Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Med ; 117: 103203, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38171219

RESUMO

Setup errors are an important factor in the dosimetric accuracy of radiotherapy delivery. In this study, we investigated how rotational setup errors influence the dose distribution in volumetric modulated arc therapy (VMAT) and tangential field-in-field (FiF) treatment of left-sided breast cancer with supraclavicular lymph node involvement in deep inspiration breath hold. Treatment planning computed tomography images and radiotherapy plans of 20 patients were collected retrospectively for the study. Rotational setup errors up to 3° were simulated by rotating the planning images, and the resulting dosimetric changes were calculated. With rotational setup errors up to 3°, the median decrease of V95% to clinical target volume was less than 0.8 percentage point in both VMAT and FiF plans. The dose distribution of the heart and left anterior descending artery was more stable with respect to rotations in VMAT plans compared to FiF plans. Correction of ≥1° setup errors is recommended due to increased doses to the heart and left anterior descending artery after 1° setup errors.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Neoplasias Unilaterais da Mama/diagnóstico por imagem , Neoplasias Unilaterais da Mama/radioterapia , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Órgãos em Risco
2.
Med Phys ; 48(11): 6765-6780, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34580883

RESUMO

PURPOSE: An antibubble is an encapsulated gas bubble with an incompressible inclusion inside the gas phase. Current-generation ultrasound contrast agents are bubble-based: they contain encapsulated gas bubbles with no inclusions. The objective of this work is to determine the linear and nonlinear responses of an antibubble contrast agent in comparison to two bubble-based ultrasound contrast agents, that is, reference bubbles and SonoVue TM . METHODS: Side scatter and attenuation of the three contrast agents were measured, using single-element ultrasound transducers, operating at 1.0, 2.25, and 3.5 MHz. The scatter measurements were performed at acoustic pressures of 200 and 300 kPa for 1.0 MHz, 300 kPa, and 450 kPa for 2.25 MHz, and 370 and 560 kPa for 3.5 MHz. Attenuation measurements were conducted at pressures of 13, 55, and 50 kPa for 1.0, 2.25, and 3.5 MHz, respectively. In addition, a dynamic contrast-enhanced ultrasound measurement was performed, imaging the contrast agent flow through a vascular phantom with a commercial diagnostic linear array probe. RESULTS: Antibubbles generated equivalent or stronger harmonic signal, compared to bubble-based ultrasound contrast agents. The second harmonic side-scatter amplitude of the antibubble agent was up to 3 dB greater than that of reference bubble agent and up to 4 dB greater than that of SonoVue TM at the estimated concentration of 8 × 10 4 bubbles/mL. For ultrasound with a center transmit frequency of 1.0 MHz, the attenuation coefficient of the antibubble agent was 8.7 dB/cm, whereas the attenuation coefficient of the reference agent was 7.7 and 0.3 dB/cm for SonoVue TM . At 2.25 MHz, the attenuation coefficients were 9.7, 3.0, and 0.6 dB/cm, respectively. For 3.5 MHz, they were 4.4, 1.8, and 1.0 dB/cm, respectively. A dynamic contrast-enhanced ultrasound recording showed the nonlinear signal of the antibubble agent to be 31% greater than for reference bubbles and 23% lower than SonoVue TM at a high concentration of 2 × 10 6 bubbles/mL. CONCLUSION: Endoskeletal antibubbles generate comparable or greater higher harmonics than reference bubbles and SonoVue TM . As a result, antibubbles with liquid therapeutic agents inside the gas phase have high potential to become a traceable therapeutic agent.


Assuntos
Acústica , Meios de Contraste , Microbolhas , Imagens de Fantasmas , Fenômenos Físicos , Ultrassonografia
3.
Front Public Health ; 9: 593417, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33643988

RESUMO

Interest in the mathematical modeling of infectious diseases has increased due to the COVID-19 pandemic. However, many medical students do not have the required background in coding or mathematics to engage optimally in this approach. System dynamics is a methodology for implementing mathematical models as easy-to-understand stock-flow diagrams. Remarkably, creating stock-flow diagrams is the same process as creating the equivalent differential equations. Yet, its visual nature makes the process simple and intuitive. We demonstrate the simplicity of system dynamics by applying it to epidemic models including a model of COVID-19 mutation. We then discuss the ease with which far more complex models can be produced by implementing a model comprising eight differential equations of a Chikungunya epidemic from the literature. Finally, we discuss the learning environment in which the teaching of the epidemic modeling occurs. We advocate the widespread use of system dynamics to empower those who are engaged in infectious disease epidemiology, regardless of their mathematical background.


Assuntos
COVID-19 , Doenças Transmissíveis , Simulação por Computador , Modelos Teóricos , Pandemias , Algoritmos , Humanos , SARS-CoV-2
4.
J Acoust Soc Am ; 126(6): 3286-90, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20000942

RESUMO

The anisotropic pore structure and elasticity of cancellous bone cause wave speeds and attenuation in cancellous bone to vary with angle. Previously published predictions of the variation in wave speed with angle are reviewed. Predictions that allow tortuosity to be angle dependent but assume isotropic elasticity compare well with available data on wave speeds at large angles but less well for small angles near the normal to the trabeculae. Claims for predictions that only include angle-dependence in elasticity are found to be misleading. Audio-frequency data obtained at audio-frequencies in air-filled bone replicas are used to derive an empirical expression for the angle-and porosity-dependence of tortuosity. Predictions that allow for either angle dependent tortuosity or angle dependent elasticity or both are compared with existing data for all angles and porosities.


Assuntos
Osso e Ossos/fisiologia , Elasticidade , Som , Acústica , Ar , Algoritmos , Animais , Anisotropia , Bovinos , Humanos , Modelos Biológicos , Porosidade
5.
Ultrason Sonochem ; 14(4): 438-44, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17218145

RESUMO

Ultrasound contrast agents consist of microscopically small bubbles encapsulated by an elastic shell. These microbubbles oscillate upon ultrasound insonification, and demonstrate highly nonlinear behavior, ameliorating their detectability. (Potential) medical applications involving the ultrasonic disruption of contrast agent microbubble shells include release-burst imaging, localized drug delivery, and noninvasive blood pressure measurement. To develop and enhance these techniques, predicting the cracking behavior of ultrasound-insonified encapsulated microbubbles has been of importance. In this paper, we explore microbubble behavior in an ultrasound field, with special attention to the influence of the bubble shell. A bubble in a sound field can be considered a forced damped harmonic oscillator. For encapsulated microbubbles, the presence of a shell has to be taken into account. In models, an extra damping parameter and a shell stiffness parameter have been included, assuming that Hooke's Law holds for the bubble shell. At high acoustic amplitudes, disruptive phenomena have been observed, such as microbubble fragmentation and ultrasonic cracking. We analyzed the occurrence of ultrasound contrast agent fragmentation, by simulating the oscillating behavior of encapsulated microbubbles with various sizes in a harmonic acoustic field. Fragmentation occurs exclusively during the collapse phase and occurs if the kinetic energy of the collapsing microbubble is greater than the instantaneous bubble surface energy, provided that surface instabilities have grown big enough to allow for break-up. From our simulations it follows that the Blake critical radius is not a good approximation for a fragmentation threshold. We demonstrated how the phase angle differences between a damped radially oscillating bubble and an incident sound field depend on shell parameters.


Assuntos
Microbolhas , Preparações Farmacêuticas/química , Ultrassom , Cobre/química , Cristalografia por Raios X , Difusão , Nanopartículas Metálicas/química
6.
Ultrasonics ; 76: 92-98, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28086110

RESUMO

A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams, in the treatment of a variety of solid tumors implanted to various organs of small animals at the depth of the order of 1-2cm under the skin. To allow focusing of the beam, generated by such transducer, within treated tissue at different depths, a spherical, 2-MHz, 29-mm diameter annular phased array transducer was designed and built. To prove its potential for preclinical studies on small animals, multiple thermal lesions were induced in a pork loin ex vivo by heating beams of the same: 6W, or 12W, or 18W acoustic power and 25mm, 30mm, and 35mm focal lengths. Time delay for each annulus was controlled electronically to provide beam focusing within tissue at the depths of 10mm, 15mm, and 20mm. The exposure time required to induce local necrosis was determined at different depths using thermocouples. Location and extent of thermal lesions determined from numerical simulations were compared with those measured using ultrasound and magnetic resonance imaging techniques and verified by a digital caliper after cutting the tested tissue samples. Quantitative analysis of the results showed that the location and extent of necrotic lesions on the magnetic resonance images are consistent with those predicted numerically and measured by caliper. The edges of lesions were clearly outlined although on ultrasound images they were fuzzy. This allows to conclude that the use of the transducer designed offers an effective noninvasive tool not only to induce local necrotic lesions within treated tissue without damaging the surrounding tissue structures but also to test various chemotherapeutics activated by the HIFU beams in preclinical studies on small animals.


Assuntos
Antineoplásicos/farmacologia , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Transdutores , Animais , Desenho de Equipamento , Carne Vermelha , Suínos , Temperatura
7.
Artigo em Inglês | MEDLINE | ID: mdl-27254862

RESUMO

Attenuation of ultrasound in tissue can be estimated from the propagating pulse center frequency downshift. This method assumes that the envelope of the emitted pulse can be approximated by a Gaussian function and that the attenuation linearly depends on frequency. The resulting downshift of the mean frequency depends not only on attenuation but also on pulse bandwidth and propagation distance. This kind of approach is valid for narrowband pulses and shallow penetration depth. However, for short pulses and deep penetration, the frequency downshift is rather large and the received spectra are modified by the limited bandwidth of the receiving system. In this paper, the modified formula modeling the mean frequency of backscattered echoes is presented. The equation takes into account the limitation of the bandwidth due to bandpass filtration of the received echoes. This approach was applied to simulate the variation of the mean frequency of the pulse propagating for both weakly and strongly attenuating media and for narrowband and wideband pulses. The behavior of both the standard and modified estimates of attenuation has been validated using RF data from a tissue-mimicking phantom. The ultrasound attenuation of the phantom, determined with a corrected equation, was close to its true value, while the result obtained using the original formula was lower by as much as 50% at a depth of 8 cm.


Assuntos
Algoritmos , Processamento de Sinais Assistido por Computador , Ultrassonografia/métodos , Imagens de Fantasmas , Razão Sinal-Ruído
8.
Ultrasonics ; 68: 108-19, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26938326

RESUMO

In research and industrial processes, it is increasingly common practice to combine multiple measurement modalities. Nevertheless, experimental tools that allow the co-linear combination of optical and ultrasonic transmission have rarely been reported. The aim of this study was to develop and characterise a water-matched ultrasound transducer architecture using standard components, with a central optical window larger than 10 mm in diameter allowing for optical transmission. The window can be used to place illumination or imaging apparatus such as light guides, miniature cameras, or microscope objectives, simplifying experimental setups. Four design variations of a basic architecture were fabricated and characterised with the objective to assess whether the variations influence the acoustic output. The basic architecture consisted of a piezoelectric ring and a glass disc, with an aluminium casing. The designs differed in piezoelectric element dimensions: inner diameter, ID=10 mm, outer diameter, OD=25 mm, thickness, TH=4 mm or ID=20 mm, OD=40 mm, TH=5 mm; glass disc dimensions OD=20-50 mm, TH=2-4 mm; and details of assembly. The transducers' frequency responses were characterised using electrical impedance spectroscopy and pulse-echo measurements, the acoustic propagation pattern using acoustic pressure field scans, the acoustic power output using radiation force balance measurements, and the acoustic pressure using a needle hydrophone. Depending on the design and piezoelectric element dimensions, the resonance frequency was in the range 350-630 kHz, the -6 dB bandwidth was in the range 87-97%, acoustic output power exceeded 1 W, and acoustic pressure exceeded 1 MPa peak-to-peak. 3D stress simulations were performed to predict the isostatic pressure required to induce material failure and 4D acoustic simulations. The pressure simulations indicated that specific design variations could sustain isostatic pressures up to 4.8 MPa.The acoustic simulations were able to predict the behaviour of the fabricated devices. A total of 480 simulations, varying material dimensions (piezoelectric ring ID, glass disc diameter, glass thickness) and drive frequency indicated that the emitted acoustic profile varies nonlinearly with these parameters.


Assuntos
Transdutores , Ultrassom/instrumentação , Acústica , Desenho de Equipamento , Vidro
9.
J Control Release ; 243: 172-181, 2016 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-27744037

RESUMO

BACKGROUND: The primary aim of our study was to evaluate the safety and potential toxicity of gemcitabine combined with microbubbles under sonication in inoperable pancreatic cancer patients. The secondary aim was to evaluate a novel image-guided microbubble-based therapy, based on commercially available technology, towards improving chemotherapeutic efficacy, preserving patient performance status, and prolonging survival. METHODS: Ten patients were enrolled and treated in this Phase I clinical trial. Gemcitabine was infused intravenously over 30min. Subsequently, patients were treated using a commercial clinical ultrasound scanner for 31.5min. SonoVue® was injected intravenously (0.5ml followed by 5ml saline every 3.5min) during the ultrasound treatment with the aim of inducing sonoporation, thus enhancing therapeutic efficacy. RESULTS: The combined therapeutic regimen did not induce any additional toxicity or increased frequency of side effects when compared to gemcitabine chemotherapy alone (historical controls). Combination treated patients (n=10) tolerated an increased number of gemcitabine cycles compared with historical controls (n=63 patients; average of 8.3±6.0cycles, versus 13.8±5.6cycles, p=0.008, unpaired t-test). In five patients, the maximum tumour diameter was decreased from the first to last treatment. The median survival in our patients (n=10) was also increased from 8.9months to 17.6months (p=0.011). CONCLUSIONS: It is possible to combine ultrasound, microbubbles, and chemotherapy in a clinical setting using commercially available equipment with no additional toxicities. This combined treatment may improve the clinical efficacy of gemcitabine, prolong the quality of life, and extend survival in patients with pancreatic ductal adenocarcinoma.


Assuntos
Carcinoma Ductal Pancreático/terapia , Desoxicitidina/análogos & derivados , Microbolhas/uso terapêutico , Neoplasias Pancreáticas/terapia , Terapia por Ultrassom/métodos , Idoso , Antimetabólitos Antineoplásicos/administração & dosagem , Antimetabólitos Antineoplásicos/efeitos adversos , Antimetabólitos Antineoplásicos/uso terapêutico , Carcinoma Ductal Pancreático/patologia , Terapia Combinada , Desoxicitidina/administração & dosagem , Desoxicitidina/efeitos adversos , Desoxicitidina/uso terapêutico , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Taxa de Sobrevida , Resultado do Tratamento , Gencitabina
10.
Med Phys ; 32(12): 3707-11, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16475770

RESUMO

Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microbubbles at higher frame rates than the ultrasonic frequency transmitted. Microbubbles with thin lipid shells have been observed to act as microsyringes during one single ultrasonic cycle. This jetting phenomenon presumably causes sonoporation. Furthermore, we observed that the gas content can be forced out of albumin-encapsulated microbubbles. These free bubbles have been observed to jet, too. It is concluded that microbubbles might act as a vehicle to carry a drug in gas phase to a region of interest, where it has to be released by diagnostic ultrasound. This opens up a whole new area of potential applications of diagnostic ultrasound related to targeted imaging and therapeutic delivery of drugs such as nitric oxide.


Assuntos
Microbolhas , Ultrassom , Fenômenos Biofísicos , Biofísica , Sistemas de Liberação de Medicamentos , Humanos , Fotografação , Fatores de Tempo , Terapia por Ultrassom , Ultrassonografia
11.
Artigo em Inglês | MEDLINE | ID: mdl-16118985

RESUMO

We investigated gas release from two hardshelled ultrasound contrast agents by subjecting them to high-mechanical index (MI) ultrasound and simultaneously capturing high-speed photographs. At an insonifying frequency of 1.7 MHz, a larger percentage of contrast bubbles is seen to crack than at 0.5 MHz. Most of the released gas bubbles have equilibrium diameters between 1.25 and 1.75 microm. Their disappearance was observed optically. Free gas bubbles have equilibrium diameters smaller than the bubbles from which they have been released. Coalescence may account for the long dissolution times acoustically observed and published in previous studies. After sonic cracking, the cracked bubbles stay acoustically active.


Assuntos
Meios de Contraste , Gases/química , Microbolhas , Albumina Sérica/análise , Albumina Sérica/ultraestrutura , Ultrassom , Ultrassonografia/métodos , Gases/análise , Gases/efeitos da radiação , Tamanho da Partícula , Albumina Sérica/química , Albumina Sérica/efeitos da radiação , Albumina Sérica Humana
12.
Biomed Tech (Berl) ; 60(1): 77-87, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25367613

RESUMO

Studying the effects of ultrasound on biological cells requires extensive knowledge of both the physical ultrasound and cellular biology. Translating knowledge between these fields can be complicated and time consuming. With the vast range of ultrasonic equipment available, nearly every research group uses different or unique devices. Hence, recreating the experimental conditions and results may be expensive or difficult. For this reason, we have developed devices to combat the common problems seen in state-of-the-art biomedical ultrasound research. In this paper, we present the design, fabrication, and characterisation of an open-source device that is easy to manufacture, allows for parallel sample sonication, and is highly reproducible, with complete acoustic calibration. This device is designed to act as a template for sample sonication experiments. We demonstrate the fabrication technique for devices designed to sonicate 24-well plates and OptiCell™ using three-dimensional (3D) printing and low-cost consumables. We increased the pressure output by electrical impedance matching of the transducers using transmission line transformers, resulting in an increase by a factor of 3.15. The devices cost approximately €220 in consumables, with a major portion attributed to the 3D printing, and can be fabricated in approximately 8 working hours. Our results show that, if our protocol is followed, the mean acoustic output between devices has a variance of <1%. We openly provide the 3D files and operation software allowing any laboratory to fabricate and use these devices at minimal cost and without substantial prior know-how.


Assuntos
Técnicas de Cultura de Células/instrumentação , Ensaios de Triagem em Larga Escala/instrumentação , Sonicação/instrumentação , Manejo de Espécimes/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
13.
Ultrasound Med Biol ; 41(7): 1913-26, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25929996

RESUMO

Microbubble oscillation at specific ultrasound settings leads to permeabilization of surrounding cells. This phenomenon, referred to as sonoporation, allows for the in vitro and in vivo delivery of extracellular molecules, including plasmid DNA. To date, the biological and physical mechanisms underlying this phenomenon are not fully understood. The aim of this study was to investigate the interactions between microbubbles and cells, as well as the intracellular routing of plasmid DNA and microbubbles, during and after sonoporation. High-speed imaging and fluorescence confocal microscopy of HeLa cells stably expressing enhanced green fluorescent protein fused with markers of cellular compartments were used for this investigation. Soft-shelled microbubbles were observed to enter cells during sonoporation using experimental parameters that led to optimal gene transfer. They interacted with the plasma membrane in a specific area stained with fluorescent cholera subunit B, a marker of lipid rafts. This process was not observed with hard-shelled microbubbles, which were not efficient in gene delivery under our conditions. The plasmid DNA was delivered to late endosomes after 3 h post-sonoporation, and a few were found in the nucleus after 6 h. Gene transfer efficacy was greatly inhibited when cells were treated with chlorpromazine, an inhibitor of the clathrin-dependent endocytosis pathway. In contrast, no significant alteration was observed when cells were treated with filipin III or genistein, both inhibitors of the caveolin-dependent pathway. This study emphasizes that microbubble-cell interactions do not occur randomly during sonoporation; microbubble penetration inside cells affects the efficacy of gene transfer at specific ultrasound settings; and plasmid DNA uptake is an active mechanism that involves the clathrin-dependent pathway.


Assuntos
Clatrina/metabolismo , Eletroporação/métodos , Endocitose/fisiologia , Plasmídeos/genética , Sonicação/métodos , Transfecção/métodos , Permeabilidade da Membrana Celular/fisiologia , Permeabilidade da Membrana Celular/efeitos da radiação , Endocitose/efeitos da radiação , Células HeLa , Humanos , Microbolhas , Plasmídeos/administração & dosagem , Plasmídeos/química , Transdução de Sinais/fisiologia , Transdução de Sinais/efeitos da radiação , Ondas Ultrassônicas
14.
Ultrasound Med Biol ; 30(6): 827-40, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15219962

RESUMO

When encapsulated microbubbles are subjected to high-amplitude ultrasound, the following phenomena have been reported: oscillation, translation, coalescence, fragmentation, sonic cracking and jetting. In this paper, we explain these phenomena, based on theories that were validated for relatively big, free (not encapsulated) gas bubbles. These theories are compared with high-speed optical observations of insonified contrast agent microbubbles. Furthermore, the potential clinical applications of the bubble-ultrasound interaction are explored. We conclude that most of the results obtained are consistent with free gas bubble theory. Similar to cavitation theory, the number of fragments after bubble fission is in agreement with the dominant spherical harmonic oscillation mode. Remarkable are our observations of jetting through contrast agent microbubbles. The pressure at the tip of a jet is high enough to penetrate any human cell. Hence, liquid jets may act as remote-controlled microsyringes, delivering a drug to a region-of-interest. Encapsulated microbubbles have (potential) clinical applications in both diagnostics and therapeutics.


Assuntos
Meios de Contraste , Microbolhas , Ultrassonografia/métodos , Acústica , Humanos , Modelos Teóricos
15.
Ultrasound Med Biol ; 30(10): 1337-44, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15582233

RESUMO

We studied the interaction of ultrasound contrast agent bubbles coated with a layer of lipids, driven by 0.5 MHz ultrasound. High-speed photography on the submicrosecond timescale reveals that some bubbles bounce off each other, while others show very fast coalescence during bubble expansion. This fast coalescence cannot be explained by dissipation-limited film drainage rates. We conclude that the lipid shell ruptures upon expansion, exposing clean free bubble interfaces that support plug flow profiles in the film and inertia-limited drainage whose time scales match those of the observed coalescence.


Assuntos
Meios de Contraste , Microbolhas , Ultrassom , Modelos Teóricos , Tamanho da Partícula , Fotografação/métodos
16.
Ultrasonics ; 42(1-9): 759-62, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15047379

RESUMO

This paper describes a noninvasive method to measure local hydrostatic pressures in fluid filled cavities. The method is based on the disappearance time of a gas bubble, as the disappearance time is related to the hydrostatic pressure. When a bubble shrinks, its response to ultrasound changes. From this response, the disappearance time, and with it the hydrostatic pressure, can be determined. We investigated the applicability of the gases Ar, C(3)F(8), Kr, N(2), Ne, and SF(6), based on their diffusive properties. For pressure measurements with a limited duration, e.g. 150 ms, Kr and Ar bubbles are most suitable, since they are most sensitive to pressure change. If there is also a limitation to bubble size, e.g. a maximum diameter of 6 microm, SF(6) is most suitable. We present improvements of a method that correlates the duration of the decay of the fundamental ultrasound response to the hydrostatic overpressure. We propose to correlate the duration until subharmonic occurrence in combination with its decay, to hydrostatic overpressure, since the subharmonic decays more rapidly than the fundamental response. For a dissolving Ar gas bubble with an initial diameter of 14 microm, the overpressure can be determined 4 times as precise from the decay of the subharmonic response as from the decay of the fundamental response. Overpressures as small as 11 mmHg may be discriminated with this method.


Assuntos
Gases/química , Microesferas , Ultrassom , Meios de Contraste/química , Pressão Hidrostática , Modelos Teóricos
17.
Ultrasonics ; 54(8): 2151-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25015000

RESUMO

Single clouds of cavitation bubbles, driven by 254kHz focused ultrasound at pressure amplitudes in the range of 0.48-1.22MPa, have been observed via high-speed shadowgraphic imaging at 1×10(6) frames per second. Clouds underwent repetitive growth, oscillation and collapse (GOC) cycles, with shock-waves emitted periodically at the instant of collapse during each cycle. The frequency of cloud collapse, and coincident shock-emission, was primarily dependent on the intensity of the focused ultrasound driving the activity. The lowest peak-to-peak pressure amplitude of 0.48MPa generated shock-waves with an average period of 7.9±0.5µs, corresponding to a frequency of f0/2, half-harmonic to the fundamental driving. Increasing the intensity gave rise to GOC cycles and shock-emission periods of 11.8±0.3, 15.8±0.3, 19.8±0.2µs, at pressure amplitudes of 0.64, 0.92 and 1.22MPa, corresponding to the higher-order subharmonics of f0/3, f0/4 and f0/5, respectively. Parallel passive acoustic detection, filtered for the fundamental driving, revealed features that correlated temporally to the shock-emissions observed via high-speed imaging, p(two-tailed) < 0.01 (r=0.996, taken over all data). Subtracting the isolated acoustic shock profiles from the raw signal collected from the detector, demonstrated the removal of subharmonic spectral peaks, in the frequency domain. The larger cavitation clouds (>200µm diameter, at maximum inflation), that developed under insonations of peak-to-peak pressure amplitudes >1.0MPa, emitted shock-waves with two or more fronts suggesting non-uniform collapse of the cloud. The observations indicate that periodic shock-emissions from acoustically driven cavitation clouds provide a source for the cavitation subharmonic signal, and that shock structure may be used to study intra-cloud dynamics at sub-microsecond timescales.

18.
Mol Imaging Biol ; 16(1): 53-62, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23877869

RESUMO

PURPOSE: Adenocarcinoma of the pancreas remains one of the most lethal human cancers. The high mortality rates associated with this form of cancer are subsequent to late-stage clinical presentation and diagnosis, when surgery is rarely possible and of modest chemotherapeutic impact. Survival rates following diagnosis with advanced pancreatic cancer are very low; typical mortality rates of 50% are expected within 3 months of diagnosis. However, adjuvant chemotherapy improves the prognosis of patients even after palliative surgery, and successful newer neoadjuvant chemotherapeutical modalities have recently been reported. For patients whose tumours appear unresectable, chemotherapy remains the only option. During the past two decades, the nucleoside analogue gemcitabine has become the first-line chemotherapy for pancreatic adenocarcinoma. In this study, we aim to increase the delivery of gemcitabine to pancreatic tumours by exploring the effect of sonoporation for localised drug delivery of gemcitabine in an orthotopic xenograft mouse model of pancreatic cancer. EXPERIMENTAL DESIGN: An orthotopic xenograft mouse model of luciferase expressing MIA PaCa-2 cells was developed, exhibiting disease development similar to human pancreatic adenocarcinoma. Subsequently, two groups of mice were treated with gemcitabine alone and gemcitabine combined with sonoporation; saline-treated mice were used as a control group. A custom-made focused ultrasound transducer using clinically safe acoustic conditions in combination with SonoVue® ultrasound contrast agent was used to induce sonoporation in the localised region of the primary tumour only. Whole-body disease development was measured using bioluminescence imaging, and primary tumour development was measured using 3D ultrasound. RESULTS: Following just two treatments combining sonoporation and gemcitabine, primary tumour volumes were significantly lower than control groups. Additional therapy dramatically inhibited primary tumour growth throughout the course of the disease, with median survival increases of up to 10% demonstrated in comparison to the control groups. CONCLUSION: Combined sonoporation and gemcitabine therapy significantly impedes primary tumour development in an orthotopic xenograft model of human pancreatic cancer, suggesting additional clinical benefits for patients treated with gemcitabine in combination with sonoporation.


Assuntos
Desoxicitidina/análogos & derivados , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas/patologia , Sonicação/métodos , Carga Tumoral , Ensaios Antitumorais Modelo de Xenoenxerto , Animais , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Desoxicitidina/farmacologia , Desoxicitidina/uso terapêutico , Sistemas de Liberação de Medicamentos , Humanos , Camundongos , Camundongos SCID , Microbolhas , Reprodutibilidade dos Testes , Análise de Sobrevida , Transdutores , Carga Tumoral/efeitos dos fármacos , Ultrassom/instrumentação , Gencitabina
19.
Gene ; 525(2): 191-9, 2013 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-23566843

RESUMO

Microbubbles first developed as ultrasound contrast agents have been used to assist ultrasound for cellular drug and gene delivery. Their oscillation behavior during ultrasound exposure leads to transient membrane permeability of surrounding cells, facilitating targeted local delivery. The increased cell uptake of extracellular compounds by ultrasound in the presence of microbubbles is attributed to a phenomenon called sonoporation. In this review, we summarize current state of the art concerning microbubble-cell interactions and cellular effects leading to sonoporation and its application for gene delivery. Optimization of sonoporation protocol and composition of microbubbles for gene delivery are discussed.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Técnicas de Transferência de Genes , Ultrassom , Animais , Permeabilidade da Membrana Celular , Humanos , Microbolhas
20.
Med Phys ; 40(7): 072902, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23822453

RESUMO

PURPOSE: The purpose of this study was to investigate the ability and efficacy of inducing sonoporation in a clinical setting, using commercially available technology, to increase the patients' quality of life and extend the low Eastern Cooperative Oncology Group performance grade; as a result increasing the overall survival in patients with pancreatic adenocarcinoma. METHODS: Patients were treated using a customized configuration of a commercial clinical ultrasound scanner over a time period of 31.5 min following standard chemotherapy treatment with gemcitabine. SonoVue(®) ultrasound contrast agent was injected intravascularly during the treatment with the aim to induce sonoporation. RESULTS: Using the authors' custom acoustic settings, the authors' patients were able to undergo an increased number of treatment cycles; from an average of 9 cycles, to an average of 16 cycles when comparing to a historical control group of 80 patients. In two out of five patients treated, the maximum tumor diameter was temporally decreased to 80 ± 5% and permanently to 70 ± 5% of their original size, while the other patients showed reduced growth. The authors also explain and characterize the settings and acoustic output obtained from a commercial clinical scanner used for combined ultrasound microbubble and chemotherapy treatment. CONCLUSIONS: It is possible to combine ultrasound, microbubbles, and chemotherapy in a clinical setting using commercially available clinical ultrasound scanners to increase the number of treatment cycles, prolonging the quality of life in patients with pancreatic adenocarcinoma compared to chemotherapy alone.


Assuntos
Desoxicitidina/análogos & derivados , Microbolhas/uso terapêutico , Neoplasias Pancreáticas/terapia , Terapia por Ultrassom , Idoso , Terapia Combinada , Desoxicitidina/uso terapêutico , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/tratamento farmacológico , Gencitabina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA