Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Epidemiol ; 34(3): 137-143, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-37211396

RESUMO

BACKGROUND: Glomerular hyperfiltration has been reported to be associated with adverse renal outcomes in the general population. It is not known whether drinking pattern is associated with the risk of glomerular hyperfiltration in healthy individuals. METHODS: We prospectively followed middle-aged 8,640 Japanese men with normal renal function, no proteinuria, no diabetes, and no use of antihypertensive medications at entry. Data on alcohol consumption were gathered by questionnaire. Glomerular hyperfiltration was defined as estimated glomerular filtration rate (eGFR) ≥117 mL/min/1.73 m2, which was the upper 2.5th percentile value of eGFR in the entire cohort. RESULTS: During 46,186 person-years of follow-up, 330 men developed glomerular hyperfiltration. In a multivariate model, for men who consumed alcohol on 1-3 days per week, alcohol consumption of ≥69.1 g ethanol/drinking day was significantly associated with the risk of glomerular hyperfiltration (hazard ratio [HR] 2.37; 95% confidence interval [CI], 1.18-4.74) compared with non-drinkers. For those who consumed alcohol on 4-7 days per week, higher alcohol consumption per drinking day was associated with a higher risk of glomerular hyperfiltration: the HRs for alcohol consumption of 46.1-69.0, and ≥69.1 g ethanol/drinking day were 1.55 (95% CI, 1.01-2.38), and 1.78 (95% CI, 1.02-3.12), respectively. CONCLUSION: For high drinking frequency per week, more alcohol intake per drinking day was associated with an increased risk of glomerular hyperfiltration, while for low drinking frequency per week, only very high alcohol intake per drinking day was associated with an increased risk of glomerular hyperfiltration in middle-aged Japanese men.


Assuntos
Consumo de Bebidas Alcoólicas , Nefropatias , Pessoa de Meia-Idade , Masculino , Humanos , Japão/epidemiologia , Estudos Prospectivos , Consumo de Bebidas Alcoólicas/efeitos adversos , Consumo de Bebidas Alcoólicas/epidemiologia , Nefropatias/epidemiologia , Taxa de Filtração Glomerular , Etanol , Fatores de Risco
2.
Shokuhin Eiseigaku Zasshi ; 64(2): 78-88, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-37211389

RESUMO

The official specifications for food additives from natural sources list the species according to their scientific and Japanese names, thereby providing a unique identifier for the species. This helps to prevent the use of nonprescribed species, which might cause unexpected or unintended health hazards. However, there are cases in which the names of the source species listed in the official specifications differ from the accepted scientific names based on the latest taxonomic research. In this paper, we argue that it is more important to define scientific and Japanese names with an emphasis on traceability in order to control the range of food additive ingredients in a rational and sustainable manner. Therefore, we proposed a method for ensuring traceability as well as a specific notation procedure for scientific and Japanese names. Using this method, we examined the source species for three food additives. In some cases, the range of sources species expanded with the change in scientific names. Ensuring traceability is extremely important, but it is also necessary to confirm whether unexpected species are included when names are changed.


Assuntos
Aditivos Alimentares , Aditivos Alimentares/normas , Japão
3.
Shokuhin Eiseigaku Zasshi ; 64(1): 47-52, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-36858591

RESUMO

A simple and reliable analytical method has been developed for the determination of pantothenic acid in food. For the high-protein food, 20 mL of water was added to 2 g of sample, and after homogenization extraction, 1 mL of 15% zinc sulfate solution was added, mixed well, centrifuged, and the supernatant was filtered to make the test solution. For the low-protein food, 20 mL of 1% formic acid solution was added to 2 g of sample, homogenized, extracted, centrifuged, and the supernatant was filtered to make the test solution. The HPLC separation was carried out on a L-column2 ODS column with 0.02 mol/L phosphate solution (pH 3.0)- acetonitrile (95 : 5) as the mobile phase, and detected at 200 nm. The LC-MS/MS conditions were L-column2 ODS as the separation column, 5 mmol/L ammonium formate (containing 0.01% formic acid)-methanol (85 : 15) as the mobile phase, and multiple reaction monitoring (MRM) was used for detection. The recoveries of pantothenic acid in milk powder and nutritional food products were more than 88% with high precision. As a result of analyzing commetrcially available foods labeled as containing pantothenic acid, analytical values almost identical to the labeled values were obtained, and a high correlation was observed between the values obtained by HPLC and LC-MS/MS.


Assuntos
Ácido Pantotênico , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida
4.
Shokuhin Eiseigaku Zasshi ; 64(4): 145-153, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-37673604

RESUMO

We determined the fifteen types of plasticizers, including four kinds of phthalic acid esters (PAEs) used in 220 polyvinyl chloride (PVC) toys on Japanese market from 2019 to 2020. Three kinds of previously undetected types of PAEs were also detected, but not identified in this study. Di (2-ethylhexyl) terephthalate (DEHTP) was the highest detection rate in 209 soft PVC toys out of 220 toys, with 71.2% for designated toys and 88.9% for not-designated toys, respectively, showing a gradual increase from the previous reports in 2009 and 2014. On the other hand, the usages of o-acetyl tributyl citrate and adipic acid esters decreased, but the six types of PAEs prohibited to use for the designated toys in Japan were not detected in them, the usage of diisobutyl phthalate were increased. In contrast, four types of PAEs were detected in not-designated toys. Among them, the detection ratio of di (2-ethyhexyl) phthalate decreased to about 1/10. The content levels of plasticizers in per each sample were continued to keep low level from the report five years ago. These results showed that the main plasticizer used in PVC toys is DEHTP, and that the usage of other plasticizers was decreased.


Assuntos
Plastificantes , Cloreto de Polivinila , Ésteres , Japão
5.
Shokuhin Eiseigaku Zasshi ; 64(3): 111-115, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-37380481

RESUMO

A validation study was performed on the modified analytical method for the migration solution of heptane, 20% ethanol and 4% acetic acid for the determination of bisphenol A migrating from polycarbonate food apparatuses, containers, and packaging. The analytes for the method were bisphenol A, phenol and p-tert-butylphenol. The repeatability, within-laboratory reproducibility and trueness of the method was estimated in the range of 0.2-1.8%, 0.4-2.6% and 95-102% respectively. These results showed that the method is useful as an analytical method for the migration solution of heptane, 20% ethanol and 4% acetic acid. Furthermore, the applicability of the determination methods with a fluorescence detector was verified. As a result of the validation study, the repeatability, within-laboratory reproducibility and trueness of the method was estimated in the range of 0.1-2.9%, 0.2-3.1% and 94-101% respectively. It was confirmed that the measurement with a fluorescence detector is also available.


Assuntos
Ácido Acético , Fenóis , Reprodutibilidade dos Testes , Etanol , Heptanos
6.
Shokuhin Eiseigaku Zasshi ; 64(2): 69-77, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-37211388

RESUMO

The growth and gas production test for Escherichia coli in the microbiological examination of food additives is stipulated in the ninth edition of Japan's Specifications and Standards for Food Additives (JSFA) and described as a part of the "Confirmation Test for Escherichia coli" in "Microbial Limit Tests" in the same manuscript. The growth and gas production test for E. coli indicated that the positive or negative of "gas production and/or turbidity" in EC broth should be confirmed after incubating at 45.5±0.2℃ for 24±2 h. If both gas production and turbidity are negative, the culture is additionally incubated up to 48±2 h to determine E. coli contamination. The internationally referenced Bacteriological Analytical Manual of the U.S. FDA had revised the incubation temperature in tests for coliforms and E. coli from 45.5±0.2℃ to 44.5±0.2℃ in 2017. Therefore, we conducted research in anticipation of this temperature change being reflected in the microbiological examination of the JSFA. We used seven EC broth products and six food additives across eight products that are available in Japan in order to compare the growth and gas production at temperatures of 45.5±0.2℃ and 44.5±0.2℃ of E. coli NBRC 3972, which is designated as the test strain in JSFA. Both with/without food additives, the number of EC broth products in which medium turbidity and gas production by the strain were positive in three out of three tubes at all test times was greater at 44.5±0.2℃ than at 45.5±0.2℃. These results suggest that the growth and gas production test for E. coli could be more appropriately conducted by incubation at 44.5±0.2℃ in the "Confirmation Test for Escherichia coli" for E. coli in the JSFA in comparison to 45.5±0.2℃. Furthermore, there were differences in the growth and gas production of E. coli NBRC 3972 depending on the EC broth product used. Therefore, the importance of "Media growth promotion test" and "Method suitability test" in the ninth edition of the JSFA should be emphasized.


Assuntos
Escherichia coli , Microbiologia de Alimentos , Meios de Cultura , Japão
7.
Shokuhin Eiseigaku Zasshi ; 64(6): 240-245, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-38171896

RESUMO

In general, nitrite in food is extracted under slightly alkaline conditions, deproteinized, and analyzed by a colorimetric method using color development by diazotization. However, depending on the sample, the sample solution may become cloudy and difficult to filter by the deproteinization treatment of the analytical method. Recently, an improved analytical method that solves these problems has been reported. Therefore, a validation study was performed on the improved analytical method was performed. The concentrations of sodium nitrite added to cod roe, fish sausage, and ham, which were not labeled with sodium nitrite, were set at the upper limits of the standards for use. We set the target values of 70-120% for trueness, less than 15% for intralaboratory reproducibility, and less than intralaboratory reproducibility for repeatability. As a result, the target values were met for the three samples verified: 88-92% for trueness, 2.0-3.0% for repeatability, and 3.2-4.3% for intralaboratory reproducibility. In addition, an interlaboratory study was conducted by eight institutes on the improved analytical method for nitrite. At each institution, sodium nitrite was added to the same three samples as in the validation study, at concentrations equivalent to twice the lower limit of quantification and the upper limit of the standards for use and analyzed in triplicate. The estimated trueness from the obtained analyses ranged from 82 to 95%, the repeatability ranged from 2.3 to 5.8%, and the inter-room reproducibility ranged from 3.5 to 11%. Thus, the improved analytical method could be useful for determining nitrite in foods.


Assuntos
Produtos da Carne , Nitrito de Sódio , Animais , Reprodutibilidade dos Testes , Produtos da Carne/análise , Colorimetria/métodos
8.
Shokuhin Eiseigaku Zasshi ; 64(4): 154-160, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-37673605

RESUMO

An inter-laboratory study involving 24 laboratories was conducted to validate the modified analytical method for the migration solution of heptane for the determination of bisphenol A migrating from polycarbonate food processing materials. In this study, two concentrations of samples were blindly coded. Each laboratory determined the analyte (bisphenol A, phenol and p-tert-butylphenol) concentration in each sample according to the established protocol. The obtained values were analyzed statistically using internationally accepted guidelines. Horwitz ratios were calculated based on the reproducibility relative standard deviation (RSDR), which was estimated from the inter-laboratory study, and predicted RSDR, which was calculated using the Horwitz/Thompson equation. Horwitz ratios of the two samples ranged from 0.15 to 0.37 for the three compounds, meeting the performance criteria of less than 2 set by the Codex Alimentarius for analytical method approval. These results showed that this modified analytical method shows good performance as an analytical method for the migration solution of heptane.


Assuntos
Heptanos , Fenóis , Reprodutibilidade dos Testes
9.
Am J Nephrol ; 53(2-3): 191-198, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35139520

RESUMO

INTRODUCTION: Proteinuria is a risk factor for end-stage renal failure. However, it is not known whether body mass index (BMI) is prospectively associated with the risk of future developing proteinuria, taking into account transient proteinuria. METHODS: We enrolled 9,320 nondiabetic Japanese middle-aged men who had no proteinuria, an estimated glomerular filtration rate ≥60 mL/min/1.73 m2, no history of cancer, and no use of antihypertensive medications at baseline. "Any proteinuria" was defined as proteinuria detected for the first time during the follow-up period regardless of its frequency. "Persistent proteinuria" was defined as proteinuria that was detected at least twice consecutively at annual examinations and did not return to negative until the end of the follow-up. RESULTS: During the 11-year follow-up period, 1,972 cases of any proteinuria and 151 cases of persistent proteinuria were confirmed. Both lower and higher BMI were associated with the risk of any proteinuria. As for persistent proteinuria, in those with a BMI ≥20 kg/m2, higher BMI was associated with a higher risk of future persistent proteinuria. The association between BMI and the risk of persistent proteinuria was stronger than that between BMI and any proteinuria. In multiple-adjusted model, hazard ratios of persistent proteinuria for BMI <18.0, 18.0-19.9, 20.0-21.9, 22.0-23.9, 24.0-25.9, 26.0-27.9, and ≥28.0 kg/m2 were 1.52 (95% confidence interval 0.51-4.49), 1.07 (0.49-2.29), 1.00 (reference), 1.14 (0.64-2.01), 1.89 (1.09-3.27), 2.12 (1.15-3.93), and 3.85 (2.03-7.30), respectively. DISCUSSION/CONCLUSION: In those with a BMI ≥20 kg/m2, higher BMI was associated with a higher risk of future persistent proteinuria and any proteinuria. This relationship was stronger for persistent proteinuria than for any proteinuria.


Assuntos
Atenção à Saúde , Proteinúria , Índice de Massa Corporal , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Proteinúria/etiologia , Fatores de Risco
10.
Chem Pharm Bull (Tokyo) ; 70(1): 25-31, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34980729

RESUMO

We report on the recommendation of the simple and versatility of methylated reference (MR) to improve applications in the single reference (SR)-LC based on relative molar sensitivity (RMS). Three curcuminoids (Curs) such as curcumin, demethoxycurcumin and bisdemethoxycurcumin in turmeric products were determined using authentic standards and methylated curcumin. In addition, high-speed countercurrent chromatography (HSCCC) purification is necessary to separate Curs for indicating the RMS. For HSCCC separation, a biphasic solvent system was used to obtain these fractions, which were then subjected to 1H quantitative NMR to determine their contents in each test solution. Using these solutions, the RMS of Curs are calculated from slopes ratios of calibration curves (three ranges from 0-100 µmol/L, r2 > 0.998). The averaged RMS of Curs were 8.92 (relative standard deviation (RSD), 1.17%), 8.97 (2.18%), and 9.61 (0.77%), respectively. Cur concentrations in turmeric products can be determined using RMS, peak area, and MR content added in these samples. This proposed method, which is based on chemical methylation and the SR-LC assay has been successfully applied for the simple and reliable estimation of Curs in turmeric products.


Assuntos
Diarileptanoides/química , Cromatografia Líquida de Alta Pressão/normas , Metilação , Estrutura Molecular , Padrões de Referência
11.
Shokuhin Eiseigaku Zasshi ; 63(2): 97-103, 2022.
Artigo em Japonês | MEDLINE | ID: mdl-35650035

RESUMO

We modified a method for determining methanol content in detergents used in kitchens. Furthermore, an inter-laboratory study was conducted in 10 laboratories to validate the modified method. In this study, two concentrations of samples were blindly coded. Each laboratory determined the methanol content in each sample according to a protocol. The determined values were statistically analyzed according to an international harmonized guideline. HorRat values were calculated based on the reproducibility relative standard deviation (RSDR) which was estimated from the interlaboratory study, and predicted RSDR calculated from the Horwitz/Thompson equation. The HorRat values of the two samples were 0.8 and 1.8, meeting the performance criteria of less than 2 set by the Codex Alimentarius for analytical method approval. These results confirm that this modified analytical method shows good performance as an analytical method for determining methanol content in kitchen detergents.


Assuntos
Detergentes , Metanol , Laboratórios , Reprodutibilidade dos Testes
12.
Shokuhin Eiseigaku Zasshi ; 63(2): 51-61, 2022.
Artigo em Japonês | MEDLINE | ID: mdl-35650029

RESUMO

Migration test of food utensils, containers, and packaging is an important test method for confirming the safety and their compliance to the standards. However, there is little report on inter-laboratory study which was performed to evaluate the entire migration test, including migration operations and quantification. An interlaboratory study was performed participating 22 laboratories using 8 types of model synthetic resin samples containing 10 substances with a wide range of Log Pow values to evaluate the accuracy of the entire migration test. As a result, most of HorRat (r) values met the target criteria (0.3

Assuntos
Contaminação de Alimentos , Plásticos , Contaminação de Alimentos/análise , Embalagem de Alimentos , Laboratórios
13.
Chem Pharm Bull (Tokyo) ; 69(1): 18-25, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33390516

RESUMO

Mogroside V is one of the characteristic and effective components of luohanguo extract, a food additive used as a sweetener in Japan as per Japan's Standards and Specifications for Food Additives (JSFA; 9th ed.). JSFA stipulates that the quantitative determination for mogroside V content in luohanguo extract applies HPLC using analytical standard mogroside V. However, no mogroside V reagents with proven purities are commercially available. Therefore the current JSFA determination method is not particularly suited for daily quality control operations involving luohanguo extract. In this study, we applied an alternative quantitative method using a single reference with relative molar sensitivity (RMS). It was possible to calculate the accurate RMS by an offline combination of 1H-quantitative NMR spectroscopy (1H-qNMR) and an HPLC/variable-wavelength detector (VWD). Using the RMS of mogroside V to a commercial certified reference material grade caffeine, the mogroside V contents in luohanguo extracts could be determined using HPLC/VWD without analytical standard mogroside V. There was no significant difference between the mogroside V contents in luohanguo extracts determined using the method employing single-reference caffeine with the RMS and using the JSFA method. The absolute calibration curve for the latter was prepared using an analytical standard mogroside V whose purity was determined by 1H-qNMR. These results demonstrate that our proposed method using a single reference with RMS is suitable for quantitative determination of mogroside V in luohanguo extract and can be used as an alternative method to the current assay method in JSFA.


Assuntos
Cafeína/análise , Cucurbitaceae/química , Aditivos Alimentares/análise , Extratos Vegetais/análise , Triterpenos/análise , Cafeína/normas , Cromatografia Líquida de Alta Pressão/normas , Aditivos Alimentares/normas , Japão , Espectroscopia de Ressonância Magnética/normas , Extratos Vegetais/normas , Controle de Qualidade , Triterpenos/normas
14.
J Sci Food Agric ; 101(9): 3804-3810, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33315241

RESUMO

BACKGROUND: Many studies report the monitoring of catechins in tea samples by chromatographic techniques. Unfortunately, only a small number of screening assays for catechins exist as a result of the complexity of authentic standards for the respective calibration curves. In the present study, a single reference (SR) exhaustive assay for the simultaneous quantification of tea-derived catechins by liquid chromatography (LC) with photodiode array and fluorescence detectors based on relative molar sensitivity (RMS) was developed as a screening assay of common tea samples without respective calibration curves using authentic standards. RESULTS: Three original SR standards were proposed based on flavonoid structures, evaluated by quantitative 1 H-NMR based on an indirect standard (1,4-bis(trimethylsilyl) benzene-d4 ) and successfully separated in a LC chromatogram. In tea samples with these added SR calculated based on RMS, the concentrations of eight tea-derived catechins could be measured with a relative SD of < 8.5% by a single LC run. CONCLUSION: This LC screening assay based on RMS allows reliable quantification without the requirement for respective calibration curves using authentic standards. © 2020 Society of Chemical Industry.


Assuntos
Camellia sinensis/química , Catequina/análise , Cromatografia Líquida de Alta Pressão/normas , Chá/química , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Extratos Vegetais/análise , Padrões de Referência
15.
Shokuhin Eiseigaku Zasshi ; 62(3): 73-78, 2021.
Artigo em Japonês | MEDLINE | ID: mdl-34219099

RESUMO

The main component of the Mustard and Horseradish extracts, which are used as natural food additives in Japan, is allyl isothiocyanate (AITC). The determination of AITC using GC-FID is the official method employed in the quality control assessments for these products. In this method, a commercially available AITC reagent is used as a calibrant. However, 1H-quantitative NMR (qNMR) analysis revealed that the AITC reagents contain impurity. Therefore, we examined the GC-FID and HPLC-refractive index detector (LC-RID) method based on relative molar sensitivities (RMSs) to high-purity single reference (SR). The RMSs of AITC/SR under the GC-FID and LC-RID conditions were accurately determined using qNMR. The AITC in two types of food additives was quantified using qNMR, SR GC-FID, and SR LC-RID methods. Both SR GC-FID and SR LC-RID showed good agreement within 2% with the AITC content determined by direct qNMR.


Assuntos
Armoracia , Mostardeira , Cromatografia Líquida de Alta Pressão , Isotiocianatos , Japão , Dente Molar/química , Extratos Vegetais/análise
16.
Rapid Commun Mass Spectrom ; 34 Suppl 2: e8707, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31883162

RESUMO

RATIONALE: Polyamide (PA) is the generic name of polymers synthesized by linking monomers via amide bonds, and various types of PAs with different monomer compositions are known. Distinguishing PA polymers is useful in directing monomer residual testing, product testing, and reverse engineering, but is analytically challenging and cumbersome. To simplify this, we explored the applicability of direct analysis in real time mass spectrometry (DART-MS) for screening PA polymers. METHODS: A DART ion source coupled to a quadrupole Orbitrap (high-resolution (HR) mass spectrometer) was employed for this study. Ten types of PA polymers and four retail samples were evaluated. The DART-HRMS data for these samples, as well as the DART-MS/MS (MS2 ) data for PA6 and PA66, were obtained, and their repeatability was assessed across days/calibrations, operators, and equipments. RESULTS: Ions corresponding to the cyclic or linear monomers and oligomers of each PA polymer were detected in each DART-HR mass spectrum. Although similar DART-HR mass spectra were obtained for PA6, PA66, and PA6/PA66 (polymer blends of PA6 and PA66), their DART tandem mass spectra were completely different. The analysis was repeatable, and nearly identical DART tandem mass spectra were obtained on different days, by different operators, and with different equipment. This technique was successfully applied to commercially available samples. CONCLUSIONS: Ten types of PA polymers were distinguished using DART-HRMS and DART-MS2 , and their identification using these techniques was straightforward as the characteristic ions for each PA polymer were identified and detected. Furthermore, the spectra were obtained rapidly. Therefore, DART-HRMS can be considered an efficient screening technique for the rapid identification and differentiation of PA polymers.

17.
J Epidemiol ; 30(4): 163-169, 2020 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-30930374

RESUMO

BACKGROUND: Serum gamma-glutamyltransferase has been recognized as the risk factor of cardiovascular and metabolic diseases. However, the association between serum gamma-glutamyltransferase and the risk of chronic kidney disease is not well known, and no prospective studies have examined separately the relationship of serum gamma-glutamyltransferase with the risk of proteinuria versus that of low estimated glomerular filtration rate (eGFR). METHODS: We prospectively followed 9,341 Japanese men who did not have low eGFR, proteinuria, or diabetes, and did not take antihypertensive medications at entry for the analysis of proteinuria, and we followed 9,299 men for the analysis of low eGFR. We defined "persistent proteinuria" as proteinuria detected two or more times consecutively and persistently as ≥1+ on urine dipstick at the annual check-up until the end of follow-up. Low eGFR was defined as eGFR <60 mL/min/1.73 m2. RESULTS: During the 11-year observation period, 151 men developed persistent proteinuria and 1,276 men developed low eGFR. In multivariate models, the highest quartile (≥71 IU/L) of serum gamma-glutamyltransferase was independently related to the development of persistent proteinuria (hazard ratio 3.39; 95% confidence interval, 1.92-5.97) compared with the lowest quartile (≤25 IU/L). In joint analysis of alcohol consumption and serum gamma-glutamyltransferase, non-drinkers in the highest tertile (≥58 IU/L) of serum gamma-glutamyltransferase had the highest risk of persistent proteinuria. However, there was no association between serum gamma-glutamyltransferase and low eGFR. CONCLUSION: In middle-aged Japanese men, elevated serum gamma-glutamyltransferase was independently associated with future persistent proteinuria, but not with low eGFR.


Assuntos
Consumo de Bebidas Alcoólicas/sangue , Consumo de Bebidas Alcoólicas/epidemiologia , Proteinúria/epidemiologia , Insuficiência Renal Crônica/epidemiologia , Adulto , Idoso , Consumo de Bebidas Alcoólicas/efeitos adversos , Estudos de Coortes , Feminino , Taxa de Filtração Glomerular/fisiologia , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Proteinúria/sangue , Proteinúria/fisiopatologia , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/etiologia , Fatores de Risco , gama-Glutamiltransferase/sangue
18.
Regul Toxicol Pharmacol ; 114: 104664, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32353473

RESUMO

2,4-Dimethyl-4-phenyltetrahydrofuran (CAS no. 82461-14-1) is a food additive used as a synthetic flavoring substance. To investigate the toxicological properties and determine the no-observed-adverse-effect level (NOAEL), a 90-day repeated oral dose toxicity study of 2,4-dimethyl-4-phenyltetrahydrofuran containing four stereoisomers was conducted in F344 rats at doses of 0, 6, 24, and 96 mg/kg body weight (BW)/day. No mortality or abnormal clinical signs related to treatment in any group was observed. At a dose of 96 mg/kg BW, fluctuated serum total protein and total cholesterol and increased absolute and relative liver weights and relative kidney weights were observed in both sexes. Increased serum albumin in males and decreased Na and Cl in females were also observed. On histopathological assessment, at a dose of 96 mg/kg BW, diffuse hepatocellular hypertrophy in the liver in both sexes and tubular regeneration with scattered proximal tubular degeneration and/or necrosis throughout the cortex in the kidney in males were detected. Based on these findings, the NOAEL for 2,4-dimethyl-4-phenyltetrahydrofuran used in the current study was found to be 24 mg/kg BW/day for both sexes.


Assuntos
Aromatizantes/toxicidade , Rim/efeitos dos fármacos , Fígado/efeitos dos fármacos , Administração Oral , Animais , Relação Dose-Resposta a Droga , Feminino , Aromatizantes/administração & dosagem , Rim/patologia , Fígado/patologia , Masculino , Conformação Molecular , Nível de Efeito Adverso não Observado , Ratos , Ratos Endogâmicos F344 , Estereoisomerismo , Fatores de Tempo
19.
Shokuhin Eiseigaku Zasshi ; 61(2): 72-76, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-32336712

RESUMO

We used ion chromatography with post column derivatization to measure chromium (VI) concentrations in 155 mineral water (MW) products purchased from markets in Japan in 2018. Chromium (VI) recovery in spiked samples of the 155 MW products ranged from 95 to 106%, suggesting that this method is well suited for ensuring that MW products meet the requisite health and food safety standards. Chromium (VI) levels were above detection limits in 54 of the MW products, giving a total detection rate of 35%. The minimum and maximum chromium (VI) concentrations in all of the MW products were 0.0001 mg/L and 0.045 mg/L, respectively. The median chromium (VI) concentration was 0.0003 mg/L, with most MW products having chromium (VI) concentrations in the range of 0.0001 to 0.0002 mg/L. None of the MW products had chromium (VI) concentrations that exceeded the current standard value (0.05 mg/L) for MW in Japan.


Assuntos
Cromo/análise , Água Potável/análise , Águas Minerais/análise , Japão
20.
Shokuhin Eiseigaku Zasshi ; 61(2): 53-57, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-32336709

RESUMO

Considerable amounts of processed foods contain vitamin D (ergocalciferol (D2) and cholecalciferol (D3)) as food additives. For field surveys on food additives, the analytical method for vitamin D should be well-validated. However, the current official method in Japan cannot separately determine the concentrations of D2 and D3, whereas the method for the Standard Tables of Food Composition in Japan 2015 (STFC method) can. Therefore, in this study, we verified the applicability of the STFC method to processed foods. During the course of this research, we added some improvements to the original method. Spike and recovery experiments using vegetable juice, soymilk, and corn flakes as food matrices showed that the recovery rates (relative standard deviation) of D2 and D3 were 103-112% (4.7-12.6%) and 102-109% (2.4-21.8%), respectively, at the estimated method limit of quantification (EMLOQ) level; and 100-110% (4.0-7.4%) and 102-105% (3.8-4.8%), respectively, at 10 times the EMLOQ level. These results indicated that accuracy and precision of the modified STFC method were enough to determine dietary D2 and D3 as endogenous nutrients and/or food additives, and suggested that this method is appropriate for analyzing vitamin D concentrations in processed foods.


Assuntos
Colecalciferol/análise , Ergocalciferóis/análise , Análise de Alimentos/normas , Vitaminas/análise , Japão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA