Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
At Spectrosc ; 39(3): 95-99, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32336845

RESUMO

A probing study to establish a reliable and robust method for determining the iodine concentration using the ELAN® DRC™ II ICP-MS was performed in combination with a sample digestion and filtration step. Dairy products from locally available sources were evaluated to help determine the possibility and need for further evaluations in relation to the U.S. population's iodine intake. Prior to analysis, the samples were aliquoted and digested for 3 hours at 90±3 °C. Dilution and filtration were performed, following the digestion. The sample extract was analyzed, and the results were confirmed with NIST SRM 1549a Whole Milk Powder. Further experimentation will need to be performed to optimize the method for projected sample concentration and throughput.

2.
J Infect Dis ; 214(suppl 3): S258-S262, 2016 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-27587631

RESUMO

During the Ebola virus outbreak of 2013-2016, the Viral Special Pathogens Branch field laboratory in Sierra Leone tested approximately 26 000 specimens between August 2014 and October 2015. Analysis of the B2M endogenous control Ct values showed its utility in monitoring specimen quality, comparing results with different specimen types, and interpretation of results. For live patients, blood is the most sensitive specimen type and oral swabs have little diagnostic utility. However, swabs are highly sensitive for diagnostic testing of corpses.


Assuntos
Surtos de Doenças , Ebolavirus/isolamento & purificação , Doença pelo Vírus Ebola/diagnóstico , RNA Viral/análise , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Serviços de Laboratório Clínico , Ebolavirus/genética , Doença pelo Vírus Ebola/epidemiologia , Doença pelo Vírus Ebola/virologia , Humanos , Laboratórios , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade , Serra Leoa/epidemiologia
3.
J Anal At Spectrom ; 2014(2): 297-303, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26229219

RESUMO

Biomonitoring and emergency response measurements are an important aspect of the Division of Laboratory Sciences of the National Center for Environmental Health, Centers for Disease Control and Prevention (CDC). The continuing advancement in instrumentation allows for enhancements to existing analytical methods. Prior to this work, chromium and nickel were analyzed on a sector field inductively coupled plasma-mass spectrometer (SF-ICP-MS). This type of instrumentation provides the necessary sensitivity, selectivity, accuracy, and precision but due to the higher complexity of instrumentation and operation, it is not preferred for routine high throughput biomonitoring needs. Instead a quadrupole based method has been developed on a PerkinElmer NexION™ 300D ICP-MS. The instrument is operated using 6.0 mL min-1 helium as the collision cell gas and in kinetic energy discrimination mode, interferences are successfully removed for the analysis of 52Cr (40Ar12C and 35Cl16O1H) and 60Ni (44Ca16O). The limits of detection are 0.162 µg L-1 Cr and 0.248 µg L-1 Ni. Method accuracy using NIST SRM 2668 level 1 (1.08 µg L-1 Cr and 2.31µg L-1 Ni) and level 2 (27.7 µg L-1 Cr and 115 µg L-1 Ni) was within the 95% confidence intervals reported in the NIST certificate. Among-run precision is less than 10% RSDs (N = 20) for in house quality control and NIST SRM urine samples. While the limits of detection (LOD) for the new quadrupole ICP-UCT-MS with KED method are similar to the SF-ICP-MS method, better measurement precision is observed for the quadrupole method. The new method presented provides fast, accurate, and more precise results on a less complex and more robust ICP-MS platform.

4.
J Radioanal Nucl Chem ; 299(3): 1555-1563, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26300575

RESUMO

A newly developed procedure for determination of arsenic by radiochemical neutron activation analysis (RNAA) was used to measure arsenic at four levels in SRM 955c Toxic Elements in Caprine Blood and at two levels in SRM 2668 Toxic Elements in Frozen Human Urine for the purpose of providing mass concentration values for certification. Samples were freeze-dried prior to analysis followed by neutron irradiation for 3 h at a fluence rate of 1×1014cm-2s-1. After sample dissolution in perchloric and nitric acids, arsenic was separated from the matrix by extraction into zinc diethyldithiocarbamate in chloroform, and 76As quantified by gamma-ray spectroscopy. Differences in chemical yield and counting geometry between samples and standards were monitored by measuring the count rate of a 77As tracer added before sample dissolution. RNAA results were combined with inductively coupled plasma - mass spectrometry (ICP-MS) values from NIST and collaborating laboratories to provide certified values of (10.81 ± 0.54) µg/kg and (213.1 ± 0.73) µg/kg for SRM 2668 Levels I and II, and certified values of (21.66 ± 0.73) µg/kg, (52.7 ± 1.1) µg/kg, and (78.8 ± 4.9) µg/kg for SRM 955c Levels 2, 3, and 4 respectively. Because of discrepancies between values obtained by different methods for SRM 955c Level 1, an information value of < 5 µg/kg was assigned for this material.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA