Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Anesthesiology ; 116(2): 311-23, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22222473

RESUMO

BACKGROUND: Various pharmacodynamic response surface models have been developed to quantitatively describe the relationship between two or more drug concentrations with their combined clinical effect. We examined the interaction of remifentanil and sevoflurane on the probability of tolerance to shake and shout, tetanic stimulation, laryngeal mask airway insertion, and laryngoscopy in patients to compare the performance of five different response surface models. METHODS: Forty patients preoperatively received different combined concentrations of remifentanil (0-12 ng/ml) and sevoflurane (0.5-3.5 vol.%) according to a criss-cross design (160 concentration pairs, four per patient). After having reached pseudosteady state, the response to shake and shout, tetanic stimulation, laryngeal mask airway insertion, and laryngoscopy was recorded. For the analysis of the probability of tolerance, five different interaction models were tested: Greco, Reduced Greco, Minto, Scaled C50(O) Hierarchical, and Fixed C50(O) Hierarchical model. All calculations were performed with NONMEM VI (Icon Development Solutions, Ellicott City, MD). RESULTS: The pharmacodynamic interaction between sevoflurane and remifentanil was strongly synergistic for both the hypnotic and the analgesic components of anesthesia. The Greco model did not result in plausible parameter estimates. The Fixed C50(O) Hierarchical model performed slightly better than the Scaled C50(O) Hierarchical and Reduced Greco models, whereas the Minto model fitted less well. CONCLUSION: We showed the importance of exploring various surface model approaches when studying drug interactions. The Fixed C50(O) Hierarchical model fits our data on sevoflurane remifentanil interaction best and appears to be an appropriate model for use in hypnotic-opioid drug interaction.


Assuntos
Anestésicos Inalatórios/metabolismo , Anestésicos Intravenosos/metabolismo , Éteres Metílicos/metabolismo , Modelos Biológicos , Piperidinas/metabolismo , Adulto , Anestésicos Inalatórios/administração & dosagem , Anestésicos Intravenosos/administração & dosagem , Interações Medicamentosas/fisiologia , Sinergismo Farmacológico , Feminino , Humanos , Masculino , Éteres Metílicos/administração & dosagem , Piperidinas/administração & dosagem , Estudos Prospectivos , Remifentanil , Sevoflurano , Adulto Jovem
2.
Anesthesiology ; 112(4): 872-80, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20216387

RESUMO

BACKGROUND: The noxious stimulation response index (NSRI) is a novel anesthetic depth index ranging between 100 and 0, computed from hypnotic and opioid effect-site concentrations using a hierarchical interaction model. The authors validated the NSRI on previously published data. METHODS: The data encompassed 44 women, American Society of Anesthesiology class I, randomly allocated to three groups receiving remifentanil infusions targeting 0, 2, and 4 ng/ml. Propofol was given at stepwise increasing effect-site target concentrations. At each concentration, the observer assessment of alertness and sedation score, the response to eyelash and tetanic stimulation of the forearm, the bispectral index (BIS), and the acoustic evoked potential index (AAI) were recorded. The authors computed the NSRI for each stimulation and calculated the prediction probabilities (PKs) using a bootstrap technique. The PKs of the different predictors were compared with multiple pairwise comparisons with Bonferroni correction. RESULTS: The median (95% CI) PK of the NSRI, BIS, and AAI for loss of response to tetanic stimulation was 0.87 (0.75-0.96), 0.73 (0.58-0.85), and 0.70 (0.54-0.84), respectively. The PK of effect-site propofol concentration, BIS, and AAI for observer assessment of alertness and sedation score and loss of eyelash reflex were between 0.86 (0.80-0.92) and 0.92 (0.83-0.99), whereas the PKs of NSRI were 0.77 (0.68-0.85) and 0.82 (0.68-0.92). The PK of the NSRI for BIS and AAI was 0.66 (0.58-0.73) and 0.63 (0.55-0.70), respectively. CONCLUSION: The NSRI conveys information that better predicts the analgesic component of anesthesia than AAI, BIS, or predicted propofol or remifentanil concentrations. Prospective validation studies in the clinical setting are needed.


Assuntos
Analgésicos Opioides/farmacologia , Anestesia/normas , Hipnóticos e Sedativos/farmacologia , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/normas , Estimulação Física , Estimulação Acústica , Adulto , Algoritmos , Procedimentos Cirúrgicos Ambulatórios , Anestésicos Intravenosos , Interações Medicamentosas , Feminino , Procedimentos Cirúrgicos em Ginecologia , Humanos , Modelos Estatísticos , Dinâmica não Linear , Piperidinas , Propofol , Remifentanil
3.
Med Biol Eng Comput ; 58(2): 239-247, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31741291

RESUMO

This study investigated the accuracy, drift, and clinical usefulness of a new optical transcutaneous oxygen tension (tcPO2) measuring technique, combined with a conventional electrochemical transcutaneous carbon dioxide (tcPCO2) measurement and reflectance pulse oximetry in the novel transcutaneous OxiVenT™ Sensor. In vitro gas studies were performed to measure accuracy and drift of tcPO2 and tcPCO2. Clinical usefulness for tcPO2 and tcPCO2 monitoring was assessed in neonates. In healthy adult volunteers, measured oxygen saturation values (SpO2) were compared with arterially sampled oxygen saturation values (SaO2) during controlled hypoxemia. In vitro correlation and agreement with gas mixtures of tcPO2 (r = 0.999, bias 3.0 mm Hg, limits of agreement - 6.6 to 4.9 mm Hg) and tcPCO2 (r = 0.999, bias 0.8 mm Hg, limits of agreement - 0.7 to 2.2 mm Hg) were excellent. In vitro drift was negligible for tcPO2 (0.30 (0.63 SD) mm Hg/24 h) and highly acceptable for tcPCO2 (- 2.53 (1.04 SD) mm Hg/12 h). Clinical use in neonates showed good usability and feasibility. SpO2-SaO2 correlation (r = 0.979) and agreement (bias 0.13%, limits of agreement - 3.95 to 4.21%) in healthy adult volunteers were excellent. The investigated combined tcPO2, tcPCO2, and SpO2 sensor with a new oxygen fluorescence quenching technique is clinically usable and provides good overall accuracy and negligible tcPO2 drift. Accurate and low-drift tcPO2 monitoring offers improved measurement validity for long-term monitoring of blood and tissue oxygenation. Graphical abstract.


Assuntos
Dióxido de Carbono/sangue , Oximetria/instrumentação , Oxigênio/sangue , Pele/irrigação sanguínea , Adulto , Desenho de Equipamento , Feminino , Humanos , Recém-Nascido , Masculino , Oximetria/métodos , Adulto Jovem
4.
Anesthesiology ; 111(4): 790-804, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19741484

RESUMO

BACKGROUND: Propofol and sevoflurane display additivity for gamma-aminobutyric acid receptor activation, loss of consciousness, and tolerance of skin incision. Information about their interaction regarding electroencephalographic suppression is unavailable. This study examined this interaction as well as the interaction on the probability of tolerance of shake and shout and three noxious stimulations by using a response surface methodology. METHODS: Sixty patients preoperatively received different combined concentrations of propofol (0-12 microg/ml) and sevoflurane (0-3.5 vol.%) according to a crisscross design (274 concentration pairs, 3 to 6 per patient). After having reached pseudo-steady state, the authors recorded bispectral index, state and response entropy and the response to shake and shout, tetanic stimulation, laryngeal mask airway insertion, and laryngoscopy. For the analysis of the probability of tolerance by logistic regression, a Greco interaction model was used. For the separate analysis of bispectral index, state and response entropy suppression, a fractional Emax Greco model was used. All calculations were performed with NONMEM V (GloboMax LLC, Hanover, MD). RESULTS: Additivity was found for all endpoints, the Ce(50, PROP)/Ce(50, SEVO) for bispectral index suppression was 3.68 microg. ml(-1)/ 1.53 vol.%, for tolerance of shake and shout 2.34 microg . ml(-1)/ 1.03 vol.%, tetanic stimulation 5.34 microg . ml(-1)/ 2.11 vol.%, laryngeal mask airway insertion 5.92 microg. ml(-1) / 2.55 vol.%, and laryngoscopy 6.55 microg. ml(-1)/2.83 vol.%. CONCLUSION: For both electroencephalographic suppression and tolerance to stimulation, the interaction of propofol and sevoflurane was identified as additive. The response surface data can be used for more rational dose finding in case of sequential and coadministration of propofol and sevoflurane.


Assuntos
Anestesia , Anestésicos Inalatórios/efeitos adversos , Anestésicos Intravenosos/efeitos adversos , Éteres Metílicos/efeitos adversos , Propofol/efeitos adversos , Adolescente , Adulto , Algoritmos , Interpretação Estatística de Dados , Interações Medicamentosas , Eletroencefalografia/efeitos dos fármacos , Entropia , Feminino , Humanos , Máscaras Laríngeas , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Estudos Prospectivos , Sevoflurano , Adulto Jovem
5.
Anesth Analg ; 108(6): 1823-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19448207

RESUMO

BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. RESULTS: For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). CONCLUSIONS: Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.


Assuntos
Algoritmos , Automação , Pressão Sanguínea/fisiologia , Monitorização Intraoperatória/métodos , Abdome/cirurgia , Adulto , Idoso , Resistência das Vias Respiratórias/fisiologia , Volume Sanguíneo/fisiologia , Interpretação Estatística de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Pulso Arterial , Padrões de Referência , Reprodutibilidade dos Testes , Mecânica Respiratória/fisiologia
6.
IEEE Trans Biomed Eng ; 53(3): 387-98, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16532765

RESUMO

During general anesthesia drugs are administered to provide hypnosis, ensure analgesia, and skeletal muscle relaxation. In this paper, the main components of a newly developed controller for skeletal muscle relaxation are described. Muscle relaxation is controlled by administration of neuromuscular blocking agents. The degree of relaxation is assessed by supramaximal train-of-four stimulation of the ulnar nerve and measuring the electromyogram response of the adductor pollicis muscle. For closed-loop control purposes, a physiologically based pharmacokinetic and pharmacodynamic model of the neuromuscular blocking agent mivacurium is derived. The model is used to design an observer-based state feedback controller. Contrary to similar automatic systems described in the literature this controller makes use of two different measures obtained in the train-of-four measurement to maintain the desired level of relaxation. The controller is validated in a clinical study comparing the performance of the controller to the performance of the anesthesiologist. As presented, the controller was able to maintain a preselected degree of muscle relaxation with excellent precision while minimizing drug administration. The controller performed at least equally well as the anesthesiologist.


Assuntos
Anestésicos Gerais/administração & dosagem , Quimioterapia Assistida por Computador/métodos , Contração Muscular/efeitos dos fármacos , Contração Muscular/fisiologia , Relaxamento Muscular/efeitos dos fármacos , Relaxamento Muscular/fisiologia , Fármacos Neuromusculares/administração & dosagem , Simulação por Computador , Combinação de Medicamentos , Humanos , Modelos Biológicos , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiologia
7.
Artigo em Inglês | MEDLINE | ID: mdl-19163978

RESUMO

The ability of anesthetic agents to provide adequate analgesia and sedation is limited by the ventilatory depression associated with overdosing in spontaneously breathing patients. Therefore, quantitation of drug induced ventilatory depression is a pharmacokinetic-pharmacodynamic problem relevant to the practice of anesthesia. Although several studies describe the effect of respiratory depressant drugs on isolated endpoints, an integrated description of drug induced respiratory depression with parameters identifiable from clinically available data is not available. This study proposes a physiological model of CO2 disposition, ventilatory regulation, and the effects of anesthetic agents on the control of breathing. The predictive performance of the model is evaluated through simulations aimed at reproducing experimental observations of drug induced hypercarbia and hypoventilation associated with intravenous administration of a fast-onset, highly potent anesthetic mu agonist (including previously unpublished experimental data determined after administration of 1 mg alfentanil bolus). The proposed model structure has substantial descriptive capability and can provide clinically relevant predictions of respiratory inhibition in the non-steady-state to enhance safety of drug delivery in the anesthetic practice.


Assuntos
Alfentanil/administração & dosagem , Alfentanil/farmacocinética , Dióxido de Carbono/metabolismo , Quimioterapia Assistida por Computador/métodos , Modelos Biológicos , Mecânica Respiratória/efeitos dos fármacos , Mecânica Respiratória/fisiologia , Anestésicos Intravenosos/administração & dosagem , Simulação por Computador , Humanos , Masculino
8.
Artigo em Inglês | MEDLINE | ID: mdl-18002943

RESUMO

Drug-induced respiratory depression is a common side effect of the agents used in anesthesia practice to provide analgesia and sedation. Depression of the ventilatory drive in the spontaneously breathing patient can lead to severe cardiorespiratory events and it is considered a primary cause of morbidity. Reliable predictions of respiratory inhibition in the clinical setting would therefore provide a valuable means to improve the safety of drug delivery. Although multiple studies investigated the regulation of breathing in man both in the presence and absence of ventilatory depressant drugs, a unified description of respiratory pharmacodynamics is not available. This study proposes a mathematical model of human metabolism and cardiorespiratory regulation integrating several isolated physiological and pharmacological aspects of acute drug-induced ventilatory depression into a single theoretical framework. The description of respiratory regulation has a parsimonious yet comprehensive structure with substantial predictive capability. Simulations relative to the synergistic interaction of the hypercarbic and hypoxic respiratory drive and the global effect of drugs on the control of breathing are in good agreement with published experimental data. Besides providing clinically relevant predictions of respiratory depression, the model can also serve as a test bed to investigate issues of drug tolerability and dose finding/control under non-steady-state conditions.


Assuntos
Anestesia/efeitos adversos , Hipnóticos e Sedativos/efeitos adversos , Modelos Biológicos , Respiração/efeitos dos fármacos , Insuficiência Respiratória/metabolismo , Doença Aguda , Sistemas de Liberação de Medicamentos/efeitos adversos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Cardiopatias/etiologia , Cardiopatias/metabolismo , Humanos , Hipercapnia/induzido quimicamente , Hipercapnia/metabolismo , Hipnóticos e Sedativos/administração & dosagem , Hipóxia/induzido quimicamente , Hipóxia/metabolismo , Insuficiência Respiratória/induzido quimicamente
9.
Anesth Analg ; 101(6): 1695-1699, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16301243

RESUMO

Dantrolene is the only drug proven effective for prevention and treatment of malignant hyperthermia (MH). Current dosing recommendations are based on noncompartmental analyses and are largely empiric. They are also divergent, as evidenced by differing recommendations from the Malignant Hyperthermia Association of the United States (MHAUS) and European Sources. We determined the compartmental pharmacokinetics of dantrolene, simulated the concentration time course based on currently recommended dosing, and suggest an optimal regimen. Nine volunteers (55-89 kg) received IV infusions of dantrolene (5 mg/kg over 30 min followed by 0.05 mg.kg(-1) . h(-1) for 5 h). Venous blood samples were drawn for up to 60 h, and dantrolene plasma concentrations were determined by reverse phase, high-performance liquid chromatography. One, two, and three compartmental models were fitted to the data, and a covariate analysis was performed. All calculations were performed with NONMEM using the population approach. The data were adequately described by a two-compartment model with the following typical variable values (median +/- se): volumes of distribution V1= 3.24 +/- 0.61 L; V2= 22.9 +/- 1.53 L; plasma clearance CL el= 0.03 +/- 0.003 L/min; and distributional clearance CL dist= 1.24 +/- 0.22 L/min. All parameters were scaled linearly with weight. Simulations of European recommendations for treatment of MH lead to plasma concentrations converging to 14-18 mg/L within 24 h. Simulating MHAUS guidelines (intermittent bolus administration) yielded peak and trough plasma concentrations ranging from 6.7-22.6 mg/L. Based on our findings, we propose an infusion regimen adjusted to the initial bolus dose(s) required to control symptoms. This strategy maintains the individualized therapeutic concentrations and improves stability of plasma concentrations.


Assuntos
Dantroleno/farmacocinética , Hipertermia Maligna/tratamento farmacológico , Adulto , Simulação por Computador , Dantroleno/administração & dosagem , Feminino , Guias como Assunto , Humanos , Masculino , Hipertermia Maligna/metabolismo , Modelos Biológicos
10.
Anesthesiology ; 101(3): 591-602, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15329583

RESUMO

BACKGROUND: Automatic control of depth of hypnosis using the Bispectral Index (BIS) can help to reduce phases of inadequate control. Automated BIS control with propofol or isoflurane administration via an infusion system has recently been described, a comparable study with isoflurane administration via a vaporizer had not been conducted yet. Our hypothesis was that our new model based closed-loop control system can safely be applied clinically and maintains the BIS within a defined target range better than manual control. METHODS: Twenty-three patients, American Society of Anesthesiologists risk class I-III, scheduled for decompressive spinal surgery were randomized into groups with either closed-loop or manual control of BIS using isoflurane. An alfentanil target-controlled infusion was adjusted according to standard clinical practice. The BIS target was set to 50 during the operation. The necessity of human intervention in the control system and events of inadequate sedation (BIS <40 or BIS >60) were counted. The number of phases of inadequate control, defined as BIS >/=65 for more than 3 min, were recorded. The performance of the controller was assessed by several indicators (mean absolute deviation and median absolute performance error) and measured during the skin incision phase, the subsequent low flow phase, and the wound closure phase. Recovery profiles of both groups were compared. RESULTS: No human intervention was necessary in the closed-loop control group. The occurrence of inadequate BIS was quantified with the mean and median values of the area under the curve and amounted to 0.360 and 0.088 for the manual control group and 0.049 and 0.017 for the closed-loop control group, respectively. In the manual control group nine phases of inadequate control were recorded, compared with one in the closed-loop control group, 10.3% to 0.5% of all observed anesthesia time. During all phases the averages of the performance parameters (mean absolute deviation and median absolute performance error) were more than 30% smaller in closed-loop control than in manual control (P < 0.05 between groups). CONCLUSIONS: Closed-loop control with BIS using isoflurane can safely be applied clinically and performs significantly better than manual control, even in phases with abrupt changes of stimulation that cannot be foreseen by the control system.


Assuntos
Anestesia com Circuito Fechado/instrumentação , Anestesia por Inalação , Anestésicos Inalatórios , Eletroencefalografia/efeitos dos fármacos , Isoflurano , Adolescente , Adulto , Idoso , Algoritmos , Anestesia com Circuito Fechado/efeitos adversos , Anestesia por Inalação/efeitos adversos , Anestésicos Inalatórios/administração & dosagem , Anestésicos Inalatórios/efeitos adversos , Área Sob a Curva , Automação , Descompressão Cirúrgica , Segurança de Equipamentos , Feminino , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Isoflurano/administração & dosagem , Isoflurano/efeitos adversos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Estimulação Física , Reprodutibilidade dos Testes , Coluna Vertebral/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA