Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Intensive Care Med ; 37(1): 114-119, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33292043

RESUMO

PURPOSE: To assess the potential clinical impact of an automated urine output (UOP) monitoring system in the intensive care unit. METHODS: Frequency of UOP documentation during a 20-month period was assessed in records of inpatients on the medicine floor, cardiac intensive care (CCU), and cardiothoracic-intensive care units (CTICU). Documentation timeliness (time between expected and observed UOP recording) was assessed over a 3-month period. A novel reusable device that monitors UOP based on continuous analysis of the weight of a urine collection container was tested in the CCU/CTICU. RESULTS: A total of 165,363 UOP measurements were recorded for 2,039 CCU/CTICU admissions. Sixty percent of CCU/CTICU admissions had UOP recorded in the electronic medical record (EMR) less than every 2 hours. One-third of CCU/CTICU measurements were documented more than 2 hours late, and only 10% were recorded less than 20 minutes late. Half of these patients had fewer than 2 measurements recorded per nursing shift and recordings were documented an average of 85 minutes late. There was no significant difference between daytime and nighttime shifts. UOP values obtained by the novel electronic monitoring device were within 27 ml (-224 ml, +228 ml) of nurses documented values, across 74 patients over a 24-hour period. CONCLUSIONS: Automating UOP monitoring using a reusable weight-based device is feasible and can improve timeliness of documentation and reduce nursing workload without compromising accuracy.


Assuntos
Unidades de Cuidados Coronarianos , Unidades de Terapia Intensiva , Registros Eletrônicos de Saúde , Humanos
2.
Transplantation ; 107(9): 1991-1998, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36959124

RESUMO

BACKGROUND: The ability of vibration controlled transient elastography (VCTE) to reliably exclude significant steatosis in living donor candidates could obviate the need for invasive liver biopsies, expedite the donor approval process, and reduce recipient wait time. We therefore aimed to determine whether VCTE controlled attenuation parameter (CAP) could be used to detect steatosis in potential living donors. METHODS: Living donor candidates who presented for evaluation between 2016 and 2019 underwent standard donor workup, VCTE, and liver biopsy if indicated. CAP scores were compared with MRI-Fat Fraction and, when available, histologic fat fraction from liver biopsy. Receiver operating characteristic curves were used to identify cutoffs with appropriate sensitivity and specificity for screening. Statistical analysis was conducted using R (version 3.6.0). RESULTS: Seventy-nine candidate living donors presented during the study period, of whom 71 were included in the final analysis and of whom 20 underwent liver biopsy. There was a positive correlation between MRI-Fat Fraction and CAP scores with an observed Spearman correlation coefficient of 0.424 ( P < 0.01). A CAP score of 271.5 dB/m or less was determined to have 89.8% sensitivity and 75% specificity for detecting <5% steatosis on MRI. The correlation between CAP and steatosis of available histologic samples had a Pearson correlation coefficient of 0.603 ( P = 0.005). A CAP cutoff of 276.0 dB/m demonstrated 66.7% sensitivity and 85.7% specificity for detecting <15% histopathologic steatosis and positive and negative predictive values of 71.5% and 82.7%, respectively. CONCLUSIONS: VCTE can be integrated into living donor evaluation to accurately screen for hepatic steatosis.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado Gorduroso , Transplante de Fígado , Hepatopatia Gordurosa não Alcoólica , Humanos , Transplante de Fígado/efeitos adversos , Doadores Vivos , Vibração , Fígado Gorduroso/patologia , Curva ROC , Biópsia , Fígado/diagnóstico por imagem , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA