Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Braz Oral Res ; 38: e062, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39016368

RESUMO

This study investigated the impact of 'storage condition' and 'period of storage' on selected physico-mechanical properties and fracture reliability of a resin-based composite (RBC). Specimens, prepared from a nanofilled RBC (Filtek Z350 XT; 3M ESPE), underwent tests for degree of conversion (DC), flexural strength (σ), flexural modulus (E), and hardness. The specimens were initially grouped into dry storage at 37°C or wet storage in distilled water at 37°C. Subsequently, they were further divided into four subgroups based on the period of storage: 6, 24, 72, or 168 hours. Specimens tested immediately after preparation served as control. Data analysis employed two-way ANOVA and Weibull analysis (α = 5%). Compared to the control, an increase in DC was observed only after 72 hours of dry storage; σ showed higher values after both dry and wet storage, regardless of the storage period (except for the group wet-stored for 168 hours); E increased with dry storage for at least 24 hours or wet storage for 72 hours; and hardness increased after dry storage for at least 24 hours or wet storage for up to 72 hours. The Weibull modulus remained unchanged under any of the distinct storage conditions. Dry storage resulted in greater characteristic strength than the control, whereas wet storage contributed to higher strength values only at shorter periods (up to 24 hours). Overall, the inherent properties of RBCs with a similar composition to that tested in this study may change with varying storage conditions and periods.


Assuntos
Resinas Compostas , Resistência à Flexão , Testes de Dureza , Dureza , Teste de Materiais , Resinas Compostas/química , Fatores de Tempo , Análise de Variância , Reprodutibilidade dos Testes , Valores de Referência , Propriedades de Superfície , Temperatura
2.
Aust Endod J ; 50(2): 409-463, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38923176

RESUMO

Numerous systematic reviews (SRs) have produced conflicting findings on engine-driven nickel-titanium reciprocating instruments (reciprocating instruments) since Yared's seminal study 15 years ago. This umbrella review analysed SRs examining the clinical and laboratory evidence regarding reciprocating instruments for root canal treatment. SRs that evaluated qualitatively and/or quantitatively the outcomes postoperative pain, oral health-related quality of life (OHRQoL), shaping ability, debris extrusion, microbial load, endotoxins reduction, cyclic fatigue, file fracture, dentinal cracks and root canal filling removal were included. The AMSTAR 2 tool was used to evaluate SRs quality, while the ROBIS tool to assess risk of bias (RoB). Forty SRs were included. The SRs revealed predominantly 'high' RoB and 'critically low' quality. Most focused on technical outcomes, exhibiting significant methodological and statistical heterogeneity. Findings suggest comparable efficacy between reciprocating and rotary instruments. However, due to the scarcity of high-quality evidence, future well-designed studies and reviews considering core outcome measures are needed.


Assuntos
Níquel , Preparo de Canal Radicular , Titânio , Humanos , Preparo de Canal Radicular/instrumentação , Desenho de Equipamento , Instrumentos Odontológicos
3.
J Funct Biomater ; 15(6)2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38921537

RESUMO

In this study, we investigate the antibacterial effect of silver atoms implanted into a thin surface layer of titanium at low energies using an alternative ion plating technology called Diversified Ion Plating. Silver atoms were incorporated into titanium samples using reactive low-voltage ion plating at 2 keV and 4 keV. Surface modifications and morphology were evaluated using wettability, profilometry measurements, and energy-dispersive spectroscopy. For a precise determination of the quantity and depth of implanted silver atoms on titanium surfaces, a combination of experimental techniques such as Rutherford Backscattering Spectrometry along with Monte Carlo simulations were utilized. To assess the antibacterial effects of the silver atoms incorporated into pure titanium surfaces, bacterial suspension immersion tests were performed with a standard strain of Staphylococcus aureus (ATCC 12600). The outcomes indicate that titanium surfaces implanted with silver atoms were more effective in inhibiting the growth of Staphylococcus aureus than pure titanium surfaces. Better results were found when the deposition was performed at 4 keV, indicating that a deeper implantation of silver, spanning a few nanometers, can result in a longer and more effective release of silver atoms. These findings suggest the potential for the development of new, cost-effective biomaterials, paving the way for improved implant materials in various health-related applications.

4.
J Funct Biomater ; 15(3)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38535263

RESUMO

This study aimed to evaluate the antimicrobial properties, cell viability, and matrix metalloproteinase (MMP) inhibition capacity of several endodontic materials aimed at vital pulp therapy: Pro Root MTA®, EndoSequence®, Biodentine®, MTA Angelus®, TheraCal LC®, and BioC Repair®. The materials were prepared according to the manufacturer's instructions. Antimicrobial tests were conducted using a microcosm biofilm model, cell viability was assessed using murine fibroblasts (L929), and MMP activity was analyzed through electrophoresis. The results showed that BioC Repair®, Biodentine®, and EndoSequence® exhibited similar antimicrobial properties, while MTA Angelus® and ProRoot MTA® had inferior results but were comparable to each other. In terms of cell viability, no significant differences were observed among the materials. EndoSequence® demonstrated the highest MMP inhibition capacity. In conclusion, BioC Repair®, Biodentine®, EndoSequence®, and TheraCal® showed better antimicrobial properties among the tested materials. The materials did not exhibit significant differences in terms of cytotoxicity. However, EndoSequence® displayed superior MMP inhibition capacity.

5.
Syst Rev ; 12(1): 236, 2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-38098125

RESUMO

The global healthcare crisis with the COVID-19 pandemic has placed a significant overwhelming demand for intubation procedures and the need for reliable and accessible video laryngoscopes. The purpose of this scoping and technological review is to provide a comprehensive overview of the current state of the art, covering the period from 2007 to 2022, pertaining to the manufacturing process, characteristics, and validation of video laryngoscopes produced using additive manufacturing techniques. Following the guidelines outlined in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR), an exhaustive search was conducted across nine prominent databases (PubMed, Web of Science, Scopus, Cochrane, Prospero, Scielo, Embase, Lilacs, Virtual Health Libraries-VHL) and four patent databases (EPO/ESPACENET, WIPO/PATENTSCOPE, National Institute of Industrial Property (INPI), Google Patents). The main materials utilized for the impression, as well as the physical characteristics of the device are introduced at first. Crucial aspects to facilitate proper visualization of the anatomical structures during endotracheal intubation as the optimal angulation of the blade, the mechanical resistance of the device, traction force on the jaw, intubation time, and the experimental methods employed to validate its performance were reviewed in terms of their recent advances.


Assuntos
Laringoscópios , Humanos , Pandemias , Intubação Intratraqueal/métodos , Gravação em Vídeo
7.
Braz. oral res. (Online) ; 38: e062, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1564197

RESUMO

Abstract This study investigated the impact of 'storage condition' and 'period of storage' on selected physico-mechanical properties and fracture reliability of a resin-based composite (RBC). Specimens, prepared from a nanofilled RBC (Filtek Z350 XT; 3M ESPE), underwent tests for degree of conversion (DC), flexural strength (σ), flexural modulus (E), and hardness. The specimens were initially grouped into dry storage at 37°C or wet storage in distilled water at 37°C. Subsequently, they were further divided into four subgroups based on the period of storage: 6, 24, 72, or 168 hours. Specimens tested immediately after preparation served as control. Data analysis employed two-way ANOVA and Weibull analysis (α = 5%). Compared to the control, an increase in DC was observed only after 72 hours of dry storage; σ showed higher values after both dry and wet storage, regardless of the storage period (except for the group wet-stored for 168 hours); E increased with dry storage for at least 24 hours or wet storage for 72 hours; and hardness increased after dry storage for at least 24 hours or wet storage for up to 72 hours. The Weibull modulus remained unchanged under any of the distinct storage conditions. Dry storage resulted in greater characteristic strength than the control, whereas wet storage contributed to higher strength values only at shorter periods (up to 24 hours). Overall, the inherent properties of RBCs with a similar composition to that tested in this study may change with varying storage conditions and periods.

8.
Braz. oral res. (Online) ; 36(Jun): e082, 2022.
Artigo em Inglês | LILACS, BNUY-Odon, BNUY | ID: biblio-1372593

RESUMO

Abstract The objective of the present study was to evaluate the effect of irradiance and radiant exposure on the chemical-mechanical properties of a resin composite. A micro-hybrid resin composite (Clearfil AP-X, Kuraray) was investigated under two different irradiances: low (300 mW/cm2) and high (800 mW/cm2) and radiant exposures: 8 and 16 J/cm2. Four groups, named Low 8 J/cm2, High 8 J/cm2, Low 16 J/cm2, and High 16 J/cm2 were tested, and their flexural strengths, elastic moduli, depths of cure, and degrees of conversion were evaluated. Data were analyzed using two-way ANOVA and Tukey's test. A multiple linear regression model was used to correlate the irradiance and radiant exposure with dependent variables (α = 0.05). Irradiance and radiant exposure were found statistically significant for all dependent variables. The interaction between the factors was statistically significant only for the degree of conversion and elastic modulus. Group Low 16 J/cm2 exhibited a significantly superior performance in all the evaluated properties. Barring the degree of conversion, no significant differences were observed among the properties evaluated between the Low 8 J/cm2 and High 8 J/cm2 groups. The adjusted R2 values were high for the depth of cure and degree of conversion (0.58 and 0.96, respectively). Both irradiance and radiant exposure parameters play an important role in establishing the final properties of a micro-hybrid resin composite. Irradiance has a greater influence under higher radiant exposures.


Assuntos
Teste de Materiais , Resinas Compostas , Materiais Dentários , Lâmpadas de Polimerização Dentária , Polimerização , Resistência à Flexão , Propriedades de Superfície
9.
Braz. oral res. (Online) ; 36: e091, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1384209

RESUMO

Abstract The objective of this study was to formulate an experimental light-cured periodontal dressing containing alpha-humulene and to compare its physical, antimicrobial, and cytotoxicity properties with commercial gold standards (Barricaid® and Periobond®). Two periodontal dressing formulations were developed (a and b). The formulations were divided into 5 groups according to the alpha-humulene concentration as follows: Ea - control group, Ea1 - 1%, Ea5 - 5%, Ea10 - 10%, and Ea20 - 20%; Eb - control group, Eb1 - 1%, Eb5 - 5%, Eb10 - 10%, and Eb20 - 20%. Materials characterization was performed using the degree of conversion, cohesive strength, sorption, and solubility assays. Antimicrobial assay was performed using the modified direct contact test against E. faecalis and S. aureus. Cytotoxicity was assessed by the cell viability experiment using L929 fibroblasts. In general, the cohesive strength values of materials decreased as the alpha-humulene concentration increased. All the experimental dressings showed antimicrobial activity against both bacteria tested. Cell viability results for the Ea, Ea1, Eb, and Eb1 groups showed moderate cytotoxic effect. The formulations containing alpha-humulene showed similar behavior to the commercial references. Thus, formulations containing alpha-humulene have potential to be used as periodontal dressing.

10.
Braz. oral res. (Online) ; 36: e037, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - odontologia (Brasil) | ID: biblio-1364588

RESUMO

Abstract: This paper evaluates the physicochemical and biological properties of experimental resin-based dual-cured calcium aluminate (CA) and calcium titanate (CTi) materials for vital pulp therapy (VPT). The experimental dual-cured materials were obtained as two pastes: a) Bis-EMA 10, PEG 400, DHEPT, EDAB, camphorquinone, and butylated hydroxytoluene; and b) fluoride ytterbium, Bis-EMA 10, Bis-EMA 30, benzoyl peroxide, and butylated hydroxytoluene. The materials were divided into six groups based on the added calcium component: MTA (MTA®, Angelus); CLQ (Clinker-Fillapex®, Angelus); CA (calcined at ,1200°C in pastes a and b); CA800 (calcined at 800°C in paste a); CA1200 (calcined at 1,200°C in paste a); and CTi (paste a). The real-time degree of conversion and rate of polymerization (n = 3), diametral tensile strength (n = 10), hydrogen potential (n = 15), calcium ion release (n = 10), water sorption and solubility (n = 10), and cell viability (n = 6) were evaluated. One- and two-way ANOVA and Tukey's post hoc test were used in the analysis of the parametric data, and Kruskal-Wallis and Dunn's multiple tests were used to analyze the nonparametric data (α = 0.05). CLQ, CA800 and CA1200 had the highest diametral tensile strength. The water solubility of MTA was similar to that of CA800, CA1200 and CTi. CA800 and CA1200 resulted in cell viabilities similar to those of MTA and CLQ. The experimental dual-cured CA-based material that calcined at 800°C showed physicochemical and biological properties suitable for VPT, and similar to those of MTA.

11.
Braz. oral res. (Online) ; 35: e045, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1153603

RESUMO

Abstract The objective of this study was to evaluate the biocompatibility and mechanical properties of two commercially available and one experimental periodontal dressing materials. The cytotoxicity of Periobond ® , Barricaid ® and one experimental periodontal dressing based on Exothane ® 8 monomer was tested on 3T3/NIH mouse fibroblast. Genotoxicity was assessed by micronuclei formation, and cell alterations were analyzed using light microscopy. Both biological assays were performed using the eluate obtained from specimens after 24, 72, or 168 hours of incubation. Mechanical characterization was assessed through the ultimate tensile strength and the water sorption and solubility tests. The significance level of α = 0.05 was used for all statistical analyses. All the materials promoted a cell viability lower than 60% in all evaluated times. In general, the cell viability was significantly reduced after 72 and 168h of specimens' incubation. Considering the factor material, there were not statistical differences in the cell viability (p = 0.156). The genotoxicity was not statistically significant among the groups in the different periods of time (p > 0.05). Differences in the ultimate tensile strength values were not statistically significant different among the groups (p = 0.125). Periobond ® showed the higher water sorption values (p < 0.001). Regarding solubility, there were no statistical differences between the groups (p = 0.098). All the periodontal dressing materials evaluated in this study exerted a cytotoxic effect against mouse fibroblasts, and their toxicity became more evident over time. Among the materials evaluated, the experimental light-cure type has shown overall similar properties to the commercial references.


Assuntos
Animais , Camundongos , Curativos Periodontais , Bandagens , Solubilidade , Resistência à Tração , Teste de Materiais
12.
Braz. arch. biol. technol ; 64: e21200344, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1350250

RESUMO

Abstract This study developed and characterized a method for controlled deposition of thin films of hydroxyapatite on titanium surfaces. Thirty-three titanium cylinders were randomly divided: negative control/polished (A), acid etched (B) and coated by hydroxyapatite (C). Acid etch was performed in an aqueous solution of nitric acid. The cylinders were subjected to coating by a thin film of hydroxyapatite with dip-coating method. These cylinders were submitted to a pre-heat treatment 450°C/10 minutes and 800°C/2 hours. Scanning electron microscopy analysis demonstrated a homogeneous and smooth surface (A), an irregular and porous surface (B) and a crystalline deposition (C). The X-ray energy dispersive analysis showed characteristic elements of hydroxyapatite (C). Analysis by X-ray diffraction showed the presence of characteristic peaks of hydroxyapatite, corresponding to the structural composition of hydroxyapatite. Cell viability (MTT-assay in NIH-3T3-Cells) test demonstrated no differences between the groups. Titanium surfaces coated with a hydroxyapatite film by the dip-coating method suggest adequate control of deposition of thin films of hydroxyapatite and similar cell viability using mouse fibroblasts.

13.
RFO UPF ; 25(3): 410-419, 20201231. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-1357824

RESUMO

Objetivo: avaliar as propriedades físicas e biológicas dos cimentos de ionômero de vidro convencionais (CIVs). Metodologia: foram avaliados os seguintes CIVs: Fuji IX (GC Europe, Bélgica), Ketac Molar (3M ESPE, Estados Unidos), Maxxion R (FGM, Brasil) e Vitro Molar (Nova DFL, Brasil). O tempo de presa, a alteração dimensional, a radiopacidade, a sorção e a solubilidade em água foram avaliados para todos os materiais. A resistência à compressão foi analisada em intervalos de 1h, 24h, 7 dias e 28 dias; e liberação de íons fluoreto em 3h, 24h e 72h. A viabilidade celular foi avaliada após 24 e 48 horas com células de fibroblastos. A análise estatística foi realizada por meio do software SigmaPlot 12 (Systat Inc, San Jose, CA, EUA), com nível de significância estabelecido em α = 0,05. Resultado: apenas o Fuji IX teve um tempo de presa dentro da faixa recomendada pela Especificação Padrão da ADA 96 (2012), não superior a 6 minutos. Vitro Molar e Maxxion R apresentaram radiopacidade que não estava de acordo com a especificação ADA 96 (2012). Maxxion R e Vitro Molar mostraram uma alteração dimensional estatisticamente semelhante. Quanto às propriedades mecânicas, o Fuji IX foi o único CIV que apresentou aumento da resistência à compressão durante o período de avaliação de 28 dias. O Ketac Molar apresentou a maior viabilidade celular, enquanto o Maxxion R apresentou citotoxicidade severa e o maior valor cumulativo de liberação de flúor. Conclusão: Fuji IX e Ketac Molar apresentaram as propriedades físicas e biológicas mais adequadas entre os CIVs avaliados.(AU)


Objective: to evaluate the physical and biological properties of conventional glass ionomer cements (GICs). Methodology: the following GICs were evaluated: Fuji IX (GC Europe, Belgium), Ketac Molar (3M ESPE, United States), Maxxion R (FGM, Brazil) and Vitro Molar (Nova DFL, Brazil). Setting time, dimensional change, radiopacity, water solubility and water absorption were evaluated for all materials. Compressive strength was analyzed after intervals of 1h, 24h, 7 days and 28 days; and release of fluoride ions at 3 am, 24 am and 72 am. Cell viability was assessed after 24 and 48 hours with fibroblast cells. Statistical analysis was performed using SigmaPlot 12 software (Systat Inc, San Jose, CA, USA), with a significance level set at α = 0.05. Result: only the Fuji IX had an adjustment time within the range recommended by the Standard Specification of ADA 96 (2012) of not exceeding 6 minutes. Vitro Molar and Maxxion R had radiopacity that was not in accordance with the ADA 96 (2012) specification. Maxxion R and Vitro Molar showed a statistically similar dimensional change. As for mechanical properties, Fuji IX was the only GIC that showed an increase in compressive strength during the evaluation period of 28 days. Ketac Molar showed the highest cell viability, while Maxxion R showed severe cytotoxicity and the highest cumulative fluoride release value. Conclusion: Fuji IX and Ketac Molar showed the most appropriate physical and biological properties among the evaluated GICs.(AU)


Assuntos
Animais , Camundongos , Cimentos de Ionômeros de Vidro/química , Solubilidade , Fatores de Tempo , Teste de Materiais , Sobrevivência Celular , Análise de Variância , Força Compressiva , Fibroblastos , Fluoretos/química
14.
Braz. oral res. (Online) ; 32: e15, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889485

RESUMO

Abstract This study evaluated the shear bond strength (SBS) of self-adhesive resin cements (SARCs) to dentin and their physical-chemical properties. Five commercial SARCs were evaluated [SmartCem®2 - DENTSPLY (SC2); BisCem® - Bisco (BC); SeT PP® − SDI (SeT); Relyx U100® - 3M ESPE (U100) and YCEM® SA - Yller (YCEM)]. The SARCs were evaluated for SBS to dentin (n = 10) after 24 h, 6 months, and 12 months. The dentin demineralization caused by acidic monomers was observed by SEM, and pH-neutralization of eluate was observed for 24 h. Degree of conversion (DC), rate of polymerization (Rp), flexural strength (FS), and elastic modulus (E) were evaluated. Immediate SBS of SC2, SET, U100, and YCEM were statistically higher than that of BC (p < 0.001). After 12 months, all SARCs showed reduced SBS values and U100 showed values similar to those of SET and YCEM, and higher than those of BC and SC2 (p = 0.001). Demineralization pattern of SARCs was similar. At 24h, all SARCs showed no differences in the pH-value, except BC and U100 (p < 0.001). YCEM showed the highest Rp. U100, YCEM, and SC2 showed statistically higher FS (p<0.001) and E (p < 0.001) when compared with SET and BC. U100 and YCEM showed the best long-term bonding irrespective of the storage period. A significant reduction in SBS was found for all groups after 12 months. SBS was not shown to be correlated with physical-chemical properties, and appeared to be material-dependent. The polymerization profile suggested that an increased time of light activation, longer than that recommended by manufacturers, would be necessary to optimize DC of SARCs.


Assuntos
Resinas Compostas/química , Cimentos de Resina/química , Dentina/efeitos dos fármacos , Cura Luminosa de Adesivos Dentários/métodos , Valores de Referência , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Maleabilidade , Resistência ao Cisalhamento , Dentina/química , Transição de Fase/efeitos dos fármacos , Módulo de Elasticidade , Polimerização
15.
J. appl. oral sci ; 26: e20170562, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-954492

RESUMO

Abstract The objective of this study was to compare selective physical-mechanical properties, antibacterial effects and cytotoxicity of seven temporary restorative materials (TRM): five resin-based materials [Bioplic (B), Fill Magic Tempo (FM), Fermit inlay (F), Luxatemp LC (L) and Revotek LC (R)], and zinc oxide-eugenol cement (IRM) and glass ionomer cement (GIC) as the controls. Material and methods The physical-mechanical properties were evaluated by determining microleakage (ML), ultimate tensile strength (UTS) and Shore D hardness (SDH). In addition, the polymerization rate (Pr-1), depth of cure (DC), water sorption and solubility (WS/SL) were evaluated. The antimicrobial effects of the materials were assessed by biofilm accumulation of Streptococcus mutans (BT) and the direct contact test (DCT) by exposure to Enterococcus faecalis for 1 and 24 h, and cytotoxicity by MTT assay. The data were analyzed by ANOVA or Kruskall-Wallis tests, and a complementary post-hoc method (p<0.05). Results Group B, followed by FM and GIC had significantly lower percentages of microleakage in comparison with the other groups; Groups FM and L showed the highest WS, while Groups R and FM showed the significantly lowest SL values (p<0.05). Group R showed the statistically highest UTS mean and the lowest DC mean among all groups. Group F showed the lowest S. mutans biofilm accumulation (p=0.023). Only the Group L showed continued effect against E. faecalis after 1 h and 24 h in DCT. The L showed statistically lower viability cell when compared to the other groups. Conclusions These findings suggest the antibacterial effect of the temporary materials Fill Magic and Bioplic against S. mutans, while Luxatemp showed in vitro inhibition of S. mutans biofilm accumulation and E. faecalis growth. Regarding the cell viability test, Luxatemp was the most cytotoxic and Fill Magic was shown to be the least cytotoxic.


Assuntos
Animais , Bovinos , Camundongos , Streptococcus mutans/efeitos dos fármacos , Enterococcus faecalis/efeitos dos fármacos , Resinas Compostas/farmacologia , Resinas Compostas/química , Fibroblastos/efeitos dos fármacos , Antibacterianos/sangue , Antibacterianos/farmacologia , Ácidos Polimetacrílicos/farmacologia , Ácidos Polimetacrílicos/química , Materiais Restauradores do Canal Radicular/farmacologia , Materiais Restauradores do Canal Radicular/química , Solubilidade , Resistência à Tração , Fatores de Tempo , Cimento de Óxido de Zinco e Eugenol/farmacologia , Cimento de Óxido de Zinco e Eugenol/química , Teste de Materiais , Sobrevivência Celular/efeitos dos fármacos , Reprodutibilidade dos Testes , Bis-Fenol A-Glicidil Metacrilato/farmacologia , Bis-Fenol A-Glicidil Metacrilato/química , Restauração Dentária Temporária/métodos , Cimentos de Ionômeros de Vidro/farmacologia , Cimentos de Ionômeros de Vidro/química , Testes de Dureza , Metilmetacrilatos/farmacologia , Metilmetacrilatos/química
16.
Braz. j. oral sci ; 17: e181357, 2018. ilus
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-970423

RESUMO

Aim: The aim of this study was to evaluate a new method for measuring the retention values of different denture adhesives. Methods: The adhesive strength values of three different commercial denture adhesives (Corega powder, Corega adhesive tape and Ultra Corega cream) were evaluated using three different moisturizing agents (distilled water, artificial saliva and natural saliva). The adhesive test was performed on a universal testing machine, after applying the adhesive products to acrylic resin specimens, under two different test conditions (wetting or dipping). Tensile bond strength values in MPa were obtained for each denture adhesive presentation and test condition. Viscosity of the denture adhesives mixed with the different moisturizing agents was determined using a rotary rheometer. Maximum viscosity values were analyzed using the one-way ANOVA test. Tensile bond strength data was analyzed using Kruskal-Wallis and the Tukey's test. Pooled data of each denture adhesive presentations for all test conditions was also carried out. Correlation between viscosity and pooled tensile strength values was analyzed through linear regression analysis. A significance level of α=0.05 was set for all analyses. Results: Results showed that statistically higher adhesion strength was obtained with tape and cream adhesives when using natural saliva as moisturizing agents (p<0.05). The adhesive strength values obtained with the dipping method were similar to those obtained with the conventional wetting method. The denture retention strength was influenced by both the denture adhesive type and moisturizing agent used. Conclusion: The dipping method showed to be a reliable test capable to simulate the oral conditions and should be better explored in further studies


Assuntos
Resistência à Tração , Retenção de Dentadura , Bases de Dentadura
17.
Braz. oral res. (Online) ; 32: e104, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974458

RESUMO

Abstract This study evaluated the three-year lifespan of the bond to dentin of experimental self-etch adhesives containing benzodioxole derivatives - 1,3-benzodioxole (BDO) and piperonyl alcohol (PA) - as co-initiator alternative to amines. Adhesive resins were formulated using Bis-GMA, TEGDMA, HEMA, camphorquinone and different co-initiators: BDO, PA or ethyl 4-dimethylamino benzoate (EDAB - amine). An experimental self-etch primer was used to complete the two-step, self-etch adhesive system. Clearfil SE Bond (CSE) was used as commercial reference. Bond strength to human dentin was assessed by microtensile bond strength (µTBS) test, and failure mode was classified. Morphology of the dentin bonding interface was assessed via scanning electron microscopy (SEM). Irrespective of the dental adhesives evaluated, µTBS was higher after 24 hours compared with that after 1.5 and 3 years (p ≤ 0.001). However, adhesives with BDO and PA as co-initiators showed significantly higher bond strength than the bonding resin with EDAB (p ≤ 0.002), independent of the time evaluated. The commercial adhesive CSE showed similar bond strength compared with the other groups (p ≥ 0.05). Mixed failures were mainly observed after 24 hours, while adhesive failures were more frequently observed after 1.5 and 3 years. No notable differences in homogeneity and continuity along the bonded interfaces were detected among the materials in the SEM analysis. In conclusion, benzodioxole derivatives are feasible alternative co-initiators to tertiary amine in camphorquinone-based self-etching dental adhesive formulations.


Assuntos
Humanos , Álcoois Benzílicos/química , Adesivos Dentinários/química , Cimentos de Resina/química , Dentina/efeitos dos fármacos , Dioxóis/química , Benzodioxóis/química , para-Aminobenzoatos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Teste de Materiais , Cânfora/análogos & derivados , Cânfora/química , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Dentina/química , Metacrilatos/química
18.
Braz. dent. j ; 29(1): 48-53, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888727

RESUMO

Abstract The aim of this study was to synthesize and evaluate physicochemical properties of a new salicylate derivative in experimental calcium-based root canal sealers. Two salicylate derivatives were synthesized for the transesterification reaction of methyl salicylate with two different alcohols (1,3-butylenoglicol disalicylate-BD and pentaerythritol tetrasalicylate -PT) in molar ratio 1:3 and 1:6, respectively. The products (BD and PT), were characterized by Fourier Transform Infrared Spectroscopy (FTIR) and Nuclear Magnetic Resonance spectroscopy (RMN). Calcium-based experimental sealers were prepared with the same catalyst paste (60% of MTA, 39% of n-ethyl-o-toluenesulfonamide, and 1% titanium dioxide) and four different concentrations of BD and PT in the base pastes (40/0 - control, 35/5, 30/10 and 20/20) with 60% of bismuth oxide. The experimental sealers were evaluated for setting time, solubility (24 h, 7, 14 and 30 days), diametral tensile strength and Young's Modulus. Data were analyzed by one- or two-way ANOVA with Tukey's test (p<0.05). The addition of PT reduced the materials setting time. After 24 h the sealer 40/0 and 35/5 had higher solubility, and after 14 and 28 days the sealer 20/20 showed the lowest solubility (p<0.05). After 7 days the sealer 20/20 stabilized its solubility. The sealer 40/0 presented the highest values and the 20/20 presented the lowest values of diametral tensile strength and Young's modulus (p<0.05). The addition of PT to calcium-based root canal sealers provides benefits to the setting time and solubility.


Resumo O objetivo neste estudo foi sintetizar e avaliar as propriedades físico-químicas de um novo derivado do salicilato em cimentos endodônticos experimentais à base de cálcio. Dois derivados de salicilato foram sintetizados por meio de uma reação de trans esterificação do salicilato de metila com dois diferentes alcoóis (1,3-butilenoglicol dissalicilato-BD e pentaeritritol tetrassalicilato-PT) na proporção molar de 1: 3 e 1:6, respectivamente. Os produtos (BD e PT), foram caracterizados por espectroscopia infravermelho transformada de Fourier (FTIR) e espectroscopia de ressonância magnética nuclear (RMN). Os cimentos experimentais à base de cálcio foram preparados com a mesma pasta catalisadora (60% de MTA, 39% de N-etil o/p toluenosulfonamida e 1% de dióxido de titânio) e quatro concentrações diferentes de BD e PT nas pastas base (40/0 - controle, 35/5, 30/10 e 20/20) com 60% de óxido de bismuto. Os cimentos foram avaliados quanto ao tempo de endurecimento, à solubilidade (24 h, 7, 14 e 28 dias), resistência à tração diametral e ao módulo de elasticidade. Os dados foram analisados por ANOVA um ou dois fatores e as médias comparadas pelo teste de Tukey (p<0,05). A adição de PT reduziu o tempo de endurecimento dos materiais testados. Após 24 horas os cimentos 40/0 e 35/5 apresentaram maior solubilidade que os demais e após 14 e 28 dias o cimento 20/20 foi o que apresentou menor solubilidade (p<0,05). Após 7 dias o grupo 20/20 estabilizou a sua solubilidade. O cimento 40/0 apresentou os maiores valores e o cimento 20/20 apresentou os menores valores de resistência à tração diametral e módulo de elasticidade (p<0,05). A adição de PT a cimentos à base de cálcio possibilita benefícios ao tempo de presa e solubilidade.


Assuntos
Propilenoglicóis/química , Materiais Restauradores do Canal Radicular/química , Ácido Salicílico/química , Espectroscopia de Ressonância Magnética , Espectroscopia de Infravermelho com Transformada de Fourier , Resistência à Tração
19.
Braz. oral res. (Online) ; 31: e3, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839508

RESUMO

Abstract A randomized, double-blind, split-mouth clinical trial was performed compared the desensitizing efficacy of the resin-modified glass ionomer cement (GIC) ClinproTM XT (3M ESPE, Minnesota, USA) and the conventional GIC Vidrion R (SS White, Gloucester, UK) in a 6-month follow-up. Subjects were required to have at least two teeth with dentin hypersensitivity. Teeth were divided at random into 2 groups, one group received Clinpro XT and the other conventional GIC Vidrion R. Treatments were assessed by tactile and air blast tests using Visual Analogue Scale (VAS) at baseline, after 20 minutes, and at 7, 15, 21, 30, 90 and 180 days post-treatment. Twenty subjects (152 teeth) were included. Both tests (tactile and air blast) showed a significant reduction of dentin hypersensitivity immediately after the application of Vidrion R and Clinpro XT (20 min). VAS scores obtained along the 6-month follow-up were statistically lower when compared to initial rates (p < 0.05). Both GIC were able to reduce dentin hypersensitivity up to 6-month post-treatment period without statistically significant differences among them (p > 0.05). Both cements provided satisfactory results in long-term dental sensitivity reduction.


Assuntos
Humanos , Masculino , Feminino , Adulto , Resinas Compostas/uso terapêutico , Dessensibilizantes Dentinários/uso terapêutico , Sensibilidade da Dentina/terapia , Cimentos de Ionômeros de Vidro/uso terapêutico , Dentina/efeitos dos fármacos , Método Duplo-Cego , Medição da Dor , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento , Escala Visual Analógica
20.
J. appl. oral sci ; 24(3): 299-307, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: lil-787540

RESUMO

ABSTRACT Objective A systematic review was conducted to analyze Brazilian scientific and technological production related to the dental materials field over the past 50 years. Material and Methods This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (Prisma) statement. Searches were performed until December 2014 in six databases: MedLine (PubMed), Scopus, LILACS, IBECS, BBO, and the Cochrane Library. Additionally, the Brazilian patent database (INPI - Instituto Nacional de Propriedade Industrial) was screened in order to get an overview of Brazilian technological development in the dental materials field. Two reviewers independently analyzed the documents. Only studies and patents related to dental materials were included in this review. Data regarding the material category, dental specialty, number of documents and patents, filiation countries, and the number of citations were tabulated and analyzed in Microsoft Office Excel (Microsoft Corporation, Redmond, Washington, United States). Results A total of 115,806 studies and 53 patents were related to dental materials and were included in this review. Brazil had 8% affiliation in studies related to dental materials, and the majority of the papers published were related to dental implants (1,137 papers), synthetic resins (681 papers), dental cements (440 papers), dental alloys (392 papers) and dental adhesives (361 papers). The Brazilian technological development with patented dental materials was smaller than the scientific production. The most patented type of material was dental alloys (11 patents), followed by dental implants (8 patents) and composite resins (7 patents). Conclusions Dental materials science has had a substantial number of records, demonstrating an important presence in scientific and technological development of dentistry. In addition, it is important to approximate the relationship between academia and industry to expand the technological development in countries such as Brazil.


Assuntos
Sociedades Científicas/estatística & dados numéricos , Bibliometria , Materiais Dentários , Jornalismo em Odontologia , Publicações Periódicas como Assunto/estatística & dados numéricos , Fatores de Tempo , Brasil , Tecnologia Odontológica/estatística & dados numéricos , Pesquisa Biomédica/estatística & dados numéricos , Invenções/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA