Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Phys Rev Lett ; 108(22): 223902, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-23003595

RESUMO

In preparation for real space studies of magnetic domains in a pump-probe setup at free-electron laser sources, it is necessary to develop an imaging method compatible with the linearly polarized radiation available at these sources. We present results from a prototype experiment performed at the synchrotron source BESSY II, using a modification of existing phase retrieval techniques. Our results show that it is possible to image magnetic domains in real space using linear polarized light, and we introduce the concept of a reliability map of our reconstructions using Gabor transforms.

2.
Phys Rev Lett ; 108(26): 267403, 2012 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-23005013

RESUMO

We present the first single-shot images of ferromagnetic, nanoscale spin order taken with femtosecond x-ray pulses. X-ray-induced electron and spin dynamics can be outrun with pulses shorter than 80 fs in the investigated fluence regime, and no permanent aftereffects in the samples are observed below a fluence of 25 mJ/cm(2). Employing resonant spatially muliplexed x-ray holography results in a low imaging threshold of 5 mJ/cm(2). Our results open new ways to combine ultrafast laser spectroscopy with sequential snapshot imaging on a single sample, generating a movie of excited state dynamics.

3.
Opt Express ; 18(18): 18922-31, 2010 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-20940786

RESUMO

Mask-based Fourier transform holography is used to record images of biological objects with 2.2 nm X-ray wavelength. The holography mask and the object are decoupled from each other which allows us to move the field of view over a large area over the sample. Due to the separation of the mask and the sample on different X-ray windows, a gap between both windows in the micrometer range typically exists. Using standard Fourier transform holography, focussed images of the sample can directly be reconstructed only for gap distances within the setup's depth of field. Here, we image diatoms as function of the gap distance and demonstrate the possibility to recover focussed images via a wavefield back-propagation technique. The limitations of our approach with respect to large separations are mainly associated with deviations from flat-field illumination of the object.


Assuntos
Holografia/métodos , Imageamento Tridimensional/métodos , Algoritmos , Desenho de Equipamento , Análise de Fourier , Holografia/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Luz , Modelos Estatísticos , Modelos Teóricos , Silício/química , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA