Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Echocardiography ; 41(1): e15698, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284664

RESUMO

BACKGROUND: Transaortic valve implant (TAVI) is the treatment of choice for severe aortic stenosis (AS). Some patients develop prosthesis patient mismatch (PPM) after TAVI. It is challenging to determine which patients are at risk for clinical deterioration. METHODS: We retrospectively measured echocardiographic parameters of left ventricular (LV) morphology and function, prosthetic aortic valve effective orifice area (iEOA) and hemodynamics in 313 patients before and 1 year after TAVI. Our objective was to compare the change in echocardiographic parameters associated with left ventricular reverse modeling in subjects with and without PPM. Our secondary objective was to evaluate echo parameters associated with PPM and the relationship to patient functional status and survival post-TAVI. RESULTS: We found that 82 (26.2%) of subjects had moderate and 37 (11.8%) had severe PPM post-TAVI. There was less relative improvement in LVEF with PPM (1.9 ± 21.3% vs. 8.2 + 30.1%, p = .045). LV GLS also exhibited less relative improvement in those with PPM (13.4 + 34.1% vs. 30.9 + 73.3%, p = .012). NYHA functional class improved in 84.3% of subjects by one grade or more. Echocardiographic markers of PPM were worse in those without improvement in NYHA class (mean AT/ET was .29 vs. .27, p = .05; DVI was .46 vs. .51, p = .021; and iEOA was .8 cm/m2 vs. .9 cm/m2 , p = .025). There was no association with PPM and survival. CONCLUSIONS: There was no improvement in LVEF and less improvement in LV GLS in those with PPM post-TAVI. Echocardiographic markers of PPM were present in those with lack of improvement in NYHA functional class.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Remodelação Ventricular , Resultado do Tratamento , Ecocardiografia
2.
Echocardiography ; 40(6): 592-595, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37158184

RESUMO

BACKGROUND: Left atrial (LA) volume is related to LA reservoir strain (LASR ), but the relationship is not fully resolved. We sought to model the relationship between LA end-diastolic and end-systolic volumes (LAEDV and LAESV) and LASR based on a geometrical approach to exploit the relationship between LASR and volume. METHODS: Modeling the LA as a hemisphere with radius r, LASR was recognized to vary linearly with r and LA volume with r3 . Expanding this cubic relation as a Taylor series resulted in a simple linear equation: LAESV/LAEDV = 1 + 3 × LASR . To validate this, 52 transthoracic echocardiograms were analyzed from 18 patients who underwent transcatheter edge-to-edge repair (TEER) with MitraClip with serial assessment pre-procedure, 1 month post-clip, and 12 months post-TEER. Linear regression was performed to compare the geometric equation to a statistical model created by a line of best fit to relate LAESV/LAEDV to LASR . RESULTS: The statistical and geometric model both resulted in a strong correlation (r = .8, p < .001, respectively). The slope of the line in the statistical model was 3.3, which was statistically indistinguishable from the expected slope of 3 based on the geometric model (Figure 2A). Using the geometric model to compare the measured versus calculated LAESV/LAEDV also resulted in a strong correlation (r = .8, p < .001)(Figure 2B). CONCLUSION: We describe the relationship between LA volume and strain mathematically by considering the geometry of the LA. This model enhances our understanding of the interaction between atrial strain and volume. Further research is necessary to validate this using 3D atrial volumes in a broader cohort of subjects.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Átrios do Coração/diagnóstico por imagem , Ecocardiografia/métodos , Modelos Teóricos
3.
Echocardiography ; 38(11): 1932-1940, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34747056

RESUMO

BACKGROUND: Pulmonary thromboendarterectomy (PTE) is a curative procedure for chronic thromboembolic pulmonary hypertension (CTEPH). Right ventricular free wall strain (RV FWS) and right atrial strain (RAS) are not well studied in a CTEPH population. We sought to determine temporal trends in RAS and RV FWS in patients post-PTE. METHODS: 28 patients undergoing PTE for CTEPH were prospectively enrolled in a surgical database. Comprehensive echocardiographic assessment of the right heart was performed including RV FWS, right atrial volume, and the three components of RAS: reservoir, conduit, and booster strain. RESULTS: Patients undergoing PTE demonstrated improvement in NYHA functional class (P < 0.001). Hemodynamic assessment showed improvement in mean pulmonary artery pressure from 49.7 ± 8.5 mm Hg to 23.9 ± 6.5 mm Hg (P < 0.001) and pulmonary vascular resistance decreased from 7.8 ± 3.2 wu to 2.4 ± 1.3 wu (P < 0.001). Tricuspid annular plane systolic excursion (TAPSE) and lateral S` declined immediately post-op. RV FWS improved from -14.4 ± 4% to -19 ± 3.4% post-op and -21.2 ± 4.7% at long-term follow-up (P < 0.001). Improvement in RV FWS post-op was driven primarily by increases in the apical and mid segments. RA volume declined significantly during the study period. RA reservoir and conduit strain improved after PTE. CONCLUSION: Patients undergoing PTE for CTEPH had significant improvement in right heart hemodynamics immediately post-op. Traditional echo metrics of RV performance including TAPSE and lateral S` did not improve. RV FWS improved, which was driven by changes in the apical and mid segments. This highlights that RV FWS is a viable and useful metric to follow in CTEPH patients post-PTE.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Disfunção Ventricular Direita , Endarterectomia , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/cirurgia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/cirurgia , Resistência Vascular , Função Ventricular Direita
4.
Echocardiography ; 37(5): 758-768, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32315483

RESUMO

Tricuspid valve pathology is increasingly recognized as an important contributor to patient morbidity. Accordingly, interest in transcatheter interventions for tricuspid valve disease has continued to grow. Echocardiographic imaging of the tricuspid valve has therefore become an integral component of patient assessment and the essential imaging modality for interventional procedures. The need for improved tricuspid valve imaging has highlighted the variability in tricuspid valve anatomy and the difficulties of using two-dimensional (2D) echocardiography alone to determine the location and type of tricuspid valve disease. Here, three-dimensional (3D) imaging using tools such as biplane imaging, multiplanar reconstruction and live 3D acquisition allow a more accurate and efficient evaluation of the tricuspid valve. The 3D imaging of the tricuspid valve is often focused on transesophageal echocardiography, but the more anterior location of the tricuspid valve also lends itself to assessment with transthoracic echocardiography. In this review, we will examine how 3D imaging can complement and enhance the information obtained from 2D echocardiography, and present novel applications for the quantitation of valvular disease and its utility in intraprocedural imaging.


Assuntos
Ecocardiografia Tridimensional , Doenças das Valvas Cardíacas , Insuficiência da Valva Tricúspide , Ecocardiografia Transesofagiana , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem
5.
Echocardiography ; 37(6): 913-916, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32472553

RESUMO

Tricuspid valve (TV) degeneration after surgical repair with an annuloplasty ring is problematic as redo operation carries high mortality. This can be addressed with transcatheter therapies to implant a valve within in prior ring (tricuspid valve-in-ring). When an incomplete ring is present, paravalvular leak is commonly encountered after tricuspid valve-in-ring (TViR) implant; however, this can be addressed with paravalvular leak closure devices. Multimodality imaging including cardiac computed tomography and three-dimensional (3D) transesophageal echocardiography (TEE) are important for successful TViR implant. We report a case of tricuspid regurgitation after tricuspid repair with an incomplete annuloplasty ring and subsequent paravalvular leak closure.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
7.
JACC Case Rep ; 2(8): 1129-1134, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34317432

RESUMO

Transcatheter mitral valve-in-valve replacement (TMVR) offers a less invasive strategy for managing bioprosthetic mitral valve dysfunction. TMVR positioning is challenging in the setting of a radiolucent bioprosthetic sewing ring. We present 2 cases demonstrating the roles of fluoroscopy and echocardiography in guiding TMVR placement within bioprostheses with radiolucent sewing rings. (Level of Difficulty: Intermediate.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA