1.
J Pharm Pharm Sci ; 24: 113-126, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33734975

RESUMO

The requirements to waive in vivo bioequivalence studies for immediate release solid oral dosage forms based on the Biopharmaceutics Classifications System (BCS) are well known, and biowaivers[1] for other types of oral dosage forms based on pre-defined criteria may also be acceptable. Similarly, biowaivers for dosage forms such as injectable products may also be allowed if certain criteria are met. The current paper summarises the biowaiver requirements for oral solutions and suspensions, soft gelatin capsules and injectable products (intravenous injections, subcutaneous and intramuscular injections, emulsions for injection and micellar solutions for injection) among the participants of the Bioequivalence Working Group for Generics (BEWGG) of the International Pharmaceutical Regulators Programme (IPRP). A review of the requirements indicated that there was a trend towards convergence when the dosage form became less complex; however, the most common approach used by each of the jurisdictions was a case-by-case approach given that most jurisdictions do not have well defined guidelines to support all possible scenarios. Even in the simplest case of intravenous solutions, the acceptability of qualitative changes in excipients differ between the IPRP members.  Notwithstanding the differences, the dissemination of the information is a first step towards regulatory convergence regarding biowaivers for certain dosage forms and should be useful for pharmaceutical companies currently developing generic medicinal products for IPRP jurisdictions.


Assuntos
Medicamentos Genéricos/administração & dosagem , Administração Oral , Humanos , Soluções , Inquéritos e Questionários , Equivalência Terapêutica
2.
J Pharm Pharm Sci ; 22(1): 486-500, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-33760728

RESUMO

In relation to the registration of generic products, waivers of in vivo bioequivalence studies (biowaivers) are considered in three main cases: certain dosage forms for which bioequivalence is self-evident (e.g. intravenous solutions), biowaivers based on the Biopharmaceutics Classification System and biowaivers for additional strengths with respect to the strength for which in vivo bioequivalence has been shown. The objective of this article is to describe the differences and commonalities in biowaivers for additional strengths of immediate release solid oral dosage forms between the participating members of the International Pharmaceutical Regulators Program (IPRP). The requirements are based on five main aspects; the pharmacokinetics of the drug substance, the manufacturing process, the qualitative and quantitative composition of the different strengths, and the comparative dissolution profiles. For the pharmacokinetic aspects, many regulators/agencies have the same requirements. All strengths must be manufactured with the same process, although a few regulators/agencies accept small differences. In relation to the formulation aspects, the data required breaks down into three major approaches based initially on one of those of the EU, the USA or Japan, but there are some differences in these three major approaches with some country specific interpretations. Most regulators/agencies also have the same requirements for the dissolution data, though there are some notable exceptions.

3.
J Pharm Pharm Sci ; 22(1): 28-36, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30599818

RESUMO

The acceptance of foreign comparator products is the most limiting factor for the development and regulatory assessment of generic medicines marketed globally. Bioequivalence studies have to be repeated with the local comparator products of each jurisdiction because it is unknown if the comparators of the different countries are the same product, with the consequent duplication of efforts by regulators and industry alike. The regulatory requirements on the acceptability of foreign comparator products of oral dosage forms differ between countries participating in the Bioequivalence Working Group for Generics of the International Pharmaceutical Regulators Programme. Brazil, Colombia, the European Union member States, Japan, Mexico, South Korea and the United States only accept bioequivalence studies with their local comparator. In contrast, Australia, Canada, New Zealand, Singapore, South Africa, Switzerland and Taiwan accept studies with foreign comparators under certain conditions. Canada limits its use to highly soluble drugs with a wide therapeutic range in immediate release products. Australia requires a comparison of the quantitative composition. In contrast, there are fewer restrictions on the acceptance of foreign comparators in New Zealand, Singapore, South Africa, Switzerland and Taiwan. For the WHO Prequalification of Medicines and for developing generics of the essential medicines the WHO lists comparators from different countries. In conclusion, there is currently no consensus amongst regulators on the acceptability of foreign comparator products.


Assuntos
Medicamentos Genéricos/farmacocinética , Administração Oral , Humanos , Legislação de Medicamentos , Inquéritos e Questionários , Equivalência Terapêutica
4.
J Pharm Pharm Sci ; 21(1): 27-37, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29382433

RESUMO

PURPOSE: The Biopharmaceutics Classification System (BCS) based biowaiver is a scientific model which enables the substitution of in vivo bioequivalence studies with in vitro data as evidence of therapeutic equivalence subject to certain conditions. Despite being based on the same principles, BCS-based biowaivers are interpreted and regulated differently among international regulatory agencies. In this survey, the Bioequivalence Working Group (BEWG) of the International Generic Drug Regulators Programme (IGDRP) compared the criteria for BCS-based biowaivers applied by the participating regulators and organisations. METHODS: Differences and similarities regarding solubility, permeability, dissolution, excipients and fixed-dose combination products, were identified and compared in a detailed survey of each participant's criteria for BCS-based biowaivers. These criteria were determined based upon the participants' respective regulatory guidance documents, policies and practices. RESULTS: This review has, with the exception of two participants who do not accept BCS-based biowaivers, revealed that most IGDRP participants interpret the BCS principles and conditions similarly but notable differences exist in the application of these principles.  Conclusion: Although many similarities exist, this review identifies several opportunities for greater convergence of regulatory requirements amongst the surveyed jurisdictions. This article is open to POST-PUBLICATION REVIEW. Registered readers (see "For Readers") may comment by clicking on ABSTRACT on the issue's contents page.


Assuntos
Biofarmácia , Cooperação Internacional , Inquéritos e Questionários , Administração Oral , Formas de Dosagem , Humanos