Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 149
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 59(3): 1010-1020, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37259967

RESUMO

BACKGROUND: 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) is valuable for determining presence of viable tumor, but is limited by geographical restrictions, radiation exposure, and high cost. PURPOSE: To generate diagnostic-quality PET equivalent imaging for patients with brain neoplasms by deep learning with multi-contrast MRI. STUDY TYPE: Retrospective. SUBJECTS: Patients (59 studies from 51 subjects; age 56 ± 13 years; 29 males) who underwent 18 F-FDG PET and MRI for determining recurrent brain tumor. FIELD STRENGTH/SEQUENCE: 3T; 3D GRE T1, 3D GRE T1c, 3D FSE T2-FLAIR, and 3D FSE ASL, 18 F-FDG PET imaging. ASSESSMENT: Convolutional neural networks were trained using four MRIs as inputs and acquired FDG PET images as output. The agreement between the acquired and synthesized PET was evaluated by quality metrics and Bland-Altman plots for standardized uptake value ratio. Three physicians scored image quality on a 5-point scale, with score ≥3 as high-quality. They assessed the lesions on a 5-point scale, which was binarized to analyze diagnostic consistency of the synthesized PET compared to the acquired PET. STATISTICAL TESTS: The agreement in ratings between the acquired and synthesized PET were tested with Gwet's AC and exact Bowker test of symmetry. Agreement of the readers was assessed by Gwet's AC. P = 0.05 was used as the cutoff for statistical significance. RESULTS: The synthesized PET visually resembled the acquired PET and showed significant improvement in quality metrics (+21.7% on PSNR, +22.2% on SSIM, -31.8% on RSME) compared with ASL. A total of 49.7% of the synthesized PET were considered as high-quality compared to 73.4% of the acquired PET which was statistically significant, but with distinct variability between readers. For the positive/negative lesion assessment, the synthesized PET had an accuracy of 87% but had a tendency to overcall. CONCLUSION: The proposed deep learning model has the potential of synthesizing diagnostic quality FDG PET images without the use of radiotracers. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Fluordesoxiglucose F18 , Estudos Retrospectivos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos
2.
Eur Radiol ; 34(2): 1137-1145, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37615768

RESUMO

OBJECTIVE: To assess the safety and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) for the treatment extra-abdominal desmoids. METHODS: A total of 105 patients with desmoid fibromatosis (79 females, 26 males; 35 ± 14 years) were treated with MRgFUS between 2011 and 2021 in three centers. Total and viable tumors were evaluated per patient at last follow-up after treatment. Response and progression-free survival (PFS) were assessed with (modified) response evaluation criteria in solid tumors (RECIST v.1.1 and mRECIST). Change in Numerical Rating Scale (NRS) pain and 36-item Short Form Health Survey (SF-36) scores were compared. Treatment-related adverse events were recorded. RESULTS: The median initial tumor volume was 114 mL (IQR 314 mL). After MRgFUS, median total and viable tumor volume decreased to 51 mL (95% CI: 30-71 mL, n = 101, p < 0.0001) and 29 mL (95% CI: 17-57 mL, n = 88, p < 0.0001), respectively, at last follow-up (median: 15 months, 95% CI: 11-20 months). Based on total tumor measurements (RECIST), 86% (95% CI: 75-93%) had at least stable disease or better at last follow-up, but 50% (95% CI: 38-62%) of remaining viable nodules (mRECIST) progressed within the tumor. Median PFS was reached at 17 and 13 months for total and viable tumors, respectively. NRS decreased from 6 (IQR 3) to 3 (IQR 4) (p < 0.001). SF-36 scores improved (physical health (41 (IQR 15) to 46 (IQR 12); p = 0.05, and mental health (49 (IQR 17) to 53 (IQR 9); p = 0.02)). Complications occurred in 36%, most commonly 1st/2nd degree skin burns. CONCLUSION: MRgFUS reduced tumor volume, reduced pain, and improved quality of life in this series of 105 patients with extra-abdominal desmoid fibromatosis. CLINICAL RELEVANCE STATEMENT: Imaging-guided ablation is being increasingly used as an alternative to surgery, radiation, and medical therapy for the treatment of desmoid fibromatosis. MR-guided high-intensity focused ultrasound is an incisionless ablation technique that can be used to reduce tumor burden effectively and safely. KEY POINTS: • Desmoid fibromatosis was treated with MR-guided high-intensity focused ultrasound in 105 patients. • MR-guided focused ultrasound ablation reduced tumor volume and pain and improved quality of life. • MR-guided focused ultrasound is a treatment option for patients with extra-abdominal desmoid tumors.


Assuntos
Fibromatose Agressiva , Ablação por Ultrassom Focalizado de Alta Intensidade , Humanos , Masculino , Feminino , Fibromatose Agressiva/diagnóstico por imagem , Fibromatose Agressiva/terapia , Fibromatose Agressiva/patologia , Estudos Retrospectivos , Qualidade de Vida , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Dor , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-38968327

RESUMO

OBJECTIVE: To evaluate the effect of volumetric analysis on the diagnosis and management of indeterminate solid pulmonary nodules in routine clinical practice. METHODS: This was a retrospective study with 107 computed tomography (CT) cases of solid pulmonary nodules (range, 6-15 mm), 57 pathology-proven malignancies (lung cancer, n = 34; metastasis, n = 23), and 50 benign nodules. Nodules were evaluated on a total of 309 CT scans (average number of CTs/nodule, 2.9 [range, 2-7]). CT scans were from multiple institutions with variable technique. Nine radiologists (attendings, n = 3; fellows, n = 3; residents, n = 3) were asked their level of suspicion for malignancy (low/moderate or high) and management recommendation (no follow-up, CT follow-up, or care escalation) for baseline and follow-up studies first without and then with volumetric analysis data. Effect of volumetry on diagnosis and management was assessed by generalized linear and logistic regression models. RESULTS: Volumetric analysis improved sensitivity (P = 0.009) and allowed earlier recognition (P < 0.05) of malignant nodules. Attending radiologists showed higher sensitivity in recognition of malignant nodules (P = 0.03) and recommendation of care escalation (P < 0.001) compared with trainees. Volumetric analysis altered management of high suspicion nodules only in the fellow group (P = 0.008). κ Statistics for suspicion for malignancy and recommended management were fair to substantial (0.38-0.66) and fair to moderate (0.33-0.50). Volumetric analysis improved interobserver variability for identification of nodule malignancy from 0.52 to 0.66 (P = 0.004) only on the second follow-up study. CONCLUSIONS: Volumetric analysis of indeterminate solid pulmonary nodules in routine clinical practice can result in improved sensitivity and earlier identification of malignant nodules. The effect of volumetric analysis on management recommendations is variable and influenced by reader experience.

4.
Neuroimage ; 280: 120312, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37574120

RESUMO

Activity-dependent myelination is a fundamental mode of brain plasticity which significantly influences network function. We recently discovered that absence seizures, which occur in multiple forms of generalized epilepsy, can induce activity-dependent myelination, which in turn promotes further progression of epilepsy. Structural alterations of myelin are likely to be widespread, given that absence seizures arise from an extensive thalamocortical network involving frontoparietal regions of the bilateral hemispheres. However, the temporal course and spatial extent of myelin plasticity is unknown, due to limitations of gold-standard histological methods such as electron microscopy (EM). In this study, we leveraged magnetization transfer and diffusion MRI for estimation of g-ratios across major white matter tracts in a mouse model of generalized epilepsy with progressive absence seizures. EM was performed on the same brains after MRI. After seizure progression, we found increased myelination (decreased g-ratios) throughout the anterior portion (genu-to-body) of the corpus callosum but not in the posterior portion (body-splenium) nor in the fornix or the internal capsule. Curves obtained from averaging g-ratio values at every longitudinal point of the corpus callosum were statistically different with p<0.001. Seizure-associated myelin differences found in the corpus callosum body with MRI were statistically significant (p = 0.0027) and were concordant with EM in the same region (p = 0.01). Notably, these differences were not detected by diffusion tensor imaging. This study reveals widespread myelin structural change that is specific to the absence seizure network. Furthermore, our findings demonstrate the potential utility and importance of MRI-based g-ratio estimation to non-invasively detect myelin plasticity.


Assuntos
Imagem de Tensor de Difusão , Epilepsia Generalizada , Animais , Camundongos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Corpo Caloso/patologia , Convulsões/diagnóstico por imagem
5.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36583628

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Humanos , Feminino , Estudos Prospectivos , Decúbito Ventral , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar/métodos
6.
Radiology ; 303(3): 620-631, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35191738

RESUMO

Background The PET tracer (4S)-4-(3-[18F]fluoropropyl)-l-glutamate (18F-FSPG) targets the system xC- cotransporter, which is overexpressed in various tumors. Purpose To assess the role of 18F-FSPG PET/CT in intracranial malignancies. Materials and Methods Twenty-six patients (mean age, 54 years ± 12; 17 men; 48 total lesions) with primary brain tumors (n = 17) or brain metastases (n = 9) were enrolled in this prospective, single-center study (ClinicalTrials.gov identifier: NCT02370563) between November 2014 and March 2016. A 30-minute dynamic brain 18F-FSPG PET/CT scan and a static whole-body (WB) 18F-FSPG PET/CT scan at 60-75 minutes were acquired. Moreover, all participants underwent MRI, and four participants underwent fluorine 18 (18F) fluorodeoxyglucose (FDG) PET imaging. PET parameters and their relative changes were obtained for all lesions. Kinetic modeling was used to estimate the 18F-FSPG tumor rate constants using the dynamic and dynamic plus WB PET data. Imaging parameters were correlated to lesion outcomes, as determined with follow-up MRI and/or pathologic examination. The Mann-Whitney U test or Student t test was used for group mean comparisons. Receiver operating characteristic curve analysis was used for performance comparison of different decision measures. Results 18F-FSPG PET/CT helped identify all 48 brain lesions. The mean tumor-to-background ratio (TBR) on the whole-brain PET images at the WB time point was 26.6 ± 24.9 (range: 2.6-150.3). When 18F-FDG PET was performed, 18F-FSPG permitted visualization of non-18F-FDG-avid lesions or allowed better lesion differentiation from surrounding tissues. In participants with primary brain tumors, the predictive accuracy of the relative changes in influx rate constant Ki and maximum standardized uptake value to discriminate between poor and good lesion outcomes were 89% and 81%, respectively. There were significant differences in the 18F-FSPG uptake curves of lesions with good versus poor outcomes in the primary brain tumor group (P < .05) but not in the brain metastases group. Conclusion PET/CT imaging with (4S)-4-(3-[18F]fluoropropyl)-l-glutamate (18F-FSPG) helped detect primary brain tumors and brain metastases with a high tumor-to-background ratio. Relative changes in 18F-FSPG uptake with multi-time-point PET appear to be helpful in predicting lesion outcomes. Clinical trial registration no. NCT02370563 © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Neoplasias Encefálicas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias Encefálicas/diagnóstico por imagem , Fluordesoxiglucose F18 , Ácido Glutâmico , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos
7.
Eur J Nucl Med Mol Imaging ; 50(1): 184-193, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34729628

RESUMO

PURPOSE: A novel cystine-knot peptide-based PET radiopharmaceutical, 18F-FP-R01-MG-F2 (knottin), was developed to selectively bind to human integrin αvß6 which is overexpressed in pancreatic cancer. The purpose of this study is to evaluate the safety, biodistribution, dosimetry, and lesion uptake of 18F-FP-R01-MG-F2 in patients with pancreatic cancer. METHODS: Fifteen patients (6 men, 9 women) with histologically confirmed pancreatic cancer were prospectively enrolled and underwent knottin PET/CT between March 2017 and February 2021 (ClinicalTrials.gov Identifier NCT02683824). Vital signs and laboratory results were collected before and after the imaging scans. Maximum standardized uptake values (SUVmax) and mean SUV (SUVmean) were measured in 24 normal tissues and pancreatic cancer lesions for each patient. From the biodistribution data, the organ doses and whole-body effective dose were calculated using OLINDA/EXM software. RESULTS: There were no significant changes in vital signs or laboratory values that qualified as adverse events or serious adverse events. At 1 h post-injection, areas of high 18F-FP-R01-MG-F2 uptake included the pituitary gland, stomach, duodenum, kidneys, and bladder (average SUVmean: 9.7-14.5). Intermediate uptake was found in the normal pancreas (average SUVmean: 4.5). Mild uptake was found in the lungs and liver (average SUVmean < 1.0). The effective dose was calculated to be 2.538 × 10-2 mSv/MBq. Knottin PET/CT detected all known pancreatic tumors in the 15 patients, although it did not detect small peri-pancreatic lymph nodes of less than 1 cm in short diameter in two of three patients who had lymph node metastases at surgery. Knottin PET/CT detected distant metastases in the lungs (n = 5), liver (n = 4), and peritoneum (n = 2), confirmed by biopsy and/or contrast-enhanced CT. CONCLUSION: 18F-FP-R01-MG-F2 is a safe PET radiopharmaceutical with an effective dose comparable to other diagnostic agents. Evaluation of the primary pancreatic cancer and distant metastases with 18F-FP-R01-MG-F2 PET is feasible, but larger studies are required to define the role of this approach. TRIAL REGISTRATION: NCT02683824.


Assuntos
Miniproteínas Nó de Cistina , Neoplasias Pancreáticas , Feminino , Humanos , Masculino , Cistina/metabolismo , Miniproteínas Nó de Cistina/metabolismo , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/metabolismo , Peptídeos/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Distribuição Tecidual , Neoplasias Pancreáticas
8.
AJR Am J Roentgenol ; 218(6): 1102-1103, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35043665

RESUMO

As of January 2021, among other transparency requirements, the Centers for Medicare & Medicaid Services require that hospitals publish consumer-friendly displays of charges for shoppable health care services, including four musculoskeletal imaging examinations. Of 250 selected U.S. hospitals, all published charges for these four examinations, although 21% did not provide charges within consumer-friendly displays. Bed count was larger for compliant hospitals than for noncompliant hospitals (500 vs 384 beds). All four examinations had widely variable charges (representing a 73.8-fold difference).


Assuntos
Hospitais , Medicare , Idoso , Centers for Medicare and Medicaid Services, U.S. , Humanos , Estados Unidos
9.
Skeletal Radiol ; 51(3): 549-556, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34223946

RESUMO

OBJECTIVE: To compare the diagnostic performance of a conventional metal artifact suppression sequence MAVRIC-SL (multi-acquisition variable-resonance image combination selective) and a novel 2.6-fold faster sequence employing robust principal component analysis (RPCA), in the MR evaluation of hip implants at 3 T. MATERIALS AND METHODS: Thirty-six total hip implants in 25 patients were scanned at 3 T using a conventional MAVRIC-SL proton density-weighted sequence and an RPCA MAVRIC-SL proton density-weighted sequence. Comparison was made of image quality, geometric distortion, visualization around acetabular and femoral components, and conspicuity of abnormal imaging findings using the Wilcoxon signed-rank test and a non-inferiority test. Abnormal findings were correlated with subsequent clinical management and intraoperative findings if the patient underwent subsequent surgery. RESULTS: Mean scores for conventional MAVRIC-SL were better than RPCA MAVRIC-SL for all qualitative parameters (p < 0.05), although the probability of RPCA MAVRIC-SL being clinically useful was non-inferior to conventional MAVRIC-SL (within our accepted 10% difference, p < 0.05), except for visualization around the acetabular component. Abnormal imaging findings were seen in 25 hips, and either equally visible or visible but less conspicuous on RPCA MAVRIC-SL in 21 out of 25 cases. In 4 cases, a small joint effusion was queried on MAVRIC-SL but not RPCA MAVRIC-SL, but the presence or absence of a small effusion did not affect subsequent clinical management and patient outcome. CONCLUSION: While the overall image quality is reduced, RPCA MAVRIC-SL allows for significantly reduced scan time and maintains almost equal diagnostic performance.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artefatos , Humanos , Imageamento por Ressonância Magnética , Próteses e Implantes
10.
J Magn Reson Imaging ; 53(5): 1594-1605, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33382171

RESUMO

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos
11.
J Magn Reson Imaging ; 53(3): 807-817, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33067849

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE: To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE: Prospective. POPULATION: A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES: Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT: Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS: Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS: MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION: Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
Pediatr Radiol ; 51(9): 1654-1666, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33772640

RESUMO

BACKGROUND: Neonatal/infantile jaundice is relatively common, and most cases resolve spontaneously. However, in the setting of unresolved neonatal cholestasis, a prompt and accurate assessment for biliary atresia is vital to prevent poor outcomes. OBJECTIVE: To determine whether shear wave elastography (SWE) alone or combined with gray-scale imaging improves the diagnostic performance of US in discriminating biliary atresia from other causes of neonatal jaundice over that of gray-scale imaging alone. MATERIALS AND METHODS: Infants referred for cholestatic jaundice were assessed with SWE and gray-scale US. On gray-scale US, two radiology readers assessed liver heterogeneity, presence of the triangular cord sign, hepatic artery size, presence/absence of common bile duct and gallbladder, and gallbladder shape; associated interobserver correlation coefficients (ICC) were calculated. SWE speeds were performed on a Siemens S3000 using 6C2 and 9 L4 transducers with both point and two-dimensional (2-D) SWE US. Both univariable and multivariable analyses were performed, as were receiver operating characteristic curves (ROC) and statistical significance tests (chi-squared, analysis of variance, t-test and Wilcoxon rank sum) when appropriate. RESULTS: There were 212 infants with biliary atresia and 106 without biliary atresia. The median shear wave speed (SWS) for biliary atresia cases was significantly higher (P<0.001) than for non-biliary-atresia cases for all acquisition modes. For reference, the median L9 point SWS was 2.1 m/s (interquartile range [IQR] 1.7-2.4 m/s) in infants with biliary atresia and 1.5 m/s (IQR 1.3-1.9 m/s) in infants without biliary atresia (P<0.001). All gray-scale US findings were significantly different between biliary-atresia and non-biliary-atresia cohorts (P<0.001), intraclass correlation coefficient (ICC) range 0.7-1.0. Triangular cord sign was most predictive of biliary atresia independent of other gray-scale findings or SWS - 96% specific and 88% sensitive. Multistep univariable/multivariable analysis of both gray-scale findings and SWE resulted in three groups being predictive of biliary atresia likelihood. Abnormal common bile duct/gallbladder and enlarged hepatic artery were highly predictive of biliary atresia independent of SWS (100% for girls and 95-100% for boys). Presence of both the common bile duct and the gallbladder along with a normal hepatic artery usually excluded biliary atresia independent of SWS. Other gray-scale combinations were equivocal, and including SWE improved discrimination between biliary-atresia and non-biliary-atresia cases. CONCLUSION: Shear wave elastography independent of gray-scale US significantly differentiated biliary-atresia from non-biliary-atresia cases. However, gray-scale findings were more predictive of biliary atresia than elastography. SWE was useful for differentiating biliary-atresia from non-biliary-atresia cases in the setting of equivocal gray-scale findings.


Assuntos
Atresia Biliar , Colestase , Técnicas de Imagem por Elasticidade , Icterícia Neonatal , Atresia Biliar/diagnóstico por imagem , Feminino , Humanos , Lactente , Recém-Nascido , Icterícia Neonatal/diagnóstico por imagem , Masculino , Ultrassonografia
13.
J Appl Clin Med Phys ; 22(6): 183-190, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33949078

RESUMO

We describe the creation and characterization of a calibration CT mini-lung-phantom incorporating simulated airways and ground-glass densities. Ten duplicate mini-lung-phantoms with Three-Dimensional (3-D) printed tubes simulating airways and gradated density polyurethane foam blocks were designed and built. Dimensional accuracy and CT numbers were measured using micro-CT and clinical CT scanners. Micro-CT images of airway tubes demonstrated an average dimensional variation of 0.038 mm from nominal values. The five different densities of incorporated foam blocks, simulating ground-glass, showed mean CT numbers (±standard deviation) of -897.0 ± 1.5, -844.1 ± 1.5, -774.1 ± 2.6, -695.3 ± 1.6, and -351.0 ± 3.7 HU, respectively. Three-Dimensional printing and subtractive manufacturing enabled rapid, cost-effective production of ground-truth calibration mini-lung-phantoms with low inter-sample variation that can be scanned simultaneously with the patient undergoing lung quantitative CT.


Assuntos
Impressão Tridimensional , Tomografia Computadorizada por Raios X , Calibragem , Humanos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas
14.
Neuroimage ; 220: 117136, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-32634594

RESUMO

Oxygen extraction fraction (OEF) and the cerebral metabolic rate of oxygen (CMRO2) are key cerebral physiological parameters to identify at-risk cerebrovascular patients and understand brain health and function. PET imaging with [15O]-oxygen tracers, either through continuous or bolus inhalation, provides non-invasive assessment of OEF and CMRO2. Numerous tracer delivery, PET acquisition, and kinetic modeling approaches have been adopted to map brain oxygenation. The purpose of this technical review is to critically evaluate different methods for [15O]-gas PET and its impact on the accuracy and reproducibility of OEF and CMRO2 measurements. We perform a meta-analysis of brain oxygenation PET studies in healthy volunteers and compare between continuous and bolus inhalation techniques. We also describe OEF metrics that have been used to detect hemodynamic impairment in cerebrovascular disease. For these patients, advanced techniques to accelerate the PET scans and potential synthesis with MRI to avoid arterial blood sampling would facilitate broader use of [15O]-oxygen PET for brain physiological assessment.


Assuntos
Encéfalo/metabolismo , Consumo de Oxigênio/fisiologia , Oxigênio/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem , Humanos
15.
Neuroimage ; 217: 116864, 2020 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-32360690

RESUMO

Collegiate football athletes are subject to repeated head impacts. The purpose of this study was to determine whether this exposure can lead to changes in brain structure. This prospective cohort study was conducted with up to 4 years of follow-up on 63 football (high-impact) and 34 volleyball (control) male collegiate athletes with a total of 315 MRI scans (after exclusions: football n â€‹= â€‹50, volleyball n â€‹= â€‹24, total scans â€‹= â€‹273) using high-resolution structural imaging. Volumetric and cortical thickness estimates were derived using FreeSurfer 5.3's longitudinal pipeline. A linear mixed-effects model assessed the effect of group (football vs. volleyball), time from baseline MRI, and the interaction between group and time. We confirmed an expected developmental decrement in cortical thickness and volume in our cohort (p â€‹< â€‹.001). Superimposed on this, total cortical gray matter volume (p â€‹= â€‹.03) and cortical thickness within the left hemisphere (p â€‹= â€‹.04) showed a group by time interaction, indicating less age-related volume reduction and thinning in football compared to volleyball athletes. At the regional level, sport by time interactions on thickness and volume were identified in the left orbitofrontal (p â€‹= â€‹.001), superior temporal (p â€‹= â€‹.001), and postcentral regions (p â€‹< â€‹.001). Additional cortical thickness interactions were found in the left temporal pole (p â€‹= â€‹.003) and cuneus (p â€‹= â€‹.005). At the regional level, we also found main effects of sport in football athletes characterized by reduced volume in the right hippocampus (p â€‹= â€‹.003), right superior parietal cortical gray (p â€‹< â€‹.001) and white matter (p â€‹< â€‹.001), and increased volume of the left pallidum (p â€‹= â€‹.002). Within football, cortical thickness was higher with greater years of prior play (left hemisphere p â€‹= â€‹.013, right hemisphere p â€‹= â€‹.005), and any history of concussion was associated with less cortical thinning (left hemisphere p â€‹= â€‹.010, right hemisphere p â€‹= â€‹.011). Additionally, both position-associated concussion risk (p â€‹= â€‹.002) and SCAT scores (p â€‹= â€‹.023) were associated with less of the expected volume decrement of deep gray structures. This prospective longitudinal study comparing football and volleyball athletes shows divergent age-related trajectories of cortical thinning, possibly reflecting an impact-related alteration of normal cortical development. This warrants future research into the underlying mechanisms of impacts to the head on cortical maturation.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/lesões , Futebol Americano/lesões , Adolescente , Adulto , Atletas , Encéfalo/diagnóstico por imagem , Concussão Encefálica/diagnóstico por imagem , Estudos de Coortes , Lateralidade Funcional , Substância Cinzenta/diagnóstico por imagem , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Voleibol/lesões , Adulto Jovem
16.
Radiology ; 297(2): 438-446, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32930651

RESUMO

Background Iron oxide nanoparticles are an alternative contrast agent for MRI. Gadolinium deposition has raised safety concerns, but it is unknown whether ferumoxytol administration also deposits in the brain. Purpose To investigate whether there are signal intensity changes in the brain at multiecho gradient imaging following ferumoxytol exposure in children and young adults. Materials and Methods This retrospective case-control study included children and young adults, matched for age and sex, with brain arteriovenous malformations who received at least one dose of ferumoxytol from January 2014 to January 2018. In participants who underwent at least two brain MRI examinations (subgroup), the first and last available examinations were analyzed. Regions of interests were placed around deep gray structures on quantitative susceptibility mapping and R2* images. Mean susceptibility and R2* values of regions of interests were recorded. Measurements were assessed by linear regression analyses: a between-group comparison of ferumoxytol-exposed and unexposed participants and a within-group (subgroup) comparison before and after exposure. Results Seventeen participants (mean age ± standard deviation, 13 years ± 5; nine male) were in the ferumoxytol-exposed (case) group, 21 (mean age, 14 years ± 5; 11 male) were in the control group, and nine (mean age, 12 years ± 6; four male) were in the subgroup. The mean number of ferumoxytol administrations was 2 ± 1 (range, one to four). Mean susceptibility (in parts per million [ppm]) and R2* (in inverse seconds [sec-1]) values of the dentate (case participants: 0.06 ppm ± 0.04 and 23.87 sec-1 ± 4.13; control participants: 0.02 ppm ± 0.03 and 21.7 sec-1 ± 5.26), substantia nigrae (case participants: 0.08 ppm ± 0.06 and 27.46 sec-1 ± 5.58; control participants: 0.04 ppm ± 0.05 and 24.96 sec-1 ± 5.3), globus pallidi (case participants: 0.14 ppm ± 0.05 and 30.75 sec-1 ± 5.14; control participants: 0.08 ppm ± 0.07 and 28.82 sec-1 ± 6.62), putamina (case participants: 0.03 ppm ± 0.02 and 20.63 sec-1 ± 2.44; control participants: 0.02 ppm ± 0.02 and 19.65 sec-1 ± 3.6), caudate (case participants: -0.1 ppm ± 0.04 and 18.21 sec-1 ± 3.1; control participants: -0.06 ppm ± 0.05 and 18.83 sec-1 ± 3.32), and thalami (case participants: 0 ppm ± 0.03 and 16.49 sec-1 ± 3.6; control participants: 0.02 ppm ± 0.02 and 18.38 sec-1 ± 2.09) did not differ between groups (susceptibility, P = .21; R2*, P = .24). For the subgroup, the mean interval between the first and last ferumoxytol administration was 14 months ± 8 (range, 1-25 months). Mean susceptibility and R2* values of the dentate (first MRI: 0.06 ppm ± 0.05 and 25.78 sec-1 ± 5.9; last MRI: 0.06 ppm ± 0.02 and 25.55 sec-1 ± 4.71), substantia nigrae (first MRI: 0.06 ppm ± 0.06 and 28.26 sec-1 ± 9.56; last MRI: 0.07 ppm ± 0.06 and 25.65 sec-1 ± 6.37), globus pallidi (first MRI: 0.13 ppm ± 0.07 and 27.53 sec-1 ± 8.88; last MRI: 0.14 ppm ± 0.06 and 29.78 sec-1 ± 6.54), putamina (first MRI: 0.03 ppm ± 0.03 and 19.78 sec-1 ± 3.51; last MRI: 0.03 ppm ± 0.02 and 19.73 sec-1 ± 3.01), caudate (first MRI: -0.09 ppm ± 0.05 and 21.38 sec-1 ± 4.72; last MRI: -0.1 ppm ± 0.05 and 18.75 sec-1 ± 2.68), and thalami (first MRI: 0.01 ppm ± 0.02 and 17.65 sec-1 ± 5.16; last MRI: 0 ppm ± 0.02 and 15.32 sec-1 ± 2.49) did not differ between the first and last MRI examinations (susceptibility, P = .95; R2*, P = .54). Conclusion No overall significant differences were found in susceptibility and R2* values of deep gray structures to suggest retained iron in the brain between ferumoxytol-exposed and unexposed children and young adults with arteriovenous malformations and in those exposed to ferumoxytol over time. © RSNA, 2020.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Encéfalo/metabolismo , Meios de Contraste/administração & dosagem , Óxido Ferroso-Férrico/administração & dosagem , Ferro/metabolismo , Imageamento por Ressonância Magnética/métodos , Adolescente , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Estudos Retrospectivos , Adulto Jovem
17.
Radiology ; 296(1): 143-151, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32368961

RESUMO

Background Whole-body diffusion-weighted (DW) MRI can help detect cancer with high sensitivity. However, the assessment of therapy response often requires information about tumor metabolism, which is measured with fluorine 18 fluorodeoxyglucose (FDG) PET. Purpose To compare tumor therapy response with whole-body DW MRI and FDG PET/MRI in children and young adults. Materials and Methods In this prospective, nonrandomized multicenter study, 56 children and young adults (31 male and 25 female participants; mean age, 15 years ± 4 [standard deviation]; age range, 6-22 years) with lymphoma or sarcoma underwent 112 simultaneous whole-body DW MRI and FDG PET/MRI between June 2015 and December 2018 before and after induction chemotherapy (ClinicalTrials.gov identifier: NCT01542879). The authors measured minimum tumor apparent diffusion coefficients (ADCs) and maximum standardized uptake value (SUV) of up to six target lesions and assessed therapy response after induction chemotherapy according to the Lugano classification or PET Response Criteria in Solid Tumors. The authors evaluated agreements between whole-body DW MRI- and FDG PET/MRI-based response classifications with Krippendorff α statistics. Differences in minimum ADC and maximum SUV between responders and nonresponders and comparison of timing for discordant and concordant response assessments after induction chemotherapy were evaluated with the Wilcoxon test. Results Good agreement existed between treatment response assessments after induction chemotherapy with whole-body DW MRI and FDG PET/MRI (α = 0.88). Clinical response prediction according to maximum SUV (area under the receiver operating characteristic curve = 100%; 95% confidence interval [CI]: 99%, 100%) and minimum ADC (area under the receiver operating characteristic curve = 98%; 95% CI: 94%, 100%) were similar (P = .37). Sensitivity and specificity were 96% (54 of 56 participants; 95% CI: 86%, 99%) and 100% (56 of 56 participants; 95% CI: 54%, 100%), respectively, for DW MRI and 100% (56 of 56 participants; 95% CI: 93%, 100%) and 100% (56 of 56 participants; 95% CI: 54%, 100%) for FDG PET/MRI. In eight of 56 patients who underwent imaging after induction chemotherapy in the early posttreatment phase, chemotherapy-induced changes in tumor metabolism preceded changes in proton diffusion (P = .002). Conclusion Whole-body diffusion-weighted MRI showed significant agreement with fluorine 18 fluorodeoxyglucose PET/MRI for treatment response assessment in children and young adults. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Adolescente , Adulto , Criança , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Masculino , Imagem Multimodal/métodos , Pediatria/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem
18.
Magn Reson Med ; 84(3): 1661-1671, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32077521

RESUMO

PURPOSE: Motion artifact limits the clinical translation of high-field MR. We present an optical prospective motion correction system for 7 Tesla MRI using a custom-built, within-coil camera to track an optical marker mounted on a subject. METHODS: The camera was constructed to fit between the transmit-receive coils with direct line of sight to a forehead-mounted marker, improving upon prior mouthpiece work at 7 Tesla MRI. We validated the system by acquiring a 3D-IR-FSPGR on a phantom with deliberate motion applied. The same 3D-IR-FSPGR and a 2D gradient echo were then acquired on 7 volunteers, with/without deliberate motion and with/without motion correction. Three neuroradiologists blindly assessed image quality. In 1 subject, an ultrahigh-resolution 2D gradient echo with 4 averages was acquired with motion correction. Four single-average acquisitions were then acquired serially, with the subject allowed to move between acquisitions. A fifth single-average 2D gradient echo was acquired following subject removal and reentry. RESULTS: In both the phantom and human subjects, deliberate and involuntary motion were well corrected. Despite marked levels of motion, high-quality images were produced without spurious artifacts. The quantitative ratings confirmed significant improvements in image quality in the absence and presence of deliberate motion across both acquisitions (P < .001). The system enabled ultrahigh-resolution visualization of the hippocampus during a long scan and robust alignment of serially acquired scans with interspersed movement. CONCLUSION: We demonstrate the use of a within-coil camera to perform optical prospective motion correction and ultrahigh-resolution imaging at 7 Tesla MRI. The setup does not require a mouthpiece, which could improve accessibility of motion correction during 7 Tesla MRI exams.


Assuntos
Artefatos , Encéfalo , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Neuroimagem , Estudos Prospectivos
19.
Eur J Nucl Med Mol Imaging ; 47(12): 2787-2795, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32296882

RESUMO

PURPOSE: The purpose of this study was to investigate the prognostic value of whole-body metabolic tumor volume (MTV) and other metabolic tumor parameters, obtained from baseline and first restaging 18F-FDG PET/CT scans in melanoma patients treated with immune checkpoint inhibitors (ICIs). METHODS: Eighty-five consecutive melanoma patients (M, 57; F, 28) treated with ICIs who underwent PET/CT scans before and approximately 3 months after the start of immunotherapy were retrospectively enrolled. Metabolic tumor parameters including MTV for all melanoma lesions were measured on each scan. A Cox proportional hazards model was used for univariate and multivariate analyses of metabolic parameters combined with known clinical prognostic factors associated with overall survival (OS). Kaplan-Meier curves for patients dichotomized based on median values of imaging parameters were generated. RESULTS: The median OS time in all patients was 45 months (95% CI 24-45 months). Univariate analysis demonstrated that MTV obtained from first restaging PET/CT scans (MTVpost) was the strongest prognostic factor for OS among PET/CT parameters (P < 0.0001). The median OS in patients with high MTVpost (≥ 23.44) was 16 months (95% CI 12-32 months) as compared with more than 60 months in patients with low MTVpost (< 23.44) (P = 0.0003). A multivariate model including PET/CT parameters and known clinical prognostic factors revealed that MTVpost and the presence of central nervous system lesions were independent prognostic factors for OS (P = 0.0004, 0.0167, respectively). One pseudoprogression case (1.2%) was seen in this population and classified into the high MTVpost group. CONCLUSION: Whole-body metabolic tumor volume from PET scan acquired approximately 3 months following initiation of immunotherapy (MTVpost) is a strong prognostic indicator of OS in melanoma patients. Although the possibility of pseudoprogression must be considered whenever evaluating first restaging PET imaging, it only occurred in 1 patient in our cohort.


Assuntos
Melanoma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Humanos , Imunoterapia , Melanoma/diagnóstico por imagem , Melanoma/tratamento farmacológico , Prognóstico , Estudos Retrospectivos , Carga Tumoral
20.
Stroke ; 50(12): 3408-3415, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31619150

RESUMO

Background and Purpose- Imaging is frequently used to select acute stroke patients for intra-arterial therapy. Quantitative cerebral blood flow can be measured noninvasively with arterial spin labeling magnetic resonance imaging. Cerebral blood flow levels in the contralateral (unaffected) hemisphere may affect capacity for collateral flow and patient outcome. The goal of this study was to determine whether higher contralateral cerebral blood flow (cCBF) in acute stroke identifies patients with better 90-day functional outcome. Methods- Patients were part of the prospective, multicenter iCAS study (Imaging Collaterals in Acute Stroke) between 2013 and 2017. Consecutive patients were enrolled after being diagnosed with anterior circulation acute ischemic stroke. Inclusion criteria were ischemic anterior circulation stroke, baseline National Institutes of Health Stroke Scale score ≥1, prestroke modified Rankin Scale score ≤2, onset-to-imaging time <24 hours, with imaging including diffusion-weighted imaging and arterial spin labeling. Patients were dichotomized into high and low cCBF groups based on median cCBF. Outcomes were assessed by day-1 and day-5 National Institutes of Health Stroke Scale; and day-30 and day-90 modified Rankin Scale. Multivariable logistic regression was used to test whether cCBF predicted good neurological outcome (modified Rankin Scale score, 0-2) at 90 days. Results- Seventy-seven patients (41 women) met the inclusion criteria with median (interquartile range) age of 66 (55-76) yrs, onset-to-imaging time of 4.8 (3.6-7.7) hours, and baseline National Institutes of Health Stroke Scale score of 13 (9-20). Median cCBF was 38.9 (31.2-44.5) mL per 100 g/min. Higher cCBF predicted good outcome at day 90 (odds ratio, 4.6 [95% CI, 1.4-14.7]; P=0.01), after controlling for baseline National Institutes of Health Stroke Scale, diffusion-weighted imaging lesion volume, and intra-arterial therapy. Conclusions- Higher quantitative cCBF at baseline is a significant predictor of good neurological outcome at day 90. cCBF levels may inform decisions regarding stroke triage, treatment of acute stroke, and general outcome prognosis. Clinical Trial Registration- URL: https://www.clinicaltrials.gov. Unique identifier: NCT02225730.


Assuntos
Encéfalo/irrigação sanguínea , Circulação Cerebrovascular/fisiologia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/fisiopatologia , Idoso , Isquemia Encefálica/complicações , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neuroimagem/métodos , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA