Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 95(8): 3909-3916, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36791228

RESUMO

Metabolite identification represents a major bottleneck in contemporary metabolomics research and a step where critical errors may occur and pass unnoticed. This is especially the case for studies employing liquid chromatography-mass spectrometry technology, where there is increased concern on the validity of the proposed identities. In the present perspective article, we describe the issue and categorize the errors into two types: identities that show poor biological plausibility and identities that do not comply with chromatographic data and thus to physicochemical properties (usually hydrophobicity/hydrophilicity) of the proposed molecule. We discuss the problem, present characteristic examples, and propose measures to improve the situation.


Assuntos
Metabolômica , Cromatografia Líquida/métodos , Metabolômica/métodos , Espectrometria de Massas/métodos , Interações Hidrofóbicas e Hidrofílicas
2.
Xenobiotica ; 53(2): 93-105, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36794569

RESUMO

The metabolism and pharmacokinetics of fasiglifam (TAK-875, 2-[(3S)-6-[[3-[2,6-dimethyl-4-(3-methylsulfonylpropoxy)phenyl]phenyl]methoxy]-2,3-dihydro-1-benzofuran-3-yl]acetic acid), a selective free fatty acid receptor 1 (FFAR1)/GPR40 agonist, were studied following intravenous (5 mg/kg) and oral administration (10 and 50 mg/kg) to male and female Sprague Dawley rats.Following intravenous dosing at 5 mg/kg, peak observed plasma concentrations of 8.8/9.2 µg/ml were seen in male and female rats respectively.Following oral dosing, peak plasma concentrations at 1 h of ca. 12.4/12.9 µg/ml for 10 mg/kg and 76.2/83.7 µg/ml for 50 mg/kg doses were obtained for male and female rats respectively. Drug concentrations then declined in the plasma of both sexes with t1/2's of 12.4 (male) and 11.2 h (female). Oral bioavailability was estimated to be 85-120% in males and females at both dose levels.Urinary excretion was low, but in a significant sex-related difference, female rats eliminated ca. 10-fold more drug-related material by this route.Fasiglifam was the principal drug-related compound in plasma, with 15 metabolites, including the acyl glucuronide, also detected. In addition to previously identified metabolites, a novel biotransformation, that produced a side-chain shortened metabolite via elimination of CH2 from the acetyl side chain was noted with implications for drug toxicity.


Assuntos
Receptores Acoplados a Proteínas G , Sulfonas , Ratos , Masculino , Feminino , Animais , Ratos Sprague-Dawley , Administração Intravenosa , Receptores Acoplados a Proteínas G/agonistas , Administração Oral , Injeções Intravenosas
3.
J Proteome Res ; 21(3): 691-701, 2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-34968064

RESUMO

Reversed-phase UHPLC-MS is extensively employed for both the profiling of biological fluids and tissues to characterize lipid dysregulation in disease and toxicological studies. With conventional LC-MS systems the chromatographic performance and throughput are limited due to dispersion from the fluidic connections as well as radial and longitudinal thermal gradients in the LC column. In this study vacuum jacketed columns (VJC), positioned at the source of the mass spectrometer, were applied to the lipidomic analysis of plasma extracts. Compared to conventional UHPLC, the VJC-based methods offered greater resolution, faster analysis, and improved peak intensity. For a 5 min VJC analysis, the peak capacity increased by 66%, peak tailing reduced by up to 34%, and the number of lipids detected increased by 30% compared to conventional UHPLC. The narrower peaks, and thus increased resolution, compared to the conventional system resulted in a 2-fold increase in peak intensity as well a significant improvement in MS and MS/MS spectral quality resulting in a 22% increase in the number of lipids identified. When applied to mouse plasma samples, reproducibility of the lipid intensities in the pooled QC ranged from 1.8-12%, with no related drift in tR observed.


Assuntos
Lipidômica , Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida de Alta Pressão/métodos , Lipídeos , Camundongos , Reprodutibilidade dos Testes , Vácuo
4.
J Proteome Res ; 21(11): 2596-2608, 2022 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-36264332

RESUMO

Lipids play a key role in many biological processes, and their accurate measurement is critical to unraveling the biology of diseases and human health. A high throughput HILIC-based (LC-MS) method for the semiquantitative screening of over 2000 lipids, based on over 4000 MRM transitions, was devised to produce an accessible and robust lipidomic screen for phospholipids in human plasma/serum. This methodology integrates many of the advantages of global lipid analysis with those of targeted approaches. Having used the method as an initial "wide class" screen, it can then be easily adapted for a more targeted analysis and quantification of key, dysregulated lipids. Robustness was assessed using 1550 continuous injections of plasma extracts onto a single column and via the evaluation of columns from 5 different batches of stationary phase. Initial screens in positive (239 lipids, 431 MRM transitions) and negative electrospray ionization (ESI) mode (232 lipids, 446 MRM transitions) were assessed for reproducibility, sensitivity, and dynamic range using analysis times of 8 min. The total number of lipids monitored using these screening methods was 433 with an overlap of 38 lipids in both modes. A polarity switching method for accurate quantification, using the same LC conditions, was assessed for intra- and interday reproducibility, accuracy, dynamic range, stability, carryover, dilution integrity, and matrix interferences and found to be acceptable. This polarity switching method was then applied to lipids important in the stratification of human prostate cancer samples.


Assuntos
Lipidômica , Espectrometria de Massas em Tandem , Masculino , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Fosfolipídeos
5.
J Proteome Res ; 20(3): 1705-1715, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33566619

RESUMO

The deployment of proteomic analysis in clinical studies represents a significant opportunity to detect and validate biomarkers in translational medicine, improve disease understanding, and provide baseline information on population health. However, comprehensive proteome studies usually employ nanoscale chromatography and often require several hours of analysis/sample. Here, we describe a high-throughput liquid chromatography tandem mass spectrometry (LC/MS/MS) methodology using 1 mm scale chromatography requiring only 15 min/sample, coupled to ion mobility-enabled mass spectrometry. The short run time effected a 6-fold increase in productivity compared with nanoscale LC/MS. The method demonstrated excellent reproducibility with retention time coefficient of variations of less than 0.05% and peak area reproducibility ranging from 5 to 15%. The 1 mm system produced similar chromatographic peak capacity values to the nanoscale miniaturized system, detecting 90% of the Escherichia coli proteins identified by the 75 µm LC/MS system (albeit based on only 75% of the peptides found by the latter). Application to the analysis of serum samples from a human prostate cancer study group resulted in the identification of a total of 533 proteins revealing the differential expression of proteins linked to patients receiving hormone-radiotherapy or undergoing surgery.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Humanos , Masculino , Reprodutibilidade dos Testes
6.
Anal Chem ; 93(30): 10644-10652, 2021 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-34279080

RESUMO

In UHPLC, frictional heating from the eluent flowing through the column at pressures of ca. 10-15 Kpsi causes radial diffusion via temperature differences between the center of the column and its walls. Longitudinal dispersion also occurs due to temperature gradients between the inlet and outlet. These effects cause band broadening but can be mitigated via a combination of vacuum jacketed stainless steel tubing, reduced column end nut mass, and a constant temperature in the column from heating the inlet fitting. Here, vacuum jacketed column (VJC) technology, employing a novel column housing located on the source of the mass spectrometer and minimized tubing from the column outlet to the electrospray probe, was applied to profiling metabolites in urine. For a 75 s reversed-phase gradient separation, the average peak widths for endogenous compounds in urine were 1.2 and 0.6 s for conventional LC/MS and VJC systems, respectively. The peak tailing factor was reduced from 1.25 to 1.13 when using the VJC system compared to conventional UHPLC, and the peak capacity increased from 65 to 120, with a 25% increase in features detected in urine. The increased resolving power of the VJC system reduced co-elution, simplifying MS and MS/MS spectra, providing a more confident metabolite identification. The increased LC performance also gave more intense MS peaks, with a 10-120% increase in response, improving the quality of the MS data and detection limits. Reducing the LC gradient duration to 37 s gave peak widths of ca. 0.4 s and a peak capacity of 84.


Assuntos
Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Difusão , Vácuo
7.
Anal Chem ; 93(20): 7413-7421, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-33984239

RESUMO

1-ß-O-Acyl-glucuronides (AGs) are common metabolites of carboxylic acid-containing xenobiotics, including, e.g., many nonsteroidal anti-inflammatory drugs (NSAIDs). They are of concern to regulatory authorities because of the association of these metabolites with the hepatotoxicity that has resulted in drug withdrawal. One factor in assessing the potential risk posed by AGs is the rate of transacylation of the biosynthetic 1-ß-O-acyl form to the 2-, 3-, and 4-O-acyl isomers. While transacylation can be measured using 1H NMR spectroscopy or liquid chromatography-mass spectrometry (LC-MS), the process can be time consuming and involve significant method development. The separation of these positional isomers by ion mobility spectrometry (IMS) has the potential to allow their rapid analysis, but conventional instruments lacked the resolving power to do this. Prediction of the collision cross section (CCS) using a machine learning model suggested that greater IMS resolution might be of use in this area. Cyclic IMS was evaluated for separating mixtures of isomeric AGs of diclofenac and was compared with a conventional ultraperformance liquid chromatography (UPLC)-MS method as a means for studying transacylation kinetics. The resolution of isomeric AGs was not seen using a conventional traveling wave IMS device; however, separation was seen after several passes around a cyclic IMS. The cyclic IMS enabled the degradation of the 1-ß-O-acyl-isomer to be analyzed much more rapidly than by LC-MS. The ability of cyclic IMS to monitor the rate of AG transacylation at different pH values, without the need for a prior chromatographic separation, should allow high-throughput, real-time, monitoring of these types of reactions.


Assuntos
Glucuronídeos , Espectrometria de Mobilidade Iônica , Diclofenaco/análogos & derivados , Espectrometria de Massas
8.
Xenobiotica ; 51(4): 434-446, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33280466

RESUMO

The metabolism and pharmacokinetics of gefitinib (Iressa®, N-(3-chloro-4-fluorophenyl)-7-methoxy-6-(3-morpholino-propoxy)quinazolin-4-amine), a selective thymidylate kinase inhibitor for the epidermal growth factor receptor (EGFR), was studied after IV and PO administration to male C57BL6 mice at 10 and 50 mg/kg respectively.The pharmacokinetics and metabolism of gefitinib were investigated using a range of rapid UHPLC-MS and UHPLC-IM-HRMS methods, using both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC), to rapidly determine the drugs pharmacokinetics and metabolic fate.Rapid oral absorption resulted in peak plasma concentrations at 1 h of ca. 7 µg/mL, that declined with a half-life of 3.8 h (2.6 h for the IV route), and providing an estimated oral bioavailability of 53%. Gefitinib itself was the major circulating drug-related compound in plasma extracts, with a total of 11 metabolites identified.The urinary profiles determined using both HILIC and RP-UPLC-IM-MS detected gefitinib and 10 metabolites or 15 metabolites respectively including the detection of a number of novel glucuronide conjugates.Despite rapid, sub 5 min, LC profiling methods being employed metabolite coverage was shown to be high and compared well with that of previous studies.


Assuntos
Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Gefitinibe , Masculino , Camundongos , Camundongos Endogâmicos C57BL
9.
J Proteome Res ; 18(11): 4055-4064, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31550900

RESUMO

The application of a data-independent acquisition (DIA) method ("SONAR") that employs a rapidly scanning quadrupole is described for the lipidomic analysis of complex biological extracts. Using this approach, the MS acquisition window can be varied between 1 and 25 Da, enabling the isolation of ions prior to their entering the collision cell. By rapidly scanning the resolving quadrupole window over a specified mass range, co-eluting precursor ions are transmitted sequentially into the collision cell, where collision energies are cycled between low and elevated levels to induce fragmentation. This method of data generation provides both precursor and fragment ion information at high specificity, allowing for greater accuracy of compound identification, whether using a database, spectral libraries, or comparison to authentic standards. The value of the approach in simplifying and "de-cluttering" the spectra of co-eluting lipids is shown with examples from lipidomic profiles obtained in investigations of the composition of organic extracts of livers obtained from SCID and chimeric liver-humanized mice administered under various experimental conditions.


Assuntos
Isoxazóis/farmacologia , Lipidômica/métodos , Lipídeos/análise , Extratos Hepáticos/metabolismo , Fígado/efeitos dos fármacos , Espectrometria de Massas/métodos , Tiofenos/farmacologia , Animais , Cromatografia Líquida/métodos , Antagonistas dos Receptores de Endotelina/farmacologia , Íons/análise , Fígado/metabolismo , Masculino , Camundongos SCID , Reprodutibilidade dos Testes
10.
Anal Chem ; 91(8): 5207-5216, 2019 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-30848589

RESUMO

A targeted ultrahigh-performance liquid chromatography tandem mass spectrometry with electrospray ionization (UHPLC-ESI-MS/MS) method has been developed for the quantification of tryptophan and its downstream metabolites from the kynurenine and serotonin pathways. The assay coverage also includes markers of gut health and inflammation, including citrulline and neopterin. The method was designed in 96-well plate format for application in multiday, multiplate clinical and epidemiology population studies. A chromatographic cycle time of 7 min enables the analysis of two 96-well plates in 24 h. To protect chromatographic column lifespan, samples underwent a two-step extraction, using solvent protein precipitation followed by delipidation via solid-phase extraction (SPE). Analytical validation reported accuracy of each analyte <20% for the lowest limit of quantification and <15% for all other quality control (QC) levels. The analytical precision for each analyte was 2.1-12.9%. To test the applicability of the method to multiplate and multiday preparations, a serum pool underwent periodic repeat analysis during a run consisting of 18 plates. The % CV (coefficient of variation) values obtained for each analyte were <15%. Additional biological testing applied the assay to samples collected from healthy control participants and two groups diagnosed with inflammatory bowel disease (IBD) (one group treated with the anti-inflammatory 5-aminosalicylic acid (5-ASA) and one group untreated), with results showing significant differences in the concentrations of picolinic acid, kynurenine, and xanthurenic acid. The short analysis time and 96-well plate format of the assay makes it suitable for high-throughput targeted UHPLC-ESI-MS/MS metabolomic analysis in large-scale clinical and epidemiological population studies.


Assuntos
Colite Ulcerativa/sangue , Colite Ulcerativa/epidemiologia , Triptofano/sangue , Adulto , Idoso , Biomarcadores/sangue , Biomarcadores/metabolismo , Cromatografia Líquida de Alta Pressão , Citrulina/sangue , Citrulina/metabolismo , Estudos de Coortes , Colite Ulcerativa/diagnóstico , Feminino , Humanos , Cinurenina/sangue , Cinurenina/metabolismo , Masculino , Pessoa de Meia-Idade , Neopterina/sangue , Neopterina/metabolismo , Controle de Qualidade , Serotonina/sangue , Serotonina/metabolismo , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Triptofano/metabolismo , Adulto Jovem
11.
Metabolomics ; 15(2): 17, 2019 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-30830424

RESUMO

INTRODUCTION: As large scale metabolic phenotyping is increasingly employed in preclinical studies and in the investigation of human health and disease the current LC-MS/MS profiling methodologies adopted for large sample sets can result in lengthy analysis times, putting strain on available resources. As a result of these pressures rapid methods of untargeted analysis may have value where large numbers of samples require screening. OBJECTIVES: To develop, characterise and evaluate a rapid UHP-HILIC-MS-based method for the analysis of polar metabolites in rat urine and then extend the capabilities of this approach by the addition of IMS to the system. METHODS: A rapid untargeted HILIC LC-MS/MS profiling method for the analysis of small polar molecules has been developed. The 3.3 min separation used a Waters BEH amide (1 mm ID) analytical column on a Waters Synapt G2-Si Q-Tof enabled with ion mobility spectrometry (IMS). The methodology, was applied to the metabolic profiling of a series of rodent urine samples from vehicle-treated control rats and animals administered tienilic acid. The same separation was subsequently linked to IMS and MS to evaluate the benefits that IMS might provide for metabolome characterisation. RESULTS: The rapid HILIC-MS method was successfully applied to rapid analysis of rat urine and found, based on the data generated from the data acquired for the pooled quality control samples analysed at regular intervals throughout the analysis, to be robust. Peak area and retention times for the compounds detected in these samples showed good reproducibility across the batch. When used to profile the urine samples obtained from vehicle-dosed control and those administered tienilic acid the HILIC-MS method detected 3007 mass/retention time features. Analysis of the same samples using HILIC-IMS-MS enabled the detection of 6711 features. Provisional metabolite identification for a number of compounds was performed using the high collision energy MS/MS information compared against the Metlin MS/MS database and, in addition, both calculated and measured CCS values from an experimentally derived CCS database. CONCLUSION: A rapid metabolic profiling method for the analysis of polar metabolites has been developed. The method has the advantages of speed and both reducing sample and solvent consumption compared to conventional profiling methods. The addition of IMS added an additional dimension for feature detection and the identification of metabolites.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Metabolômica/métodos , Urina/química , Animais , Líquidos Corporais , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Humanos , Masculino , Metaboloma , Controle de Qualidade , Ratos/urina , Ratos Sprague-Dawley/urina , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
12.
Xenobiotica ; 49(11): 1352-1359, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30557119

RESUMO

1. The metabolic fate and urinary excretion of 2-bromophenol, a phenolic metabolite of bromobenzene, was investigated in male Sprague-Dawley rats following single intraperitoneal doses at either 0, 100, or 200 mg/kg.2. Urine was collected for seven days and samples analysed using 1 H NMR spectroscopy, inductively coupled plasma (ICP)MS, and UPLC-MS.3. 1 H NMR spectroscopy of the urine samples showed that, at these doses, 2-bromophenol had little effect on endogenous metabolite profiles, supporting histopathology and clinical chemistry data, which showed no changes associated with the administration of 2-bromophenol in this study.4. The use of ICP-MS provided a means for the selective detection and quantification of bromine-containing species and showed that between 15 and 30% of the dose was excreted via the urine over 7 days of the study for both the 100 and 200 mg doses, respectively.5. The bulk of the excretion of Br-containing material had occurred by 8 h post administration. UPLC-MS of urine revealed a number of metabolites of 2-bromophenol, with 2-bromophenol glucuronide and 2-bromophenol sulphate identified as the major species. A number of minor hydroxylated metabolites were also detected as their glucuronide, sulphate, or O-methyl conjugates. There was no evidence for the production of reactive metabolites.


Assuntos
Substâncias Perigosas/toxicidade , Fenóis/toxicidade , Testes de Toxicidade , Animais , Masculino , Ratos , Ratos Sprague-Dawley
13.
Proc Natl Acad Sci U S A ; 112(8): 2431-6, 2015 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-25675482

RESUMO

Tetrahydrobiopterin is a cofactor synthesized from GTP with well-known roles in enzymatic nitric oxide synthesis and aromatic amino acid hydroxylation. It is used to treat mild forms of phenylketonuria. Less is known about the role of tetrahydrobiopterin in lipid metabolism, although it is essential for irreversible ether lipid cleavage by alkylglycerol monooxygenase. Here we found intracellular alkylglycerol monooxygenase activity to be an important regulator of alkylglycerol metabolism in intact murine RAW264.7 macrophage-like cells. Alkylglycerol monooxygenase was expressed and active also in primary mouse bone marrow-derived monocytes and "alternatively activated" M2 macrophages obtained by interleukin 4 treatment, but almost missing in M1 macrophages obtained by IFN-γ and lipopolysaccharide treatment. The cellular lipidome of RAW264.7 was markedly changed in a parallel way by modulation of alkylglycerol monooxygenase expression and of tetrahydrobiopterin biosynthesis affecting not only various ether lipid species upstream of alkylglycerol monooxygenase but also other more complex lipids including glycosylated ceramides and cardiolipins, which have no direct connection to ether lipid pathways. Alkylglycerol monooxygenase activity manipulation modulated the IFN-γ/lipopolysaccharide-induced expression of inducible nitric oxide synthase, interleukin-1ß, and interleukin 1 receptor antagonist but not transforming growth factor ß1, suggesting that alkylglycerol monooxygenase activity affects IFN-γ/lipopolysaccharide signaling. Our results demonstrate a central role of tetrahydrobiopterin and alkylglycerol monooxygenase in ether lipid metabolism of murine macrophages and reveal that alteration of alkylglycerol monooxygenase activity has a profound impact on the lipidome also beyond the class of ether lipids.


Assuntos
Biopterinas/análogos & derivados , Metabolismo dos Lipídeos/efeitos dos fármacos , Macrófagos/metabolismo , Oxigenases de Função Mista/metabolismo , Animais , Biopterinas/farmacologia , Células da Medula Óssea/citologia , Diferenciação Celular/efeitos dos fármacos , Linhagem Celular , Células Cultivadas , Análise por Conglomerados , GTP Cicloidrolase/metabolismo , Técnicas de Silenciamento de Genes , Interferon gama/farmacologia , Lentivirus/metabolismo , Lipopolissacarídeos/farmacologia , Macrófagos/citologia , Macrófagos/efeitos dos fármacos , Macrófagos/enzimologia , Camundongos , Monócitos/citologia , Monócitos/efeitos dos fármacos , Monócitos/enzimologia , Óxido Nítrico Sintase Tipo II/metabolismo
14.
Anal Chem ; 89(4): 2478-2487, 2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-28194962

RESUMO

A targeted reversed-phase gradient UPLC-MS/MS assay has been developed for the quantification /monitoring of 66 amino acids and amino-containing compounds in human plasma and serum using precolumn derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AccQTag Ultra). Derivatization of the target amines required minimal sample preparation and resulted in analytes with excellent chromatographic and mass spectrometric detection properties. The resulting method, which requires only 10 µL of sample, provides the reproducible and robust separation of 66 analytes in 7.5 min, including baseline resolution of isomers such as leucine and isoleucine. The assay has been validated for the quantification of 33 amino compounds (predominantly amino acids) over a concentration range from 2 to 20 and 800 µM. Intra- and interday accuracy of between 0.05 and 15.6 and 0.78-13.7% and precision between 0.91 and 16.9% and 2.12-15.9% were obtained. A further 33 biogenic amines can be monitored in samples for relative changes in concentration rather than quantification. Application of the assay to samples derived from healthy controls and patients suffering from acetaminophen (APAP, paracetamol)-induced acute liver failure (ALF) showed significant differences in the amounts of aromatic and branched chain amino acids between the groups as well as a number of other analytes, including the novel observation of increased concentrations of sarcosine in ALF patients. The properties of the developed assay, including short analysis time, make it suitable for high-throughput targeted UPLC-ESI-MS/MS metabonomic analysis in clinical and epidemiological environments.


Assuntos
Aminas/sangue , Aminoquinolinas/química , Carbamatos/química , Doença Hepática Induzida por Substâncias e Drogas/diagnóstico , Cromatografia Líquida de Alta Pressão/métodos , Acetaminofen/toxicidade , Adulto , Aminas/química , Aminoácidos/análise , Doença Hepática Induzida por Substâncias e Drogas/metabolismo , Feminino , Humanos , Limite de Detecção , Masculino , Espectrometria de Massas por Ionização por Electrospray
15.
Anal Chem ; 88(11): 5742-51, 2016 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-27116471

RESUMO

A rapid gradient microbore ultraperformance liquid chromatography-mass spectrometry (UPLC-MS) method has been developed to provide a high-throughput analytical platform for the metabolic phenotyping of urine from large sample cohorts. The rapid microbore metabolic profiling (RAMMP) approach was based on scaling a conventional reversed-phase UPLC-MS method for urinary profiling from 2.1 mm × 100 mm columns to 1 mm × 50 mm columns, increasing the linear velocity of the solvent, and decreasing the gradient time to provide an analysis time of 2.5 min/sample. Comparison showed that conventional UPLC-MS and rapid gradient approaches provided peak capacities of 150 and 50, respectively, with the conventional method detecting approximately 19 000 features compared to the ∼6 000 found using the rapid gradient method. Similar levels of repeatability were seen for both methods. Despite the reduced peak capacity and the reduction in ions detected, the RAMMP method was able to achieve similar levels of group discrimination as conventional UPLC-MS when applied to rat urine samples obtained from investigative studies on the effects of acute 2-bromophenol and chronic acetaminophen administration. When compared to a direct infusion MS method of similar analysis time the RAMMP method provided superior selectivity. The RAMMP approach provides a robust and sensitive method that is well suited to high-throughput metabonomic analysis of complex mixtures such as urine combined with a 5-fold reduction in analysis time compared with the conventional UPLC-MS method.


Assuntos
Acetaminofen/urina , Ensaios de Triagem em Larga Escala , Fenóis/urina , Acetaminofen/metabolismo , Animais , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Metaboloma , Metabolômica , Fenóis/metabolismo , Fenótipo , Ratos
16.
J Proteome Res ; 14(6): 2714-21, 2015 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-25917015

RESUMO

A new generation of metabolic phenotyping centers are being created to meet the increasing demands of personalized healthcare, and this has resulted in a major requirement for economical, high-throughput metabonomic analysis by liquid chromatography-mass spectrometry (LC-MS). Meeting these new demands represents an emerging bioanalytical problem that must be solved if metabolic phenotyping is to be successfully applied to large clinical and epidemiological sample sets. Ultraperformance (UP)LC-MS-based metabolic phenotyping, based on 2.1 mm i.d. LC columns, enables comprehensive metabolic phenotyping but, when employed for the analysis of thousands of samples, results in high solvent usage. The use of UPLC-MS employing 1 mm i.d. columns for metabolic phenotyping rather than the conventional 2.1 mm i.d. methodology shows that the resulting optimized microbore method provided equivalent or superior performance in terms of peak capacity, sensitivity, and robustness. On average, we also observed, when using the microbore scale separation, an increase in response of 2-3 fold over that obtained with the standard 2.1 mm scale method. When applied to the analysis of human urine, the 1 mm scale method showed no decline in performance over the course of 1000 analyses, illustrating that microbore UPLC-MS represents a viable alternative to conventional 2.1 mm i.d. formats for routine large-scale metabolic profiling studies while also resulting in a 75% reduction in solvent usage. The modest increase in sensitivity provided by this methodology also offers the potential to either reduce sample consumption or increase the number of metabolite features detected with confidence due to the increased signal-to-noise ratios obtained. Implementation of this miniaturized UPLC-MS method of metabolic phenotyping results in clear analytical, economic, and environmental benefits for large-scale metabolic profiling studies with similar or improved analytical performance compared to conventional UPLC-MS.


Assuntos
Cromatografia Líquida/métodos , Estudos Epidemiológicos , Espectrometria de Massas/métodos , Urina , Humanos , Fenótipo , Reprodutibilidade dos Testes
17.
Anal Chem ; 87(2): 1137-44, 2015 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-25495617

RESUMO

Despite recent advances in analytical and computational chemistry, lipid identification remains a significant challenge in lipidomics. Ion-mobility spectrometry provides an accurate measure of the molecules' rotationally averaged collision cross-section (CCS) in the gas phase and is thus related to ionic shape. Here, we investigate the use of CCS as a highly specific molecular descriptor for identifying lipids in biological samples. Using traveling wave ion mobility mass spectrometry (MS), we measured the CCS values of over 200 lipids within multiple chemical classes. CCS values derived from ion mobility were not affected by instrument settings or chromatographic conditions, and they were highly reproducible on instruments located in independent laboratories (interlaboratory RSD < 3% for 98% of molecules). CCS values were used as additional molecular descriptors to identify brain lipids using a variety of traditional lipidomic approaches. The addition of CCS improved the reproducibility of analysis in a liquid chromatography-MS workflow and maximized the separation of isobaric species and the signal-to-noise ratio in direct-MS analyses (e.g., "shotgun" lipidomics and MS imaging). These results indicate that adding CCS to databases and lipidomics workflows increases the specificity and selectivity of analysis, thus improving the confidence in lipid identification compared to traditional analytical approaches. The CCS/accurate-mass database described here is made publicly available.


Assuntos
Encéfalo/metabolismo , Lipídeos/análise , Espectrometria de Massa de Íon Secundário/métodos , Idoso , Cromatografia Líquida , Humanos , Razão Sinal-Ruído
18.
Analyst ; 140(6): 1921-31, 2015 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-25655051

RESUMO

The emergence of micro sampling techniques holds great potential to improve pharmacokinetic data quality, reduce animal usage, and save costs in safety assessment studies. The analysis of these samples presents new challenges for bioanalytical scientists, both in terms of sample processing and analytical sensitivity. The use of two dimensional LC/MS with, at-column-dilution for the direct analysis of highly organic extracts prepared from biological fluids such as dried blood spots and plasma is demonstrated. This technique negated the need to dry down and reconstitute, or dilute samples with water/aqueous buffer solutions, prior to injection onto a reversed-phase LC system. A mixture of model drugs, including bromhexine, triprolidine, enrofloxacin, and procaine were used to test the feasibility of the method. Finally an LC/MS assay for the probe pharmaceutical rosuvastatin was developed from dried blood spots and protein-precipitated plasma. The assays showed acceptable recovery, accuracy and precision according to US FDA guidelines. The resulting analytical method showed an increase in assay sensitivity of up to forty fold as compared to conventional methods by maximizing the amount loaded onto the system and the MS response for the probe pharmaceutical rosuvastatin from small volume samples.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Teste em Amostras de Sangue Seco/instrumentação , Análise de Injeção de Fluxo/instrumentação , Espectrometria de Massas/instrumentação , Preparações Farmacêuticas/sangue , Desenho de Equipamento , Fluorbenzenos/sangue , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/sangue , Compostos Orgânicos , Plasma/química , Pirimidinas/sangue , Reprodutibilidade dos Testes , Rosuvastatina Cálcica , Tamanho da Amostra , Solventes , Sulfonamidas/sangue
19.
Analyst ; 140(16): 5546-56, 2015 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-26146891

RESUMO

An integrated capillary scale (300 µm id) ceramic microfluidic LC system combined with MS/MS has been successfully employed for the quantitative analysis of pharmaceutical compounds in human plasma. The capillary ceramic microfluidic LC/MS/MS system showed an approximate 20-fold (range 11-38-fold) increase in sensitivity compared with a standard 2.1 mm scale UPLC/MS/MS system for a broad range of analytes. The loading capacity of the devices capillary separations channel allowed injection of 2 µL of an aqueous solution, and up to 1.2 µL of a typical protein-precipitated plasma sample, onto the reversed-phase chromatography system. The system also showed excellent chromatographic performance and robustness, with no deleterious effects on the chromatography observed over the course of 1000 injections of protein-precipitated plasma. The ability of the ceramic microfluidic LC/MS/MS system to deliver this level of sensitivity and performance enables the routine quantification of pharmaceutical compounds from small format samples, such as those obtained by dried blood spot or other blood microsampling approaches, to be performed.


Assuntos
Cerâmica/química , Cromatografia Líquida/métodos , Teste em Amostras de Sangue Seco/instrumentação , Dispositivos Lab-On-A-Chip , Preparações Farmacêuticas/sangue , Plasma/química , Espectrometria de Massas em Tandem/métodos , Humanos , Preparações Farmacêuticas/química
20.
J Proteome Res ; 13(9): 4143-54, 2014 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-25126707

RESUMO

Exposure to ionizing radiation has dramatically increased in modern society, raising serious health concerns. The molecular response to ionizing radiation, however, is still not completely understood. Here, we screened mouse serum for metabolic alterations following an acute exposure to γ radiation using a multiplatform mass-spectrometry-based strategy. A global, molecular profiling revealed that mouse serum undergoes a series of significant molecular alterations following radiation exposure. We identified and quantified bioactive metabolites belonging to key biochemical pathways and low-abundance, oxygenated, polyunsaturated fatty acids (PUFAs) in the two groups of animals. Exposure to γ radiation induced a significant increase in the serum levels of ether phosphatidylcholines (PCs) while decreasing the levels of diacyl PCs carrying PUFAs. In exposed mice, levels of pro-inflammatory, oxygenated metabolites of arachidonic acid increased, whereas levels of anti-inflammatory metabolites of omega-3 PUFAs decreased. Our results indicate a specific serum lipidomic biosignature that could be utilized as an indicator of radiation exposure and as novel target for therapeutic intervention. Monitoring such a molecular response to radiation exposure might have implications not only for radiation pathology but also for countermeasures and personalized medicine.


Assuntos
Ácidos Graxos Ômega-3/sangue , Ácidos Graxos Ômega-3/metabolismo , Metaboloma/efeitos da radiação , Metabolômica/métodos , Radiação Ionizante , Animais , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Fenótipo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA