1.
Retina ; 44(4): 610-617, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37973044

RESUMO

PURPOSE: To measure the tangential retinal displacement and vision before and after macular pucker surgery and study if pars plana vitrectomy with epiretinal membrane peeling allows the reconstitution of previous anatomy or else it results in a different configuration. METHODS: Retrospective series of patients undergoing pars plana vitrectomy for epiretinal membrane, with >6-month follow-up before and after surgery, complete with best-corrected visual acuity, optical coherence tomography, M-Charts, and infrared retinography. Tangential retinal displacement between earliest visit (T E ), time of surgery (T 0 ), and latest available visit (T L ) of the examined retina, concentric circles at 0.5, 1.5, and 4.5 mm radii, and the central horizontal and vertical meridians were measured. Tangential displacement was calculated as the optical flow of consecutive infrared photographs. RESULTS: The study comprised 32 patients: 15 men and 17 women. Average preoperative and postoperative follow-up were 23.4 ± 27.9 months and 19.2 ± 11.8 months, respectively. Best-corrected visual acuity reduced before surgery (0.69 ± 0.16 Snellen to 0.46 ± 0.17; P < 0.001) and increased after (0.866 ± 0.16 Snellen; P < 0.001). Horizontal and vertical metamorphopsia increased between before surgery but only horizontal metamorphopsia significantly reduced after. Average tangential displacement before surgery was 35.6 ± 29.9 µ m versus 56.6 ± 41.3 µ m after ( P = 0.023). Preoperative and postoperative displacement within the fovea was less than over the entire area ( P < 0.001). CONCLUSION: Retinal tangential displacement between diagnosis and surgery (T E - T 0 ) is less than the displacement occurring after surgery (T 0 - T L ). Postoperative displacement does not represent the restoration of the anatomy existing before the disease ensued but rather the resulting equilibrium of newly deployed forces.


Assuntos
Membrana Epirretiniana , Masculino , Humanos , Feminino , Membrana Epirretiniana/cirurgia , Estudos Retrospectivos , Complicações Pós-Operatórias/cirurgia , Retina , Tomografia de Coerência Óptica/métodos , Transtornos da Visão/cirurgia , Vitrectomia/métodos
2.
Retina ; 44(1): 102-110, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37695945

RESUMO

PURPOSE: To study visual function, retinal layer thickness changes, and tangential displacement after pars plana vitrectomy for epiretinal membrane. METHODS: Retrospective series of patients undergoing pars plana vitrectomy for epiretinal membrane, with 6-month follow-up including best-corrected visual acuity, optical coherence tomography, M-charts, epiretinal membrane grading, and infrared fundus photograph at time 0 (T0, preop) at months 1 (T1), 3 (T3), and 6 (T6) postop (±1 week). Retinal layer thickness and tangential ( en face ) retinal displacement between successive times for the entire retinal surface and the central horizontal and vertical meridian were also measured. En face displacement was calculated as optical flow of consecutive images. RESULTS: Average best-corrected visual acuity improved from 0.28 ± 0.08 logarithm of Minimum Angle of Resolution at T0 to 0.16 ± 0.25 at T6 ( P = 0.05), best-corrected visual acuity improvement correlated with best corrected visual acuity (BCVA) at T0 ( P < 0.001). Vertical metamorphopsia decreased from 1.33° ± 0.70° at T0 to 0.82° ± 0.69° at T6 ( P < 0.05). Foveal thickness reduced from 453 ± 53 µ m at T0 to 359 ± 31 µ m at T6 ( P < 0.05) and reduction correlated with best-corrected visual acuity improvement ( P < 0.05). Foveal layers decreased ( P < 0.05) in all cases. The mean en face deformation was 155.82 ± 50.17 µ m and mostly occurred in the first month: T0-T1 displacement was 83.59 ± 30.28 µ m, T1-T3 was 36.28 ± 14.45 µ m, while T3-T6 was 39.11 ± 22.79 µ m ( P < 0.001) on average. Perifoveal and parafoveal deformation correlated with optical coherence tomography foveal thickness reduction at all time intervals (1, 3, and 6 months: P < 0.01). CONCLUSION: Epiretinal membrane peeling affects all retinal layer thickness and results in new force balance across the entire retina and tangential displacement. Both en face and in-depth changes correlate with visual function.


Assuntos
Membrana Epirretiniana , Humanos , Membrana Epirretiniana/cirurgia , Estudos Retrospectivos , Acuidade Visual , Retina , Fóvea Central , Tomografia de Coerência Óptica/métodos , Vitrectomia/métodos
3.
Retina ; 44(8): 1329-1336, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39047126

RESUMO

PURPOSE: To measure the coronal and sagittal retinal displacement before and after surgery for epiretinal membranes in InfraRed horizontal foveal sections and optical coherence tomography scans and describe displacement tridimensionality, vision loss, and metamorphopsia. METHODS: Retrospective series with greater than 6-month average follow-up before and after surgery. The record included best-corrected visual acuity, optical coherence tomography, M-charts, and InfraRed retinography. Overall, pre- and postoperative coronal and sagittal retinal displacement across the entire field, concentric circles at 0.5-, 1.5-, and 4.5-mm radii, and the central horizontal and vertical meridian were calculated as the optical flow of consecutive images. RESULTS: This study comprised 10 patients (4 men, 6 women), with 22.7 ± 25.2 months follow-up before surgery and 16.2 ± 7.3 months after. Best-corrected visual acuity reduced before surgery (0.15 ± 0.67 logarithm of minimum angle of resolution to 0.38 ± 0.85 logarithm of minimum angle of resolution; P < 0.05) and increased afterward (0.086 ± 0.61 logarithm of minimum angle of resolution; P = 0.003). Preoperative coronal displacement was 30.1 ± 29.1 µm versus 67.0 ± 23.4 µm after (P = 0.002). Sagittal retinal displacement was 140.9 ± 84.6 µm before surgery, 339.7 ± 172.5 µm after (P = 0.017), and 357.6 ± 320.8 µm across the entire follow-up. Preoperative best-corrected visual acuity decreases correlated with the foveal coronal displacement. Vertical metamorphopsia correlated with the average coronal displacement within a 4.5-mm radius. Pre- and postoperative sagittal displacement correlated with horizontal metamorphopsia (P = 0.006 and P = 0.026). Postoperative sagittal displacement correlated with postoperative best-corrected visual acuity (P = 0.026) and foveal thickness (P = 0.009). CONCLUSION: This study confirms that postoperative displacement is greater than preoperative and that sagittal displacement is greater than coronal and correlates with best-corrected visual acuity and metamorphopsia changes.


Assuntos
Membrana Epirretiniana , Tomografia de Coerência Óptica , Acuidade Visual , Vitrectomia , Humanos , Masculino , Feminino , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Acuidade Visual/fisiologia , Idoso , Vitrectomia/métodos , Pessoa de Meia-Idade , Membrana Epirretiniana/cirurgia , Membrana Epirretiniana/fisiopatologia , Membrana Epirretiniana/diagnóstico , Seguimentos , Imageamento Tridimensional , Idoso de 80 Anos ou mais , Período Pós-Operatório
4.
Retina ; 43(6): 955-963, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36800522

RESUMO

PURPOSE: To calculate the retinal surface alternatively in contact with gas and aqueous because of fluid sloshing during daily activities such as ocular saccade, turning the head, standing up, and being a passenger of a braking car. METHODS: Fluid dynamics of aqueous and gas tamponade was reproduced using computational methods using the OpenFOAM open-source library. The double-fluid dynamics was simulated by the volume of fluid method and setting the contact angle at the aqueous-gas-retina interface. RESULTS: Sloshing increased the retinal surface in contact with aqueous by 13% to 16% regardless of fill rate and standing up determined the largest area of wet retina, followed by car braking, head rotation, and ocular saccade ( P < 0.001). All activities except the ocular saccade determined a significant increase in the surface of retina in contact with the aqueous ( P < 0.005). Car braking induced the highest shear stress (6.06 Pa); standing up determined the highest specific impulse and saccade the lowest. CONCLUSION: Daily activities instantaneously reduce the amount of retina consistently in contact with gas tamponade and increase shear stress giving aqueous a potential access to the subretinal space regardless of patients' compliance.


Assuntos
Descolamento Retiniano , Vitrectomia , Humanos , Vitrectomia/métodos , Descolamento Retiniano/cirurgia , Hidrodinâmica , Retina/cirurgia
5.
Exp Eye Res ; 175: 159-165, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29935948

RESUMO

Purpose of present study is to evaluate whether the Pre-Macular Bursa (PMB) modifies Wall Shear Stress (WSS) at the retinal surface during saccadic movements. We created a mathematical model consisting of 25,000 grid cells and simulated a horizontal saccade spanning 50° in 0.17s, both in absence and in presence of the PMB. Wall Shear Stress SS was computed throughout the retinal surface and the posterior pole was divided into 3 Zones comprising 400 nodes each: Zone 1 (radius 3.5 mm; 0°-17°) corresponding to the PMB area; Zone 2 (concentric annular area 5 mm in radius; 22°) and Zone 3 (concentric annular area 5.5 mm; 28°). The PMB reduced WSS significantly at the macula and increased it in the immediate surroundings. Average WSS in Zone 1 was 1.53 ±â€¯1.01 (max 4.23 Pa) with PMB Vs 6.94 ±â€¯9.23 (max 35.83 Pa) without. Zone 2 WSS was 9.39 ±â€¯10.33 (max 48.36 Pa) with PMB Vs 6.95 ±â€¯9.40 (max 38.60 Pa) without Zone 3 WSS was 8.41 ±â€¯10.03 (max 43.16 Pa) with PMB Vs 6.88 ±â€¯9.42 (max 39.43 Pa) without (p < 0.001 in all cases). The PMB significantly reduces WSS over the retinal surface underlying the bursa region; conversely, WSS slightly increases it in the immediate neighboring areas.


Assuntos
Fóvea Central/fisiologia , Hidrodinâmica , Modelos Teóricos , Estresse Mecânico , Corpo Vítreo/fisiologia , Análise de Elementos Finitos , Humanos , Movimentos Sacádicos/fisiologia
6.
Biomed Eng Online ; 16(1): 29, 2017 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-28209171

RESUMO

BACKGROUND: Haemodynamic performance of heart valve prosthesis can be defined as its ability to fully open and completely close during the cardiac cycle, neither overloading heart work nor damaging blood particles when passing through the valve. In this perspective, global and local flow parameters, valve dynamics and blood damage safety of the prosthesis, as well as their mutual interactions, have all to be accounted for when assessing the device functionality. Even though all these issues have been and continue to be widely investigated, they are not usually studied through an integrated approach yet, i.e. by analyzing them simultaneously and highlighting their connections. RESULTS: An in vitro test campaign of flow through a bileaflet mechanical heart valve (Sorin Slimline 25 mm) was performed in a suitably arranged pulsatile mock loop able to reproduce human systemic pressure and flow curves. The valve was placed in an elastic, transparent, and anatomically accurate model of healthy aorta, and tested under several pulsatile flow conditions. Global and local hydrodynamics measurements and leaflet dynamics were analysed focusing on correlations between flow characteristics and valve motion. The haemolysis index due to the valve was estimated according to a literature power law model and related to hydrodynamic conditions, and a correlation between the spatial distribution of experimental shear stress and pannus/thrombotic deposits on mechanical valves was suggested. As main and general result, this study validates the potential of the integrated strategy for performance assessment of any prosthetic valve thanks to its capability of highlighting the complex interaction between the different physical mechanisms that govern transvalvular haemodynamics. CONCLUSIONS: We have defined an in vitro procedure for a comprehensive analysis of aortic valve prosthesis performance; the rationale for this study was the belief that a proper and overall characterization of the device should be based on the simultaneous measurement of all different quantities of interest for haemodynamic performance and the analysis of their mutual interactions.


Assuntos
Valva Aórtica/fisiologia , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Aorta/metabolismo , Velocidade do Fluxo Sanguíneo/fisiologia , Hemólise , Humanos , Modelos Anatômicos , Desenho de Prótese , Fluxo Pulsátil/fisiologia , Estresse Mecânico
7.
Graefes Arch Clin Exp Ophthalmol ; 255(12): 2325-2330, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28887584

RESUMO

PURPOSE: To study the efficacy of a novel device intended to control infusion pressure based on mean ocular perfusion pressure (MOPP) during pars plana vitrectomy (PPV). METHODS: An arm blood pressure cuff connected to a vitrectomy machine calculated mean arterial pressure (MAP), while a pressure sensor close to the infusion trocar measured intraocular pressure (IOP). MOPP was calculated in real time in 36 consecutive patients undergoing PPV, who were divided into two groups. The device lowered IOP every time that calculated MOPP fell below 30 mmHg in the Control ON group (18 patients), while no action was taken in the Control OFF group (18 patients). RESULTS: Baseline IOP and blood pressure were similar between groups. The Control ON group had significantly lower average intraoperative IOP (30.5 ± 2.1 vs. 35.9 ± 6.9 mmHg; p = 0.002) and higher MOPP (56.4 ± 5.9 vs. 49.7 ± 6.1 mmHg) than the Control OFF group. The Control ON group also spent less time at MOPP < 10 mmHg and < 30 mmHg: 0 vs. 3.40 ± 2.38 min (p < 0.001) and 9.91 ± 7.15 vs. 16.13 ± 8.12 min (p = 0.02), respectively. CONCLUSIONS: The MOPP control device effectively maintained lower IOP and higher MOPP throughout surgery. It also helped avoid dangerous IOP peaks and MOPP dips, allowing patients to spend less time at MOPP of < 10 and < 30 mmHg.


Assuntos
Pressão Sanguínea/fisiologia , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Monitorização Intraoperatória/instrumentação , Vitrectomia , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Perfusão , Reprodutibilidade dos Testes
8.
Retina ; 36(7): 1252-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26655617

RESUMO

PURPOSE: To characterize the fluidics of axial rotating vitreous cutter probe (RT) compared with the standard guillotine (regular blade), when tested in Balanced Salt Solution (Alcon Laboratories, Forth Worth, TX). METHODS: RT and regular blade (RB) cutter probes connected to the same vitrectomy console used a peristaltic pump. The authors measured instantaneous flow through aspiration tubing proximal to the handpiece, fluid velocity, and acceleration at the port by means of particle image velocimetry. RESULTS: Average flow at aspiration tubing of RT and RB did not vary significantly. Regular blade probes produced higher instantaneous flow fluctuation than RT at any considered cut rate (RB 1,600 6.4 ± 5.3 mL/minute; RB 3,000 11.8 ± 6.3 mL/minute; RT 1,600 0.9 ± 0.7 mL/minute, and RT 3,000 1.8 ± 0.8 mL/minute, respectively. P < 0.001 in all cases). Regular blade also yield significantly higher fluid velocity at cutter port compared with RT (RB 1,600 85.8 ± 70.1 mm/second; RB 3,000 81.6 ± 66.4 mm/second; RT 1,600 71.9 ± 40.3 mm/second; and RT 3,000 32.9 ± 20.8 mm/second. P < 0.001 in all cases). Fluid acceleration at the cutter port was higher when the RB was used (RB 1,600 26.85 ± 30.18 mm/second; RB 3,000 33.76 ± 34.09 mm/second; RT 1,600 24.01 ± 21.94 mm/second; and RT 3,000 16.62 ± 17.87 mm/second. P < 0.001 in all cases). CONCLUSION: RT blade design causes less instantaneous flow fluctuation within the aspiration tubing, and also lower fluid velocity and lower acceleration at the cutter port. Fluidics suggests a safer cutting action and a reduced risk of retinal incarceration.


Assuntos
Hidrodinâmica , Vitrectomia/instrumentação , Corpo Vítreo/cirurgia , Acetatos , Combinação de Medicamentos , Humanos , Minerais , Reologia , Cloreto de Sódio
9.
Retina ; 34(9): 1896-904, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24871998

RESUMO

PURPOSE: To assess the efficacy of novel vitreous cutter blades compared with the regular guillotine by means of particle image velocimetry. Tested blades included a regular blade (RB) and newer designs where a circular (hole blade [HB]) or a slit aperture (slit blade [SB]) had been opened proximal to the cutting edge. METHODS: Twenty-three-gauge probes were immersed in BSS or egg albumen, and high-speed video (1,000 frames per second) was recorded. Duty cycle, flow rate, and acceleration generated by Venturi and peristaltic pumps were measured under cutter settings simulating "low-speed" vitrectomy (1600 cuts per minute, 200 mmHg vacuum) and "high speed" vitrectomy (3000 cuts per minute, 300 mmHg vacuum). RESULTS: The SB and HB had a significantly more favorable duty cycle than that of the RB (P < 0.01) and higher BSS flow rate regardless of the aspiration. The SB flow rate in albumen was significantly higher than that of the HB and RB only over 1,000 cuts per minute using a peristaltic pump and at any cut rate with Venturi pump (P < 0.001). The SB also yielded the lowest fluid acceleration than both the HB and SB (P < 0.001 in all cases). CONCLUSION: The HB and SB proved to be significantly more efficient than the RB, with better duty cycle and higher flow rate. The SB generated significantly less fluid acceleration than any other tested blade, regardless of the fluid viscosity and pump technology. The SB design is significantly more efficient and possibly safer than both HB and RB.


Assuntos
Hidrodinâmica , Vitrectomia/instrumentação , Corpo Vítreo/cirurgia , Acetatos , Combinação de Medicamentos , Desenho de Equipamento , Humanos , Minerais , Ovalbumina , Cloreto de Sódio , Gravação em Vídeo
10.
Retina ; 34(3): 558-67, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24013257

RESUMO

PURPOSE: To characterize the fluidics of vitreous cutter port in response to aspiration and blade motion using particle image velocimetry techniques. Diverse surgical scenarios and fluid characteristics were replicated. METHODS: The 23-gauge vitreous cutters were immersed in seeded Balanced Salt Solution (BSS) (Alcon, Forth Worth, TX) or egg albumen, and high-speed video was recorded. Fluid velocity, kinetic energy (KE), and acceleration generated by Venturi and peristaltic pumps were measured in aspiration only (200 and 300 mmHg), low-speed vitrectomy (1,600 cuts per minute; 200 mmHg vacuum), and high-speed vitrectomy (3,000 cuts per minute; 300 mmHg vacuum) modes. RESULTS: The Venturi pump generated significantly higher KE than peristaltic pump in BSS (P < 0.0001 for each pair), and aspiration only yielded significantly higher KE. Cutting activation generated significant acceleration (P < 0.001), and the peristaltic pump produced higher positive and negative acceleration peaks (P < 0.001) than the Venturi pump. In egg albumen, the peristaltic pump generated significantly more KE than the Venturi pump (P < 0.001) and perturbed a much wider area. Acceleration was higher for the peristaltic pump in low-speed mode (P < 0.001), whereas in high-speed modality, the Venturi pump produced the highest acceleration peaks (P < 0.001). CONCLUSION: Pump type and blade motion largely influence velocity, KE, and acceleration. In BSS, the Venturi pump induces higher KE and acceleration, although perturbing fluid less diffusely. In egg albumen, the peristaltic pump perturbed a much wider area and induced a higher KE and acceleration than the Venturi pump, even more so at lower cut rates. As a conclusion, particle image velocimetry allowed precise characterization of fluid velocity in response to cutter activation, suggesting a pragmatic approach to surgical scenarios.


Assuntos
Vitrectomia/instrumentação , Albuminas , Cinética , Microcirurgia/métodos , Modelos Biológicos , Cloreto de Sódio , Sucção , Gravação em Vídeo , Vitrectomia/métodos
11.
Transl Vis Sci Technol ; 12(4): 21, 2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-37070937

RESUMO

Purpose: To compare the efficacy of two surgical techniques used to remove silicone oil (SiO) emulsion tamponade after pars plana vitrectomy: triple air-fluid exchange (AFX) and balanced salt solution lavage (BSSL). Methods: X-ray photoemission spectroscopy measured silicon content of the dry residue of fluid samples taken during AFX and BSSL. Ten patients underwent AFX and five BSSL. Three fluid samples were taken per patient, and the dry residue of 10 drops per sample were analyzed. A fluid sample from a patient who never received SiO tamponade was also analyzed to set a "blank" reference sample. Results: Patients' demographics showed no significant difference. Sample 1 of the two groups contained comparable silicon content while samples 2 and 3 of the AFX group contained significantly more silicon than that of the BSSL group (15.0 ± 0.1 and 12.0 ± 0.9 for the AFX group vs. 10.7 ± 1.4 and 5.2 ± 0.6 for the BSSL group, respectively; P < 0.05). The cumulative amount of silicon in the three successive samples was also significantly higher for the AFX group (42.3 ± 1.6 vs. 32 ± 2; P < 0.0001). The average silicon content ratio of consecutive samples was significantly higher for the AFX group compared to the BSSL group (0.90 ± 0.01 vs. 0.58 ± 0.06; P = 0.006). Conclusions: Triple AFX removed more silicon than triple lavage. The eye wall actively interacts with silicon emulsion retaining silicon content rather than behaving as a neutral container. Translational Relevance: Triple air-fluid exchange removed more silicon than BSS lavage. Neither technique behaved as a well-mixed box dilution, suggesting the eye walls actively retain emulsion and a dynamic equilibrium is established between silicon dispersion and the eye wall surface.


Assuntos
Silício , Óleos de Silicone , Humanos , Emulsões , Espectroscopia Fotoeletrônica , Raios X
12.
Transl Vis Sci Technol ; 12(4): 6, 2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-37017957

RESUMO

Purpose: To establish a correlation between phacoemulsification tip normalized driving voltage (NDV) and crystalline lens hardness and use it as an objective measure of lens hardness. The study used a phaco tip equipped with previously validated elongation control adjusting the driving voltage (DV) to produce invariant elongation regardless of resistance. Methods: The laboratory study measured the mean and maximum DV of the phaco tip immersed in glycerol-balanced salt solution and correlated the DV with the kinematic viscosity at 25, 50, and 75 µm tip elongation. The NDV were obtained by dividing the DV in glycerol by the DV in the balanced salt solution. The clinical arm of the study recorded DV of 20 consecutive cataract surgeries. The correlation of mean and maximum NDV to Lens Opacities Classification System (LOCS) III classification, patient's age and effective phaco time were evaluated. Results: The mean and maximum NDV correlated with the kinematic viscosity of the glycerol solution (P < 0.001 in all cases). Mean and maximum NDV during cataract surgery correlated with patients' age, effective phaco time, LOCS III nuclear color, and nuclear opalescence (P < 0.001 in all cases). Conclusions: When a feedback algorithm is running, DV variation strictly correlates with encountered resistance in glycerol solutions and real-life surgery. NDV significantly correlates with the LOCS classification. Future developments might include sensing tips that react to lens hardness in real time. Translational Relevance: The study correlates for the first time phaco tip DV and crystalline lens mechanical properties, establishing an objective and reliable measure of lens hardness. This may lead to smart phaco tips reacting to cataract hardness change in real time and sparing ultrasound dispersion.


Assuntos
Catarata , Cristalino , Facoemulsificação , Humanos , Glicerol , Dureza
13.
Exp Eye Res ; 99: 98-104, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22516112

RESUMO

Knowledge of vitreous motion in response to saccades is a prerequisite for understanding vitreous rheology. Purpose of present paper is to introduce Ultrasound Image Velocimetry of the human eye, measure scleral and vitreous velocity fields and test the reproducibility of the proposed technique. Twelve patients with varying diagnosis underwent Ocular Dynamic Ultrasound; scleral angular velocity (V(S)) was measured by 2 different operators and reproducibility calculated. Squared velocity of the vitreous (E), which is representative of kinetic energy per unit mass, was computed from velocity. The time evolution of the energy of the vitreous was described by its spatial average (E(S)), whereas spatial distribution was described by its time average (E(T)). Peak and average E(S), the ratio K(p) of the peak of the spatially averaged kinetic energy per unit mass to the maximum squared scleral angular velocity, vitreous motion onset time (T(O)) and vitreous motion decay time (T(D)) were also defined. Inter-operator reproducibility coefficient was 0.043 and correlation between operators was significant. V(S), peak and average E(S), K(p) ratio and T(D) differed among patients but not among operators. V(S) correlated with E(S) and T(D). E(S) and T(D) but not V(S), were significantly different in patients with Posterior Vitreous Detachment. Patients with retinal detachment showed significantly higher V(S) and E(S). K(p) was inversely correlated to age and refraction. Measures proved accurate and reproducible. E is related to V(S), retinal traction and mechanical stimulation. Identified variables varied with age, refraction pathologic conditions.


Assuntos
Hidrodinâmica , Reologia/métodos , Corpo Vítreo/química , Corpo Vítreo/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimentos Sacádicos/fisiologia , Esclera/diagnóstico por imagem , Esclera/fisiologia , Fatores de Tempo , Ultrassonografia , Substâncias Viscoelásticas
14.
Transl Vis Sci Technol ; 11(6): 1, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35648638

RESUMO

Purpose: To investigate the behavior of silicone oil (SiO) at a steady equilibrium and during saccades in pseudophakic highly myopic eyes with posterior staphyloma with and without an encircling band and compare it to behavior in emmetropic eyes. The SiO-retina contact area and shear stress were calculated by computational fluid dynamics. Methods: A numerical model of an emmetropic eye and a myopic eye with and without scleral band underwent a saccade of 50°/0.137 s. The vitreous chamber surface was divided into superior and inferior 180° sectors: lens, pre-equator, post-equator, and macula. SiO-retina contact was evaluated as a function of fill percentages between 80% and 90% for standing, 45° upward tilt, and supine patients. Maximum and average shear stress were calculated. Results: Overall, SiO-retina contact ranged between 40% and 83%; fill percentage varied between 80% and 95%. Neither the encircling scleral band nor the staphyloma significantly affected the SiO-retina contact area, although the presence of a scleral band proved disadvantageous when gazing 45° upward. The inferior retina-SiO contact remained below 40% despite 95% SiO fill. The SS significantly increased at the scleral band indentation and decreased elsewhere. The staphyloma greatly reduced shear stress at the macula. Conclusions: The presence of a myopic staphyloma reduces shear stress at the macula but does not alter SiO-retina contact significantly. The apposition of a 360° scleral band may reduce SiO-retina contact at least in some postures and increases the SS at the indentation. Translational Relevance: Assessing SiO-retina contact when vitreous chamber geometry changes according to pathologic or iatrogenic modifications allows accurate prediction of real-life tamponade behavior and helps explain surgical outcomes.


Assuntos
Miopia , Descolamento Retiniano , Doenças da Esclera , Humanos , Hidrodinâmica , Retina , Descolamento Retiniano/patologia , Descolamento Retiniano/cirurgia , Doenças da Esclera/patologia , Óleos de Silicone
15.
Transl Vis Sci Technol ; 11(3): 29, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-35333285

RESUMO

Purpose: To study the dimensions and distribution of human vitreous collagen type II fragments collected after vitrectomy performed at varying cut rates and to evaluate if increasing the cut rate produces smaller collagen fragments, thus reducing retinal traction and/or viscosity. Methods: Fluid was collected during core vitrectomies performed for macular surgery at cut rates from 1000 to 16,000 cuts per minute (CPM) and immediately refrigerated. Protein fractions were separated by molecular weight (MW; >100 kDa, 50-100 kDa, 50-30 kDa, 30-10 kDa, and <10 kDa) through centrifugal filters. The Human Collagen II ELISA Kit colorimetric assay was then used to measure the COL2A1 in unfiltered and filtered samples. Results: Vitreous samples collected after vitrectomy performed at 16,000 CPM contained a higher concentration of protein with MW over 100 kDa than at any other cutting frequency (P < 0.01). No significant differences were found in fractions collected with a MW between 50 and 100 kDa. Collagen type II fragments over 100 kDa were significantly more represented than smaller fragments at each cut rate. The proportion of smaller (50-100 kDa) collagen fragments compared with those over 100 kDa was higher at 2000 CPM than at higher cut rates. Conclusions: Vitreous samples collected at different cut rates do not contain a significantly different proportion of collagen type II fragments of the tested MW. The extreme variability of vitreous flow through the cutter port may explain the uncertain predictability of collagen fragment MWs. Translational Relevance: Increasing the cut rate does not produce vitreous fragments of proportionally smaller dimension. It is necessary to achieve an invariant instantaneous flow through the cutter port in order to decrease retinal traction during vitrectomy.


Assuntos
Vitrectomia , Corpo Vítreo , Colágeno/metabolismo , Colágeno Tipo II/metabolismo , Humanos , Viscosidade , Vitrectomia/métodos , Corpo Vítreo/metabolismo , Corpo Vítreo/cirurgia
16.
Transl Vis Sci Technol ; 10(8): 22, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34313726

RESUMO

Purpose: To investigate the behavior of silicone oil (SiO) at the steady equilibrium and during saccades and calculate SiO-retina contact, shear stress (SS), and shear rate (SR). Methods: A 24 mm phakic eye mesh model underwent 50°/0.137s saccade. The vitreous chamber compartment was divided into superior and inferior 180° sectors: lens, pre-equator, postequator, and macula. SiO-retina contact was evaluated as a function of fill percentages between 80% and 90% for a standing patient, 45° upward gaze, and supine. SS and SR for 1000 mPa-s (SiO1000) and 5000 mPa-s (SiO5000) silicon oil were calculated. Results: SiO fill between 80% to 90% allowed 55% to 78% retinal contact. The superior retina always kept better contact with SiO, regardless of the fill percentage (P < 0.01). SiO interface thoroughly contacted the macula only in standing position. SS followed a bimodal behavior and was always significantly higher for SiO5000 compared to SiO1000 (P < 0.01) throughout the saccade. The macula suffered the highest mean SS in standing position, while throughout the saccade the average SS was maximum at the SiO-aqueous interface. SR was significantly higher for SiO1000 compared to SiO5000 (P < 0.001). Conclusions: SS on the retinal surface may instantaneously exceed reported retinal adhesiveness values especially at the SiO-aqueous interface and possibly favor redetachment. Despite 90% SiO fill the inferior retina remains extremely difficult to tamponade. Translational Relevance: Accurate assessment of retina-tamponade interaction may explain recurrent inferior retinal redetachment, silicone oil emulsification, and help to develop better vitreous substitutes.


Assuntos
Descolamento Retiniano , Óleos de Silicone , Humanos , Hidrodinâmica , Retina , Descolamento Retiniano/cirurgia , Vitrectomia
17.
Transl Vis Sci Technol ; 9(3): 7, 2020 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-32704427

RESUMO

Purpose: To assess whether the use of a patented, novel feedback device intended to accurately control phacoemulsification tip elongation is effective under varying machine settings and material resistance. Methods: Sculpt mode phaco (550-mm Hg Venturi pump; elongations, 35 and 70 µm) and quadrant settings (550-mm Hg Venturi pump; elongations, 15, 30, and 60 µm) were used in agar gel of incremental density (1%, 2%, 3%, and 6% in demineralized water). Dispersed lens fragments were also simulated with 6% agar gel spherules (2-5 mm in diameter; 550-mm Hg vacuum, and 60-µm elongation). Actual phaco tip elongation was measured on voltage readings from the piezoelectric crystals and compared to nominal elongation with feedback control off and on. Results: Mismatch between nominal and actual elongation when feedback control was off in sculpt mode varied between -13.51 µm and -23.07 µm of nominal elongation; in quadrant mode, mismatch varied between -2.79 µm and -20.41 µm. When the feedback control system was switched on, mismatch varied between -0.02 µm and +0.43 µm (P < 0.001 for all matchings). When the feedback system was off, the elongation mismatch among the 1%, 3%, and 6% agar was also statistically significant (P < 0.001). Elongation was 44.72 ± 4.16 µm with feedback control off and 60.02 ± 1.63 µm with it on (nominal elongation 60 µm; P < 0.001) when emulsifying agar 6% gel fragments. Dispersion of elongation data was also significantly wider when feedback control was turned off. Conclusions: A novel feedback control system effectively controls elongation accuracy regardless of the resistance offered by incremental agar gel concentrations. Translational Relevance: Implementing feedback control in phaco handpieces dramatically improves surgical accuracy. The translational value of this research relies on its immediate applicability to routine cataract surgery, resulting in a more appropriate use of ultrasound energy.


Assuntos
Extração de Catarata , Cristalino , Facoemulsificação , Terapia por Ultrassom , Vácuo
19.
Ann Biomed Eng ; 47(8): 1799-1814, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31011916

RESUMO

Left ventricle assist devices (VADs) aid the heart pumping blood into the systemic circulation and grant the required cardiac output (CO) when the heart itself cannot provide it. However, it is unclear how effective these devices are at restoring not only physiological CO values but also normal intraventricular hemodynamics. In this work, the modified hemodynamics due to a VAD implantation is studied in vitro using an elastic ventricle made of silicone, which is incorporated into a pulse-duplicator setup prescribing a realistic pulsatile flow. Thereafter, a continuous axial pump is connected at the ventricle apex to mimic a VAD and its effect on the ventricular hemodynamics is investigated as a function of the pump flow suction. Using particle image velocimetry (PIV), we observe that the continuous pump flow effectively provides unloading on the ventricle and yields an increased CO. Conversely, the continuous blood suction from the ventricle apex deeply alters the hemodynamics and, in addition, the VAD obstruction in the ventricle behaves as a bluff body that affects the vorticity distribution in the LV thus creating a stagnant region at the ventricle apex. This phenomenon is rationalized by measuring in a modified set-up the benefits on the hemodynamics of a flush-mounted device. Additionally, the suction operated by the VAD reduces the ventricular pressure and yields an increase in the swirling motion around the ventricle axis, in a similar fashion as the bath-tub vortex effect, thus further modifying the intraventricular hemodynamics with respect to healthy conditions.


Assuntos
Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Hidrodinâmica , Modelos Cardiovasculares , Função Ventricular , Débito Cardíaco , Humanos , Fluxo Pulsátil
20.
Transl Vis Sci Technol ; 5(4): 1, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27441099

RESUMO

PURPOSE: To measure the hydraulic resistance (HR) of vitreous cutters equipped with a Regular guillotine Blade (RB) or double edge blade (DEB) at cut rates comprised between 0 and 12,000 cuts per minute (CPM) and compare it with vitreous fragment size. This was an in vitro experimental study; in vivo HR measure and vitreous sampling. METHODS: HR, defined as aspiration pressure/flow rate, was measured in balanced salt solution (BSS; Alcon, Fort Worth, TX) (in vitro) and during pars plana vitrectomy of 20 consecutive patients aged 18 to 65, undergoing macular surgery. HR was recorded at increasing cut rates (500-6000 CPM for the RB and 500-12,000 CPM for the DEB; 5 mL/min flow). Vitreous samples were withdrawn and analyzed with Western and collagen type II and IX immunostaining to evaluate protein size. The main outcome measures were hydraulic resistance (mm Hg/ml/min [±SD]) and optic density for Western blot and immunostaining. RESULTS: RB and DEB showed identical HR in BSS between 0 and 3000 CPM. Above 3000 CPM, RB HR steadily increased, and was significantly higher than DEB HR. Vitreous HR was also similar for the two blades between 0 and 1500 CPM. Above 1500 CPM, RB offered a significantly higher resistance. Western blot and immunostaining of vitreous samples did not yield a significant difference in size, regardless of blade type and cut rate. CONCLUSIONS: DEB is more efficient, offering a lower HR than RB over 1500 CPM in human vitreous. There is no viscosity reduction as a function of cut-rate between 1500 and 12,000 CPM, as HR does not vary. TRANSLATIONAL RELEVANCE: Future vitreous cutters will benefit of a DEB; optimal cut rate needs to be defined, and the simple increase of cut rate does not provide benefits after a certain limit to be assessed.