Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 147
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(3): 379-388, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38185855

RESUMO

BACKGROUND: The mechanism of typical slow-fast atrioventricular nodal re-entrant tachycardia (AVNRT) and its anatomical and electrophysiological circuit inside the right atrium (RA) and Koch's Triangle (KT) are not well known. OBJECTIVE: To identify the potentials of the compact AV node and inferior extensions and to perform accurate mapping of the RA and KT in sinus rhythm (SR) and during AVNRT, to define the tachycardia circuit. METHODS: Consecutive patients with typical AVNRT were enrolled in 12 Italian centers and underwent mapping and ablation by means of a basket catheter with small electrode spacing for ultrahigh-density mapping and a modified signal-filtering toolset to record the potentials of the AV nodal structures. RESULTS: Forty-five consecutive cases of successful ablation of typical slow-fast AVNRT were included. The mean SR cycle length (CL) was 784.1 ± 6 ms and the mean tachycardia CL was 361.2 ± 54 ms. The AV node potential had a significantly shorter duration and higher amplitude in sinus rhythm than during tachycardia (60 ± 40 ms vs. 160 ± 40 ms, p < .001 and 0.3 ± 0.2 mV vs. 0.09 ± 0.12 mV, p < .001, respectively). The nodal potential duration extension was 169.4 ± 31 ms, resulting in a time-window coverage of 47.6 ± 9%. The recording of AV nodal structure potentials enabled us to obtain 100% coverage of the tachycardia CL during slow-fast AVNRT. CONCLUSION: Detailed recording of the potentials of nodal structures is possible by means of multipolar catheters for ultrahigh-density mapping, allowing 100% of the AVNRT CL to be covered. These results also have clinical implications for the ablation of right-septal and para-septal arrhythmias.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Nó Atrioventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Eletrodos
2.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38938169

RESUMO

AIMS: Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, closed loop stimulation (CLS) integrated into the circulatory control system through intra-cardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared with conventional DDDR pacing. METHODS AND RESULTS: Patients with sinus node dysfunctions (SNDs) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n = 612) or accelerometer-based DDDR pacing (n = 598) and followed for 3 years. The primary endpoint was time to the composite endpoint of the first AHRE lasting ≥6 min, stroke, or transient ischaemic attack (TIA). All AHREs were independently adjudicated using intra-cardiac electrograms. The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 h and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS vs. DDDR was 0.84 [95% confidence interval (CI), 0.72-0.99; P = 0.035]. After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95% CI, 0.71-0.99; P = 0.033). In subgroup analyses of AHRE incidence, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.77; P = 0.008) and in patients without AF history (HR, 0.73; P = 0.009). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms. CONCLUSION: Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.


Assuntos
Fibrilação Atrial , Estimulação Cardíaca Artificial , Frequência Cardíaca , Ataque Isquêmico Transitório , Marca-Passo Artificial , Síndrome do Nó Sinusal , Acidente Vascular Cerebral , Humanos , Feminino , Masculino , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Idoso , Síndrome do Nó Sinusal/terapia , Síndrome do Nó Sinusal/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Ataque Isquêmico Transitório/prevenção & controle , Ataque Isquêmico Transitório/epidemiologia , Pessoa de Meia-Idade , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Incidência , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Acelerometria , Idoso de 80 Anos ou mais
3.
J Cardiovasc Electrophysiol ; 34(6): 1386-1394, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37194742

RESUMO

INTRODUCTION: Brugada syndrome (BrS) has a dynamic ECG pattern that might be revealed by certain conditions such as fever. We evaluated the incidence and management of ventricular arrhythmias (VAs) related to COVID-19 infection and vaccination among BrS patients carriers of an implantable loop recorder (ILR) or implantable cardioverter-defibrillator (ICD) and followed by remote monitoring. METHODS: This was a multicenter retrospective study. Patients were carriers of devices with remote monitoring follow-up. We recorded VAs 6 months before COVID-19 infection or vaccination, during infection, at each vaccination, and up to 6-month post-COVID-19 or 1 month after the last vaccination. In ICD carriers, we documented any device intervention. RESULTS: We included 326 patients, 202 with an ICD and 124 with an ILR. One hundred and nine patients (33.4%) had COVID-19, 55% of whom developed fever. Hospitalization rate due to COVID-19 infection was 2.76%. After infection, we recorded only two ventricular tachycardias (VTs). After the first, second, and third vaccines, the incidence of non-sustained ventricular tachycardia (NSVT) was 1.5%, 2%, and 1%, respectively. The incidence of VT was 1% after the second dose. Six-month post-COVID-19 healing or 1 month after the last vaccine, we documented NSVT in 3.4%, VT in 0.5%, and ventricular fibrillation in 0.5% of patients. Overall, one patient received anti-tachycardia pacing and one a shock. ILR carriers had no VAs. No differences were found in VT before and after infection and before and after each vaccination. CONCLUSIONS: From this large multicenter study conducted in BrS patients, followed by remote monitoring, the overall incidence of sustained VAs after COVID-19 infection and vaccination is relatively low.


Assuntos
Síndrome de Brugada , COVID-19 , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/terapia , Estudos Retrospectivos , Incidência , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Sistema de Registros , Vacinação , Seguimentos
4.
Eur J Clin Invest ; 53(6): e13969, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36776121

RESUMO

BACKGROUND AND AIMS: Transvenous lead extraction (TLE) has become a pivotal part of a comprehensive lead management strategy, dealing with a continuously increasing demand. Nonetheless, the literature about the long-term impact of TLE on survivals is still lacking. Given these knowledge gaps, the aim of our study was to analyse very long-term mortality in patients undergoing TLE in public health perspective. METHODS: This prospective, single-centre, observational study enrolled consecutive patients with cardiac implantable electronic device (CIED) who underwent TLE, from January 2005 to January 2021. The main goal was to establish the independent predictors of very long-term mortality after TLE. We also aimed at assessing procedural and hospitalization-related costs. RESULTS: We enrolled 435 patients (mean age 70 ± 12 years, with mean lead dwelling time 6.8 ± 16.7 years), with prevalent infective indication to TLE (92%). Initial success of TLE was achieved in 98% of population. After a median follow-up of 4.5 years (range: 1 month-15.5 years), 150 of the 435 enrolled patients (34%) died. At multivariate analysis, death was predicted by: age (≥77 years, OR: 2.55, CI: 1.8-3.6, p < 0.001), chronic kidney disease (CKD) defined as severe reduction of estimated glomerular filtration rate (eGFR <30 mL/min/1.73 m2 , OR: 1.75, CI: 1.24-2.4, p = 0.001) and systolic dysfunction assessed before TLE defined as left ventricular ejection fraction (LVEF) <40%, OR: 1.78, CI 1.26-2.5, p = 0.001. Mean extraction cost was €5011 per patient without reimplantation and €6336 per patient with reimplantation respectively. CONCLUSIONS: Our study identified three predictors of long-term mortality in a high-risk cohort of patients with a cardiac device infection, undergoing successful TLE. The future development of a mortality risk score before might impact on public health strategy.


Assuntos
Desfibriladores Implantáveis , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos
5.
Pacing Clin Electrophysiol ; 46(11): 1302-1309, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37846769

RESUMO

INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Criocirurgia/métodos , Itália/epidemiologia , Sistema de Registros , Ablação por Cateter/métodos , Recidiva
6.
Europace ; 24(7): 1127-1136, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35138367

RESUMO

AIMS: The aims of this study is to assess by an updated meta-analysis the clinical outcomes related to permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) at long-term (≥12 months) follow-up (LTF). METHODS AND RESULTS: A comprehensive literature research was performed on PubMed and EMBASE. The primary endpoint was all-cause death. Secondary endpoints were rehospitalization for heart failure, stroke, and myocardial infarction. A subgroup analysis was performed according to the Society of Thoracic Surgeon-Predicted Risk of Mortality (STS-PROM) score. This study is registered with PROSPERO (CRD42021243301). A total of 51 069 patients undergoing TAVI from 31 observational studies were included. The mean duration of follow-up was 22 months. At LTF, PPI post-TAVI was associated with a higher risk of all-cause death [risk ratio (RR) 1.18, 95% confidence interval (CI) 1.10-1.25; P < 0.001] and rehospitalization for heart failure (RR 1.32, 95% CI 1.13-1.52; P < 0.001). In contrast, the risks of stroke and myocardial infarction were not affected. Among the 20 studies that reported procedural risk, the association between PPI and all-cause death risk at LTF was statistically significant only in studies enrolling patients with high STS-PROM score (RR 1.25, 95% CI 1.12-1.40), although there was a similar tendency of the results in those at medium and low risk. CONCLUSION: Patients necessitating PPI after TAVI have a higher long-term risk of all-cause death and rehospitalization for heart failure as compared to those who do not receive PPI.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Marca-Passo Artificial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 32(6): 1540-1548, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33851484

RESUMO

BACKGROUND: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. METHODS: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. RESULTS: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p < .0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p < .0001 for LI; 0.73 [0.41-1.25] Ω/s vs. 0.35[0.22-0.59 Ω/s, p < .0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. CONCLUSION: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
8.
Heart Fail Rev ; 26(2): 227-235, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32974722

RESUMO

Heart failure is the cardiovascular epidemic of the twenty-first century, with poor prognosis and quality of life despite optimized medical treatment. Despite over the last decade significant improvements, with a major impact on morbidity and mortality, have been made in therapy for heart failure with reduced ejection fraction, little progress was made in the development of devices, with the implantable defibrillator indicated for patients with left ventricle ejection fraction ≤ 35% and cardiac resynchronization therapy for those with QRS ≥ 130 ms and evidence of left bundle branch block. Nevertheless, only a third of patients meet these criteria and a high percentage of patients are non-responders in terms of improving symptoms. Nowadays, in patients with symptomatic heart failure with ejection fraction between 25% and 45% and QRS < 130 ms, not eligible for cardiac resynchronization, the cardiac contractility modulation (CCM) represents a concrete therapeutic option, having proved to be safe and effective in reducing hospitalizations for heart failure and improving symptoms, functional capacity, and quality of life. The aim of this review is therefore to summarize the pathophysiological mechanisms, the current indications, and the recent developments regarding the new applications of the CCM for patients with chronic heart failure.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Insuficiência Cardíaca/terapia , Humanos , Contração Miocárdica , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 44(10): 1657-1662, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34314032

RESUMO

BACKGROUND: Sleep apnea syndrome (SAS) has been reported to be associated with a higher incidence of ventricular arrhythmias. The aim of this study was twofold: (1) to investigate whether in SAS patients receiving an implantable cardioverter defibrillator (ICD) the severity of SAS was associated with the occurrence of ventricular arrhythmias; (2) to assess whether changes in nocturnal apnoic/hypopnoic episodes may favor the occurrence of life-threatening arrhythmias, that is, sustained ventricular tachycardia (VT)/fibrillation (VF), requiring ICD intervention. METHODS: We enrolled 46 patients with documented SAS at polysomnography (apnea/hypopnea index [AHI] > 5) who also had a left ventricle ejection fraction (LVEF) < 35% and, according to primary prevention indications, implanted an ICD (Boston Scientific Incepta) able to daily monitor apnoic/hypopnoic episodes occurring during sleep. Patients were followed at 3-month intervals. RESULTS: At a mean follow-up of 18 months, 21 episodes of sustained VT/FV requiring ICD intervention were documented in eight patients (17.4%). Baseline AHI was significantly higher in patients with compared to those without ICD intervention. ICD interventions, however, were not preceded by any worsening of apnoic/hypopnoic episodes. The respiratory disturbance index (RDI) of the week during the event, indeed, was not different from that recorded during the previous 2 weeks (25.4 ± 11, 25.6 ± 10 and 25.1 ± 10, respectively; p = .9). CONCLUSIONS: In patients with SAS who received an ICD for primary prevention of sudden death, those with ICD interventions showed a more severe form of the disease at baseline. ICD interventions, however, were not preceded by any significant changes in SAS severity.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Síndromes da Apneia do Sono/fisiopatologia , Taquicardia Ventricular/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Polissonografia , Prevenção Primária , Fatores de Risco , Índice de Gravidade de Doença , Taquicardia Ventricular/epidemiologia
10.
Pacing Clin Electrophysiol ; 44(12): 2031-2040, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34606098

RESUMO

BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros
11.
Medicina (Kaunas) ; 57(1)2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33445447

RESUMO

Background and objectives: An Italian nationwide pre-participation screening approach for prevention of sudden cardiac death in athletes (SCD-A) in competitive sportspeople showed promising results but did not achieve international consensus, due to cost-effectiveness and the shortfall of a monitoring plan. From this perspective, we tried to provide an epidemiological update of SCD-A in Italy through a year-long internet-based search. Materials and Methods: One year-long Google search was performed using mandatory and non-mandatory keywords. Data were collected according to prevalent SCD-A definition and matched with sport-related figures from Italian National Institute of Statistics (ISTAT) and Italian National Olympic Committee (CONI). Results: Ninety-eight cases of SCD-A in 2019 were identified (48.0% competitive, 52.0% non-competitive athletes). Male/female ratio was 13:1. The most common sports were soccer (33.7%), athletics (15.3%) and fitness (13.3%). A conclusive diagnosis was achieved only in 37 cases (33 of cardiac origin), with the leading diagnosis being coronary artery disease in 27 and a notably higher occurrence among master athletes. Combining these findings with ISTAT and CONI data, the SCD-A incidence rate in the whole Italian sport population was found to be 0.47/100,000 persons per year (1.00/100,000 in the competitive and 0.32/100,000 in the non-competitive population). The relative risk of SCD-A is 3.1 (CI 2.1-4.7; p < 0.0001) for competitive compared to non-competitive athletes; 9.9 for male (CI 4.6-21.4; p < 0.0001) with respect to female. Conclusions: We provided an updated incidence rate of SCD-A in both competitive and non-competitive sport in Italy. A higher risk of SCD-A among competitive and male athletes was confirmed, thus corroborating the value of Italian pre-participation screening in this population.


Assuntos
Morte Súbita Cardíaca , Esportes , Atletas , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Incidência , Internet , Itália/epidemiologia , Masculino
12.
Medicina (Kaunas) ; 57(2)2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33672601

RESUMO

The diagnosis of structural heart disease in athletes with ventricular arrhythmias (VAs) and an apparently normal heart can be very challenging. Several pieces of evidence demonstrate the importance of an extensive diagnostic work-up in apparently healthy young patients for the characterization of concealed cardiomyopathies. This study shows the various diagnostic levels and tools to help identify which athletes need deeper investigation in order to unmask possible underlying heart disease.


Assuntos
Cardiomiopatias , Cardiopatias , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Atletas , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Humanos , Fluxo de Trabalho
13.
J Cardiovasc Electrophysiol ; 31(9): 2319-2327, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32613661

RESUMO

INTRODUCTION: Recently, a novel technology able to measure local impedance (LI) and tissue characteristics has been made available for clinical use. This analysis explores the relationships among LI and generator impedance (GI) parameters in atrial fibrillation (AF) patients. Characterization of LI among different ablation spots and procedural success were also evaluated. METHODS AND RESULTS: Consecutive patients undergoing AF ablation from the CHARISMA registry at five Italian centers were included. A novel radiofrequency (RF) ablation catheter with a dedicated algorithm (DIRECTSENSE™) was used to measure LI and to guide ablation. The ablation endpoint was pulmonary vein (PV) isolation. We analyzed 2219 ablation spots created around PVs in 46 patients for AF ablation. The mean baseline tissue impedance was 105.8 ± 14 Ω for LI versus 91.8 ± 10 Ω for GI (p < .0001). Baseline impedance was homogenous across the PV sites and proved higher in high-voltage areas than in intermediate- and low-voltage areas and the blood pool (p < .001). Both LI and GI displayed a significant drop after RF delivery, and absolute LI drop values were significantly larger than GI drop values (14 ± 8 vs. 3.7 ± 5 Ω, p < .0001). Every 5-point increment in LI drop was associated with successful ablation (odds ratio = 3.05, 95% confidence interval: 2.3-4.1, p < .0001). Conversely, GI drops were not significantly different comparing successful versus unsuccessful sites (3.7 ± 5 vs. 2.8 ± 4 Ω, p = .1099). No steam pops or major complications occurred during or after the procedures. By the end of the procedures, all PVs had been successfully isolated in all patients. CONCLUSIONS: The magnitude of the LI drop was more closely associated with effective lesion formation than the GI drop.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Humanos , Projetos Piloto , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
14.
BMC Cardiovasc Disord ; 20(1): 156, 2020 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-32248794

RESUMO

BACKGROUND: Danon disease (OMIM 300257) is an X-linked lysosomal storage disorder, characterized by hypertrophic cardiomyopathy (HCM), skeletal myopathy, variable intellectual disability, and other minor clinical features. This condition accounts for ~ 4% of HCM patients, with a more severe and early onset phenotype in males, causing sudden cardiac death (SCD) in the first three decades of life. Genetic alterations in the LAMP2 gene are the main cause of this inherited fatal condition. Up to date, more than 100 different pathogenic variants have been reported in the literature. However, the majority of cases are misdiagnosed as HCM or have a delay in the diagnosis. CASE PRESENTATION: Here, we describe a young boy with an early diagnosis of HCM. After 2 episodes of ventricular fibrillation within 2 years, genetic testing identified a novel LAMP2 pathogenic variant. Subsequently, further clinical evaluations showing muscle weakness and mild intellectual disability confirmed the diagnosis of Danon disease. CONCLUSIONS: This report highlights the role of genetic testing in the rapid diagnosis of Danon disease, underscoring the need to routinely consider the inclusion of LAMP2 gene in the genetic screening for HCM, since an early diagnosis of Danon disease in patients with a phenotype mimicking HCM is essential to plan appropriate treatment, ie cardiac transplantation.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Análise Mutacional de DNA , Testes Genéticos , Doença de Depósito de Glicogênio Tipo IIb/diagnóstico , Proteína 2 de Membrana Associada ao Lisossomo/genética , Mutação , Adolescente , Erros de Diagnóstico , Diagnóstico Precoce , Predisposição Genética para Doença , Doença de Depósito de Glicogênio Tipo IIb/diagnóstico por imagem , Doença de Depósito de Glicogênio Tipo IIb/genética , Humanos , Masculino , Fenótipo , Valor Preditivo dos Testes
15.
J Electrocardiol ; 59: 147-150, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32120081

RESUMO

INTRODUCTION: Implantable cardiac monitor (ICM) is an established tool for the management of unexplained syncope and atrial fibrillation (AF) even if its accuracy of arrhythmia detection may be suboptimal. The aim of this study was to perform an intra-patient comparison of the diagnostic capability of ICM with a dual-chamber PM as a gold standard. METHODS: We included 19 patients with a previously implanted ICM (BioMonitor 2 Biotronik, Berlin, Germany), who received a dual-chamber PM for standard indications. ICM-detected arrhythmic events in a 6-month follow-up were compared with those detected by the PM and classified by visual inspection of intracardiac electrograms. RESULTS: During follow up, ICMs generated 15 false asystole and 39 false bradycardia detections in 5 patients (26.3%) due to recurrent premature ventricular contractions. A total of 34 true high ventricular rate (HVR) episodes were detected by the PM. Of them, 30 (88%) events were also recorded by the ICM, which further detected 14 false HVR snapshots, leading to a sensitivity and positive predictive value of 88% and 68%, respectively. In addition, PM identified 234 true AF episodes. Of them, 225 (96%) events were also detected by the ICM, while 8 (42%) ICMs stored 50 AF episodes classified as false positives. The ICM sensitivity for AF was 96% with a positive predictive value of 82%. CONCLUSION: Our intra-patient comparison with permanent PM confirmed that ICM is an effective tool for cardiac arrhythmias detection. ICM algorithms for AF and HVR detection were highly sensitive with an acceptable rate of false positive episodes.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Alemanha , Humanos
17.
Circulation ; 133(17): 1637-44, 2016 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-27029350

RESUMO

BACKGROUND: Whether catheter ablation (CA) is superior to amiodarone (AMIO) for the treatment of persistent atrial fibrillation (AF) in patients with heart failure is unknown. METHODS AND RESULTS: This was an open-label, randomized, parallel-group, multicenter study. Patients with persistent AF, dual-chamber implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator, New York Heart Association II to III, and left ventricular ejection fraction <40% within the past 6 months were randomly assigned (1:1 ratio) to undergo CA for AF (group 1, n=102) or receive AMIO (group 2, n=101). Recurrence of AF was the primary end point. All-cause mortality and unplanned hospitalization were the secondary end points. Patients were followed up for a minimum of 24 months. At the end of follow-up, 71 (70%; 95% confidence interval, 60%-78%) patients in group 1 were recurrence free after an average of 1.4±0.6 procedures in comparison with 34 (34%; 95% confidence interval, 25%-44%) in group 2 (log-rank P<0.001). The success rate of CA in the different centers after a single procedure ranged from 29% to 61%. After adjusting for covariates in the multivariable model, AMIO therapy was found to be significantly more likely to fail (hazard ratio, 2.5; 95% confidence interval, 1.5-4.3; P<0.001) than CA. Over the 2-year follow-up, the unplanned hospitalization rate was (32 [31%] in group 1 and 58 [57%] in group 2; P<0.001), showing 45% relative risk reduction (relative risk, 0.55; 95% confidence interval, 0.39-0.76). A significantly lower mortality was observed in CA (8 [8%] versus AMIO (18 [18%]; P=0.037). CONCLUSIONS: This multicenter randomized study shows that CA of AF is superior to AMIO in achieving freedom from AF at long-term follow-up and reducing unplanned hospitalization and mortality in patients with heart failure and persistent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00729911.


Assuntos
Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
Europace ; 19(3): 432-440, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27025772

RESUMO

AIMS: The number of cardiovascular implantable electronic devices has increased progressively, leading to an increased need for transvenous lead extraction (TLE) due to device infections. Previous studies described 'ghost' as a post-removal, new, tubular, mobile mass detected by echocardiography following the lead's intracardiac route in the right-sided heart chambers, associated with diagnosis of cardiac device-related infective endocarditis. We aimed to analyse the association between 'ghosts' assessed by transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE) and mortality in patients undergoing TLE. METHODS AND RESULTS: We prospectively enrolled 217 patients (70 ± 13 years; 164 males) undergoing TLE for systemic infection (139), local device infection (67), and lead malfunction (11). All patients underwent TEE before and 48 h after TLE and ICE during TLE. Patients were allocated to two groups: either with (Group 1) or without (Group 2) post-procedural 'ghost'. Mid-term clinical follow-up was obtained in all patients (11 months, IQR 1-34 months). We identified 30 (14%) patients with 'ghost', after TLE. The significant predictors of 'ghost' were Charlson co-morbidity index (HR = 1.24, 95% CI 1.04-1.48, P = 0.03) and diagnosis of endocarditis assessed by ICE (HR = 1.82, 95% CI 1.01-3.29, P = 0.04). Mortality was higher in Group 1 than in Group 2 (28 vs. 5%; log-rank P < 0.001). Independent predictors of mid-term mortality were the presence of 'ghost' and systemic infection as the clinical presentation of device infection (HR = 3.47, 95% CI 1.18-10.18, P = 0.002; HR = 3.39, 95% CI 1.15-9.95, P = 0.001, respectively). CONCLUSION: The presence of 'ghost' could be an independent predictor of mortality after TLE, thus identifying a subgroup of patients who need closer clinical surveillance to promptly detect any complications.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/mortalidade , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/mortalidade , Falha de Prótese , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Europace ; 18(10): 1565-1572, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26559916

RESUMO

AIMS: Aim of this study was to compare a minimally fluoroscopic radiofrequency catheter ablation with conventional fluoroscopy-guided ablation for supraventricular tachycardias (SVTs) in terms of ionizing radiation exposure for patient and operator and to estimate patients' lifetime attributable risks associated with such exposure. METHODS AND RESULTS: We performed a prospective, multicentre, randomized controlled trial in six electrophysiology (EP) laboratories in Italy. A total of 262 patients undergoing EP studies for SVT were randomized to perform a minimally fluoroscopic approach (MFA) procedure with the EnSiteTMNavXTM navigation system or a conventional approach (ConvA) procedure. The MFA was associated with a significant reduction in patients' radiation dose (0 mSv, iqr 0-0.08 vs. 8.87 mSv, iqr 3.67-22.01; P < 0.00001), total fluoroscopy time (0 s, iqr 0-12 vs. 859 s, iqr 545-1346; P < 0.00001), and operator radiation dose (1.55 vs. 25.33 µS per procedure; P < 0.001). In the MFA group, X-ray was not used at all in 72% (96/134) of cases. The acute success and complication rates were not different between the two groups (P = ns). The reduction in patients' exposure shows a 96% reduction in the estimated risks of cancer incidence and mortality and an important reduction in estimated years of life lost and years of life affected. Based on economic considerations, the benefits of MFA for patients and professionals are likely to justify its additional costs. CONCLUSION: This is the first multicentre randomized trial showing that a MFA in the ablation of SVTs dramatically reduces patients' exposure, risks of cancer incidence and mortality, and years of life affected and lost, keeping safety and efficacy. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01132274.


Assuntos
Ablação por Cateter , Fluoroscopia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Exposição à Radiação , Taquicardia Supraventricular/cirurgia , Adulto , Mapeamento Potencial de Superfície Corporal , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Supraventricular/mortalidade , Resultado do Tratamento
20.
Circ J ; 80(3): 613-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26821688

RESUMO

BACKGROUND: Not all heart failure (HF) patients benefit from cardiac resynchronization therapy (CRT). We assessed whether choosing the site of left ventricular (LV) pacing by a quadripolar lead may improve response to CRT. METHODS AND RESULTS: We prospectively randomized 23 patients with HF (67±11 years; 21 males) to CRT with a quadripolar LV lead (group 1, with the LV pacing site chosen on the basis of QRS shortening using simultaneous biventricular pacing), and 20 patients (71±6 years; 16 males) to a bipolar LV lead (group 2, with devices programmed with a conventional tip-to-ring configuration). New York Heart Association (NYHA) class and LV ejection fraction (EF) by 2D echocardiography were assessed at baseline and after 3 months. The baseline EF was not different between the 2 groups (25±6% group 1 vs. 27±3% group 2; P=0.22), but after 3 months EF was higher in group 1 (35±13% group 1 vs. 31±4% group 2; P<0.001). A reduction in at least 1 NYHA class at 3 months was observed in 22 (96%) and 12 (60%) of group 1 and group 2 patients, respectively (P<0.05). CONCLUSIONS: CRT with a quadripolar LV lead was associated with an improvement of EF greater than that observed in patients receiving a bipolar LV lead. In devices with a quadripolar lead, CRT programming based on the best QRS shortening is reliable and effective. (Circ J 2016; 80: 613-618).


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA