Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
N Engl J Med ; 388(22): 2037-2048, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36876756

RESUMO

BACKGROUND: Data from a 5-year follow-up of outcomes after transcatheter edge-to-edge repair of severe mitral regurgitation, as compared with outcomes after maximal doses of guideline-directed medical therapy alone, in patients with heart failure are now available. METHODS: We randomly assigned patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite the use of maximal doses of guideline-directed medical therapy to undergo transcatheter edge-to-edge repair plus receive medical therapy (device group) or to receive medical therapy alone (control group) at 78 sites in the United States and Canada. The primary effectiveness end point was all hospitalizations for heart failure through 2 years of follow-up. The annualized rate of all hospitalizations for heart failure, all-cause mortality, the risk of death or hospitalization for heart failure, and safety, among other outcomes, were assessed through 5 years. RESULTS: Of the 614 patients enrolled in the trial, 302 were assigned to the device group and 312 to the control group. The annualized rate of hospitalization for heart failure through 5 years was 33.1% per year in the device group and 57.2% per year in the control group (hazard ratio, 0.53; 95% confidence interval [CI], 0.41 to 0.68). All-cause mortality through 5 years was 57.3% in the device group and 67.2% in the control group (hazard ratio, 0.72; 95% CI, 0.58 to 0.89). Death or hospitalization for heart failure within 5 years occurred in 73.6% of the patients in the device group and in 91.5% of those in the control group (hazard ratio, 0.53; 95% CI, 0.44 to 0.64). Device-specific safety events within 5 years occurred in 4 of 293 treated patients (1.4%), with all the events occurring within 30 days after the procedure. CONCLUSIONS: Among patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite guideline-directed medical therapy, transcatheter edge-to-edge repair of the mitral valve was safe and led to a lower rate of hospitalization for heart failure and lower all-cause mortality through 5 years of follow-up than medical therapy alone. (Funded by Abbott; COAPT ClinicalTrials.gov number, NCT01626079.).


Assuntos
Cateterismo Cardíaco , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Seguimentos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
2.
Eur Heart J ; 45(33): 3031-3041, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Idoso , Estudos Prospectivos , Estenose da Valva Aórtica/cirurgia , Falha de Prótese , Desenho de Prótese , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Oclusão Coronária/cirurgia , Complicações Pós-Operatórias/epidemiologia
3.
Catheter Cardiovasc Interv ; 102(1): 145-154, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37178388

RESUMO

BACKGROUND: Mitral valve transcatheter edge-to-edge repair (M-TEER) is an effective option for treatment of mitral regurgitation (MR). We previously reported favorable 2-year outcomes for the PASCAL transcatheter valve repair system. OBJECTIVES: We report 3-year outcomes from the multinational, prospective, single-arm CLASP study with analysis by functional MR (FMR) and degenerative MR (DMR). METHODS: Patients with core-lab determined MR ≥ 3+ were deemed candidates for M-TEER by the local heart team. Major adverse events were assessed by an independent clinical events committee to 1 year and by sites thereafter. Echocardiographic outcomes were evaluated by the core laboratory to 3 years. RESULTS: The study enrolled 124 patients, 69% FMR; 31% DMR (60% NYHA class III-IVa, 100% MR ≥ 3+). The 3-year Kaplan-Meier estimate for survival was 75% (66% FMR; 92% DMR) and freedom from heart failure hospitalization (HFH) was 73% (64% FMR; 91% DMR), with 85% reduction in annualized HFH rate (81% FMR; 96% DMR) (p < 0.001). MR ≤ 2+ was achieved and maintained in 93% of patients (93% FMR; 94% DMR) and MR ≤ 1+ in 70% of patients (71% FMR; 67% DMR) (p < 0.001). The mean left ventricular end-diastolic volume (181 mL at baseline) decreased progressively by 28 mL [p < 0.001]. NYHA class I/II was achieved in 89% of patients (p < 0.001). CONCLUSIONS: The 3-year results from the CLASP study demonstrated favorable and durable outcomes with the PASCAL transcatheter valve repair system in patients with clinically significant MR. These results add to the growing body of evidence establishing the PASCAL system as a valuable therapy for patients with significant symptomatic MR.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Prospectivos , Resultado do Tratamento
4.
N Engl J Med ; 379(24): 2307-2318, 2018 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-30280640

RESUMO

BACKGROUND: Among patients with heart failure who have mitral regurgitation due to left ventricular dysfunction, the prognosis is poor. Transcatheter mitral-valve repair may improve their clinical outcomes. METHODS: At 78 sites in the United States and Canada, we enrolled patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite the use of maximal doses of guideline-directed medical therapy. Patients were randomly assigned to transcatheter mitral-valve repair plus medical therapy (device group) or medical therapy alone (control group). The primary effectiveness end point was all hospitalizations for heart failure within 24 months of follow-up. The primary safety end point was freedom from device-related complications at 12 months; the rate for this end point was compared with a prespecified objective performance goal of 88.0%. RESULTS: Of the 614 patients who were enrolled in the trial, 302 were assigned to the device group and 312 to the control group. The annualized rate of all hospitalizations for heart failure within 24 months was 35.8% per patient-year in the device group as compared with 67.9% per patient-year in the control group (hazard ratio, 0.53; 95% confidence interval [CI], 0.40 to 0.70; P<0.001). The rate of freedom from device-related complications at 12 months was 96.6% (lower 95% confidence limit, 94.8%; P<0.001 for comparison with the performance goal). Death from any cause within 24 months occurred in 29.1% of the patients in the device group as compared with 46.1% in the control group (hazard ratio, 0.62; 95% CI, 0.46 to 0.82; P<0.001). CONCLUSIONS: Among patients with heart failure and moderate-to-severe or severe secondary mitral regurgitation who remained symptomatic despite the use of maximal doses of guideline-directed medical therapy, transcatheter mitral-valve repair resulted in a lower rate of hospitalization for heart failure and lower all-cause mortality within 24 months of follow-up than medical therapy alone. The rate of freedom from device-related complications exceeded a prespecified safety threshold. (Funded by Abbott; COAPT ClinicalTrials.gov number, NCT01626079 .).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hospitalização/estatística & dados numéricos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/tratamento farmacológico , Insuficiência da Valva Mitral/mortalidade , Intervenção Coronária Percutânea , Falha de Prótese , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
5.
JAMA ; 326(11): 1034-1044, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34546301

RESUMO

Importance: There are limited data on outcomes of transcatheter aortic valve replacement (TAVR) for bicuspid aortic stenosis in patients at low surgical risk. Objective: To compare the outcomes of TAVR with a balloon-expandable valve for bicuspid vs tricuspid aortic stenosis in patients who are at low surgical risk. Design, Setting, and Participants: Registry-based cohort study of patients undergoing TAVR at 684 US centers. Participants were enrolled in the Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapies Registry from June 2015 to October 2020. Among 159 661 patients (7058 bicuspid, 152 603 tricuspid), 37 660 patients (3243 bicuspid and 34 417 tricuspid) who were at low surgical risk (defined as STS risk score <3%) were included in the analysis. Exposures: TAVR for bicuspid vs tricuspid aortic stenosis. Main Outcomes and Measures: Coprimary outcomes were 30-day and 1-year mortality and stroke. Secondary outcomes included procedural complications and valve hemodynamics. Results: Among 159 661 patients (7058 bicuspid; 152 603 tricuspid), 3168 propensity-matched pairs of patients with bicuspid and tricuspid aortic stenosis at low surgical risk were analyzed (mean age, 69 years; 69.8% men; mean [SD] STS-predicted risk of mortality, 1.7% [0.6%] for bicuspid and 1.7% [0.7%] for tricuspid). There was no significant difference between the bicuspid and tricuspid groups' rates of death at 30 days (0.9% vs 0.8%; hazard ratio [HR], 1.18 [95% CI, 0.68-2.03]; P = .55) and at 1 year (4.6% vs 6.6%; HR, 0.75 [95% CI, 0.55-1.02]; P = .06) or stroke at 30 days (1.4% vs 1.2%; HR, 1.14 [95% CI, 0.73-1.78]; P = .55) and at 1 year (2.0% vs 2.1%; HR 1.03 [95% CI, 0.69-1.53]; P = .89).There were no significant differences between the bicuspid and tricuspid groups in procedural complications, valve hemodynamics (aortic valve gradient: 13.2 mm Hg vs 13.5 mm Hg; absolute risk difference [RD], 0.3 mm Hg [95% CI, -0.9 to 0.3 mm Hg]), and moderate or severe paravalvular leak (3.4% vs 2.1%; absolute RD, 1.3% [95% CI, -0.6% to 3.2%]). Conclusions and Relevance: In this preliminary, registry-based study of propensity-matched patients at low surgical risk who had undergone TAVR for aortic stenosis, patients treated for bicuspid vs tricuspid aortic stenosis had no significant difference in mortality or stroke at 30 days or 1 year. Because of the potential for selection bias and absence of a control group treated surgically for bicuspid aortic stenosis, randomized trials are needed to adequately assess the efficacy and safety of transcatheter aortic valve replacement for bicuspid aortic stenosis in patients at low surgical risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Pontuação de Propensão , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
Circulation ; 140(23): 1881-1891, 2019 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-31564137

RESUMO

BACKGROUND: The COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) demonstrated that edge-to-edge transcatheter mitral valve repair (TMVr) with the MitraClip resulted in reduced mortality and heart failure hospitalizations and improved quality of life compared with maximally tolerated guideline-directed medical therapy (GDMT) in patients with heart failure and 3 to 4+ secondary mitral regurgitation. Whether TMVr is cost-effective compared with GDMT in this population is unknown. METHODS: We used data from the COAPT trial to perform a formal patient-level economic analysis of TMVr+GDMT versus GDMT alone for patients with heart failure and 3 to 4+ secondary mitral regurgitation from the perspective of the US healthcare system. Costs for the index TMVr hospitalization were assessed using a combination of resource-based accounting and hospital billing data (when available). Follow-up medical care costs were estimated on the basis of medical resource use collected during the COAPT trial. Health utilities were estimated for all patients at baseline and 1, 6, 12, and 24 months with the Short Form Six-Dimension Health Survey. RESULTS: Initial costs for the TMVr procedure and index hospitalization were $35 755 and $48 198, respectively. Although follow-up costs were significantly lower with TMVr compared with GDMT ($26 654 versus $38 345; P=0.018), cumulative 2-year costs remained higher with TMVr because of the upfront cost of the index procedure ($73 416 versus $38 345; P<0.001). When in-trial survival, health utilities, and costs were modeled over a lifetime horizon, TMVr was projected to increase life expectancy by 1.13 years and quality-adjusted life-years by 0.82 years at a cost of $45 648, yielding a lifetime incremental cost-effectiveness ratio of $40 361 per life-year gained and $55 600 per quality-adjusted life-year gained. CONCLUSIONS: For symptomatic patients with heart failure and 3 to 4+ secondary mitral regurgitation, TMVr increases life expectancy and quality-adjusted life expectancy compared with GDMT at an incremental cost per quality-adjusted life-year gained that represents acceptable economic value according to current US thresholds. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01626079.


Assuntos
Cateterismo Cardíaco/economia , Procedimentos Endovasculares/economia , Insuficiência Cardíaca/cirurgia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Comorbidade , Análise Custo-Benefício , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/economia , Hospitalização/economia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/tratamento farmacológico , Insuficiência da Valva Mitral/economia , Estudos Multicêntricos como Assunto/estatística & dados numéricos , Próteses e Implantes/economia , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Volume Sistólico , Insuficiência da Valva Tricúspide/complicações , Estados Unidos
7.
Catheter Cardiovasc Interv ; 96(4): 793-801, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31721430

RESUMO

OBJECTIVES: We sought to compare clinical outcomes after percutaneous coronary intervention (PCI) in patients on versus not on hemodialysis (HD) and examine whether high on-treatment platelet reactivity (HPR) further impacts outcomes among patients on HD. BACKGROUND: Both chronic kidney disease (CKD) and HPR are predictors of major adverse cardiac events (MACE) after PCI. METHODS: Two-year outcomes of patients from the prospective, multicenter ADAPT-DES study (N = 8,582) were analyzed according to HD status at enrollment. All patients underwent platelet function testing with the VerifyNow assay; HPR on clopidogrel was defined as P2Y12 reaction units (PRU) >208. RESULTS: Compared with non-HD patients, patients on HD (n = 85) had significantly higher baseline PRU (median 254 vs. 188, p = .001) and more frequently had HPR (61.7% vs. 42.5%, p < .001). HD was associated with increased 2-year rates of MACE (death, myocardial infarction (MI) or definite stent thrombosis (ST); 23.4% vs. 10.7%, p < .001). HD was also strongly associated with 2-year overall mortality, cardiac death, MI, target vessel revascularization, major bleeding, stroke and ST. Following adjustment for HPR and other covariates, HD was independently associated with overall mortality, MI, ST, and major bleeding at 2 years. The relationship between HD status and 2-year MACE was consistent in patients with and without HPR (Pinteraction = .78). CONCLUSIONS: Nearly two-thirds of patients on HD exhibited HPR on clopidogrel, and both HD and HPR were independently associated with 2-year adverse outcomes after DES implantation. However, the deleterious impact of HD on clinical outcomes was present in both patients with and without HPR.


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Doença da Artéria Coronariana/terapia , Terapia Antiplaquetária Dupla , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Diálise Renal , Insuficiência Renal Crônica/terapia , Idoso , Aspirina/efeitos adversos , Clopidogrel/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/mortalidade , Trombose Coronária/prevenção & controle , Stents Farmacológicos , Terapia Antiplaquetária Dupla/efeitos adversos , Terapia Antiplaquetária Dupla/mortalidade , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Testes de Função Plaquetária , Estudos Prospectivos , Sistema de Registros , Diálise Renal/efeitos adversos , Diálise Renal/mortalidade , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Am Heart J ; 211: 68-76, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30897527

RESUMO

BACKGROUND: Chronic total occlusion (CTO) percutaneous coronary intervention (PCI) typically requires a greater number of stents and longer stent length than non-CTO PCI, placing these patients at greater risk for adverse ischemic events. We sought to determine whether the association between high platelet reactivity (HPR) and the risk of ischemic events is stronger after CTO than non-CTO PCI. METHODS: Patients undergoing successful PCI in the multicenter ADAPT-DES study were stratified according to whether they underwent PCI of a CTO. HPR was defined as VerifyNow platelet reaction units >208. The study primary endpoint was the 2-year risk target vessel failure ([TVF] defined as cardiac death, myocardial infarction, or target lesion revascularization). RESULTS: CTO PCI was performed in 400 of 8448 patients. HPR was present in 34.5% of CTO PCI patients and 43.1% of non-CTO PCI patients (P = .0007). Patients undergoing CTO PCI with versus without HPR had significantly higher 2-year rates of TVF (15.0% versus 8.3%, P = .04) without significant differences in bleeding. HPR was an independent predictor of 2-year TVF (adjusted HR 1.16, 95% CI 1.02-1.34, P = .03) whereas CTO PCI was not (adjusted HR 0.89, 95% CI 0.65-1.22, P = .48). There was a significant interaction between CTO versus non-CTO PCI and PRU as a continuous variable for 2-year TVF (Pinteraction = 0.02). CONCLUSIONS: In ADAPT-DES, HPR was associated with an increased 2-year risk of TVF after PCI, an association that was at least as strong after CTO PCI compared with non-CTO PCI.


Assuntos
Plaquetas/fisiologia , Oclusão Coronária/sangue , Oclusão Coronária/cirurgia , Stents Farmacológicos/efeitos adversos , Isquemia Miocárdica/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Aspirina/uso terapêutico , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias , Estudos Prospectivos , Desenho de Prótese
9.
JAMA ; 321(22): 2193-2202, 2019 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-31184741

RESUMO

Importance: Transcatheter aortic valve replacement (TAVR) indications are expanding, leading to an increasing number of patients with bicuspid aortic stenosis undergoing TAVR. Pivotal randomized trials conducted to obtain US Food and Drug Administration approval excluded bicuspid anatomy. Objective: To compare the outcomes of TAVR with a balloon-expandable valve for bicuspid vs tricuspid aortic stenosis. Design, Setting, and Participants: Registry-based prospective cohort study of patients undergoing TAVR at 552 US centers. Participants were enrolled in the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) Transcatheter Valve Therapies Registry from June 2015 to November 2018. Exposures: TAVR for bicuspid vs tricuspid aortic stenosis. Main Outcomes and Measures: Primary outcomes were 30-day and 1-year mortality and stroke. Secondary outcomes included procedural complications, valve hemodynamics, and quality of life assessment. Results: Of 81 822 consecutive patients with aortic stenosis (2726 bicuspid; 79 096 tricuspid), 2691 propensity-score matched pairs of bicuspid and tricuspid aortic stenosis were analyzed (median age, 74 years [interquartile range {IQR}, 66-81 years]; 39.1%, women; mean [SD] STS-predicted risk of mortality, 4.9% [4.0%] and 5.1% [4.2%], respectively). All-cause mortality was not significantly different between patients with bicuspid and tricuspid aortic stenosis at 30 days (2.6% vs 2.5%; hazard ratio [HR], 1.04, [95% CI, 0.74-1.47]) and 1 year (10.5% vs 12.0%; HR, 0.90 [95% CI, 0.73-1.10]). The 30-day stroke rate was significantly higher for bicuspid vs tricuspid aortic stenosis (2.5% vs 1.6%; HR, 1.57 [95% CI, 1.06-2.33]). The risk of procedural complications requiring open heart surgery was significantly higher in the bicuspid vs tricuspid cohort (0.9% vs 0.4%, respectively; absolute risk difference [RD], 0.5% [95% CI, 0%-0.9%]). There were no significant differences in valve hemodynamics. There were no significant differences in moderate or severe paravalvular leak at 30 days (2.0% vs 2.4%; absolute RD, 0.3% [95% CI, -1.3% to 0.7%]) and 1 year (3.2% vs 2.5%; absolute RD, 0.7% [95% CI, -1.3% to 2.7%]). At 1 year there was no significant difference in improvement in quality of life between the groups (difference in improvement in the Kansas City Cardiomyopathy Questionnaire overall summary score, -2.4 [95% CI, -5.1 to 0.3]; P = .08). Conclusions and Relevance: In this preliminary, registry-based study of propensity-matched patients who had undergone transcatheter aortic valve replacement for aortic stenosis, patients with bicuspid vs tricuspid aortic stenosis had no significant difference in 30-day or 1-year mortality but had increased 30-day risk for stroke. Because of the potential for selection bias and the absence of a control group treated surgically for bicuspid stenosis, randomized trials are needed to adequately assess the efficacy and safety of transcatheter aortic valve replacement for bicuspid aortic stenosis.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Pontuação de Propensão , Estudos Prospectivos , Sistema de Registros , Risco
10.
Am Heart J ; 205: 77-86, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30196181

RESUMO

BACKGROUND: Whether high on-aspirin platelet reactivity (HAPR) confers an increased risk of adverse outcomes after percutaneous coronary intervention (PCI) remains unclear. We sought to examine the specific relationship between HAPR and clinical outcomes in ADAPT-DES. METHODS: A total of 8,526 "all-comer" patients in the ADAPT-DES registry who underwent placement of drug-eluting stents (DES) and were treated with aspirin and clopidogrel were assessed to measure platelet reactivity. HAPR was characterized as ≥550 aspirin reaction units and high on-clopidogrel platelet reactivity as >208 P2Y12 reaction units. Univariable and propensity-adjusted multivariable analyses were used to assess the relationship between HAPR and clinical outcomes. RESULTS: HAPR was present in 478 (5.6%) patients. Patients with HAPR were older and had more comorbid illnesses and more complex coronary anatomy. During 2-year follow-up, HAPR was not associated with increased rates of major adverse cardiac events (MACE), stent thrombosis, myocardial infarction, or all-cause mortality. In propensity-adjusted multivariable analyses, HAPR was not an independent predictor of MACE after successful PCI (multivariable adjusted hazard ratio: 1.04; 95% CI 0.64-1.69, P = .87). Nor was HAPR associated with reduced bleeding. Even among patients with concomitant high on-clopidogrel platelet reactivity, HAPR was not associated with worse ischemic outcomes (adjusted hazard ratio for 2-year MACE: 1.06; 95% CI 0.55-2.00, P = .87). CONCLUSIONS: HAPR was infrequently present in a large registry of patients undergoing PCI. There was no clear relationship between HAPR and 2-year clinical outcomes. Investigations of antiplatelet regimens without aspirin after DES implantation are ongoing and should inform future management of patients undergoing PCI.


Assuntos
Clopidogrel/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Ativação Plaquetária/efeitos dos fármacos , Sistema de Registros , Idoso , Doença da Artéria Coronariana/tratamento farmacológico , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA