Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Electrocardiol ; 69: 30-35, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34547542

RESUMO

BACKGROUND: QRS duration and morphology including left bundle branch block (LBBB) are the most widely used electrocardiogram (ECG) markers for assessing ventricular dyssynchrony and predicting heart failure (HF). However, the vectorcardiographic QRS area may more accurately identify delayed left ventricular activation and HF development. OBJECTIVE: We investigated the association between QRS area and incident HF risk in patients with LBBB. METHODS: By crosslinking data from Danish nationwide registries, we identified patients with a first-time digital LBBB ECG between 2001 and 2015. The vectorcardiographic QRS area was derived from a 12­lead ECG using the Kors transformation method and grouped into quartiles. The endpoint was a composite of HF diagnosis, filled prescriptions for loop diuretics, or death from HF. Cause-specific multivariable Cox regression was used to compute hazard ratios(HR) with 95% confidence intervals(CI). RESULTS: We included 3316 patients with LBBB free from prior HF-related events (median age, 72 years; male, 40%). QRS area quartiles comprised Q1, 36-98 µVs; Q2, 99-119 µVs; Q3, 120-145 µVs; and Q4, 146-295 µVs. During a 5-year follow-up, 31% of patients reached the composite endpoint, with a rate of 39% in the highest quartile Q4. A QRS area in quartile Q4 was associated with increased hazard of the composite endpoint (HR:1.48, 95%CI:1.22-1.80) compared with Q1. CONCLUSIONS: Among primary care patients with newly discovered LBBB, a large vectorcardiographic QRS area (146-295 µVs) was associated with an increased risk of incident HF diagnosis, filling prescriptions for loop diuretics, or dying from HF within 5-years.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estudos de Coortes , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 43(5): 503-510, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32285950

RESUMO

BACKGROUND: A low electrocardiogram (ECG) lead one ratio (LOR) of the maximum positive/negative QRS amplitudes is associated with lower left ventricular ejection fraction (LVEF) and worse outcomes in left bundle branch block (LBBB); however, the impact of LOR on cardiac resynchronization therapy (CRT) outcomes is unknown. We compared clinical outcomes and echocardiographic changes after CRT implantation by LOR. METHODS: Consecutive CRT-defibrillator recipients with LBBB implanted between 2006 and 2015 at Duke University Medical Center were included (N = 496). Time to heart transplant, left ventricular assist device (LVAD) implantation, or death was compared among patients with LOR <12 vs ≥12 using Cox-proportional hazard models. Changes in LVEF and LV volumes after CRT were compared by LOR. RESULTS: Baseline ECG LOR <12 was associated with an adjusted hazard ratio (HR) of 1.69 (95% CI: 1.12-2.40, P = .01) for heart transplant, LVAD, or death. Patients with LOR <12 had less reduction of LV end diastolic volume (ΔLVEDV -4 ± 21 vs -13 ± 23%, P = .04) and LV end systolic volume (ΔLVESV -9 ± 27 vs -22 ± 26%, P = .03) after CRT. In patients with QRS duration (QRSd) ≥150 ms, LOR <12 was associated with an adjusted HR of 2.01 (95% CI 1.21-3.35, P = .008) for heart transplant, LVAD, or death, compared with LOR ≥12. CONCLUSIONS: Baseline ECG LOR <12 portends worse outcomes after CRT implantation in patients with LBBB, specifically among those with QRSd ≥150 ms. This ECG ratio may identify patients with a class I indication for CRT implantation at high risk for poor postimplantation outcomes.


Assuntos
Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Idoso , Bloqueio de Ramo/mortalidade , Ecocardiografia , Eletrocardiografia , Feminino , Transplante de Coração , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico
3.
Pacing Clin Electrophysiol ; 43(11): 1333-1343, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32901967

RESUMO

BACKGROUND: Biventricular (BiV) pacing increases transmural repolarization heterogeneity due to epicardial to endocardial conduction from the left ventricular (LV) lead. However, limited evidence is available on concomitant changes in ventricular depolarization and repolarization and long-term outcomes of BiV pacing. Therefore, we investigated associations of BiV pacing-induced concomitant changes in ventricular depolarization and repolarization with mortality (i.e., LV assist device, heart transplantation, or all-cause mortality) and sustained ventricular arrhythmia endpoints. METHODS: Consecutive BiV-defibrillator recipients with digital preimplantation and postimplantation electrocardiograms recorded between 2006 and 2015 at Duke University Medical Center were included. We calculated changes in QRS duration and corrected JT (JTc) interval and split them by median values. For simplicity, these variables were named QRSdecreased (≤ -12 ms), QRSincreased (> -12 ms), JTcdecreased (≤22 ms), and JTcincreased (> 22 ms) and subsequently used to construct four mutually exclusive groups. RESULTS: We included 528 patients (median age, 68 years; male, 69%). No correlation between changes in QRS duration and JTc interval was observed (P = .295). Compared to QRSdecreased /JTcincreased , increased risk of the composite mortality endpoint was associated with QRSdecreased /JTcdecreased (hazard ratio [HR] = 1.62; 95% confidence interval [CI] = 1.09-2.43), QRSincreased /JTcdecreased (HR = 1.86; 95% CI = 1.27-2.71), and QRSincreased /JTcincreased (HR = 2.25; 95% CI = 1.52-3.35). No QRS/JTc group was associated with excess sustained ventricular arrhythmia risk (P = .400). CONCLUSION: Among BiV-defibrillator recipients, QRSdecreased /JTcincreased was associated with the most favorable long-term survival free of LV assist device, heart transplantation, and sustained ventricular arrhythmias. Our findings suggest that improved electrical resynchronization may be achieved by assessing concomitant changes in ventricular depolarization and repolarization.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/terapia , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Idoso , Bloqueio de Ramo/fisiopatologia , Cardiomiopatias/fisiopatologia , Causas de Morte , Desfibriladores Implantáveis , Eletrocardiografia , Feminino , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos
4.
J Cardiovasc Electrophysiol ; 30(11): 2475-2483, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31535746

RESUMO

BACKGROUND: Changes in left ventricular (LV) activation after cardiac resynchronization therapy (CRT) influence survival but are difficult to quantify noninvasively. METHODS AND RESULTS: We studied 527 CRT patients to assess whether noninvasive quantification of changes in LV activation, defined by change (Δ) in QRS area (QRSA), can predict outcomes after CRT. The study outcome was time until LV assist device(LVAD), cardiac transplant, or death. The three-dimensional QRSA was measured from clinical 12 lead ECGs which were transformed into vectorcardiograms using the Kors method. QRSA was calculated as (QRSx2 + QRSy2 + QRSz2 )1/2 ; ΔQRSA was calculated as post-QRSA minus pre-QRSA, where a negative value represents a reduction in LV activation delay. Kaplan-Meier plots and multivariable Cox proportional hazards models were used to relate ΔQRSA area with outcomes after stratifying the population into quartiles of ΔQRSA. The median baseline QRSA of 93.6 µVs decreased to 59.7 µVs after CRT. Progressive reductions in QRSA with CRT were associated with a lower rate of LVAD, transplant, or death across patient quartiles (P < .001). In Cox regression analyses, ΔQRSA was associated with outcomes independent of QRS morphology and other clinical variables (Q1[greatest decrease] vs Q4[smallest change=reference], HR 0.45, CI, 0.30-0.70, P < .001). There was no interaction between ΔQRSA and QRS morphology. CONCLUSIONS: CRT induced ΔQRSA was associated with clinically meaningful changes in event-free survival. ΔQRSA may be a novel target to guide lead implantation and device optimization.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Potenciais de Ação , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
5.
Pacing Clin Electrophysiol ; 42(11): 1477-1485, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31509260

RESUMO

BACKGROUND: PR interval prolongation is associated with poor outcome after cardiac resynchronization therapy (CRT) among patients with left bundle branch block (LBBB) but the mechanisms are unknown. We investigated clinical outcomes, electrocardiogram (ECG), and echocardiogram changes after CRT by PR interval. METHODS: This is a retrospective study of CRT recipients with a baseline ejection fraction ≤35% and ECG showing sinus rhythm and LBBB. Patients were stratified by baseline PR interval quartile and the primary combined endpoint was time to heart transplantation, left ventricular assist device (LVAD) implantation, or death. ECG, echocardiogram, and clinical variables were compared to identify mechanisms for observed differences in outcomes. RESULTS: Of 291 eligible patients, the mean age was 65 years, 60% were male, and 19% had prior atrial fibrillation. Patients with PR prolongation (quartile 4, PR > 200 ms) more frequently had a history of atrial fibrillation, coronary artery bypass graft surgery, prior implantable cardioverter defibrillator implantation, and use of amiodarone than patients in PR quartiles 1-3. A PR > 200ms was associated with an adjusted hazard ratio of 1.7 (95% CI: 1.1-2.5) for the primary endpoint. Patients with PR > 200 ms had less reduction in QRS duration and QRS area after CRT while having more increase in QT and QTc intervals than patients with PR ≤ 200 ms. No major differences were observed in echocardiography by baseline PR interval quartiles. CONCLUSIONS: PR prolongation predicts shorter survival free of heart transplantation or LVAD implantation in patients with LBBB. This may be due to inadequate ventricular resynchronization.


Assuntos
Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Eletrocardiografia , Idoso , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
6.
Cardiovasc Ultrasound ; 17(1): 10, 2019 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-31113440

RESUMO

BACKGROUND: The association of a Classical left bundle branch block (LBBB) contraction pattern and better outcome after cardiac resynchronization therapy (CRT) has only been studied using vendor-specific software for echocardiographic speckle-tracked longitudinal strain analysis. The purpose of this study was to assess whether a Classical LBBB contraction pattern on longitudinal strain analysis using vendor-independent software is associated with clinical outcome in CRT recipients with LBBB. METHODS: This was a retrospective cohort study including CRT recipients with LBBB, heart failure, and left ventricular (LV) ejection fraction ≤35%. Speckle-tracked echocardiographic longitudinal strain analysis was performed retrospectively on echocardiograms using vendor-independent software. The presence of a Classical LBBB contraction pattern was determined by consensus of two readers. The primary end point was a composite of time to death, heart transplantation or LV assist device implantation. Secondary outcome was ≥15% reduction in LV end-systolic volume. Intra- and inter-reader agreement of the longitudinal strain contraction pattern was assessed by calculating Cohen's κ. RESULTS: Of 283 included patients, 113 (40%) were women, mean age was 66 ± 11 years, and 136 (48%) had ischemic heart disease. A Classical LBBB contraction pattern was present in 196 (69%). The unadjusted hazard ratio for reaching the primary end point was 1.93 (95% confidence interval, 1.36-2.76, p < 0.001) when comparing patients without to patients with a Classical LBBB contraction pattern. Adjusted for ischemic heart disease and QRS duration < 150 milliseconds the hazard ratio was 1.65 (95% confidence interval, 1.12-2.43, p = 0.01). Of the 123 (43%) patients with a follow-up echocardiogram, 64 of 85 (75%) of patients with a Classical LBBB contraction pattern compared to 13 of 38 (34%) without, had ≥15% reduction in LV end-systolic volume (p < 0.001). Cohen's κ were 0.86 (95% confidence interval, 0.71-1.00) and 0.42 (95% confidence interval, 0.30-0.54) for intra- and inter-reader agreement, respectively. CONCLUSION: Using vendor-independent strain software, a Classical LBBB contraction pattern is associated with better outcome in CRT recipients with LBBB, but inter-reader agreement for the classification of contraction pattern is only moderate.


Assuntos
Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Comércio , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Estudos Retrospectivos , Software , Volume Sistólico/fisiologia
8.
Circ Heart Fail ; 14(10): e008364, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34587762

RESUMO

BACKGROUND: Patients with severe mental illness (SMI) including schizophrenia, bipolar disorder, and severe depression have earlier onset of cardiovascular risk factors, predisposing to worse future heart failure (HF) compared with the general population. We investigated associations between the presence/absence of SMI and long-term HF outcomes. METHODS: We identified patients with HF with and without SMI in the Duke University Health System from 2002 to 2017. Using multivariable Cox regression, we examined the primary outcome of all-cause mortality. Secondary outcomes included rates of implantable cardioverter defibrillator use, cardiac resynchronization therapy, left ventricular assist device implantation, and heart transplantation. RESULTS: We included 20 906 patients with HF (SMI, n=898; non-SMI, n=20 008). Patients with SMI presented clinically 7 years earlier than those without SMI. We observed an interaction between SMI and sex on all-cause mortality (P=0.002). Excess mortality was observed among men with SMI compared with men without SMI (hazard ratio, 1.36 [95% CI, 1.17-1.59]). No association was observed among women with and without SMI (hazard ratio, 0.97 [95% CI, 0.84-1.12]). Rates of implantable cardioverter defibrillator use, cardiac resynchronization therapy, left ventricular assist device implantation, and heart transplantation were similar between patients with and without SMI (6.1% versus 7.9%, P=0.095). Patients with SMI receiving these procedures for HF experienced poorer prognosis than those without SMI (hazard ratio, 2.12 [95% CI, 1.08-4.15]). CONCLUSIONS: SMI was associated with adverse HF outcome among men and not women. Despite equal access to procedures for HF between patients with and without SMI, those with SMI experienced excess postprocedural mortality. Our data highlight concurrent sex- and mental health-related disparities in HF prognosis, suggesting that patients with SMI, especially men, merit closer follow-up.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Coração/fisiopatologia , Idoso , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
Heart Rhythm O2 ; 1(4): 243-249, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34113878

RESUMO

BACKGROUND: Women seem to derive more benefit from cardiac resynchronization therapy (CRT) than men, even after accounting for the higher burden of risk factors for nonresponse often observed in men. OBJECTIVE: To assess for sex-specific differences in left ventricular (LV) electrical dyssynchrony as a contributing electrophysiological explanation for the greater degree of CRT benefit among women. METHODS: We compared the extent of baseline LV electrical dyssynchrony, as measured by the QRS area (QRSA), among men and women with left bundle branch block (LBBB) undergoing CRT at Duke University (n = 492, 35% women) overall and in relation to baseline QRS characteristics using independent sample t tests and Pearson correlation coefficients. Cox regression analyses were used to relate sex, QRSA, and QRS characteristics to the risk of cardiac transplantation, LV assist device implant, or death. RESULTS: Although the mean QRS duration (QRSd) did not differ by sex, QRSA was greater for women vs men (113.8 µVs vs 98.2 µVs, P < .001), owing to differences in the QRSd <150 ms subgroup (92.3 ± 28.7 µVs vs 67.6 ± 26.2 µVs, P < .001). Among those with nonstrict LBBB, mean QRSd was similar but QRSA was significantly greater among women than men (96.0 ± 25.0 µVs vs 63.6 ± 26.2 µVs, P < .001). QRSA was similar among men and women with strict LBBB (P = .533). Female sex was associated with better long-term outcomes in an unadjusted model (hazard ratio 0.623, confidence interval 0.454-0.857, P = .004) but sex no longer predicted outcomes after accounting for differences in QRSA. CONCLUSIONS: Our study suggests that sex-specific differences in LV dyssynchrony contribute to greater CRT benefit among women. Standard QRSd and morphology assessments seem to underestimate the extent of LV electrical dyssynchrony among women with LBBB.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA