Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
BMC Med Imaging ; 13: 29, 2013 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-24004511

RESUMO

BACKGROUND: Activity of disease in patients with multiple sclerosis (MS) is monitored by detecting and delineating hyper-intense lesions on MRI scans. The Minimum Area Contour Change (MACC) algorithm has been created with two main goals: a) to improve inter-operator agreement on outlining regions of interest (ROIs) and b) to automatically propagate longitudinal ROIs from the baseline scan to a follow-up scan. METHODS: The MACC algorithm first identifies an outer bound for the solution path, forms a high number of iso-contour curves based on equally spaced contour values, and then selects the best contour value to outline the lesion. The MACC software was tested on a set of 17 FLAIR MRI images evaluated by a pair of human experts and a longitudinal dataset of 12 pairs of T2-weighted Fluid Attenuated Inversion Recovery (FLAIR) images that had lesion analysis ROIs drawn by a single expert operator. RESULTS: In the tests where two human experts evaluated the same MRI images, the MACC program demonstrated that it could markedly reduce inter-operator outline error. In the longitudinal part of the study, the MACC program created ROIs on follow-up scans that were in close agreement to the original expert's ROIs. Finally, in a post-hoc analysis of 424 follow-up scans 91% of propagated MACC were accepted by an expert and only 9% of the final accepted ROIS had to be created or edited by the expert. CONCLUSION: When used with an expert operator's verification of automatically created ROIs, MACC can be used to improve inter- operator agreement and decrease analysis time, which should improve data collected and analyzed in multicenter clinical trials.


Assuntos
Algoritmos , Encéfalo/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Reconhecimento Automatizado de Padrão/métodos , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
BMC Med Imaging ; 12: 17, 2012 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-22812697

RESUMO

BACKGROUND: Presented is the method "Detection and Outline Error Estimates" (DOEE) for assessing rater agreement in the delineation of multiple sclerosis (MS) lesions. The DOEE method divides operator or rater assessment into two parts: 1) Detection Error (DE) -- rater agreement in detecting the same regions to mark, and 2) Outline Error (OE) -- agreement of the raters in outlining of the same lesion. METHODS: DE, OE and Similarity Index (SI) values were calculated for two raters tested on a set of 17 fluid-attenuated inversion-recovery (FLAIR) images of patients with MS. DE, OE, and SI values were tested for dependence with mean total area (MTA) of the raters' Region of Interests (ROIs). RESULTS: When correlated with MTA, neither DE (ρ = .056, p=.83) nor the ratio of OE to MTA (ρ = .23, p=.37), referred to as Outline Error Rate (OER), exhibited significant correlation. In contrast, SI is found to be strongly correlated with MTA (ρ = .75, p < .001). Furthermore, DE and OER values can be used to model the variation in SI with MTA. CONCLUSIONS: The DE and OER indices are proposed as a better method than SI for comparing rater agreement of ROIs, which also provide specific information for raters to improve their agreement.


Assuntos
Algoritmos , Encéfalo/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Técnica de Subtração , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
3.
J Vestib Res ; 17(1): 39-46, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18219103

RESUMO

Both sound (s-) and galvanic (g-) vestibular-evoked myogenic potential (VEMP) enable us to study the saccular pathways. However, the VEMP can be abnormal for non-vestibular factors, such as insufficient activation of the sterno-cleido-mastoid (SCM) muscle or a lesion that involves the accessory nucleus and/or nerve or the SCM muscle. These drawbacks do not affect another technique that evaluates the saccular function: the N3 potential. We recorded both the s- and the g-VEMP and the N3 potential in a group of 31 healthy subjects to establish a reference range. The N3 potential and the s-VEMP were recordable bilaterally from all the subjects, whereas the g-VEMP was undetectable uni- or bilaterally in 7 subjects. The latency and amplitude values of the s-VEMP did not differ from those of the g-VEMP. For all three techniques, the latency and amplitude values from the right and from the left recording and/or stimulation side were the same. We suggest using normative latency and amplitude values based on the mean and ratio of the right- and left-side values. The s-VEMP, the N3 potential and the auditory evoked response (ABR) were compared in 15 subjects suffering from multiple sclerosis. The three techniques detected a similar number of abnormalities, but these abnormalities were not correlated. This suggests that these different techniques should be regarded as complementary in evaluating saccular function.


Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Potencial Evocado Motor/fisiologia , Esclerose Múltipla/fisiopatologia , Contração Muscular/fisiologia , Tempo de Reação/fisiologia , Sáculo e Utrículo/fisiologia , Estimulação Acústica , Adolescente , Adulto , Análise de Variância , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculos do Pescoço/fisiologia , Valores de Referência , Sáculo e Utrículo/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA