Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Hepatology ; 78(3): 820-834, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36988383

RESUMO

BACKGROUND AND AIMS: The scarcity of suitable donor livers highlights a continuing need for innovation to recover organs with reversible injuries in liver transplantation. APPROACH AND RESULTS: Explanted human donor livers (n = 5) declined for transplantation were supported using xenogeneic cross-circulation of whole blood between livers and xeno-support swine. Livers and swine were assessed over 24 hours of xeno-support. Livers maintained normal global appearance, uniform perfusion, and preservation of histologic and subcellular architecture. Oxygen consumption increased by 75% ( p = 0.16). Lactate clearance increased from -0.4 ± 15.5% to 31.4 ± 19.0% ( p = 0.02). Blinded histopathologic assessment demonstrated improved injury scores at 24 hours compared with 12 hours. Vascular integrity and vasoconstrictive function were preserved. Bile volume and cholangiocellular viability markers improved for all livers. Biliary structural integrity was maintained. CONCLUSIONS: Xenogeneic cross-circulation provided multisystem physiological regulation of ex vivo human livers that enabled functional rehabilitation, histopathologic recovery, and improvement of viability markers. We envision xenogeneic cross-circulation as a complementary technique to other organ-preservation technologies in the recovery of marginal donor livers or as a research tool in the development of advanced bioengineering and pharmacologic strategies for organ recovery and rehabilitation.


Assuntos
Transplante de Fígado , Fígado , Humanos , Suínos , Animais , Fígado/patologia , Transplante de Fígado/métodos , Bile , Perfusão/métodos , Preservação de Órgãos/métodos
4.
J Heart Lung Transplant ; 43(2): 293-302, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37907183

RESUMO

BACKGROUND: Right heart failure is the major cause of death in pulmonary hypertension. Lung transplantation is the only long-term treatment option for patients who fail medical therapy. Due to the scarcity of donor lungs, there is a critical need to develop durable mechanical support for the failing right heart. A major design goal for durable support is to reduce the size and complexity of devices to facilitate ambulation. Toward this end, we sought to deploy wearable mechanical support technology in a sheep disease model of chronic right heart failure. METHODS: In 6 sheep with chronic right heart failure, a mechanical support system consisting of an extracorporeal blood pump coupled with a gas exchange unit was attached in a right atrium-to-left atrium configuration for up to 7 days. Circuit performance, hematologic parameters, and animal hemodynamics were analyzed. RESULTS: Six subjects underwent the chronic disease model for 56 to 71 days. Three of the subjects survived to the 7-day end-point for circulatory support. The circuit provided 2.8 (0.5) liter/min of flow compared to the native pulmonary blood flow of 3.5 (1.1) liter/min. The animals maintained physiologically balanced blood gas profile with a sweep flow of 1.2 (1.0) liter/min. Two animals freely ambulated while wearing the circuit. CONCLUSIONS: Our novel mechanical support system provided physiologic support for a large animal model of pulmonary hypertension with right heart failure. The small footprint of the circuit and the low sweep requirement demonstrate the feasibility of this technology to enable mobile ambulatory applications.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Hipertensão Pulmonar , Humanos , Animais , Ovinos , Hipertensão Pulmonar/terapia , Insuficiência Cardíaca/cirurgia , Hemodinâmica/fisiologia , Átrios do Coração
5.
ASAIO J ; 69(2): 167-173, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35544441

RESUMO

Coronavirus disease 2019 (COVID-19) has increased the demand for extracorporeal membrane oxygenation (ECMO) and introduced distinct challenges to patient selection for ECMO. Standardized processes for patient selection amidst resource limitations are lacking, and data on ECMO consults are underreported. We retrospectively reviewed consecutive adult ECMO consults for acute respiratory failure received at a single academic medical center from April 1, 2020, to February 28, 2021, and evaluated the implementation of a multidisciplinary selection committee (ECMO Council) and standardized framework for patient selection for ECMO. During the 334-day period, there were 202 total ECMO consults; 174 (86.1%) included a diagnosis of COVID-19. Among all consults, 157 (77.7%) were declined and 41 (20.3%) resulted in the initiation of ECMO. Frequent reasons for decline included the presence of multiple relative contraindications (n = 33), age greater than 60 years (n = 32), and resource limitations (n = 27). The ECMO Council deliberated on every case in which an absolute contraindication was not present (n = 96) via an electronic teleconference platform. Utilizing multidisciplinary consensus together with a standardized process for patient selection in ECMO is feasible during a pandemic and may be reliably exercised over time. Whether such an approach is feasible at other centers remains unknown.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Adulto , Humanos , Pessoa de Meia-Idade , COVID-19/terapia , Oxigenação por Membrana Extracorpórea/métodos , Estudos Retrospectivos , Seleção de Pacientes , Síndrome do Desconforto Respiratório/terapia
6.
J Appl Physiol (1985) ; 134(4): 840-845, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36759164

RESUMO

Congestive hepatopathy is becoming increasingly recognized among Fontan-palliated patients. Elevated central venous pressure is thought to drive the pathologic progression, characterized by sinusoidal dilatation, congestion, and fibrosis. A clinically relevant large animal model for congestive hepatopathy would provide a valuable platform for researching novel biomarkers, treatment, and prevention. Here, we report on a titratable, sheep pulmonary artery banding model for this disease application. Pulmonary artery banding was achieved by progressively inflating the implanted pulmonary artery cuff. Right ventricular catheter was implanted to draw venous blood samples and measure pressure. The pulmonary artery cuff pressure served as a surrogate for the intensity of pulmonary artery banding and was measured weekly. After about 9 wk, animals were euthanized, and the liver was harvested for histopathological assessment. Nine animal subjects received pulmonary artery banding for 64 ± 8 days. Four of the nine subjects exhibited moderate to severe liver injury, and three of those four exhibited bridging fibrosis. Increasing pulmonary artery cuff pressure significantly correlated with declining mixed venous oxygen saturation (P = 3.29 × 10-5), and higher congestive hepatic fibrosis score (P = 0.0238), suggesting that pulmonary artery banding strategy can be titrated to achieve right-sided congestion and liver fibrosis. Blood analyses demonstrated an increase in plasma bile acids, aspartate aminotransferase, and γ-glutamyltransferase among subjects with moderate to severe injury, further corroborating liver tissue findings. Our large animal pulmonary artery banding model recapitulates congestive hepatopathy and provides a basis to bridge the current gaps in scientific and clinical understanding about the disease.NEW & NOTEWORTHY We present here a large animal platform for congestive hepatopathy, a disease growing in clinical prevalence due to the increasing number of Fontan-palliated patients. Further data are needed to develop a better clinical management strategy for this poorly characterized patient population. Previous reports of animal models to study this disease have mostly been in small animals with limited fidelity. We show that congestive hepatopathy can be replicated in a chronic, progressive pulmonary artery banding model in sheep. We also show that the banding strategy can be controlled to titrate the level of liver injury. To date, we do not know of any other large animal model that can achieve this level of control over disease phenotype and clinical relevance.


Assuntos
Insuficiência Cardíaca , Doenças Vasculares , Animais , Humanos , Fibrose , Cirrose Hepática/patologia , Modelos Animais , Artéria Pulmonar , Ovinos , Modelos Animais de Doenças
7.
J Heart Lung Transplant ; 42(7): 859-867, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36435685

RESUMO

INTRODUCTION: Right ventricular failure (RVF) is a major cause of mortality in pulmonary hypertension (PH). Mechanical circulatory support holds promise for patients with medically refractory PH, but there are no clinical devices for long-term right ventricular (RV) support. Investigations into optimal device parameters and circuit configurations for PH-induced RVF (PH-RVF) are needed. METHODS: Eleven sheep underwent previously published chronic PH model. We then evaluated a low-profile, ventricular assist device (VAD)-quality pump combined with a novel low-resistance membrane oxygenator (Pulmonary Assist Device, PAD) under one of four central cannulation strategies: right atrium-to-left atrium (RA-LA, N = 3), RA-to-pulmonary artery (RA-PA, N=3), pumpless pulmonary artery-to-left atrium (PA-LA, N = 2), and RA-to-ascending aorta (RA-Ao, N = 3). Acute-on-chronic RVF (AoC RVF) was induced, and mechanical support was provided for up to 6 hours at blood flow rates of 1 to 3 liter/min. Circuit parameters, physiologic, hemodynamic, and echocardiography data were collected. RESULTS: The RA-LA configuration achieved blood flow of 3 liter/min. Meanwhile, RA-PA and RA-Ao faced challenges maintaining 3 liter/min of flow due to higher circuit afterload. Pumpless PA-LA was flow-limited due to anatomical limitations inherent to this animal model. RA-LA and RA-Ao demonstrated serial RV unloading with increasing circuit flow, while RA-PA did not. RA-LA also improved left ventricular (LV) and septal geometry by echocardiographic assessment and had the lowest inotropic dependence. CONCLUSION: RA-LA and RA-Ao configurations unload the RV, while RA-LA also lowers pump speed and inotropic requirements, and improves LV mechanics. RA-PA provide inferior support for PH-RVF, while an alternate animal model is needed to evaluate PA-LA.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Hipertensão Pulmonar , Animais , Ovinos , Hipertensão Pulmonar/terapia , Ventrículos do Coração , Átrios do Coração , Hemodinâmica
8.
J Heart Lung Transplant ; 42(3): 335-344, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36456408

RESUMO

BACKGROUND: Xenogeneic cross-circulation (XC) is an experimental method for ex vivo organ support and recovery that could expand the pool of donor lungs suitable for transplantation. The objective of this study was to establish and validate a standardized, reproducible, and broadly applicable technique for performing xenogeneic XC to support and recover injured human donor lungs ex vivo. METHODS: Human donor lungs (n = 9) declined for transplantation were procured, cannulated, and subjected to 24 hours of xenogeneic XC with anesthetized xeno-support swine (Yorkshire/Landrace) treated with standard immunosuppression (methylprednisolone, mycophenolate mofetil, tacrolimus) and complement-depleting cobra venom factor. Standard lung-protective perfusion and ventilation strategies, including periodic lung recruitment maneuvers, were used throughout xenogeneic XC. Every 6 hours, ex vivo donor lung function (gas exchange, compliance, airway pressures, pulmonary vascular dynamics, lung weight) was evaluated. At the experimental endpoint, comprehensive assessments of the lungs were performed by bronchoscopy, histology, and electron microscopy. Student's t-test and 1-way analysis of variance with Dunnett's post-hoc test was performed, and p < 0.05 was considered significant. RESULTS: After 24 hours of xenogeneic XC, gas exchange (PaO2/FiO2) increased by 158% (endpoint: 364 ± 142 mm Hg; p = 0.06), and dynamic compliance increased by 127% (endpoint: 46 ± 20 ml/cmH2O; p = 0.04). Airway pressures, pulmonary vascular pressures, and lung weight remained stable (p > 0.05) and within normal ranges. Over 24 hours of xenogeneic XC, gross and microscopic lung architecture were preserved: airway bronchoscopy and parenchymal histomorphology appeared normal, with intact blood-gas barrier. CONCLUSIONS: Xenogeneic cross-circulation is a robust method for ex vivo support, evaluation, and improvement of injured human donor lungs declined for transplantation.


Assuntos
Transplante de Pulmão , Humanos , Suínos , Animais , Transplante de Pulmão/métodos , Pulmão , Perfusão/métodos , Doadores de Tecidos , Preservação de Órgãos/métodos
9.
Sci Adv ; 9(13): eade7647, 2023 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-37000867

RESUMO

Improved approaches to expanding the pool of donor lungs suitable for transplantation are critically needed for the growing population with end-stage lung disease. Cross-circulation (XC) of whole blood between swine and explanted human lungs has previously been reported to enable the extracorporeal recovery of donor lungs that declined for transplantation due to acute, reversible injuries. However, immunologic interactions of this xenogeneic platform have not been characterized, thus limiting potential translational applications. Using flow cytometry and immunohistochemistry, we demonstrate that porcine immune cell and immunoglobulin infiltration occurs in this xenogeneic XC system, in the context of calcineurin-based immunosuppression and complement depletion. Despite this, xenogeneic XC supported the viability, tissue integrity, and physiologic improvement of human donor lungs over 24 hours of xeno-support. These findings provide targets for future immunomodulatory strategies to minimize immunologic interactions on this organ support biotechnology.


Assuntos
Transplante de Pulmão , Pulmão , Humanos , Suínos , Animais , Terapia de Imunossupressão
10.
ASAIO J ; 68(8): 1002-1009, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35507443

RESUMO

Refractory hypoxemia despite the use of extracorporeal membrane oxygenation (ECMO) for coronavirus disease 2019 (COVID-19)-related acute respiratory distress syndrome remains a challenging problem. A single ECMO circuit may not provide adequate physiologic support in the setting of an elevated cardiac output, physiologic demand, and impaired gas exchange. In select patients with refractory hypoxemia, addition of a second ECMO circuit in parallel can improve oxygenation, facilitate lung protective ventilation, awakening, and physical rehabilitation. We report the largest case series to date of patients receiving ECMO circuits in parallel and the first to report this approach in COVID-19.


Assuntos
COVID-19/complicações , Oxigenação por Membrana Extracorpórea , Hipóxia/terapia , Síndrome do Desconforto Respiratório/terapia , Humanos , Hipóxia/etiologia , Respiração Artificial , Síndrome do Desconforto Respiratório/etiologia
11.
Transplant Rev (Orlando) ; 36(2): 100693, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35413506

RESUMO

BACKGROUND: Isolated cases of extracorporeal membrane oxygenation (ECMO) in patients with hepatopulmonary syndrome (HPS) undergoing liver transplantation (LT) have been reported with increasing frequency. We aimed to systemically review and synthesize the available literature on ECMO use in this population. METHODS: A systematic literature review of the PubMed, Web of Science, Cochrane Library, and Embase databases (end-of-search date: November 14, 2021) was conducted in accordance with the PRISMA statement. Eligible studies presented clinical parameters and outcomes of adult or pediatric patients with HPS receiving ECMO support at the time of, or following, LT. RESULTS: Sixteen studies from 4 continents reporting on 17 patients who were initiated on ECMO prior to (n = 2), during (n = 1) or after LT (n = 14) were included. Nine of the 16 studies were published between 2019 and 2021. The median pre-LT PaO2 was 38.0 mmHg (IQR 35.0-52.0). The median time from LT to ECMO initiation was 7 days (IQR, 3-12). Six patients (50%, n = 6 of 12) were extubated post-LT, before deterioration, development of refractory hypoxemia, and initiation of ECMO. Most patients were cannulated with a venovenous configuration (75%, n = 12 of 16). Most patients cannulated with a venoarterial or veno-arterial-venous strategy (75%, n = 3 of 4) had concurrent hemodynamic instability. The median total time on ECMO was 13 days (IQR 10-29). Using linear regression, for patients cannulated postoperatively, each day between LT and ECMO initiation was associated with a 3.5-day increase in total ECMO duration (95%CI: 2.23-4.73, p < 0.001, R2 = 73.7%). The median postoperative intensive care unit length of stay was 40 days (IQR, 37-61) and hospital length of stay was 59.5 days (IQR 42-77). 82.4% of patients (14 of 17) survived to discharge. CONCLUSIONS: ECMO is feasible in patients with HPS undergoing LT and appears to be associated with better outcomes compared to other causes of cardiopulmonary failure in LT patients. As the volume of experience grows, ECMO may become a central part of perioperative support in LT patients with severe HPS.


Assuntos
Oxigenação por Membrana Extracorpórea , Síndrome Hepatopulmonar , Transplante de Fígado , Adulto , Criança , Oxigenação por Membrana Extracorpórea/efeitos adversos , Síndrome Hepatopulmonar/etiologia , Síndrome Hepatopulmonar/cirurgia , Humanos , Transplante de Fígado/efeitos adversos
12.
J Am Assoc Lab Anim Sci ; 61(1): 101-104, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34879898

RESUMO

Swine (Sus scrofa domesticus) are commonly used large animal subjects for the study of disease and preclinical therapies. Organ machine perfusion is a therapy that has gained momentum as a research platform for the study of ex vivo organ preservation and therapeutics. However, complex perfusion circuits and research protocols often require large volumes of blood as perfusate. Here, we report a technique for increasing terminal blood yield during swine organ and blood procurement; our method involves acute normovolemic hemodilution and exsanguination via the femoral artery. We collected a total of 47 ± 4 mL/kg of blood and 4.3 ± 0.6 g/kg of hemoglobin, representing 73% ± 6% of the estimated blood volume and 64% ± 8% of the total estimated intravascular hemoglobin (n = 4). Neither pH, lactate, nor pO2 levels changed significantly during blood procurement. Acute normovolemic hemodilution is an effective method for increasing RBC and hemoglobin yield during blood procurement in swine.


Assuntos
Volume Sanguíneo , Hemodiluição , Animais , Hemodiluição/métodos , Hemodiluição/veterinária , Hemoglobinas , Humanos , Perfusão/veterinária , Cuidados Pré-Operatórios , Suínos
13.
Artigo em Inglês | MEDLINE | ID: mdl-36270862

RESUMO

OBJECTIVES: Refractory hypoxemia can occur in patients with acute respiratory distress syndrome from COVID-19 despite support with venovenous (VV) extracorporeal membrane oxygenation (ECMO). Parallel ECMO circuits can be used to increase physiologic support. We report our clinical experience using ECMO circuits in parallel for select patients with persistent severe hypoxemia despite the use of a single ECMO circuit. METHODS: We performed a retrospective cohort study of all patients with COVID-19-related acute respiratory distress syndrome who received VV-ECMO with an additional circuit in parallel at Vanderbilt University Medical Center between March 1, 2020, and March 1, 2022. We report demographic characteristics and clinical characteristics including ECMO settings, mechanical ventilator settings, use of adjunctive therapies, and arterial blood gas results after initial cannulation, before and after receipt of a second ECMO circuit in parallel, and before removal of the circuit in parallel, and outcomes. RESULTS: Of 84 patients with COVID-19 who received VV-ECMO during the study period, 22 patients (26.2%) received a circuit in parallel. The median duration of ECMO was 40.0 days (interquartile range, 31.6-53.1 days), of which 19.0 days (interquartile range, 13.0-33.0 days) were spent with a circuit in parallel. Of the 22 patients who received a circuit in parallel, 16 (72.7%) survived to hospital discharge and 6 (27.3%) died before discharge. CONCLUSIONS: In select patients, the additional use of an ECMO circuit in parallel can increase ECMO blood flow and improve oxygenation while allowing for lung-protective mechanical ventilation and excellent outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA