J Am Heart Assoc ; 9(14): e013973, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32646262

RESUMO

Background As transcatheter aortic valve replacement (TAVR) is expected to progress into younger patient populations, valve-in-TAVR (ViTAVR) may become a frequent consideration. Data on ViTAVR, however, are limited. This study investigated the outcome of ViTAVR in comparison to valve in surgical aortic valve replacement (ViSAVR), because ViSAVR is an established procedure for higher-risk patients requiring repeated aortic valve intervention. Methods and Results Clinical and procedural data of patients who underwent ViTAVR at 3 sites in the United States and Germany were retrospectively compared with data of patients who underwent ViSAVR at Cedars-Sinai Medical Center, according to Valve Academic Research Consortium-2 criteria. A total of 99 consecutive patients, 52.5% women, with a median Society of Thoracic Surgeons score of 7.2 were identified. Seventy-four patients (74.7%) underwent ViSAVR, and 25 patients (25.3%) underwent ViTAVR. Balloon-expandable devices were used in 72.7%. ViSAVR patients presented with smaller index devices (21.0 versus 26.0 mm median true internal diameter; P<0.001). Significantly better postprocedural hemodynamics (median prosthesis mean gradient, 12.5 [interquartile range, 8.8-16.2] versus 16.0 [interquartile range, 13.0-20.5] mm Hg; P=0.045) were observed for ViTAVR compared with the ViSAVR. Device success, however, was not different (79.2% and 66.2% for ViTAVR and ViSAVR, respectively; P=0.35), as were rates of permanent pacemaker implantation (16.7% versus 5.4%; P=0.1). One-year-mortality was 9.4% and 13.4% for ViTAVR and ViSAVR, respectively (log-rank P=0.38). Conclusions Compared with ViSAVR, ViTAVR provides acceptable outcomes, with slightly better hemodynamics, similar device success rates, and similar 1-year mortality.


Assuntos
Valva Aórtica , Bioprótese/estatística & dados numéricos , Próteses Valvulares Cardíacas/estatística & dados numéricos , Falha de Prótese , Reoperação/mortalidade , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha/epidemiologia , Hemodinâmica , Humanos , Masculino , Estudos Retrospectivos , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA