Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Nanosci Nanotechnol ; 14(7): 4960-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24757967

RESUMO

Few layer graphene oxide (GO) nanosheets were prepared by a very fast modified Hummers method and widely characterized. Avoiding further chemical reactions, trying to take advantage of the easy exfoliation of GO favoring the formation of a tribofilm, and using a methodology well known to the lubricant industry, they were added to a mineral oil by the help of a dispersant. The tribological behaviour of GO in mineral oil was investigated under a wide spectrum of conditions, from boundary and mixed lubrication to elastohydrodynamic regimes. A ball on disc setup tribometer has been used to verify the friction reduction due to nanosheets dispersed in mineral oil. Their good friction and anti-wear properties may possibly be attributed to the small and extremely thin laminated structure, which offer lower shear stress and prevent interaction between metal interfaces. Furthermore, the results clearly prove that graphene platelets in oil easily form a protective film to prevent the direct contact between steel surfaces and, thereby, improving the frictional behaviour of the base oil. This evidence is also related to the frictional coefficient trend in boundary regime.

2.
J Oral Implantol ; 40(4): 438-47, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25106008

RESUMO

Primary stability is an indicator of subsequent osseointegration of dental implants. However, few studies have compared the implant stability among anatomical regions and bone types; thus, not enough data exist regarding the stability of implants placed in regenerated bone (RB). The present study evaluated primary and long-term stability of implants placed in RB and non-regenerated healed bone (HB). A total of 216 screw cylinder implants were placed in 216 patients (98 in HB and 118 in RB, 6 [RB6, N = 68] or 12 [RB12, N = 50] months after tooth extraction). Implant stability was evaluated using resonance frequency analysis (RFA) measured at the time of implant placement (E1), at the time of loading (4 months after placement, E2), and 4 months after loading (E3). Various clinically relevant measurements were obtained, such as implant diameter, length, and location, as well as bone quality. At E1, implant location, bone quality, and experimental group significantly affected implant stability (all at P < .05). At E2, implant location, diameter, length, and experimental group significantly affected implant stability (all at P < .05). At E3, bone quality, implant diameter, length, and experimental group significantly affected implant stability (all at P < .01). Stability for the RB12 group was significantly higher than all other corresponding values; further, the values did not change significantly over time. For the HB and RB6 groups, stability was significantly higher at E2 than at E1 (P < .001) and was no different between E2 and E3. Implant location, length, and experimental group were associated with these differences (all at P < .05). Compared with HB and RB6, higher implant stability may be achieved in regenerated bone 12 months post-extraction (RB12). This stability was achieved at E1 and maintained for at least 8 months. Variables such as implant length, diameter, and bone quality affected the stability differently over time. Implant stability varied in different anatomic regions and with regard to different healing processes in the bone.


Assuntos
Implantes Dentários para Um Único Dente , Osseointegração/fisiologia , Alvéolo Dental/cirurgia , Densidade Óssea/fisiologia , Regeneração Óssea/fisiologia , Periodontite Crônica/cirurgia , Curetagem/métodos , Desbridamento/métodos , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Mandíbula/cirurgia , Maxila/cirurgia , Membranas Artificiais , Pessoa de Meia-Idade , Estudos Prospectivos , Vibração , Cicatrização/fisiologia
3.
Nanotechnology ; 24(12): 125601, 2013 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-23459162

RESUMO

Hybrid organic-inorganic oleylamine@MoS2-CNT nanocomposites with different compositions were obtained by thermal decomposition of tetrathiomolybdate in the presence of oleylamine and high quality multiwalled carbon nanotubes (CNTs) previously prepared by the CCVD technique. The nanocomposite samples were characterized by the TEM, SEM TG-MS, Raman and XRD techniques and successfully tested as anti-friction and anti-wear additives for grease lubricants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA