Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 231
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(1): 169-185, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37994240

RESUMO

BACKGROUND: Vascular complications after percutaneous transfemoral transcatheter aortic valve implantation (TAVI) are associated with adverse clinical outcomes and remain a significant challenge. AIMS: The purpose of this review is to synthesize the existing evidence regarding the iliofemoral artery features predictive of vascular complications after TAVI on pre-procedural contrast-enhanced multidetector computed tomography (MDCT). METHODS: A systematic search was performed in Embase and Medline (Pubmed) databases. Studies of patients undergoing transfemoral TAVI with MDCT were included. Studies with only valve-in-valve TAVI, planned surgical intervention and those using fluoroscopic assessment were excluded. Data on study cohort, procedural characteristics and significant predictors of vascular complications were extracted. RESULTS: We identified 23 original studies involving 8697 patients who underwent TAVI between 2006 and 2020. Of all patients, 8514 (97.9%) underwent percutaneous transfemoral-TAVI, of which 8068 (94.8%) had contrast-enhanced MDCT. The incidence of major vascular complications was 6.7 ± 4.1% and minor vascular complications 26.1 ± 7.8%. Significant independent predictors of major and minor complications related to vessel dimensions were common femoral artery depth (>54 mm), sheath-to-iliofemoral artery diameter ratio (>0.91-1.19), sheath-to-femoral artery diameter ratio (>1.03-1.45) and sheath-to-femoral artery area ratio (>1.35). Substantial iliofemoral vessel tortuosity predicted 2-5-fold higher vascular risk. Significant iliofemoral calcification predicted 2-5-fold higher risk. The iliac morphology score was the only hybrid scoring system with predictive value. CONCLUSIONS: Independent iliofemoral predictors of access-site complications in TAVI were related to vessel size, depth, calcification and tortuosity. These should be considered when planning transfemoral TAVI and in the design of future risk prediction models.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Doenças Vasculares , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Doenças Vasculares/complicações
2.
J Cardiovasc Magn Reson ; 25(1): 5, 2023 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-36717885

RESUMO

BACKGROUND: Decisions in the management of aortic stenosis are based on the peak pressure drop, captured by Doppler echocardiography, whereas gold standard catheterization measurements assess the net pressure drop but are limited by associated risks. The relationship between these two measurements, peak and net pressure drop, is dictated by the pressure recovery along the ascending aorta which is mainly caused by turbulence energy dissipation. Currently, pressure recovery is considered to occur within the first 40-50 mm distally from the aortic valve, albeit there is inconsistency across interventionist centers on where/how to position the catheter to capture the net pressure drop. METHODS: We developed a non-invasive method to assess the pressure recovery distance based on blood flow momentum via 4D Flow cardiovascular magnetic resonance (CMR). Multi-center acquisitions included physical flow phantoms with different stenotic valve configurations to validate this method, first against reference measurements and then against turbulent energy dissipation (respectively n = 8 and n = 28 acquisitions) and to investigate the relationship between peak and net pressure drops. Finally, we explored the potential errors of cardiac catheterisation pressure recordings as a result of neglecting the pressure recovery distance in a clinical bicuspid aortic valve (BAV) cohort of n = 32 patients. RESULTS: In-vitro assessment of pressure recovery distance based on flow momentum achieved an average error of 1.8 ± 8.4 mm when compared to reference pressure sensors in the first phantom workbench. The momentum pressure recovery distance and the turbulent energy dissipation distance showed no statistical difference (mean difference of 2.8 ± 5.4 mm, R2 = 0.93) in the second phantom workbench. A linear correlation was observed between peak and net pressure drops, however, with strong dependences on the valvular morphology. Finally, in the BAV cohort the pressure recovery distance was 78.8 ± 34.3 mm from vena contracta, which is significantly longer than currently accepted in clinical practise (40-50 mm), and 37.5% of patients displayed a pressure recovery distance beyond the end of the ascending aorta. CONCLUSION: The non-invasive assessment of the distance to pressure recovery is possible by tracking momentum via 4D Flow CMR. Recovery is not always complete at the ascending aorta, and catheterised recordings will overestimate the net pressure drop in those situations. There is a need to re-evaluate the methods that characterise the haemodynamic burden caused by aortic stenosis as currently clinically accepted pressure recovery distance is an underestimation.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Humanos , Valor Preditivo dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Valva Aórtica/diagnóstico por imagem , Hemodinâmica , Espectroscopia de Ressonância Magnética , Velocidade do Fluxo Sanguíneo/fisiologia
3.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37314196

RESUMO

AIMS: The standard implantable cardioverter defibrillator (ICD) generator (can) is placed in the left pectoral area; however, in certain circumstances, right-sided cans may be required which may increase defibrillation threshold (DFT) due to suboptimal shock vectors. We aim to quantitatively assess whether the potential increase in DFT of right-sided can configurations may be mitigated by alternate positioning of the right ventricular (RV) shocking coil or adding coils in the superior vena cava (SVC) and coronary sinus (CS). METHODS AND RESULTS: A cohort of CT-derived torso models was used to assess DFT of ICD configurations with right-sided cans and alternate positioning of RV shock coils. Efficacy changes with additional coils in the SVC and CS were evaluated. A right-sided can with an apical RV shock coil significantly increased DFT compared to a left-sided can [19.5 (16.4, 27.1) J vs. 13.3 (11.7, 19.9) J, P < 0.001]. Septal positioning of the RV coil led to a further DFT increase when using a right-sided can [26.7 (18.1, 36.1) J vs. 19.5 (16.4, 27.1) J, P < 0.001], but not a left-sided can [12.1 (8.1, 17.6) J vs. 13.3 (11.7, 19.9) J, P = 0.099). Defibrillation threshold of a right-sided can with apical or septal coil was reduced the most by adding both SVC and CS coils [19.5 (16.4, 27.1) J vs. 6.6 (3.9, 9.9) J, P < 0.001, and 26.7 (18.1, 36.1) J vs. 12.1 (5.7, 13.5) J, P < 0.001]. CONCLUSION: Right-sided, compared to left-sided, can positioning results in a 50% increase in DFT. For right-sided cans, apical shock coil positioning produces a lower DFT than septal positions. Elevated right-sided can DFTs may be mitigated by utilizing additional coils in SVC and CS.


Assuntos
Seio Coronário , Desfibriladores Implantáveis , Humanos , Veia Cava Superior/diagnóstico por imagem , Simulação por Computador , Ventrículos do Coração
4.
Europace ; 25(2): 469-477, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36369980

RESUMO

AIMS: Existing strategies that identify post-infarct ventricular tachycardia (VT) ablation target either employ invasive electrophysiological (EP) mapping or non-invasive modalities utilizing the electrocardiogram (ECG). Their success relies on localizing sites critical to the maintenance of the clinical arrhythmia, not always recorded on the 12-lead ECG. Targeting the clinical VT by utilizing electrograms (EGM) recordings stored in implanted devices may aid ablation planning, enhancing safety and speed and potentially reducing the need of VT induction. In this context, we aim to develop a non-invasive computational-deep learning (DL) platform to localize VT exit sites from surface ECGs and implanted device intracardiac EGMs. METHODS AND RESULTS: A library of ECGs and EGMs from simulated paced beats and representative post-infarct VTs was generated across five torso models. Traces were used to train DL algorithms to localize VT sites of earliest systolic activation; first tested on simulated data and then on a clinically induced VT to show applicability of our platform in clinical settings. Localization performance was estimated via localization errors (LEs) against known VT exit sites from simulations or clinical ablation targets. Surface ECGs successfully localized post-infarct VTs from simulated data with mean LE = 9.61 ± 2.61 mm across torsos. VT localization was successfully achieved from implanted device intracardiac EGMs with mean LE = 13.10 ± 2.36 mm. Finally, the clinically induced VT localization was in agreement with the clinical ablation volume. CONCLUSION: The proposed framework may be utilized for direct localization of post-infarct VTs from surface ECGs and/or implanted device EGMs, or in conjunction with efficient, patient-specific modelling, enhancing safety and speed of ablation planning.


Assuntos
Ablação por Cateter , Aprendizado Profundo , Taquicardia Ventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Eletrocardiografia/métodos , Infarto/cirurgia
5.
Catheter Cardiovasc Interv ; 100(2): 227-232, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35686532

RESUMO

OBJECTIVES: We describe the first experience using calcification of anatomical landmarks to obviate the need for transcatheter aortic valve implantation (TAVI) alignment aortography and secondary TAVI access. BACKGROUND: TAVI alignment conventionally involves secondary femoral access for contrast aortography using a second catheter. Secondary femoral access accounts for up to 25% of all vascular complications. Heavily calcified aortic leaflets are often visible fluoroscopically and can act as markers for TAVI alignment. METHODS: We considered 100 consecutive patients for transfemoral TAVI. The first group was considered for a conventional dual access technique and the subsequent group was considered for a single access technique. Relevant baseline, and procedural and outcome measures were recorded. RESULTS: Baseline characteristics were comparable between groups. Balloon-expandable transcatheter heart valves (THV) were used in all cases. THV implantation was successful in 100% of cases with no procedural or in-hospital mortality. Procedural time and contrast use were lower in the single access group. There were no Valve Academic Research Consortium (VARC)-2 major vascular complications with the single access technique. CONCLUSIONS: This is the first study describing the use of calcification of anatomical landmarks to obviate the need for secondary TAVI access. Notable observations included successful device implantation in all cases, no VARC-2 major vascular complications, comparable rates of paravalvular leak and permanent pacemaker requirement, shorter procedural times, and lower contrast use. Single access TAVI is a viable alternative technique to minimize vascular access, contrast use, and procedural duration in experienced centers and with selected patients, allowing successful device implantation and low complication rates while further streamlining TAVI workflow.


Assuntos
Estenose da Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/diagnóstico por imagem , Humanos , Resultado do Tratamento
6.
Cardiology ; 147(4): 406-412, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35104821

RESUMO

BACKGROUND: Recent surveillance studies following nationwide mass vaccination are investigating rare complications such as myocarditis, pericarditis, and thromboembolic events related to mRNA-based Covid-19 vaccines. SUMMARY: In the current report, we present an overview of the incidence, clinical presentation and management of post-mRNA vaccine myocarditis, and pericarditis in view of the currently available data. Our main focus is directed toward myocarditis. KEY MESSAGES: Myocarditis following mRNA-based Covid-19 vaccines is rare, more frequently affects younger men <30 years and is usually of mild severity with spontaneous recovery. The overall benefit of mRNA vaccines in terms of protecting from severe Covid-19 infection and associated cardiovascular complications outweighs the risk of postvaccination myocarditis. Currently, there are no dedicated guidelines for patients with postvaccination myocarditis or pericarditis in terms of the frequency of follow-up including clinical assessment, repeated echocardiography, and cardiac resonance imaging. However, follow-up studies in terms of long-term consequences are underway.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Miocardite , Humanos , Masculino , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Incidência , Vacinas de mRNA , Miocardite/induzido quimicamente , Miocardite/epidemiologia , Miocardite/terapia , Pericardite/epidemiologia , RNA Mensageiro , Vacinas Sintéticas
7.
Cardiology ; 147(4): 453-460, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35168238

RESUMO

INTRODUCTION: Sex differences have been poorly studied in patients with right-sided heart valve disease. The principal aim of the current study was to explore the impact of sex differences on right ventricular (RV) hemodynamics and all-cause mortality in patients with moderate or severe tricuspid regurgitation (TR). METHODS: This is a retrospective study of 209 patients with significant TR. All patients were clinically profiled at baseline and underwent a transthoracic echocardiogram. The cohort was followed up for clinical events for a median duration of 80 months (mean ± SD 69.4 ± 33.4 months). RESULTS: There were 117 women with a mean (± SD) age of 72.6 ± 13 years and 92 men with a mean (± SD) age of 70.8 ± 15.8 years. There were no sex differences between the individual measures of RV systolic function (tricuspid annular plane systolic excursion [TAPSE], systolic pulmonary artery pressure, and RV S'), but overall RV systolic dysfunction (TAPSE <16 mm and/or RV S' <10 cm/s) and left ventricular ejection fraction <50% were more common in men. Mean (± SD) RV wall tension (RV WT) was 3,170 ± 1,220 mm Hg × mm in women and 3,817 ± 1,499 mm Hg × mm in men (p = 0.002). There was no difference in all-cause mortality between women and men (Log-Rank p = 0.528). Age and increased RV WT were independent predictors of all-cause mortality both in women (hazard ratio [HR] 2.61) and men (HR 3.01). CONCLUSIONS: In this cohort of patients with significant TR, women more frequently had preserved RV systolic function than men. There was no sex-difference in all-cause mortality. An increased RV WT and higher age were independent predictors of all-cause mortality in both women and men.


Assuntos
Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Volume Sistólico , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Função Ventricular Esquerda , Função Ventricular Direita
8.
Scand Cardiovasc J ; 56(1): 231-235, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35792896

RESUMO

Objectives. In patients with asymptomatic moderate or severe aortic stenosis (AS), exercise testing is used for evaluating the need for aortic valve intervention. Expert opinions about the clinical significance and prognostic value of ST segment depression on electrocardiography (ECG) during exercise testing in AS is conflicting and there are no large studies exploring this issue. We aimed to explore the association of ST segment depression >5 mm during exercise treadmill test (ETT) with all-cause mortality, aortic valve replacement (AVR) or cardiac-related hospitalization. Design. We performed a retrospective analysis of prospectively collected data of a total of 315 patients (mean age 65 ± 12 years, 67% men) with asymptomatic moderate (n = 209; 66%) or severe (n = 106; 34%) AS. All patients underwent clinical evaluation, echocardiography and ETT. Results. During a mean follow-up of 34.9 ± 34.6 months, 29 (9%) patients died and 235 (74%) underwent AVR. The prevalence of ST segment depression (>5 mm) was 13% (n = 41) in the total study population and was comparable in patients with revealed symptoms (17.6%, n = 16) versus without revealed symptoms (11.3%, n = 25; p = .132). ST segment depression on ETT was strongly associated with aortic valve area. In univariate Cox regression analysis, ST segment depression was not associated with cardiac related hospitalizations (HR 1.65; 95% CI 0.89-3.10, p = .113), all-cause mortality (HR 1.37; 95% CI 0.47-3.98, p = .564) or AVR (HR 1.30; 95% CI 0.89-1.91, p = .170). Conclusion. In patients with moderate or severe AS, ST segment depression during ETT is non-specific, carries no prognostic risk and should be used with caution in the clinical interpretation of exercise test.


Assuntos
Estenose da Valva Aórtica , Teste de Esforço , Idoso , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico , Eletrocardiografia , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Cardiovasc Ultrasound ; 20(1): 18, 2022 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-35840940

RESUMO

BACKGROUND: Transvalvular pressure drops are assessed using Doppler echocardiography for the diagnosis of heart valve disease. However, this method is highly user-dependent and may overestimate transvalvular pressure drops by up to 54%. This work aimed to assess transvalvular pressure drops using velocity fields derived from blood speckle imaging (BSI), as a potential alternative to Doppler.  METHODS: A silicone 3D-printed aortic valve model, segmented from a healthy CT scan, was placed within a silicone tube. A CardioFlow 5000MR flow pump was used to circulate blood mimicking fluid to create eight different stenotic conditions. Eight PendoTech pressure sensors were embedded along the tube wall to record ground-truth pressures (10 kHz). The simplified Bernoulli equation with measured probe angle correction was used to estimate pressure drop from maximum velocity values acquired across the valve using Doppler and BSI with a GE Vivid E95 ultrasound machine and 6S-D cardiac phased array transducer. RESULTS: There were no significant differences between pressure drops estimated by Doppler, BSI and ground-truth at the lowest stenotic condition (10.4 ± 1.76, 10.3 ± 1.63 vs. 10.5 ± 1.00 mmHg, respectively; p > 0.05). Significant differences were observed between the pressure drops estimated by the three methods at the greatest stenotic condition (26.4 ± 1.52, 14.5 ± 2.14 vs. 20.9 ± 1.92 mmHg for Doppler, BSI and ground-truth, respectively; p < 0.05). Across all conditions, Doppler overestimated pressure drop (Bias = 3.92 mmHg), while BSI underestimated pressure drop (Bias = -3.31 mmHg). CONCLUSIONS: BSI accurately estimated pressure drops only up to 10.5 mmHg in controlled phantom conditions of low stenotic burden. Doppler overestimated pressure drops of 20.9 mmHg. Although BSI offers a number of theoretical advantages to conventional Doppler echocardiography, further refinements and clinical studies are required with BSI before it can be used to improve transvalvular pressure drop estimation in the clinical evaluation of aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Ecocardiografia Doppler , Humanos , Silicones
10.
Eur Heart J ; 42(37): 3844-3852, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34269376

RESUMO

AIMS: Fractional flow reserve (FFRCT) using computed tomography coronary angiography (CTCA) determines both the presence of coronary artery disease and vessel-specific ischaemia. We tested whether an evaluation strategy based on FFRCT would improve economic and clinical outcomes compared with standard care. METHODS AND RESULTS: Overall, 1400 patients with stable chest pain in 11 centres were randomized to initial testing with CTCA with selective FFRCT (experimental group) or standard clinical care pathways (standard group). The primary endpoint was total cardiac costs at 9 months. Secondary endpoints were angina status, quality of life, major adverse cardiac and cerebrovascular events, and use of invasive coronary angiography. Randomized groups were similar at baseline. Most patients had an initial CTCA: 439 (63%) in the standard group vs. 674 (96%) in the experimental group, 254 of whom (38%) underwent FFRCT. Mean total cardiac costs were higher by £114 (+8%) in the experimental group, with a 95% confidence interval from -£112 (-8%) to +£337 (+23%), though the difference was not significant (P = 0.10). Major adverse cardiac and cerebrovascular events did not differ significantly (10.2% in the experimental group vs. 10.6% in the standard group) and angina and quality of life improved to a similar degree over follow-up in both randomized groups. Invasive angiography was reduced significantly in the experimental group (19% vs. 25%, P = 0.01). CONCLUSION: A strategy of CTCA with selective FFRCT in patients with stable angina did not differ significantly from standard clinical care pathways in cost or clinical outcomes, but did reduce the use of invasive coronary angiography.


Assuntos
Angina Estável , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angina Estável/diagnóstico por imagem , Angina Estável/terapia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários , Humanos , Valor Preditivo dos Testes , Qualidade de Vida
11.
Psychol Health Med ; 27(6): 1381-1396, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33947277

RESUMO

Heart failure (HF) is a syndrome associated with high mortality and morbidity. HF patients tend to be at a high risk of poor clinical and psychosocial outcomes. This study aimed to capture patients' and carers perspectives of HF, the impact on their health reported QoL, and the factors associated with their poor health outcomes. To explore HF patients' and carers' views on their QoL since diagnosis. This study used a cross-sectional, qualitative design with semi-structured interviews conducted with participating patients and carers. Thirteen adults (> 18 years) with HF and 21 carers were interviewed over the telephone, following a semi-structured interview schedule. Interviews were transcribed verbatim and analysed using inductive thematic analysis. Three main themes were identified, with an overarching theme . Themes included impact on patients' lifestyle including diet, smoking and inability to part-take in social activities, adjusting to HF diagnosis and co-morbidity management, and psychological/mental health issues such as anxiety and depression. Patients with HF are at high-risk of various issues which can negatively impact their QoL. Additionally, Carers play a vital role in the management of HF patients. Effective patient centred care and better communication between patients, carers and healthcare professionals is vital in HF management.


Assuntos
Cuidadores , Insuficiência Cardíaca , Adulto , Cuidadores/psicologia , Estudos Transversais , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/psicologia , Humanos , Pesquisa Qualitativa , Qualidade de Vida/psicologia
12.
J Cardiovasc Electrophysiol ; 32(3): 802-812, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33484216

RESUMO

BACKGROUND: Optimal positioning of the left ventricular (LV) lead is an important determinant of cardiac resynchronization therapy (CRT) response. OBJECTIVE: Evaluate the feasibility of intraprocedural integration of cardiac computed tomography (CT) to guide LV lead implantation for CRT upgrades. METHODS: Patients undergoing LV lead upgrade underwent ECG-gated cardiac CT dyssynchrony and LV scar assessment. Target American Heart Association segment selection was determined using latest non-scarred mechanically activating segments overlaid onto real-time fluoroscopy with image co-registration to guide optimal LV lead implantation. Hemodynamic validation was performed using a pressure wire in the LV cavity (dP/dtmax) ). RESULTS: 18 patients (male 94%, 55.6% ischemic cardiomyopathy) with RV pacing burden 60.0 ± 43.7% and mean QRS duration 154 ± 30 ms underwent cardiac CT. 10/10 ischemic patients had CT evidence of scar and these segments were excluded as targets. Seventeen out of 18 (94%) patients underwent successful LV lead implantation with delivery to the CT target segment in 15 out of 18 (83%) of patients. Acute hemodynamic response (dP/dtmax ≥ 10%) was superior with LV stimulation in CT target versus nontarget segments (83.3% vs. 25.0%; p = .012). Reverse remodeling at 6 months (LV end-systolic volume improvement ≥15%) occurred in 60% of subjects (4/8 [50.0%] ischemic cardiomyopathy vs. 5/7 [71.4%] nonischemic cardiomyopathy, p = .608). CONCLUSION: Intraprocedural integration of cardiac CT to guide optimal LV lead placement is feasible with superior hemodynamics when pacing in CT target segments and favorable volumetric response rates, despite a high proportion of patients with ischemic cardiomyopathy. Multicentre, randomized controlled studies are needed to evaluate whether intraprocedural integration of cardiac CT is superior to standard care.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Tomografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
J Cardiovasc Magn Reson ; 23(1): 57, 2021 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-33993890

RESUMO

BACKGROUND: The widespread clinical application of coronary cardiovascular magnetic resonance (CMR) angiography (CMRA) for the assessment of coronary artery disease (CAD) remains limited due to low scan efficiency leading to prolonged and unpredictable acquisition times; low spatial-resolution; and residual respiratory motion artefacts resulting in limited image quality. To overcome these limitations, we have integrated highly undersampled acquisitions with image-based navigators and non-rigid motion correction to enable high resolution (sub-1 mm3) free-breathing, contrast-free 3D whole-heart coronary CMRA with 100% respiratory scan efficiency in a clinically feasible and predictable acquisition time. OBJECTIVES: To evaluate the diagnostic performance of this coronary CMRA framework against coronary computed tomography angiography (CTA) in patients with suspected CAD. METHODS: Consecutive patients (n = 50) with suspected CAD were examined on a 1.5T CMR scanner. We compared the diagnostic accuracy of coronary CMRA against coronary CTA for detecting a ≥ 50% reduction in luminal diameter. RESULTS: The 50 recruited patients (55 ± 9 years, 33 male) completed coronary CMRA in 10.7 ± 1.4 min. Twelve (24%) had significant CAD on coronary CTA. Coronary CMRA obtained diagnostic image quality in 95% of all, 97% of proximal, 97% of middle and 90% of distal coronary segments. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were: per patient (100%, 74%, 55%, 100% and 80%), per vessel (81%, 88%, 46%, 97% and 88%) and per segment (76%, 95%, 44%, 99% and 94%) respectively. CONCLUSIONS: The high diagnostic image quality and diagnostic performance of coronary CMRA compared against coronary CTA demonstrates the potential of coronary CMRA as a robust and safe non-invasive alternative for excluding significant disease in patients at low-intermediate risk of CAD.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
14.
Anesth Analg ; 133(2): 292-302, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33684086

RESUMO

BACKGROUND: Prospective, single-center trials have shown that the implementation of the Kidney Disease: Improving Global Outcomes (KDIGO) recommendations in high-risk patients significantly reduced the development of acute kidney injury (AKI) after surgery. We sought to evaluate the feasibility of implementing a bundle of supportive measures based on the KDIGO guideline in high-risk patients undergoing cardiac surgery in a multicenter setting in preparation for a large definitive trial. METHODS: In this multicenter, multinational, randomized controlled trial, we examined the adherence to the KDIGO bundle consisting of optimization of volume status and hemodynamics, functional hemodynamic monitoring, avoidance of nephrotoxic drugs, and prevention of hyperglycemia in high-risk patients identified by the urinary biomarkers tissue inhibitor of metalloproteinases-2 [TIMP-2] and insulin growth factor-binding protein 7 [IGFBP7] after cardiac surgery. The primary end point was the adherence to the bundle protocol and was evaluated by the percentage of compliant patients with a 95% confidence interval (CI) according to Clopper-Pearson. Secondary end points included the development and severity of AKI. RESULTS: In total, 278 patients were included in the final analysis. In the intervention group, 65.4% of patients received the complete bundle as compared to 4.2% in the control group (absolute risk reduction [ARR] 61.2 [95% CI, 52.6-69.9]; P < .001). AKI rates were statistically not different in both groups (46.3% intervention versus 41.5% control group; ARR -4.8% [95% CI, -16.4 to 6.9]; P = .423). However, the occurrence of moderate and severe AKI was significantly lower in the intervention group as compared to the control group (14.0% vs 23.9%; ARR 10.0% [95% CI, 0.9-19.1]; P = .034). There were no significant effects on other specified secondary outcomes. CONCLUSIONS: Implementation of a KDIGO-derived treatment bundle is feasible in a multinational setting. Furthermore, moderate to severe AKI was significantly reduced in the intervention group.


Assuntos
Injúria Renal Aguda/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fidelidade a Diretrizes/normas , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/urina , Pacotes de Assistência ao Paciente/normas , Guias de Prática Clínica como Assunto/normas , Inibidor Tecidual de Metaloproteinase-2/urina , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/urina , Idoso , Biomarcadores/urina , Europa (Continente) , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
Echocardiography ; 38(11): 1893-1899, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34713486

RESUMO

OBJECTIVE: In aortic stenosis (AS), chronic pressure overload on left ventricle (LV) leads to LV hypertrophy, impaired relaxation, increased chamber stiffness, fibrosis and left atrial (LA) dilatation. An enlarged LA may be a marker of longstanding diastolic dysfunction (DD) and more advanced disease in AS. We aimed to assess the impact of LA volume index (LAVI) on events in patients with moderate or severe AS. METHODS: A total of 324 patients (mean age 69 ± 13 years, 61% men) were included. LA volume was measured by biplane Simpson's method using apical four- and two-chamber views and indexed to body surface area. An increased LAVI was defined as > 34 ml/m2 . RESULTS: The mean EF was 64 ± 8%, LAVI 35 ± 14 ml/m2 and flow rate 244 ± 70 ml/s. The number of total events was 275 (85%): 243 (75%) aortic valve replacement and 32 (10%) deaths. Mean follow-up 23.7 ± 23.8 months (median 15.2 months). An increased LAVI (45% [n = 145]) was associated with adverse events (HR 1.86; 95% CI 1.24-2.82, p = 0.003) independent of age, smoking, diabetes, atrial fibrillation, LV ejection fraction, LV mass, aortic valve area, and low flow rate (<200 ml/s). In the same multivariate model, when increased LAVI was replaced by E/e' ratio ≥14 cm, no association was found between E/e' ratio ≥14 cm and adverse events (HR 1.18; 95% CI .78-1.78, p = 0.430). CONCLUSION: LAVI was an independent predictor of adverse events in patients with moderate or severe AS and preserved ejection fraction. Including LAVI in the risk assessment of AS patients may further improve risk stratification.


Assuntos
Estenose da Valva Aórtica , Átrios do Coração , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Hipertrofia Ventricular Esquerda , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Esquerda
16.
J Clin Ultrasound ; 49(9): 932-935, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34505640

RESUMO

In aortic stenosis (AS), a left ventricular (LV) ejection fraction (EF) <50% or symptoms are class I indications for aortic valve intervention. However, an EF <50% may be too conservative since subendocardial fibrosis may already have developed. An earlier marker of LV systolic dysfunction is therefore needed and first phase EF (EF1) is a promising new candidate. It is the EF measured over early systole to the point of maximum transaortic blood flow. It may be low in the presence of preserved total LV EF since the heart may compensate by recruiting myosin motors in later systole. The EF1 is inversely related to the grade of AS and directly related to markers of subendocardial fibrosis like late gadolinium enhancement on cardiac magnetic resonance scanning. A reduced EF1 (<25%) predicts adverse clinical events better that total EF and global longitudinal strain. We suggest that it is worth exploring as an indication for surgery in patients with asymptomatic severe AS.


Assuntos
Estenose da Valva Aórtica , Disfunção Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Meios de Contraste , Ecocardiografia , Gadolínio , Humanos , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
17.
Pak J Med Sci ; 37(3): 908-912, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34104187

RESUMO

At the end of 2019 a novel coronavirus was identified in Wuhan, China. The disease caused by the severe acute respiratory distress syndrome coronavirus 2 (SARS-CoV-2) was designated COVID-19 (corona virus disease 2019) by the World Health Organization in early 2020. Up to 80% of patients with COVID-19 experience mild symptoms with severe or critical disease occurring in the remaining 20%. Severe disease is manifested by the development of pneumonia, hypoxia and radiographic lung involvement while critical disease indicates multiorgan involvement with significant respiratory or cardiac compromise. The current estimated case fatality rate from COVID-19 is approximately 1%. Epidemiological studies have shown that advanced age, male gender, previous chronic lung disease, cardiovascular and kidney disease, obesity and diabetes are risk factors for the severity of disease course. In the current focused review, we present an overview of the acute cardiovascular complications of COVID-19, their detection and impact upon prognosis.

18.
Lancet ; 393(10166): 61-73, 2019 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-30429050

RESUMO

BACKGROUND: Patients with dilated cardiomyopathy whose symptoms and cardiac function have recovered often ask whether their medications can be stopped. The safety of withdrawing treatment in this situation is unknown. METHODS: We did an open-label, pilot, randomised trial to examine the effect of phased withdrawal of heart failure medications in patients with previous dilated cardiomyopathy who were now asymptomatic, whose left ventricular ejection fraction (LVEF) had improved from less than 40% to 50% or greater, whose left ventricular end-diastolic volume (LVEDV) had normalised, and who had an N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) concentration less than 250 ng/L. Patients were recruited from a network of hospitals in the UK, assessed at one centre (Royal Brompton and Harefield NHS Foundation Trust, London, UK), and randomly assigned (1:1) to phased withdrawal or continuation of treatment. After 6 months, patients in the continued treatment group had treatment withdrawn by the same method. The primary endpoint was a relapse of dilated cardiomyopathy within 6 months, defined by a reduction in LVEF of more than 10% and to less than 50%, an increase in LVEDV by more than 10% and to higher than the normal range, a two-fold rise in NT-pro-BNP concentration and to more than 400 ng/L, or clinical evidence of heart failure, at which point treatments were re-established. The primary analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT02859311. FINDINGS: Between April 21, 2016, and Aug 22, 2017, 51 patients were enrolled. 25 were randomly assigned to the treatment withdrawal group and 26 to continue treatment. Over the first 6 months, 11 (44%) patients randomly assigned to treatment withdrawal met the primary endpoint of relapse compared with none of those assigned to continue treatment (Kaplan-Meier estimate of event rate 45·7% [95% CI 28·5-67·2]; p=0·0001). After 6 months, 25 (96%) of 26 patients assigned initially to continue treatment attempted its withdrawal. During the following 6 months, nine patients met the primary endpoint of relapse (Kaplan-Meier estimate of event rate 36·0% [95% CI 20·6-57·8]). No deaths were reported in either group and three serious adverse events were reported in the treatment withdrawal group: hospital admissions for non-cardiac chest pain, sepsis, and an elective procedure. INTERPRETATION: Many patients deemed to have recovered from dilated cardiomyopathy will relapse following treatment withdrawal. Until robust predictors of relapse are defined, treatment should continue indefinitely. FUNDING: British Heart Foundation, Alexander Jansons Foundation, Royal Brompton Hospital and Imperial College London, Imperial College Biomedical Research Centre, Wellcome Trust, and Rosetrees Trust.


Assuntos
Cardiomiopatia Dilatada/tratamento farmacológico , Fármacos Cardiovasculares/administração & dosagem , Insuficiência Cardíaca/tratamento farmacológico , Suspensão de Tratamento , Biomarcadores/sangue , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/fisiopatologia , Fármacos Cardiovasculares/farmacologia , Esquema de Medicação , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Projetos Piloto , Prognóstico , Recidiva , Indução de Remissão , Volume Sistólico/efeitos dos fármacos , Resultado do Tratamento , Função Ventricular Esquerda/efeitos dos fármacos
19.
J Cardiovasc Electrophysiol ; 31(9): 2431-2439, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32639621

RESUMO

BACKGROUND: Leadless pacemakers preclude the need for permanent leads to pace endocardium. However, it is yet to be determined whether a leadless pacemaker of a similar design to those manufactured for the right ventricle (RV) fits within the left ventricle (LV), without interfering with intracardiac structures. METHODS: Cardiac computed tomography scans were obtained from 30 patients indicated for cardiac resynchronisation therapy upgrade. The mitral valve annulus, chordae tendineae, papillary muscles and LV endocardial wall were marked in the end-diastolic frame. Intracardiac structures motions were tracked through the cardiac cycle. Two pacemaker designs similar to commercially manufactured leadless systems (Abbott's Nanostim LCP and Medtronic's Micra TPS) as well as theoretical designs with calculated optimal dimensions were evaluated. Pacemakers were virtually placed across the LV endocardial surface and collisions between them and intracardiac structures were detected throughout the cycle. RESULTS: Probability maps of LV intracardiac structures collisions on a 16-segment AHA model indicated possible placement for the Nanostim LCP, Micra TPS, and theoretical designs. Thresholding these maps at a 20% chance of collision revealed only about 36% of the endocardial surface remained collision-free with the deployment of Micra TPS design. The same threshold left no collision-free surface in the case of the Nanostim LCP. To reach at least half of the LV endocardium, the volume of Micra TPS, which is the smaller design, needed to be decreased by 41%. CONCLUSION: Due to the presence of intracardiac structures, placement of leadless pacemakers with dimensions similar to commercially manufactured RV systems would be limited to apical regions.


Assuntos
Terapia de Ressincronização Cardíaca , Marca-Passo Artificial , Endocárdio/diagnóstico por imagem , Desenho de Equipamento , Ventrículos do Coração/diagnóstico por imagem , Humanos
20.
Catheter Cardiovasc Interv ; 96(1): 215-218, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31696657

RESUMO

Transcatheter mitral valve implantation (TMVI) is an emerging field in structural cardiology. A particularly difficult group to treat is high-risk patients requiring valve in mitral annular calcification (ViMAC) intervention, with overall poor procedural success and outcomes in recent registries. This case highlights an unusual complication of paravalvular regurgitation (PVL) through the uncovered stent frame of a balloon expandable transcatheter heart valve (THV) on the left ventricular side of the prosthesis, leading to mechanical hemolysis and subsequent anuric renal failure post a ViMAC procedure. Attempts to treat the PVL with an occlusion plug device were unsuccessful and led to left circumflex coronary occlusion secondary to mechanical compression of the vessel in the posterior mitral valve annulus, a previously unreported phenomenon. A repeat valve-in-valve procedure was performed to treat the PVL, and immediate angioplasty resolved the left circumflex occlusion. High-risk patients requiring TMVI pose multiple challenges to Heart Teams in the treatment of valve pathology. Optimal procedural planning, multimodality imaging, improved THVs, and the awareness of potential complications are fundamental in overcoming the learning curve of TMVI and improved outcome for patients requiring ViMAC.


Assuntos
Cateterismo Cardíaco/instrumentação , Oclusão Coronária/etiologia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemólise , Insuficiência da Valva Mitral/terapia , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Oclusão Coronária/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA