Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Can Assoc Radiol J ; : 8465371241252793, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795028

RESUMO

Purpose: To assess and compare intrareader and interreader reproducibility of magnetic resonance imaging (MRI) diagnosis of female genital anomalies (FGAs) using the American Society for Reproductive Medicine-Mullerian anomalies classification 2021 (ASRM-MAC 2021) and European Society of Human Reproduction and Embryology-European Society for Gynecological Endoscopy (ESHRE-ESGE) 2016 classification. Methods: In this retrospective study, we searched our electronic MRI database from April 2021 to September 2023, selecting MRI studies with FGAs. Seventy-six consecutive studies were included and reviewed by 4 independent radiologists using both classifications. Studies were re-evaluated after 1 month. Reproducibility was assessed using kappa (κ) scores with 95% confidence intervals (CI). Results: Intrareader agreement for MRI diagnosis of FGAs was substantial to excellent, with κ scores ranging from 0.684 (95% CI, 0.534-0.834) to 0.985 (95% CI, 0.963-1.01) using the ASRM-MAC 2021 and from 0.743 (95% CI, 0.621-0.865) to 0.846 (95% CI, 0.719-0.973) using the ESHRE-ESGE 2016 classification. Pairwise interreader agreement was higher with the ASRM-MAC 2021, ranging from moderate (κ = 0.491; 95% CI, 0.341-0.642) to substantial (κ = 0.709; 95% CI, 0.597-0.821), compared to the ESHRE-ESGE 2016 classification, with weak (κ = 0.080; 95% CI, 0.068-0.228) to moderate (κ = 0.511; 95% CI, 0.344-0.678) agreement. Overall interreader agreement was moderate for both classifications (κ = 0.599; 95% CI, 0.562-0.638 for ASRM-MAC 2021 and κ = 0.429; 95% CI, 0.396-0.463 for ESHRE-ESGE 2016 classification), but with significant differences (non-overlapping CIs). Conclusion: The intrareader reproducibility was high for both classifications, whereas the interreader reproducibility was higher using the ASRM-MAC 2021, highlighting the impact of classification criteria on the reproducibility of MRI diagnosis of FGAs.

2.
Eur Radiol ; 33(2): 1286-1296, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35962816

RESUMO

OBJECTIVE: To assess the diagnostic accuracy and agreement of CT and MRI in terms of the Bosniak classification version 2019 (BCv2019). MATERIALS AND METHODS: A prospective multi-institutional study enrolled 63 patients with 67 complicated cystic renal masses (CRMs) discovered during ultrasound examination. All patients underwent CT and MRI scans and histopathology. Three radiologists independently assessed CRMs using BCv2019 and assigned Bosniak class to each CRM using CT and MRI. The final analysis included 60 histopathologically confirmed CRMs (41 were malignant and 19 were benign). RESULTS: Discordance between CT and MRI findings was noticed in 50% (30/60) CRMs when data were analyzed in terms of the Bosniak classes. Of these, 16 (53.3%) were malignant. Based on consensus reviewing, there was no difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT (87.8%; 95% CI = 73.8-95.9% versus 75.6%; 95% CI = 59.7-87.6%; p = 0.09, 84.2%; 95% CI = 60.4-96.6% versus 78.9%; 95% CI = 54.4-93.9%; p = 0.5, and 86.7%; 95% CI = 64.0-86.6% versus 76.7%; 95% CI = 75.4-94.1%; p = 0.1, respectively). The number and thickness of septa and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. The inter-reader agreement (IRA) was substantial for determining the Bosniak class in CT and MRI (k = 0.66; 95% CI = 0.54-0.76, k = 0.62; 95% CI = 0.50-0.73, respectively). The inter-modality agreement of the BCv219 between CT and MRI was moderate (κ = 0.58). CONCLUSION: In terms of BCv2019, CT and MRI are comparable in the classification of CRMs with no significant difference in diagnostic accuracy and reliability. KEY POINTS: • There is no significant difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT. • The number of septa and their thickness and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. • The inter-reader agreement was substantial for determining the Bosniak class in CT and MRI and the inter-modality agreement of the BCv219 between CT and MRI was moderate.


Assuntos
Doenças Renais Císticas , Neoplasias Renais , Humanos , Doenças Renais Císticas/diagnóstico , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética , Rim/patologia , Estudos Retrospectivos
3.
Eur Radiol ; 28(12): 5356-5367, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29948070

RESUMO

OBJECTIVE: To assess the diagnostic accuracy and illustrate positive findings of contrast-enhanced fluorine-18 fluoro-D-glucose positron emission tomography/computed tomography (18F-FDG PET/CT) image in patients awaiting liver transplantation (LT) with rising alpha-fetoprotein (AFP) after bridge therapy of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This prospective study included 100 patients who were waiting for LT and who previously underwent locoregional therapy (LRT) of HCC. These patients had rising AFP levels on a routine follow-up examination awaiting LT. All patients underwent a contrast-enhanced 18F-FDG PET/CT examination. We calculated for each patient the maximum standardised uptake value (SUVmax) of the tumour and the ratio of the tumoral SUVmax to the normal-liver SUVmax. The diagnostic accuracy and positive contrast-enhanced findings of 18F-FDG PET/CT were established by histopathology and clinical and imaging follow-up as the reference standards. RESULTS: Contrast-enhanced 18F-FDG PET/CT detected tumour relapse in 78 patients (13 patients had intrahepatic lesions, 10 patients had extrahepatic metastases and 55 patients with combined lesions). The sensitivity, specificity and accuracy values of contrast-enhanced 18F-FDG PET/CT examination in the detection of HCC recurrence were 92.8%, 94.1% and 93%, respectively. A significant correlation was found between the AFP level and SUVmax ratio (r = 0.2283; p = 0.0224). The best threshold for 18F-FDG PET positivity was >1.21. CONCLUSION: Contrast-enhanced 18F-FDG PET/CT is a valuable tool for the detection of intrahepatic HCC recurrence or extrahepatic metastasis following rising AFP levels after LRT of HCC, and should be incorporated during routine workup awaiting LT. KEY POINTS: • 18F-FDG PET/CT is a valuable tool for the detection of HCC recurrence • 18 F-FDG PET/CT should be incorporated during routine workup awaiting liver transplantation • Significant correlation was found between AFP level and SUVmax ratio • The best threshold for 18 F-FDG PET positivity was >1.21 • The ideal cut-off value for AFP was >202.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Fluordesoxiglucose F18/farmacologia , Neoplasias Hepáticas/diagnóstico , Transplante de Fígado , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , alfa-Fetoproteínas/metabolismo , Adulto , Idoso , Biomarcadores Tumorais/sangue , Carcinoma Hepatocelular/sangue , Carcinoma Hepatocelular/terapia , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos/farmacologia , Listas de Espera
4.
Acad Radiol ; 31(6): 2536-2549, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38614828

RESUMO

RATIONALE AND OBJECTIVES: Neurological complications associated with coronavirus disease (COVID-19) have been reported in children; however, data on neuroimaging findings remain limited. This study aimed to comprehensively examine neuroimaging patterns of COVID-19 in children and their relationship with clinical outcomes. MATERIALS AND METHODS: This retrospective cross-sectional study involved reviewing the medical records and MRI scans of 95 children who developed new neurological symptoms within 2-4 weeks of clinical and laboratory confirmation of COVID-19. Patients were categorized into four groups based on guidelines approved by the Centers for Disease Control and Prevention (CDC). Initial brain/spinal MRI was performed. Images were reviewed by three blinded radiologists, and the findings were analyzed and categorized based on the observed patterns in the brain and spinal cord. Follow-up MRI was performed and analyzed to track lesion progression. RESULTS: Encephalopathy was the most common neurological symptom (50.5%). The most common initial MRI involvement patterns were non-confluent multifocal hyperintense white matter (WM) lesions (36.8%) and ischemia (18.9%). Most patients who underwent follow-up MRI (n = 56) showed complete resolution (69.9%); however, some patients developed encephalomalacia and myelomalacia (23.2% and 7.1%, respectively). Non-confluent hyperintense WM lesions were associated with good outcomes (45.9%, P = 0.014), whereas ischemia and hemorrhage were associated with poor outcomes (44.1%, P < 0.001). CONCLUSION: This study revealed diverse neuroimaging patterns in pediatric COVID-19 patients. Non-confluent WM lesions were associated with good outcomes, whereas ischemia and hemorrhage were associated with poorer prognoses. Understanding these patterns is crucial for their early detection, accurate diagnosis, and appropriate management.


Assuntos
Encéfalo , COVID-19 , Imageamento por Ressonância Magnética , Neuroimagem , SARS-CoV-2 , Humanos , COVID-19/diagnóstico por imagem , COVID-19/complicações , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Criança , Masculino , Feminino , Pré-Escolar , Neuroimagem/métodos , Estudos Transversais , Lactente , Adolescente , Encéfalo/diagnóstico por imagem , Encefalopatias/diagnóstico por imagem
5.
Abdom Radiol (NY) ; 44(5): 1773-1784, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30603882

RESUMO

PURPOSE: We investigated the added value of diffusion-weighted imaging (DWI)/apparent diffusion coefficient (ADC) in the categorization of small hepatic observation (≤ 20 mm) detected in patients with chronic liver disease in reference to LI-RADS (liver imaging reporting and data system) classification system. METHODS: We prospectively evaluated 165 patients with chronic liver disease with small hepatic observations (≤ 20 mm) which were previously categorized as LI-RADS grade 3-5 on dynamic contrast-enhanced CT (DCE-CT). All patients were submitted to a functional MRI including DCE and DWI. Using LI-RADS v2017, two radiologists independently evaluated the observations and assigned a LI-RADS category to each observation using DCE-MRI alone and combined DCE-MRI and DWI/ADC. In the combined technique, the radiologists assigned a LI-RADS category based on a modified LI-RADS criteria in which restricted diffusion on DWI was considered a major feature of HCC. We evaluated the inter-reader agreement with Kappa statistics and compared the diagnostic performance of the LI-RADS with two imaging techniques by Fisher's exact test using histopathology as the reference standard. RESULTS: Combined technique in LI-RADS yielded better sensitivities (reader 1, 97% [65/67]; reader 2, 95.5% [64/67]) for HCC diagnosis than DCE-MRI alone (reader 1, 80.6% [54/67], p = 0.005; reader 2, 83.6% [56/67], p = 0.04). The specificities were insignificantly lower in combined technique (reader 1, 88.4% [107/121]; reader 2, 77.7% [94/121]) than in DCE-MRI alone (reader 1, 90.9% [110/121], p = 0.67; reader 2, 79.3% [96/121], p = 0.88). The inter-reader agreement of the LI-RADS scores between combined technique and DCE-MRI was good (κ = 0.765). CONCLUSION: The use of DWI/ADC as an additional major criterion, improved the sensitivity of LI-RADS in the diagnosis of HCC while keeping high specificity.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA