Cureus ; 14(2): e22435, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35345703

RESUMO

Background Neural networks for analyzing MRIs are oftentimes trained on particular combinations of perspectives and acquisition sequences. Since real-world data are less structured and do not follow a standard denomination of acquisition sequences, this impedes the transition from deep learning research to clinical application. The purpose of this study is therefore to assess the feasibility of classifying the acquisition sequence from a single MRI slice using convolutional neural networks. Methods A total of 113 MRI slices from 52 patients were used in a transfer learning approach to train three convolutional neural networks of different complexities to predict the acquisition sequence, while 27 slices were used for internal validation. The model then underwent external validation on 600 slices from 273 patients belonging to one of four classes (T1-weighted without contrast enhancement, T1-weighted with contrast enhancement, T2-weighted, and diffusion-weighted). Categorical accuracy was noted, and the results of the predictions for the validation set are provided with confusion matrices. Results The neural networks achieved a categorical accuracy of 0.79, 0.81, and 0.84 on the external validation data. The implementation of Grad-CAM showed no clear pattern of focus except for T2-weighted slices, where the network focused on areas containing cerebrospinal fluid. Conclusion Automatically classifying the acquisition sequence using neural networks seems feasible and could be used to facilitate the automatic labelling of MRI data.

2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 2723-2726, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946457

RESUMO

Motion imaging phantoms are expensive, bulky and difficult to transport and set-up. The purpose of this paper is to demonstrate a simple approach to the design of multi-modality motion imaging phantoms that use mechanically stored energy to produce motion.We propose two phantom designs that use mainsprings and elastic bands to store energy. A rectangular piece was attached to an axle at the end of the transmission chain of each phantom, and underwent a rotary motion upon release of the mechanical motor. The phantoms were imaged with MRI and US, and the image sequences were embedded in a 1D non linear manifold (Laplacian Eigenmap) and the spectrogram of the embedding was used to derive the angular velocity over time. The derived velocities were consistent and reproducible within a small error. The proposed motion phantom concept showed great potential for the construction of simple and affordable motion phantoms.


Assuntos
Movimento (Física) , Imageamento por Ressonância Magnética , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA