Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 30(12): e741-e752, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33930556

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is standard of care for rotator cuff evaluation, with clinical interpretation usually limited to qualitative judgments. The reliability of MRI-based measurements and scoring systems has been evaluated only preoperatively or ≥6 months following rotator cuff repair, when repairs are in the later stages of healing. This study describes the MRI assessments and inter-rater agreement of various rotator cuff tendon and muscle parameters evaluated preoperatively and 4 times during the first postoperative year. METHODS: Two musculoskeletal radiologists independently assessed MRI scans of 42 patients preoperatively and 3, 12, 26, and 52 weeks after rotator cuff repair. Using standardized reading rules, readers assessed tendon integrity (5-point Sugaya classification), tear dimensions, muscle fat (5-point Goutallier classification) and atrophy (4-point Warner classification), muscle cross-sectional areas, and myotendinous junction distance. Raw exact agreement proportions, κ statistics, and correlation coefficients were used to quantify inter-rater agreement. RESULTS: Readers showed moderate to substantial above-chance agreement in scoring rotator cuff tendon integrity and supraspinatus muscle atrophy and good to excellent agreement on tear dimensions and muscle cross-sectional areas but only fair to moderate agreement for fatty infiltration and myotendinous junction distance. Only fatty infiltration grades evidenced observer bias. Inter-rater agreement did not appear time dependent. CONCLUSION: By use of defined reading rules in a research setting, MRI evaluations of rotator cuff tendon integrity, tear dimensions, muscle atrophy, and cross-sectional areas have reasonable reliability at all time points in the first postoperative year. However, the presence of clinically significant disagreements, even in such favorable circumstances, indicates the need for improved imaging tools for precise rotator cuff evaluation.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Humanos , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia
2.
AJR Am J Roentgenol ; 215(2): 441-447, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32374669

RESUMO

OBJECTIVE. Cartilage loss on preoperative knee MRI is a predictor of poor outcomes after arthroscopic partial meniscectomy. The purpose of this study was to compare the ability to predict outcomes after arthroscopic partial meniscectomy with a clinically used modified Outerbridge system versus a semiquantitative MRI Osteoarthritis Knee Score system for grading cartilage loss. MATERIALS AND METHODS. Patients who underwent preoperative knee MRI within 6 months of arthroscopic partial meniscectomy and who had outcomes available from the time of surgery and 1 year later were eligible for inclusion. Cases were evaluated by two radiologists and one radiology fellow with the use of both grading systems. The accuracy of each system in discriminating between surgical success and failure was estimated using the ROC curve (AUC) with 95% CIs. A Wald test was used to assess noninferiority of the clinical grading system. Interreader agreement regarding the accuracy of the grading systems in predicting outcomes was also compared. RESULTS. A total of 78 patients (38 women and 40 men; mean age, 56.6 years) were included in the study. A prediction model using clinical grading (AUC = 0.695; 95% CI, 0.566-0.824) was noninferior (p = 0.047) to a model using MRI Osteoarthritis Knee Score grading (AUC = 0.683; 95% CI, 0.539-0.827). Both MRI prediction models performed better than a model using demographic characteristics only (AUC = 0.667; 95% CI, 0.522-0.812). Inter-reader agreement with clinical grading (80.8%) was higher than that with MRI Osteoarthritis Knee Score grading (65.0%; p = 0.012). CONCLUSION. A clinically used system to grade cartilage loss on MRI is as effective as a semiquantitative system for predicting outcomes after arthroscopic partial meniscectomy, while also offering improved interreader agreement.


Assuntos
Artroscopia , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Imageamento por Ressonância Magnética , Meniscectomia/métodos , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
3.
AJR Am J Roentgenol ; 210(3): 593-600, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29231758

RESUMO

OBJECTIVE: The objective of this study was to compare reader accuracy detecting lesions near hardware in a CT phantom model at different radiation exposures using an advanced metal artifact reduction (MAR) algorithm and standard filtered back projection (FBP) techniques and to determine if radiation exposure could be decreased using MAR without compromising lesion detectability. MATERIALS AND METHODS: A CT phantom manufactured with spherical lesions of various sizes (10-20 mm) and attenuations (20-50 HU) embedded around cobalt-chromium spheres attached to titanium rods, simulating an arthroplasty, was scanned on a single CT scanner (FLASH, Siemens Healthcare) at 140 kVp and 0.6-mm collimation using clinical-dose (300 Quality Reference mAs [Siemens Healthcare]), low-dose (150 Quality Reference mAs), and high-dose (600 Quality Reference mAs) protocols. Images reconstructed with iterative MAR, advanced modeled iterative reconstruction (ADMIRE), and FBP with identical parameters were anonymized and independently reviewed by three radiologists. Accuracies for detecting lesions, measured as AUC, sensitivity, and specificity, were compared. RESULTS: Accuracy using MAR was significantly higher than that using FBP at all exposures (p values ranged from < 0.001 to 0.021). Sensitivity was also higher for MAR than for FBP at all exposures. Specificity was very high for both reconstruction techniques at all exposures with no significant differences. Accuracy of low-dose MAR was higher than and not inferior to standard-dose and high-dose FBP. MAR was significantly more sensitive than FBP in detecting smaller lesions (p = 0.021) and lesions near high streak artifact (p < 0.001). CONCLUSION: MAR improves reader accuracy to detect lesions near hardware and allows significant reductions in radiation exposure without compromising accuracy compared with FBP in a CT phantom model.


Assuntos
Artefatos , Metais , Próteses e Implantes , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas
4.
Skeletal Radiol ; 47(1): 107-116, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28952012

RESUMO

PURPOSE: To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI. MATERIALS AND METHODS: One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol. RESULTS: Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI. CONCLUSION: A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee.


Assuntos
Traumatismos do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
5.
AJR Am J Roentgenol ; 208(4): W146-W154, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28140650

RESUMO

OBJECTIVE: The purpose of this study was to compare the diagnostic performance of a 5-minute shoulder MRI protocol consisting of multiplanar 2D fast spin-echo (FSE) sequences with parallel imaging to that of a standard shoulder MRI protocol. MATERIALS AND METHODS: A retrospective review of 151 3-T MRI examinations of shoulders of 147 patients (mean age, 46.95 years) and 50 1.5-T MRI examinations of shoulders of 50 patients (mean age, 53.74 years) with four fast and five standard sequences from two academic centers between January 2014 and April 2015 was performed by three musculoskeletal radiologists. Interchangeability of fast and standard MRI was tested by comparing interprotocol (fast vs standard) interreader agreement with standard MRI interreader agreement. Interreader agreement was also compared using kappa statistics. The frequency of major findings was compared using an adjusted McNemar test. Sensitivity and specificity of MRI were measured for 51 patients who underwent surgery. RESULTS: Interprotocol reader agreement was essentially equal to reader agreement on standard MRI (mean difference ≤ 1%; 95% CI, -3.8% to 3.9%; 61-96% across structures). Interprotocol kappa values (0.373-0.645) were similar to standard MRI kappa values (0.320-0.726). Frequencies of major findings on fast and standard MRI were similar (0.7-19.6% across structures; p ≥ 0.08). Sensitivities of fast MRI for tendon and labral tears (33-92%) were equivalent or higher than those of standard MRI with similar specificities (77-98%). CONCLUSION: Fast 5-minute shoulder MRI with multiplanar 2D FSE sequences using parallel imaging is interchangeable, with similar interreader agreement and accuracy, with standard shoulder MRI for evaluating shoulder injuries.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Guias de Prática Clínica como Assunto , Lesões do Ombro/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , New York , Variações Dependentes do Observador , Ohio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
6.
AJR Am J Roentgenol ; 207(2): 378-85, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27186794

RESUMO

OBJECTIVE: The purpose of this study was to compare iterative metal artifact reduction (iMAR), a new single-energy metal artifact reduction technique, with filtered back projection (FBP) in terms of attenuation values, qualitative image quality, and streak artifacts near shoulder and hip arthroplasties and observer ability with these techniques to detect pathologic lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS: Preoperative and postoperative CT scans of 40 shoulder and 21 hip arthroplasties were reviewed. All postoperative scans were obtained using the same technique (140 kVp, 300 quality reference mAs, 128 × 0.6 mm detector collimation) on one of three CT scanners and reconstructed with FBP and iMAR. The attenuation differences in bones and soft tissues between preoperative and postoperative scans at the same location were compared; image quality and streak artifact for both reconstructions were qualitatively graded by two blinded readers. Observer ability and confidence to detect lesions near an arthroplasty in a phantom model were graded. RESULTS: For both readers, iMAR had more accurate attenuation values (p < 0.001), qualitatively better image quality (p < 0.001), and less streak artifact (p < 0.001) in all locations near arthroplasties compared with FBP. Both readers detected more lesions (p ≤ 0.04) with higher confidence (p ≤ 0.01) with iMAR than with FBP in the phantom model. CONCLUSION: The iMAR technique provided more accurate attenuation values, better image quality, and less streak artifact near hip and shoulder arthroplasties than FBP; iMAR also increased observer ability and confidence to detect pathologic lesions near arthroplasties in a phantom model.


Assuntos
Artroplastia de Quadril , Artroplastia do Ombro , Prótese de Quadril , Prótese de Ombro , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
7.
Skeletal Radiol ; 45(1): 41-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26305059

RESUMO

OBJECTIVE: To describe the MR appearance of a series of throwing-related injuries to the subscapularis muscle-tendon complex among baseball players. MATERIALS AND METHODS: A retrospective review of MR scans of the shoulder in players from 1 professional baseball organization over the course of 5 years was performed to identify cases with findings suggestive of subscapularis injury. These findings were graded and the medical record was reviewed to assess clinical findings, treatment, and follow-up. Preinjury baseline measurements of arm external rotation at 90° of abduction were compared to measurements from a noninjured cohort to evaluate whether this measure is a risk factor for injury. RESULTS: A total of 133 MR scans of the shoulder were evaluated. Eleven of the scans demonstrated signal changes suggesting subscapularis injury; 10 of these 11 patients had clinical findings supporting a diagnosis of throwing-related subscapularis strain. There were four grade 1, four grade 2, and two grade 3 injuries. All injuries occurred in the inferior half of the subscapularis at the myotendinous junction. Risk of subscapularis injury increased with lower levels of dominant arm external rotation (odds ratio, 1.12; 95% CI, 1.07-1.21; p < 0.001). A threshold of dominant arm external rotation of <106° demonstrated sensitivity of 0.700 (95% CI, 0.392-0.897) and specificity of 0.951 (95% CI, 0.888-0.982) for subscapularis injury. CONCLUSION: Throwing-related subscapularis injuries occur in the inferior half of the muscle at the myotendinous junction. Our data suggest that there is an increased risk of these injuries with lower levels of dominant arm external rotation.


Assuntos
Beisebol/lesões , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/lesões , Lesões do Ombro , Articulação do Ombro/patologia , Traumatismos dos Tendões/patologia , Adulto , Traumatismos do Braço/patologia , Traumatismos em Atletas/patologia , Feminino , Humanos , Estudos Longitudinais , Masculino , Músculo Esquelético/patologia , Estudos Retrospectivos , Adulto Jovem
8.
Skeletal Radiol ; 43(12): 1729-35, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25172218

RESUMO

OBJECTIVE: Iterative metal artifact reduction (IMAR) is a sinogram inpainting technique that incorporates high-frequency data from standard weighted filtered back projection (WFBP) reconstructions to reduce metal artifact on computed tomography (CT). This study was designed to compare the image quality of IMAR and WFBP in total shoulder arthroplasties (TSA); determine the optimal amount of WFBP high-frequency data needed for IMAR; and compare image quality of the standard 3D technique with that of a faster 2D technique. MATERIALS AND METHODS: Eight patients with nine TSA underwent CT with standardized parameters: 140 kVp, 300 mAs, 0.6 mm collimation and slice thickness, and B30 kernel. WFBP, three 3D IMAR algorithms with different amounts of WFBP high-frequency data (IMARlo, lowest; IMARmod, moderate; IMARhi, highest), and one 2D IMAR algorithm were reconstructed. Differences in attenuation near hardware and away from hardware were measured and compared using repeated measures ANOVA. Five readers independently graded image quality; scores were compared using Friedman's test. RESULTS: Attenuation differences were smaller with all 3D IMAR techniques than with WFBP (p < 0.0063). With increasing high-frequency data, the attenuation difference increased slightly (differences not statistically significant). All readers ranked IMARmod and IMARhi more favorably than WFBP (p < 0.05), with IMARmod ranked highest for most structures. The attenuation difference was slightly higher with 2D than with 3D IMAR, with no significant reader preference for 3D over 2D. CONCLUSIONS: IMAR significantly decreases metal artifact compared to WFBP both objectively and subjectively in TSA. The incorporation of a moderate amount of WFBP high-frequency data and use of a 2D reconstruction technique optimize image quality and allow for relatively short reconstruction times.


Assuntos
Artefatos , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Algoritmos , Análise de Variância , Artroplastia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
AJR Am J Roentgenol ; 198(6): W575-80, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22623573

RESUMO

OBJECTIVE: The objective of our study was to determine the accuracy of MRI in diagnosing meniscal tears in older patients and the frequency with which abnormal MRI findings correlate with degeneration, fraying, and tears at arthroscopy. MATERIALS AND METHODS: Ninety-two patients 50 years old or older who had undergone knee MRI followed by knee arthroscopy within 6 months were selected. Menisci were graded on a 5-point scale: 1, definitely no tear; 2, probably no tear; 3, indeterminate or equivocal; 4, probably a tear; and 5, definitely a tear. Meniscal signal changes, meniscal surface morphology, and extrameniscal abnormalities were noted. Operative notes were reviewed, and the sensitivity and specificity of MRI results were calculated. RESULTS: For medial tears, MRI had a sensitivity and specificity of 0.91 and 0.94, respectively, when grade 5 was considered a tear, 0.96 and 0.76 when grades 4 and 5 were considered a tear, and 0.99 and 0.47 when grades 3-5 were considered a tear. For lateral tears, MRI had a sensitivity and specificity of 0.73 and 0.91 when grade 5 was considered a tear, 0.88 and 0.80 when grades 4 and 5 were considered a tear, and 1.0 and 0.61 when grades 3-5 were considered a tear. The positive predictive values (PPVs) of MRI for the medial meniscus were 99%, grade 5; 57%, grade 4; 29%, grade 3; 25%, grade 2; and 0%, grade 1. For the lateral meniscus, the PPVs of MRI were 76%, grade 5; 36%, grade 4; 19%, grade 3; and 0%, grades 1 and 2. CONCLUSION: The accuracy of MRI for diagnosing meniscal tears in older patients is high and similar to that in younger patients when only definitive findings are considered a tear. The specificity decreases if equivocal or probable findings are considered a tear.


Assuntos
Traumatismos do Joelho/diagnóstico , Imageamento por Ressonância Magnética/métodos , Lesões do Menisco Tibial , Idoso , Artroscopia , Intervalos de Confiança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
10.
JSES Int ; 6(6): 948-956, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36353424

RESUMO

Background: Magnetic resonance imaging (MRI)-based rotator cuff assessment is often qualitative and subjective; few studies have tried to validate such preoperative assessments. This study investigates relationships of preoperative MRI assessments made by conventional approaches to intraoperative findings of tear type, location, and size or MRI-assessed muscle occupation ratio. Methods: Intraoperatively, surgeons assessed tear type, location, anterior-posterior (AP) width, and medial-lateral length in 102 rotator cuff repair patients. Two musculoskeletal radiologists independently assessed the preoperative MRI scans for these same parameters and supraspinatus muscle atrophy by both Warner classification and quantitative occupation ratio. Exact agreement proportions, kappa statistics, and correlation coefficients were used to quantify agreement relationships. Results: Agreement between MRI readers' and surgeons' observations of tear status averaged 93% with κ = 0.38, and that of tear location averaged 77% with κ = 0.50. Concordance correlations of MRI and intraoperative measures of anterior-posterior and medial-lateral tear length averaged 0.59 and 0.56 across readers, respectively. Despite excellent interrater agreement on Warner classification (exact agreement proportion 0.91) and occupation ratio (concordance correlation 0.93) separately, correlations between these 2 measures were -0.54 and -0.64 for the 2 readers, respectively. Patients with Warner grade 0 had occupation ratios ranging from 0.5 to 1.5. Conclusion: Correlations of preoperative MRI tear dimensions and muscle atrophy assessed by conventional approaches with intraoperatively measured tear dimensions and quantitative occupation ratio, respectively, were only fair. Since tear size and muscle atrophy are known strong predictors of outcomes following rotator cuff repair that may influence treatment decisions, surgeons need to be aware of the limitations of MRI methods. Continued development and validation of quantitative preoperative imaging methods to accurately assess these parameters are needed to improve surgical planning and prognosis.

11.
AJR Am J Roentgenol ; 197(2): 442-50, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21785092

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the diagnostic performance of sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) 3D fast spin-echo acquisition relative to conventional 2D fast spin-echo acquisition in the 3-T MRI evaluation of the menisci and ligaments of the knee. MATERIALS AND METHODS: Images from all MRI knee examinations performed with a single 3-T system from September 2008 to January 2009 were reviewed. Seventy-one examinations of patients who subsequently underwent knee arthroscopy and an additional 29 examinations of patients who did not undergo surgery were selected for a total of 100 examinations. All imaging was performed with multiplanar conventional 2D and SPACE 3D fast spin-echo acquisitions. Six musculoskeletal radiologists independently reviewed the images. Area under the receiver operating characteristic (ROC) curve was calculated for the menisci and anterior cruciate ligament with arthroscopy as the reference standard. Disagreement between the two acquisitions was calculated for the posterior cruciate ligament and medial and lateral collateral ligaments. The Wilcoxon signed rank test was used to compare each reader's confidence scores for the two techniques. RESULTS: For the medial meniscus, the average area under the ROC curve was statistically significantly larger (p = 0.01) with the conventional 2D (0.931) than with the SPACE 3D (0.893) technique. Average confidence in diagnosing medial meniscal tears also was statistically significantly greater with the 2D than with the 3D technique (p = 0.001). No statistically significant differences were found for the lateral meniscus or anterior cruciate ligament. The rate of discordance between findings with the 2D and 3D techniques was low for the posterior cruciate ligament and medial and lateral collateral ligaments (range, 4.2-5.7%). CONCLUSION: In evaluation of menisci with 3-T MRI, readers performed better with conventional 2D acquisition than with SPACE 3D acquisition. In evaluation of ligaments, the readers had similar performance with the two acquisition methods.


Assuntos
Imageamento Tridimensional , Traumatismos do Joelho/diagnóstico , Ligamentos Articulares/lesões , Imageamento por Ressonância Magnética/métodos , Lesões do Menisco Tibial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroscopia , Distribuição de Qui-Quadrado , Criança , Feminino , Humanos , Traumatismos do Joelho/cirurgia , Ligamentos Articulares/cirurgia , Masculino , Meniscos Tibiais/cirurgia , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Estatísticas não Paramétricas
12.
Skeletal Radiol ; 40(10): 1275-85, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21618061

RESUMO

OBJECTIVES: To determine the prevalence of vacuum phenomenon (VP) in the knee on magnetic resonance (MR) images, describe the imaging features that characterize VP, and assess how often VP mimics pathological knee lesions. MATERIALS AND METHODS: Consecutive knee MR studies performed on a 3 T MR system over a 9-month period were retrospectively reviewed by one radiologist who then selected studies with findings potentially indicating VP. Three experienced musculoskeletal radiologists reviewed these cases in consensus to confirm the presence of VP and to assess the shape, size, and signal of VP; the presence of magnetic susceptibility artifacts; and the ability of MR sequences to show VP. RESULTS: A total of 914 consecutive exams from 875 patients (524 men; mean age, 35 years) were reviewed. Vacuum phenomenon was found in 12 patients (prevalence 1.3%). In six (50%) patients, VP mimicked a meniscal tear, with four cases simulating a torn medial discoid meniscus. The VP signal was not easily differentiated from meniscal signal on most sequences in most cases (9/12). Gradient-recalled echo (GRE) localizer images proved most definitive, with 3D SPACE images the next most effective. Fast spin echo (FSE) images were only occasionally able to differentiate VP from meniscus. CONCLUSION: Rarely recognized on MR, VP can mimic meniscal pathology, potentially leading to inappropriate surgery. Because differentiation of VP from the meniscus is challenging on FSE at 3 T, radiologists should become familiar with the appearance of VP and review GRE localizer or 3D images carefully to avoid misinterpretation.


Assuntos
Artefatos , Articulação do Joelho , Imageamento por Ressonância Magnética , Vácuo , Adolescente , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Imageamento Tridimensional , Masculino , Meniscos Tibiais/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
AJR Am J Roentgenol ; 195(3): 577-84, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20729433

RESUMO

OBJECTIVE: Our aim is to review several shoulder abnormalities that are difficult to detect accurately on shoulder MRI, describe the technical reasons that limit their detection, and suggest imaging protocol modifications that may improve radiologists' accuracy. CONCLUSION: Although MRI is an excellent tool for detecting some abormalities, there are a number of subtler abnormalities of clinical significance that give radiologists greater difficulty. By understanding the reasons for limited detection and modifying protocols accordingly, radiologists may be able to improve identification, allowing more accurate clinical decision making.


Assuntos
Doenças das Cartilagens/diagnóstico , Artropatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Articulação do Ombro/patologia , Artroscopia , Doenças das Cartilagens/patologia , Doenças das Cartilagens/fisiopatologia , Meios de Contraste , Diagnóstico Diferencial , Humanos , Artropatias/patologia , Artropatias/fisiopatologia , Músculo Esquelético/lesões , Lesões do Ombro , Articulação do Ombro/fisiopatologia
14.
Skeletal Radiol ; 39(10): 1025-31, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20419450

RESUMO

The purpose of this study was to optimize CT arthrography technique and determine if dual energy CT (DECT) can provide any benefit over single energy CT (SECT). Iodinated contrast attenuation at different concentrations was measured using DECT and SECT at different beam energies (140, 120, and 80 kVp). Dose and noise were measured on phantoms at different tube currents. Three bovine femoral condyles with artificially created cartilage defects were scanned with dose-equivalent protocols. Contrast-to-noise ratio (CNR) between cartilage and iodine was measured, and the appearance of cartilage defects was graded by two readers. DECT scans were post-processed for iodine quantification. The beam energy 80 kVp had the highest iodine signal, 50% greater than DECT, 75% greater than 120 kVp, and 100% greater than 140 kVp. Noise was nearly identical for all techniques when dose was matched. The 80 kVp level had the highest CNR, 25% higher than 120 kVp and DECT, and 33% greater than 140 kVp. The 80 kVp technique was also preferred by both readers. DECT iodine quantification was significantly limited by the post-processing application, noise, and beam hardening. In this in-vitro study, the SECT 80 kVp CT arthrography technique was superior to currently performed 120 and 140 kVP SECT techniques and DECT.


Assuntos
Artrografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Cadáver , Bovinos , Meios de Contraste , Colo do Fêmur/diagnóstico por imagem , Humanos , Técnicas In Vitro , Iohexol/análogos & derivados , Articulação do Joelho/diagnóstico por imagem , Variações Dependentes do Observador , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos
15.
J Shoulder Elbow Surg ; 19(6): 899-907, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20381384

RESUMO

HYPOTHESIS: Humeral version is highly variable in human beings. Accurate assessment of humeral version may allow for more anatomic reconstruction at shoulder arthroplasty. Two-dimensional (2D) computed tomography (CT) has been used to measure humeral version but has limitations of poor interobserver reproducibility and strict dependence on arm positioning during image acquisition. This study evaluated a new technique, 3-dimensional (3D) volume rendering, for measuring humeral version. MATERIALS AND METHODS: Eight dried human humerus specimens were included in the study. Gold standard measurements of humeral version were obtained by use of metallic beads and fluoroscopy. The specimens were then scanned at CT in 2 different positions, 1 neutral to the table and 1 angled at 20 degrees . The image data sets were used to measure humeral version in each bone with both the standard 2D technique and the new 3D technique. Measurements were performed by 3 readers at 2 different time points. Readers were blinded to the gold standard results and each others' measurements. RESULTS: For all readers, 3D measurements averaged within 4.3 degrees of the gold standard. For 2 of the 3 readers, 3D measurements were more accurate than 2D measurements. For all 3 readers, intraobserver variability was better with the 3D technique. For all reader pairs, interobserver variability was better with the 3D technique. CONCLUSIONS: This study shows a 3D volume-rendering CT technique to measure humeral version accurately and consistently that is independent of patient positioning.


Assuntos
Úmero/diagnóstico por imagem , Imageamento Tridimensional , Tomografia Computadorizada por Raios X/métodos , Artroplastia de Substituição , Cadáver , Humanos , Curva ROC , Reprodutibilidade dos Testes , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
16.
Magn Reson Imaging Clin N Am ; 28(2): 243-255, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32241661

RESUMO

In this article, the authors aim to focus on the challenges of interpreting shoulder MR imaging in the throwing athlete with an approach formed by evidence-based literature and clinical experience, with a particular focus on superior labrum tears.


Assuntos
Traumatismos em Atletas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Lesões do Ombro , Articulação do Ombro/diagnóstico por imagem , Humanos
17.
Radiology ; 252(1): 225-31, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19435939

RESUMO

The purpose of this HIPAA-compliant study was to prospectively evaluate the feasibility of contrast material-enhanced computed tomography (CT) with digital bone masking for the evaluation of synovitis and tenosynovitis in patients with rheumatoid arthritis. Four patients with rheumatoid arthritis and findings at magnetic resonance (MR) imaging were evaluated after informed consent for this institutional review board-approved study was obtained. To improve the conspicuity of synovial enhancement, postcontrast CT was performed with a relatively low kilovoltage and high iodine concentration and precontrast images were used as a subtraction mask to eliminate high-attenuation cortical bone contours. Moderate to high agreement between CT and MR imaging findings for synovitis and tenosynovitis was demonstrated, which suggests that this technique may be an acceptable alternative to MR imaging in the evaluation of rheumatoid arthritis.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Osso e Ossos/diagnóstico por imagem , Iohexol/análogos & derivados , Intensificação de Imagem Radiográfica/métodos , Técnica de Subtração , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Knee ; 25(2): 279-285, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29525550

RESUMO

BACKGROUND: We sought to determine whether there are ultrasound parameters that differ between knees with symptomatic fat pad synovial impingement and asymptomatic knees. METHODS: A prospective study was performed in patients with clinical signs and symptoms of fat pad synovial impingement and asymptomatic controls. Eleven symptomatic knees and 10 asymptomatic controls were evaluated. Ultrasound imaging was performed before and after exercise. Evaluated parameters included largest fat lobule compressibility, subjective assessment of vascularity, largest vessel diameter, and subjective assessment of dynamic fat pad motion during flexion and extension. Receiver operating characteristic (ROC) curve analysis was used to assess whether changes in these parameters were different between symptomatic and asymptomatic knees. RESULTS: Change in the largest vessel diameter was greater and trended toward dilation in asymptomatic knees compared to symptomatic knees (mean: 0.83 vs. -0.02; P<0.001). No significant differences were observed between symptomatic and asymptomatic knees with respect to pre-exercise versus post-exercise states in subjective assessment of vascularity (P=0.131), fat pad motion (P=0.115), or percent change of the largest fat lobule (P=0.241). However, overall compressibility of the fat pad lobule was significantly diminished in the pre-exercise state in symptomatic knees compared to asymptomatic controls. CONCLUSIONS: This study demonstrated a statistically significant change in the largest vessel diameter from pre- to post-exercise states between symptomatic and asymptomatic knees, as well as abnormal pre-exercise fat lobule compressibility in symptomatic knees. These findings show promise that with further research, ultrasound could have clinical utility in diagnosing infrapatellar fat pad impingement.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Tecido Adiposo/irrigação sanguínea , Adolescente , Adulto , Doenças Assintomáticas , Estudos de Casos e Controles , Exercício Físico , Humanos , Estudos Prospectivos , Ultrassonografia , Adulto Jovem
19.
Radiol Clin North Am ; 54(5): 801-15, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27545421

RESUMO

Repetitive, high-velocity overhead throwing can lead to several adaptive changes in the throwing shoulder, which over time lead to structural microtrauma and eventually overt injury. MR imaging is a useful imaging modality to evaluate these changes and to characterize their acuity and severity. Understanding the throwing motion and the effects of this motion on the structures of the shoulder can help radiologists to recognize these findings and provide useful information to referring physicians, which may affect the treatment of these athletes. This article reviews shoulder pathomechanics and MR imaging findings in overhead throwing athletes.


Assuntos
Traumatismos em Atletas/diagnóstico por imagem , Beisebol/lesões , Transtornos Traumáticos Cumulativos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Lesões do Ombro/diagnóstico por imagem , Lesões dos Tecidos Moles/diagnóstico por imagem , Diagnóstico Diferencial , Humanos , Articulação do Ombro/diagnóstico por imagem
20.
Am J Sports Med ; 41(1): 134-41, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23019253

RESUMO

BACKGROUND: Ten to seventy percent of rotator cuff repairs form a recurrent defect after surgery. The relationship between retraction of the repaired tendon and formation of a recurrent defect is not well defined. PURPOSE/ HYPOTHESES: To measure the prevalence, timing, and magnitude of tendon retraction after rotator cuff repair and correlate these outcomes with formation of a full-thickness recurrent tendon defect on magnetic resonance imaging, as well as clinical outcomes. We hypothesized that (1) tendon retraction is a common phenomenon, although not always associated with a recurrent defect; (2) formation of a recurrent tendon defect correlates with the timing of tendon retraction; and (3) clinical outcome correlates with the magnitude of tendon retraction at 52 weeks and the formation of a recurrent tendon defect. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Fourteen patients underwent arthroscopic rotator cuff repair. Tantalum markers placed within the repaired tendons were used to assess tendon retraction by computed tomography scan at 6, 12, 26, and 52 weeks after operation. Magnetic resonance imaging was performed to assess for recurrent tendon defects. Shoulder function was evaluated using the Penn score, visual analog scale (VAS) score for pain, and isometric scapular-plane abduction strength. RESULTS: All rotator cuff repairs retracted away from their position of initial fixation during the first year after surgery (mean [standard deviation], 16.1 [5.3] mm; range, 5.7-23.2 mm), yet only 30% of patients formed a recurrent defect. Patients who formed a recurrent defect tended to have more tendon retraction during the first 6 weeks after surgery (9.7 [6.0] mm) than those who did not form a defect (4.1 [2.2] mm) (P = .08), but the total magnitude of tendon retraction was not significantly different between patient groups at 52 weeks. There was no significant correlation between the magnitude of tendon retraction and the Penn score (r = 0.01, P = .97) or normalized scapular abduction strength (r = -0.21, P = .58). However, patients who formed a recurrent defect tended to have lower Penn scores at 52 weeks (P = .1). CONCLUSION: Early tendon retraction, but not the total magnitude, correlates with formation of a recurrent tendon defect and worse clinical outcomes. "Failure with continuity" (tendon retraction without a recurrent defect) appears to be a common phenomenon after rotator cuff repair. These data suggest that repairs should be protected in the early postoperative period and repair strategies should endeavor to mechanically and biologically augment the repair during this critical early period.


Assuntos
Complicações Pós-Operatórias/diagnóstico por imagem , Lesões do Manguito Rotador , Traumatismos dos Tendões/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ohio/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Prevalência , Estudos Prospectivos , Radiografia , Manguito Rotador/diagnóstico por imagem , Traumatismos dos Tendões/complicações , Traumatismos dos Tendões/diagnóstico por imagem , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA