtuin enzymes, a class of NAD(+)-dependent histone deacetylases, are a focal point of epigenetic research because of their roles in regulating gene expression and cellular differentiation by deacetylating histones and a host of transcription factors, including p53. Here, the authors present two label-free screening methodologies to study sirtuin activity using high-throughput mass spectrometry. The first method involves the detection of native peptides and provides a platform for more detailed mechanistic studies by enabling the concurrent and direct measurement of multiple modification states. The second method obviates the need for substrate-specific assay development by measuring the O-acetyl-ADP-ribose co-product formed by sirtuin-dependent deacetylation. Both methodologies were applied to investigating the deacetylation of multiple-peptide substrates by multiple-sirtuin enzymes. Kinetic data, including binding constants, inhibition, and, in some cases, activation, are demonstrated to correlate well, both between the methodologies and with previous literature precedent. In addition, the ability to monitor sirtuin activity via O-acetyl-ADP-ribose production permits experimentation on whole-protein substrates. The deacetylation of whole-histone proteins by SIRT3, and inhibition thereof, is presented and demonstrates the feasibility of screening sirtuins using more biologically relevant molecules.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Sirtuínas/análise , Sirtuínas/metabolismo , Acetilação/efeitos dos fármacos , Histonas/química , Humanos , Cinética , Espectrometria de Massas , O-Acetil-ADP-Ribose/análise , O-Acetil-ADP-Ribose/metabolismo , Peptídeos/farmacologia , Proteína Supressora de Tumor p53/química
9.
J Biomol Screen ; 15(4): 447-52, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20208033

RESUMO

A high-throughput online solid-phase extraction/tandem mass spectrometry (online SPE/MS/MS) system has been developed to support rapid evaluation of drug discovery compounds for possible drug-drug interaction (DDI). Each compound is evaluated for its DDI potential by incubating over a range of 8 test concentrations and against a panel of 6 cytochrome P450 (CYP) enzymes, 1A2, 2C8, 2C9, 2C19, 2D6, and 3A4. Previously, a postassay pooling and a 2-min gradient LC/MS/MS method had been reported to increase sample throughput, allowing for a 96-well plate of samples to be analyzed in under 4 h. The development of a new online SPE/MS/MS system has reduced the analysis time to less than 15 min per 96-well plate, translating to a 15-fold time savings compared to the 2-min LC/MS/MS method. Sampling precision without internal standard correction ranged from 3.1% to 5.6% relative standard deviation, and the carryover was determined to be between 1.0% and 4.1%. One hundred twenty in-house compounds were assayed and pooled for analyses using both the online SPE/MS/MS and LC/MS/MS, and the correlation coefficients ranged from 0.89 to 1.13, when comparing the IC(50) results obtained from the 2 approaches for each of the CYP enzymes.


Assuntos
Inibidores das Enzimas do Citocromo P-450 , Inibidores Enzimáticos/farmacologia , Ensaios de Triagem em Larga Escala/métodos , Sistemas On-Line , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Concentração Inibidora 50 , Padrões de Referência
10.
J Biomol Screen ; 15(1): 52-61, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20019290

RESUMO

A high-throughput mass spectrometry assay to measure the catalytic activity of UDP-3-O-(R-3-hydroxymyristoyl)-N-acetylglucosamine deacetylase, LpxC, is described. This reaction is essential in the biosynthesis of lipopolysaccharide (LPS) of gram-negative bacteria and is an attractive target for the development of new antibacterial agents. The assay uses the RapidFire mass spectrometry platform to measure the native LpxC substrate and the reaction product and thereby generates a ratiometric readout with minimal artifacts due to detection interference. The assay was robust in a high-throughput screen of a library of more than 700,000 compounds arrayed as orthogonal mixtures, with a median Z' factor of 0.74. Selected novel inhibitors from the screening campaign were confirmed as binding to LpxC by biophysical measurements using a thermal stability shift assay. Some inhibitors showed whole-cell antimicrobial activity against a sensitive strain of Escherichia coli with reduced LpxC activity (strain D22; minimum inhibitory concentrations ranging from 0.625-20 microg/mL). The results show that mass spectrometry-based screening is a valuable high-throughput screening tool for detecting inhibitors of enzymatic targets involving difficult to detect reactions.


Assuntos
Amidoidrolases/antagonistas & inibidores , Antibacterianos/análise , Inibidores Enzimáticos/análise , Inibidores Enzimáticos/farmacologia , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas/métodos , Antibacterianos/química , Antibacterianos/farmacologia , Dimetil Sulfóxido/farmacologia , Inibidores Enzimáticos/química , Estabilidade Enzimática/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Fluorescência , Testes de Sensibilidade Microbiana , Reprodutibilidade dos Testes , Bibliotecas de Moléculas Pequenas/análise , Bibliotecas de Moléculas Pequenas/farmacologia , Especificidade por Substrato/efeitos dos fármacos , Temperatura
11.
Assay Drug Dev Technol ; 7(5): 495-506, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19715455

RESUMO

Label-free mass spectrometric (MS) technologies are particularly useful for enzyme assay design for drug discovery screens. MS permits the selective detection of enzyme substrates or products in a wide range of biological matrices without need for derivatization, labeling, or capture technologies. As part of a cardiovascular drug discovery effort aimed at finding modulators of cystathionine beta-synthase (CBS), we used the RapidFire((R)) label-free high-throughput MS (HTMS) technology to develop a high-throughput screening (HTS) assay for CBS activity. The in vitro assay used HTMS to quantify the unlabeled product of the CBS reaction, cystathionine. Cystathionine HTMS analyses were carried out with a throughput of 7 s per sample and quantitation over a linear range of 80-10,000 nM. A compound library of 25,559 samples (or 80 384-well plates) was screened as singlets using the HTMS assay in a period of 8 days. With a hit rate of 0.32%, the actives showed a 90% confirmation rate. The in vitro assay was applied to secondary screens in more complex matrices with no additional analytical development. Our results show that the HTMS method was useful for screening samples containing serum, for cell-based assays, and for liver explants. The novel extension of the in vitro analytical method, without modification, to secondary assays resulted in a significant and advantageous economy of development time for the drug discovery project.


Assuntos
Cistationina/análise , Descoberta de Drogas/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Animais , Calibragem , Linhagem Celular , Cromatografia Líquida de Alta Pressão , Interpretação Estatística de Dados , Relação Dose-Resposta a Droga , Humanos , Indicadores e Reagentes , Cinética , Espectrometria de Massas , Camundongos , Camundongos Endogâmicos C57BL , Espectrometria de Massas por Ionização por Electrospray
12.
Anal Chim Acta ; 627(1): 105-11, 2008 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-18790133

RESUMO

Several recent reports suggest that stearoyl-CoA desaturase 1 (SCD1), the rate-limiting enzyme in monounsaturated fatty acid synthesis, plays an important role in regulating lipid homeostasis and lipid oxidation in metabolically active tissues. As several manifestations of type 2 diabetes and related metabolic disorders are associated with alterations in intracellular lipid partitioning, pharmacological manipulation of SCD1 activity might be of benefit in the treatment of these disease states. In an effort to identify small molecule inhibitors of SCD1, we have developed a mass spectrometry based high-throughput screening (HTS) assay using deuterium labeled stearoyl-CoA substrate and induced rat liver microsomes. The methodology developed allows the use of a nonradioactive substrate which avoids interference by the endogenous SCD1 substrate and/or product that exist in the non-purified enzyme source. Throughput of the assay was up to twenty 384-well assay plates per day. The assay was linear with protein concentration and time, and was saturable for stearoyl-CoA substrate (K(m)=10.5 microM). The assay was highly reproducible with an average Z' value=0.6. Conjugated linoleic acid and sterculic acid, known inhibitors of SCD1, exhibited IC(50) values of 0.88 and 0.12 microM, respectively. High-throughput mass spectrometry screening of over 1.7 million compounds in compressed format demonstrated that the enzyme target is druggable. A total of 2515 hits were identified (0.1% hit rate), and 346 were confirmed active (>40% inhibition of total SCD activity at 20 microM--14% conformation rate). Of the confirmed hits 172 had IC(50) values of <10 microM, including 111 <1 microM and 48 <100 nM. A large number of potent drug-like (MW<450) hits representing six different chemical series were identified. The application of mass spectrometry to high-throughput screening permitted the development of a high-quality screening protocol for an otherwise intractable target, SCD1. Further medicinal chemistry and characterization of SCD inhibitors should lead to the development of reagents to treat metabolic disorders.


Assuntos
Acil Coenzima A/metabolismo , Deutério/metabolismo , Avaliação Pré-Clínica de Medicamentos/métodos , Inibidores Enzimáticos/farmacologia , Microssomos Hepáticos/enzimologia , Estearoil-CoA Dessaturase/antagonistas & inibidores , Animais , Ciclopropanos/farmacologia , Citocromo-B(5) Redutase/metabolismo , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/enzimologia , Ácidos Graxos Monoinsaturados/farmacologia , Humanos , Modelos Lineares , Ácidos Linoleicos Conjugados/farmacologia , Masculino , Espectrometria de Massas , Microssomos Hepáticos/efeitos dos fármacos , Ratos , Bibliotecas de Moléculas Pequenas/farmacologia , Coloração e Rotulagem , Estearoil-CoA Dessaturase/metabolismo , Especificidade por Substrato , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA