Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Exp Rheumatol ; 42(2): 344-350, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37812480

RESUMO

OBJECTIVES: We studied high-resolution impedance manometry (HRiM) findings in dermatomyositis (DM) to detect oesophageal dysmotility, even in asymptomatic patients, and correlated the alterations to clinical and serological disease domains. METHODS: We performed a cross-sectional study of DM patients, enrolled between December 2021 and December 2022. All patients underwent rheumatological, laboratory and HRiM assessment. HRiM findings were compared with different clinical and serological profiles. RESULTS: The study population consisted of 15 DM patients (13 women and 2 men, age 54±15.2 years). The mean disease duration was 6.6 years. According to HRiM findings, three different groups of oesophageal disease severity were identified (in order of severity G0, G1 and G>1, 5 patients per group). G>1 group was significantly associated with MDA5 antibodies (80% vs. 20%, p<0.05). Interstitial lung disease (ILD) did not show any significant association with HRiM findings. However, a diffusing lung capacity for carbon oxide (DLCO) < 80% was present in 100% of G>1 (p<0.05). No associations between dysphagia, creatine kinase (CK) level, muscle weakness, skin, articular involvement and treatment were found. CONCLUSIONS: Oesophageal involvement is frequent and should be evaluated in the comprehensive work-up of DM. We used for the first time HRiM in DM, which proved to be an accurate and objective technique in assessing oesophageal disease, even in the subclinical stage. Interestingly, the MDA5-positive group had a higher burden of HRiM pathological findings, suggesting a greater severity of oesophageal involvement, often asymptomatic.


Assuntos
Dermatomiosite , Transtornos da Motilidade Esofágica , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Dermatomiosite/complicações , Impedância Elétrica , Estudos Transversais , Transtornos da Motilidade Esofágica/etiologia , Transtornos da Motilidade Esofágica/complicações , Manometria/métodos , Estudos Retrospectivos , Autoanticorpos , Helicase IFIH1 Induzida por Interferon
2.
Ann Surg ; 274(1): 57-62, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33177355

RESUMO

OBJECTIVE: The aim of this prospective clinical study is to compare short-term outcome of laparoscopic right hemicolectomy using the Complete Mesocolic Excision (CME group) with patients who underwent conventional right-sided colonic resection (NCME group). SUMMARY BACKGROUND DATA: Although CME with central vascular ligation in laparoscopic right hemicolectomy is associated with a significant decrease in local recurrence rates and improvements in cancer-related 5-year survival, there may be additional risks associated with this technique because of increased surgical complications. As a result, there is controversy surrounding its use. METHODS: In this randomized controlled trial, several primary endpoints (operative time, intraoperative blood loss, other complications, conversion rate, and anastomotic leak) and secondary endpoints (overall postoperative complications) were evaluated. In addition, we evaluated histopathologic data, including specimen length and the number of lymph nodes harvested, as objective signs of the quality of CME, related to oncological outcomes. RESULTS: The CME group had a significantly longer mean operative time than the NCME group (216.3 minutes vs 191.5 minutes, P = 0.005). However, the CME group had a higher number of lymph nodes (23.8 vs 16.6; P < 0.001) and larger surgical specimens (34.3 cm vs 29.3 cm; P = 0.002). No differences were reported with respect to intraoperative blood loss, conversion rate, leakage, or other postoperative complications. CONCLUSIONS: In this study laparoscopic CME were a safe and feasible technique with improvement in lymph nodes harvesting and length of surgical specimens with no increase of surgical intraoperative and postoperative complications.


Assuntos
Colectomia/métodos , Neoplasias do Colo/cirurgia , Laparoscopia/métodos , Mesocolo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fístula Anastomótica , Perda Sanguínea Cirúrgica , Colectomia/efeitos adversos , Neoplasias do Colo/patologia , Conversão para Cirurgia Aberta , Estudos de Viabilidade , Feminino , Humanos , Laparoscopia/efeitos adversos , Excisão de Linfonodo , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Duração da Cirurgia , Complicações Pós-Operatórias , Estudos Prospectivos , Análise de Sobrevida , Resultado do Tratamento
3.
Artif Organs ; 45(8): 933-942, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33529348

RESUMO

Biologic response to hernia prostheses represents a continuous source of debate. Conventional hernia meshes, in their typical static, passive configuration have been used for decades to reinforce the herniated abdominal wall. These flat implants, mainly fixated with sutures or tacks, induce poor quality fibrotic ingrowth that shrinks the mesh. In groin hernia repair, flat meshes are applied in the delicate inguinal surrounding where uncontrolled development of a scar plate can impair movement and may incorporate the sensitive nerves crossing this area. Complications deriving from mesh fixation and nerve entrapment are frequent and unpleasant for patients. To remedy these problems, a multilamellar shaped 3D device with a dynamic responsive behavior has recently been developed to repair inguinal hernia. Its inherent dynamic compliance during inguinal movements has shown to induce enhanced biological response with ingrowth of newly formed connective tissue, muscle fibers, and nerves. The function of these highly specialized tissue structures is supported by the contextual development of newly formed arteries and veins. The scope of the study was to assess quantity and quality of vessels, which had ingrown in the 3D hernia device in the short-term, medium-term, and long-term post-implantation, in biopsy specimens gathered from inguinal hernia patients operated with the 3D device. Starting from an early stage, widespread angiogenesis was evident within the 3D structure. Arteries and veins increased in quantity showing progressive development until full maturation of all specific vascular components throughout the mid-term, to long-term, post-implantation. High quality biologic ingrowth in hernia prosthetics needs an adequate vascular support. The broad network of mature arteries and veins evidenced herewith seems to confirm the enhanced biological features of the dynamic responsive 3D device whose features resemble a regenerative scaffold, an ideal feature for the treatment of the degenerative source of inguinal hernia disease.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia/instrumentação , Neovascularização Fisiológica , Desenho de Prótese , Implantação de Prótese , Feminino , Humanos , Masculino , Polipropilenos
4.
Surg Technol Int ; 38: 199-205, 2021 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-33942884

RESUMO

Prosthetic inguinal hernia repair presents significant challenges. Some of these, such as mesh fixation and quality of the biologic response, are still debated among surgeons. For example, there is no strong consensus regarding a specific condition that characterizes the surgical procedure during herniorrhaphy. This issue concerns management of the hernia defect, which in conventional hernia repair with flat meshes remains patent. However, a critical analysis of typical postoperative complications after inguinal hernia repair reveals that some of these adverse events are related to patency of the hernial opening. Postoperative discomfort, pain with specific movements and even hernia recurrence can be caused by incomplete or defective management of the hernia defect. For this reason, a deeper understanding of this topic would be useful for improving postoperative outcomes. A recently updated concept for inguinal hernia repair takes this technical aspect into consideration. It is based on the use of a newly developed 3D scaffold-ProFlor™ (Insightra Medical, Inc., Clarksville, TN, USA)-that is intended to be deployed into the defect. This novel hernia repair device has interesting and original features, such as dynamic responsivity in compliance with inguinal movement, fixation-free mode and regenerative behavior that counteracts the degenerative effects of the disease. Another additional proprietary feature of this 3D scaffold is the full and permanent obliteration of the defect, which is a crucial aspect to improve outcomes by avoiding the typical adverse effects of this surgical procedure. Obliteration of the hernia defect with the 3D dynamic regenerative scaffold ProFlor™ appears to be superior to coverage by means of static (passive) flat meshes/plugs used in conventional hernia repair. This report highlights the principles of this procedural approach.


Assuntos
Hérnia Inguinal , Virilha/cirurgia , Hérnia Inguinal/cirurgia , Herniorrafia , Humanos , Dor Pós-Operatória , Próteses e Implantes , Recidiva , Telas Cirúrgicas
5.
Artif Organs ; 44(10): 1044-1049, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32324900

RESUMO

Ventricular assist devices (VADs) are considered the standard of care for end-stage heart failure (HF) patients. Despite increasing confidence in the technology, evidence data, endorsement by scientific societies and guidelines, the number of implants reached a steady state and is not increasing at the expected pace. This is most likely related to complications that are still burdening the technology and consequently excluding the most needy, ill, and fragile population. In this manuscript we are reporting a single-center experience in a very fragile, elderly and end-stage HF population, with a superficial, partial support device: the CircuLite Synergy. The patients were included in the pre-CE mark clinical study and consequently the device underwent technical adjustment during the support, based on the complications recorded. At our institution were implanted 6 patients overall: 3 patients survived to discharge and 2 survived up to 5 years. Most of the complications recorded were due to patients' frailty and overall clinical conditions. The initial experience with the CircuLite Synergy device is proving that a more "superficial" device might be more tolerable in an elderly, frail population. Partial support has proven hemodynamically efficacious and efficient in relieving heart failure symptoms, improving medical therapy tolerability, and improving quality of life. Unfortunately, the technology was not made available due to financial uncertainty and poor management, but we hope that once the concept has been proved someone will collect the legacy.


Assuntos
Fragilidade/complicações , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fragilidade/mortalidade , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento
6.
BMC Surg ; 20(1): 275, 2020 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-33160350

RESUMO

BACKGROUND: Obesity is a growing public health concern in most western countries. More and more patients with high body mass index (BMI) are undergoing surgical procedures of all kinds and, in this context, obese patients are undergoing thyroid surgery more than ever before. The aim of the present study was to evaluate whether thyroidectomy can be considered safe in obese patients. METHODS: Patients undergoing thyroidectomy in our Unit between January 2014 and December 2018 were retrospectively analysed. Patients were divided into two groups: those with BMI < 30 kg/m2 were included in Group A, while those with BMI ≥ 30 kg/m2 in Group B. Univariate analysis was performed to compare these two groups. Moreover, multivariate analyses were performed to evaluate whether the BMI value (considered in this case as a continuous variable) had a significant role in the development of each individual postoperative complication. RESULTS: A total of 813 patients were included in this study: 31 (3.81%) were underweight, 361 (44.40%) normal-weight, 286 (35.18%) overweight, 94 (11.57%) obese and 41 (5.04%) morbidly obese. Six hundred and seventy-eight patients were included in Group A and 135 in Group B. At univariate analysis, the comparison between the two groups, in terms of operative time and thyroid weight resulted in statistically significant results (P = 0.001, P = 0.008; respectively). These features were significantly higher in Group B than in Group A. About postoperative stay and complications, no statistically significant difference was found between the two groups. At multivariate analyses, only the development of cervical haematoma was statistically significantly correlated to the BMI value. Patients with high BMI had a lower risk of cervical haematoma (P = 0.045, OR 0.797, 95% CI 0.638-0.995). CONCLUSIONS: This study showed that obesity, in the field of thyroid surgery, is not associated with any increase of postoperative complications. Thus, it is possible to conclude that thyroidectomy can be performed safely in obese patients. Our result about operative times had no clinical significance.


Assuntos
Obesidade/complicações , Doenças da Glândula Tireoide/cirurgia , Tireoidectomia , Adulto , Idoso , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sobrepeso/complicações , Estudos Retrospectivos , Magreza/complicações , Doenças da Glândula Tireoide/complicações , Tireoidectomia/efeitos adversos , Tireoidectomia/métodos , Resultado do Tratamento
7.
Surg Technol Int ; 36: 105-111, 2020 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-32196561

RESUMO

INTRODUCTION: While many scientific reports deal with inguinal hernia, including treatment methods and prosthetic devices proposed to provide a cure, few studies have sought to deepen our understanding of the etiology of this disease. The genesis of inguinal protrusion seems to be a neglected subject, even though addressing hernia genesis may be helpful for improving techniques and materials for surgical treatment. To clarify the source of inguinal protrusions, macroscopic and histological alterations of the inferior epigastric vessels in the herniated groin have been studied. These vascular structures exhibit significant features that could help to illuminate hernia genesis. MATERIAL AND METHODS: In patients with double ipsilateral inguinal hernia, composed of distinct direct and indirect protrusions, a tissue septum separates the two defects. Macroscopic observation and histological examination of this septal arrangement were carried out in 23 patients to highlight characteristics of the inferior epigastric vessels in the posterior aspect of this anatomical area. RESULTS: The examined inferior epigastric vessels presented notable alterations of the gross anatomy and histologically significant damage, with a typical trait of chronic compressive damage. All degrees of degeneration were observed, including complete disbanding of the vascular structure. CONCLUSIONS: In pantaloon hernias, excised inferior epigastric vessels suffered from chronic compressive degeneration but had no contact with the protrusions. Therefore, protrusion expansion does not produce the degenerative injuries seen in the epigastric vessels. In the inguinal area, there is no source of chronic compression except visceral impact. Consequently, orthostatic visceral impact could be hypothesized to cause structural weakening of the groin, leading to tissue disbanding and visceral protrusion through the weakened inguinal floor.


Assuntos
Hérnia Inguinal , Virilha , Humanos
8.
BMC Surg ; 18(Suppl 1): 128, 2019 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-31074390

RESUMO

BACKGROUND: laparoscopic adrenalectomy has become the standard treatment for adrenal lesions. The better clinical outcoms of laparoscopic technique are valid for treatment of small benign masses (< 5-6 cm), instead there are still open questions in literature regarding the correct management of larger lesions (> 6 cm) or in case of potentially malignant adrenal tumors. The aim of this study is to evaluate the outcomes of laparoscopic adrenalectomy in a referral surgical department for endocrine surgery. METHODS: at the University Hospital Policlinico "P. Giaccone" of Palermo between January 2010 and December 2017 we performed a total of 81 laparoscopic adrenalectomy. We created a retrospective database with analysis of patients data, morphologic and hormonal characteristics of adrenal lesions, surgical procedures and postoperative results with histological diagnosis and complications. RESULTS: Mean size of adrenal neoplasm was 7,5 cm (range 1.5 to 18 cm). The mean operative time was 145 min (range 75-240). In statistical analysis lenght of surgery was correlated to the lesion diameter (p < 0.05) but not with pre-operative features or histological results. 5 intraoperative complications occurred. Among these patients 4 presented bleeding and 1 a diaphagmatic lesion. No conversion to open surgery was necessary and no intraoperative blood transfusion were required. Mean estimated blood loss was 95 ml (range 50-350). There was no capsular disruption during adrenal dissection. Mean length of hospital stay was 3.7 days (range 3-6 days). CONCLUSIONS: Laparoscopic adrenalectomy is a safe procedure with low rate of morbidity. An accurate preoperative radiological examination is fundamental to obtain a stringent patients selection. The lesion diameter is related to longer operative time and appeares as the main predictive parameter of intraoperative complications but these results are not statistically significant. On the other side secreting adrenal tumors require more attention in operative management without increased rate of postoperative complications.


Assuntos
Neoplasias das Glândulas Suprarrenais/cirurgia , Adrenalectomia/métodos , Laparoscopia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemorragia/epidemiologia , Humanos , Complicações Intraoperatórias/epidemiologia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Seleção de Pacientes , Complicações Pós-Operatórias/epidemiologia , Período Pós-Operatório , Estudos Retrospectivos
9.
Artif Organs ; 42(12): 1216-1223, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30318605

RESUMO

Despite undisputed improvements, prosthetics hernia repair continues to be affected by unacceptable rates of complications. Postoperative adverse events such as discomfort and chronic pain represent a subject of increasing concern among the surgical community. Poor quality biologic response, stiff scar plates, and mesh shrinkage, a typical effect of conventional static meshes and plugs, are all indicated as the main reasons for many of the complications related to inguinal hernia repair. Even the conventional concept of treatment based upon a supposed reinforcement of the groin consequent to the fibrotic incorporation of meshes, would appear to be inadequate in the light of the latest scientific evidence concerning the degenerative genesis of inguinal hernia. Following these recent studies, a newly conceived 3D dynamically responsive implant has been developed. It concerns a multilamellar shaped prosthesis, intended to be placed fixation-free to obliterate the hernia defect. This 3D structure has already demonstrated to induce a probiotic biological response with development of viable tissue, instead of the fibrotic plaque typical of conventional meshes. Newly formed elastic fibers, neo-angiogenesis, and neo-nerve genesis in a surrounding of well perfused connective tissue are the typical elements of the biologic response in the newly conceived implant. In addition to these elements, muscle fibers have also been detected in the implant structure. The aim of this research was to determine the ingrowth of muscle fibers in the implant by assessing the quantity and quality of muscle development in the short, medium, and long term post-implantation. Histological examination of biopsy samples excised from patients who underwent dynamic hernia repair with the 3D dynamic implant showed the presence of muscular elements that in the short term could be described as multiple spots of myocytes in the early stage of development. Over the mid- to long-term, muscle fibers increased in number and level of maturation, assuming the typical aspect of standard muscle bundles in the final phase. Effectively, long term, myocytes histologically evidenced the distinctive arrangement of the muscle structure, with nuclei and striated elements being similar to normal muscle elements. The development of this highly specialized connective tissue in the 3D dynamic responsive implant seems to document the finalization of an enhanced biologic response leading to the ingrowth of typical tissue components of the groin. Reverting degenerative pathogenesis into effective regeneration recognized in the newly conceived 3D prosthesis would appear to represent a significant concept change in the repair of inguinal hernias.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Desenvolvimento Muscular , Implantação de Prótese , Idoso , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Células Musculares/citologia
10.
Aging Clin Exp Res ; 29(Suppl 1): 173-177, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27837460

RESUMO

BACKGROUND: Incisional hernia in aged patients represents a challenge even for experienced surgeons. Besides increased risk of complications due to comorbidities, mesh fixation and assuring a sufficient mesh overlap of the defect are the main issues in carrying out the repair. AIMS: In order to assure broader coverage of the abdominal wall and a tension- and fixation-free repair, a specifically designed prosthesis was developed for the surgical treatment of incisional hernias. The results of a fixation-free incisional hernia repair carried out in elderly patients using a tentacle-shaped implant are reported herewith. METHODS: A tentacle-shaped flat mesh with a large central body and integrated arms was used to repair incisional hernia in 23 elderly patients. The mesh was placed fixation-free and secured in place through the friction exerted by the tentacles. All tentacle straps were positioned with a special passer needle. Implant placement was preperitoneal in 18 patients and retromuscular sublay in five. RESULTS: In a follow-up of 18 to 59 months (mean 36 months), four seromas occurred. Postoperative fast track helped avoid the typical complications affecting this patient subset. No infection, hematoma, chronic pain, mesh dislocation or recurrence have been reported to date. DISCUSSION: The tentacle strap system allowed for reduced skin incision thus minimizing surgical trauma and ensuring easier and faster implant placement. CONCLUSION: The tentacle arms of the implant ensured mesh stability and broad defect overlap. Besides a very low complication rate, none of the typical postoperative complications of aged patients occurred.


Assuntos
Técnicas de Fechamento de Ferimentos Abdominais , Hérnia Ventral/cirurgia , Hérnia Incisional/cirurgia , Complicações Pós-Operatórias/cirurgia , Telas Cirúrgicas , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos , Técnicas de Fechamento de Ferimentos Abdominais/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Próteses e Implantes , Recidiva
11.
Surg Technol Int ; 30: 175-181, 2017 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-28693050

RESUMO

INTRODUCTION: The fixation and the overlap of the mesh represent an open issue in incisional hernia repair. An exclusively designed prosthesis has been developed to assure a suture-free repair and a broader coverage of the abdominal wall. This study describes the long-term results of incisional hernia procedures carried out positioning a tentacle-shaped implant through a specifically developed surgical technique. MATERIALS AND METHODS: A proprietary symmetrically-shaped flat mesh constituted by a large central body with integrated radiating arms was used to repair incisional hernias in 68 patients. The prosthesis was placed in preperitoneal/retromuscular sublay. The friction of the straps passing through myotendineal structures of the abdomen was intended to assure an adequate grip to firmly hold the device in place with a broad overlap of the hernia defect in a fixation-free fashion. All tentacle straps were positioned through a special needle passer crossing the abdominal wall laterally from the defect borders then cut short in the subcutaneous layer. RESULTS: In a long-term follow-up of 12 to 96 months (mean 58 months), 11 seromas occurred. No infections, hematomas, chronic pain, mesh dislocation, or recurrence have been reported. CONCLUSIONS: The tentacle strap system of the prosthesis effectively ensured reduced skin incision and an easier implant placement avoiding the need for suturing the mesh. Regularly performed computed tomography (CT) and ultrasound (US) investigations proved that the arms of the implant ensured a proper orientation and stabilization of the mesh in association with a broad defect overlap. The specifically developed surgical procedure showed a quick postoperative recovery, a very low complication rate, and no recurrences, even in the long-term.


Assuntos
Herniorrafia , Hérnia Incisional/cirurgia , Telas Cirúrgicas , Parede Abdominal/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Herniorrafia/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Desenho de Prótese
12.
Int Heart J ; 58(5): 647-653, 2017 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-28966319

RESUMO

Although improved long-term outcomes obtained with the use of arterial grafts for coronary revascularization in comparison with the traditional association of a single arterial and saphenous vein grafts have been demonstrated in the overall population, the efficacy of this newer technique in the elderly is difficult to prove because their shorter life expectancy due to advanced heart disease, associated with severe comorbidities. Moreover, more widespread use of this technique is limited by the concerns on the potential morbidity, particularly the longer time required to perform the operation and the possibility of deep sternal wound infection in case of bilateral internal thoracic artery harvesting due to the decreased blood supply to the sternum and surrounding tissues.The review of the recent literature indicates that the use of bilateral internal thoracic arteries in very elderly patients should not be considered routinely. It seems reasonable to avoid it in octogenarians in the presence of well-known predictors of sternal complications such as diabetes, morbid obesity, and severe chronic lung disease.There is also still controversy about the superiority of the radial artery over the saphenous vein graft as a second or third conduit for surgical myocardial revascularization, although the majority of recent studies seem to support more liberal use of the radial artery as second arterial conduit in the elderly. Although a clinical benefit of arterial graft revascularization cannot be formally excluded for elderly patients, the increased complexity of this technique suggests that careful clinical judgment is necessary to select grafts for individual patients.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Artéria Torácica Interna/transplante , Artéria Radial/transplante , Idoso , Humanos
13.
Surg Endosc ; 30(7): 2804-10, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26490773

RESUMO

BACKGROUND/AIM: Laparotomy has been the approach of choice for re-operations in patients with surgical complications. The aim of this retrospective analysis was to evaluate the feasibility and the safety of laparoscopic approach for the management of general abdominal surgery complications. MATERIALS AND METHODS: We report a retrospective review of 75 patients who underwent laparoscopic evaluation for postoperative complications over a 4-year period. Primary outcomes (resolution rate by exclusive laparoscopic approach, conversion rate, further surgery rate) and secondary outcomes (mortality, hospitalization, prolonged ileus, wounds problems and median operative time) were evaluated. RESULTS: Sixty-six patients (88 %) were managed with laparoscopic approach without conversion; of these, sixty-three patients (84 %) had no more or further complications and were discharged from hospital between 4 ± 3 days after "second-look" surgery; three patients (4 %) developed postoperative complications requiring a third surgery. Nine cases (12 %) underwent conversion in open surgery after laparoscopic approach. Two elderly patients (2.7 %) died in intensive care unit, because of multi-organ failure syndrome. Median time elapsed between an intervention and another was about 2.5 ± 9.5 days. Mean operative time was 90 ± 150 min. Postoperative hospital stay was between 4.5 and 18 days. DISCUSSION AND CONCLUSION: Laparoscopy has begun to be the preferred method to manage postoperative problems, but only few reports are available actually. Our experience in "relaparoscopic" management of surgical complications seems to suggest that laparoscopy "second look" is an effective tool after open or laparoscopic surgery for the management of postoperative complications and it may avoid diagnostic delay and further laparotomy and related problems.


Assuntos
Abscesso Abdominal/cirurgia , Apendicectomia , Colecistectomia , Laparoscopia/métodos , Complicações Pós-Operatórias/cirurgia , Reoperação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Conversão para Cirurgia Aberta , Diagnóstico Tardio , Procedimentos Cirúrgicos do Sistema Digestório , Feminino , Humanos , Íleus/epidemiologia , Laparotomia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Mortalidade , Duração da Cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Cirurgia de Second-Look , Infecção da Ferida Cirúrgica/epidemiologia , Fatores de Tempo , Adulto Jovem
14.
Gastrointest Endosc ; 81(3): 749-55, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25484325

RESUMO

BACKGROUND: Diverticular disease is increasingly prevalent in Western societies and is associated with significant morbidity. OBJECTIVE: Two-stage endoscopic device development for inversion and secured ligation of colonic diverticula; first, human cadaver studies were performed to measure forces required for diverticular inversion; second, a novel set of devices (elastic spiked O-ring with delivery system) was tested in animals. DESIGN: Prospective, observational study of human cadavers and prospective, interventional study of a porcine model. SETTING: University hospital pathology laboratory and animal facility. INTERVENTION: Full-thickness inversion of the colonic wall with a pipelike delivery instrument to produce an inverted pseudodiverticulum that was secured with a spiked O-ring. MAIN OUTCOME MEASUREMENTS: The forces required for diverticular inversion, the secured closure of inverted pseudodiverticula, and the time until necrotic tissue falls off. RESULTS: A total of 248 of 248 of cadaveric sigmoid diverticula could be inverted by means of vacuum or forceps. The forces required for inversion ranged from 0.28 to 0.47 N (median, 0.37 N). Twenty-four spiked O-rings were delivered in 6 living pigs to produce 24 inverted pseudodiverticula. One animal died the day after the procedure of a pulmonary thromboembolism. In the remaining 5 pigs, all delivered spiked O-rings remained in place for 7 to 22 days. At necropsy, none of the inverted sites showed signs of perforation but rather full-thickness reparative scarring with ingrowth of connective tissue. LIMITATIONS: Animal model, stiff pipelike delivery instrument, variations in diverticular location, diameter, and size. CONCLUSIONS: Endoluminal inversion and securing of colonic diverticula induces tissue necrosis, diverticular sloughing, and full-thickness scarring.


Assuntos
Divertículo do Colo/cirurgia , Laparoscopia/métodos , Animais , Feminino , Humanos , Laparoscopia/instrumentação , Estudos Prospectivos , Suínos , Vácuo
15.
Artif Organs ; 39(1): E10-23, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25626584

RESUMO

Despite improvements in prosthetics and surgical techniques, the rate of complications following inguinal hernia repair remains high. Among these, discomfort and chronic pain have become a source of increasing concern among surgeons. Poor quality of tissue ingrowth, such as thin scar plates or shrinking scars-typical results with conventional static implants and plugs-may contribute to these adverse events. Recently, a new type of 3D dynamically responsive implant was introduced to the market. This device, designed to be placed fixation-free, seems to induce ingrowth of viable and structured tissue instead of regressive fibrotic scarring. To elucidate the differences in biologic response between the conventional static meshes and this 3D dynamically responsive implant, a histological comparison was planned. The aim of this study was to determine the quality of tissue incorporation in both types of implants excised after short, medium, and long periods post-implantation. The results showed large differences in the biologic responses between the two implant types. Histologically, the 3D dynamic implant showed development of tissue elements more similar to natural abdominal wall structures, such as the ingrowth of loose and well-hydrated connective tissue, well-formed vascular structures, elastic fibers, and mature nerves, with negligible or absent inflammatory response. All these characteristics were completely absent in the conventional static implants, where a persistent inflammatory reaction was associated with thin, hardened, and shrunken fibrotic scar formation. Consequently, as herniation is a degenerative process, the 3D dynamic implants, which induce regeneration of the typical groin components, seem to address its pathogenesis.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia/instrumentação , Teste de Materiais/métodos , Próteses e Implantes , Telas Cirúrgicas , Materiais Biocompatíveis , Hérnia Inguinal/diagnóstico , Herniorrafia/métodos , Humanos , Imageamento Tridimensional , Imuno-Histoquímica , Polipropilenos , Desenho de Prótese , Falha de Prótese , Estudos de Amostragem , Estatísticas não Paramétricas , Resistência à Tração , Fatores de Tempo
16.
Aging Clin Exp Res ; 26(1): 13-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23982787

RESUMO

Autophagy, a health-promoting lysosomal degradation pathway that controls the quality of the cytoplasm by eliminating protein aggregates and damaged organelles including 8-OHdG-rich mitochondria, is under investigation as a target for prevention and/or treatment of several human diseases and decelerating aging. Stimulation of autophagy was shown to rescue older liver cells from accumulation of 8-OHdG-rich mitochondria and to increase urinary 8-OHdG levels. Urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) is a recently recommended biomarker for monitoring oxidative status over time. In order to rule out the possibility that the in vivo stimulation of autophagy may cause an increase in the oxidative status, in this study we compared the effects of the stimulation of autophagy by two different procedures (the administration of antilipolytic drug and everolimus, an mTOR inhibitor in clinical use) on the urinary levels of 8-OHdG and 15-isoprostane F2t, another well-known biomarker of the oxidative status. Results show that both procedures increased the urinary 8-OHdG levels without any change in urinary 15-isoprostane F2t; this increase in urinary 8-OHdG levels after the antilipolytic drug was fully suppressed by the simultaneous injection of glucose to make rats transiently incompetent for the endocrine stimulation of autophagy. Conclusions are that the in vivo stimulation of autophagy does not affect the oxidative status and that the increasing effect on urinary 8-OHdG may be secondary to an increased degradation of previously accumulated 8-OHdG-rich (mt)DNA. The authors are aware that findings may open the way to a safe, easy, highly desirable non-invasive test for successful in vivo activation of autophagy after pharmacological stimulation.


Assuntos
Autofagia/fisiologia , Estresse Oxidativo/fisiologia , 8-Hidroxi-2'-Desoxiguanosina , Animais , Autofagia/efeitos dos fármacos , Biomarcadores/urina , Desoxiguanosina/análogos & derivados , Desoxiguanosina/urina , Dinoprosta/análogos & derivados , Glucose/farmacologia , Isoprostanos/urina , Masculino , Estresse Oxidativo/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley
17.
Surg Technol Int ; 24: 155-65, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24526424

RESUMO

Static solutions for highly motile structures such as the groin seem to represent a procedural incongruence. Another important issue in prosthetic hernia repair is related to the poor quality of tissue ingrowth within conventional flat meshes and plugs. These are all static, passive devices, and thus do not move in synchrony with the natural movements of the groin. In the literature there is a clear understanding of how conventional prostheses used for inguinal hernia repair are incorporated by rigid fibrotic tissue. The term "scar plate" well emphasizes this occurrence. The ingrowth of this kind of stiff fibrotic scar leads to mesh shrinkage and to the reduction of the mesh surface area. This is considered a significant cause of recurrence and discomfort. With this in mind, the need for a more physiologic procedure to further decrease complications and recurrences in inguinal hernia repair due to implant design seems obvious. This report shows how, by eliminating invasive fixation and improving the quality of tissue ingrowth within the implant, it is possible to reduce complications. To achieve these results, a new type of 3D dynamic (inherent recoil), self-retaining implant has been developed. This newly designed implant was previously implanted in the porcine model, showing excellent outcomes. Of note were the quality of tissue ingrowth and the near absence of shrinkage, even a long time after implantation. The present study describes the outcome of this device used in open inguinal hernia repair in 91 patients having direct and indirect inguinal hernia. In this patient cohort, evaluations were made for; operation length, intraoperative complications, late complications such as seroma, infection, chronic pain, and pain assessment through VAS score. Patient follow-up was made at 1 and 2 weeks, and 1, 3, 6, 12, and 36 months. Ultrasound scans were performed for the detection of any possible implant dislodgment, shrinkage, and implant incorporation. The results of this study demonstrate that by using a purposefully designed 30 geometric implant expulsion forces can be switched into gripping forces, avoiding the need for traumatic fixation. This eliminates the typical complications related to mesh fixation such as bleeding, hematoma, chronic pain, and tissue tearing, often resulting in mesh dislodgement and recurrence. This new 30 implant results in open hernia repair procedures being safer, faster, and easier.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia , Próteses e Implantes , Animais , Herniorrafia/efeitos adversos , Herniorrafia/instrumentação , Herniorrafia/métodos , Complicações Intraoperatórias , Desenho de Prótese , Suínos
18.
Surg Technol Int ; 25: 130-5, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25433343

RESUMO

The article reports the incidence of multiple inguinal protrusions in the same groin in a patient collect who underwent open hernia repair. Multiple ipsilateral inguinal hernias compose an almost neglected topic that, if not identified during hernia repair, could lead to unclear discomfort, pain, and reoperation. A collect of 100 consecutive open anterior inguinal hernia procedures was analyzed. The patients were divided into two subsets-A: patients with a single protrusion and B: patients with more than one protrusion simultaneously arising from the inguinal floor. The single hernias from cohort A and the multiple hernias from cohort B were further categorized using the Nyhus classification system. Eighty-eight single unilateral hernias were detected and 12 multiple inguinal hernias were ipsilaterally arising from the same groin. Nine percent of the multiple protrusions were double (three double indirect and six in combination direct + indirect). Three patients (3%) presented with triple protrusions; of those two individuals, one had a combination of double indirect, one had a direct hernia, and the third patient showed a tricomponent protrusion (hernia of the fossa supravescicalis + hernia of the fossa inguinalis media + indirect hernia). These numbers demonstrate that multiple ipsilateral inguinal hernias are more frequent than imagined. If undiscovered during a herniorrhaphy, the "forgotten" protrusion may generate unclear groin pain requiring reoperation. Consequently, is to envisage that many re-interventions will likely involve false "recurrences." Therefore, during hernia repair, more attention and adhesiolysis is essential during inspection of the inguinal floor. In fact, a careful exposure of the anatomical structures of the groin could be very advantageous in properly managing such conditions. This kind of surgical approach can help to prevent patient's discomfort and re-interventions.

19.
Sci Rep ; 14(1): 1372, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38228705

RESUMO

The laparoscopic approach represents the standard of treatment for renal and adrenal diseases, and its use is increasing even outside referral centres. Although most procedures are routinely performed, intraoperative complications do not occur, and the rate and predictive factors of these complications have not been established. The aim of this study was to evaluate the incidence and type of intraoperative complications and to identify predictive factors in patients undergoing laparoscopic renal and adrenal surgery. This was a cohort, multicentre, international retrospective study. Patients who underwent laparoscopic renal and adrenal surgeries between April 2017 and March 2022 were included in the study. Bivariate analysis was performed using contingency tables and the χ2 test for independent samples to compare qualitative variables and the T test and Mood test for continuous variables. Multivariate analysis was performed using a logistic regression model to obtain adjusted odds ratios. A total of 2374 patients were included in the study. Intraoperative complications were reported for 8.09% of patients who underwent renal surgery, with the most common complications reported being hollow viscus and vascular complications, and for 6.75% of patients who underwent adrenal surgery, with the most common complication reported being parenchymatous viscous complications. Multivariate analysis revealed that both adrenal and renal surgery radiological preoperative factors, such as invasive features during adrenalectomy and the RENAL score during nephrectomy, are predictive factors of intraoperative complications. In contrast to existing data, surgeon experience was not associated with a reduction in the incidence of perioperative complications.


Assuntos
Laparoscopia , Humanos , Estudos Retrospectivos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Adrenalectomia/efeitos adversos , Adrenalectomia/métodos , Nefrectomia/efeitos adversos , Nefrectomia/métodos , Complicações Intraoperatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
20.
J Clin Med ; 12(12)2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37373561

RESUMO

BACKGROUND: Compared to other types of abdominal protrusions, Spigelian hernias are not very common. In prosthetic repair of abdominal protrusions, mesh fixation and defect overlap are an open issue, as they are a source of complications. A newly developed tentacle-shaped mesh has been used to ensure a fixation-free repair with a broader defect overlap in the repair of abdominal hernias. This study describes the long-term results of a fixation-free repair of Spigelian hernias carried out with a tentacle mesh. METHODS: A proprietary mesh composed of a central body with integrated radiating arms was used for repairing Spigelian hernias in 54 patients. The implant was positioned in preperitoneal sublay, and the straps were delivered across the abdominal musculature with a needle passer, and then, after fascia closure, cut short in the subcutaneous layer. RESULTS: The friction of the straps passing through the abdominal wall served to hold the mesh in place, guaranteeing a wide overlap over the defect without fixation. In a long-term follow-up of 6 to 84 months (mean 64 months), a very low rate of complications occurred, but no recurrence was reported. CONCLUSIONS: The tentacle strap system of the prosthesis allowed for an easy, fast and safe fixation-free placement granting a wide overlap, avoiding intraoperative complications. Greatly reduced pain and a negligible amount of postoperative complications characterized the postoperative outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA