RESUMO
Painful benign bone tumors most commonly affect pediatric patients and young adults. They may be associated with skeletal-related events such as intractable pain, pathologic fracture, neurologic deficit as a consequence of nerve or spinal cord compression, as well as growth disturbance. Consequently, they often result in diminished activity and adversely affect quality of life. There have been substantial recent advances in percutaneous minimally invasive image-guided interventions for treatment of painful benign bone tumors including thermal ablation (radiofrequency ablation, cryoablation, microwave ablation, laser photocoagulation, and high-intensity focused US ablation), chemical (alcohol) ablation, cementoplasty, and intralesional injections. The safety, efficacy, and durability of such interventions have been established in the recent literature and as such, the role of musculoskeletal interventional radiologists in the care of patients with benign bone lesions has substantially expanded. The treatment goal of minimally invasive musculoskeletal interventions in patients with benign bone tumors is to achieve definitive cure. The authors detail the most recent advances and available armamentarium in minimally invasive image-guided percutaneous interventions with curative intent for the management of benign bone tumors. © RSNA, 2022.
Assuntos
Neoplasias Ósseas , Ablação por Cateter , Criocirurgia , Humanos , Criança , Qualidade de Vida , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Dor , EtanolRESUMO
OBJECTIVES: Our previous published studies have focused on safety and effectiveness of using therapeutic ultrasound (TUS) for treatment of type 2 diabetes mellitus (T2DM) in preclinical models. Here we present a set of simulation studies to explore potential ultrasound application schemes that would be feasible in a clinical setting. METHODS: Using the multiphysics modeling tool OnScale, we created two-dimensional (2D) models of the human abdomen from CT images captured from one normal weight adolescent patient, and one obese adolescent patient. Based on our previous studies, the frequency of our TUS was 1 MHz delivered from a planar unfocused transducer. We tested five different insonation angles, as well as four ultrasound intensities combined with four different duty factors and five durations of application to explore how these variables effect the peak pressure and temperature delivered to the pancreas as well as surrounding tissue in the model. RESULTS: We determined that ultrasound applied directly from the anterior of the patient abdomen at 5 W/cm2 delivered consistent acoustic pressures to the pancreas at the levels which we have previously found to be effective at inducing an insulin release from preclinical models. CONCLUSIONS: Our modeling work indicates that it may be feasible to non-invasively apply TUS in clinical treatment of T2DM.
Assuntos
Cavidade Abdominal , Diabetes Mellitus Tipo 2 , Obesidade Infantil , Humanos , Adolescente , Insulina/uso terapêutico , Pâncreas/diagnóstico por imagemRESUMO
OBJECTIVE: Gastrostomy tubes (G-tubes) provide long-term feeding assistance to children with severe feeding dysfunction. Although there are a host of complications that occur at home with current pediatric G-tube feeding, their prevalences and outcomes remain relatively unstudied. This study aims to identify and describe such complications. METHODS: A dual-round survey was administered to 98 participants through the Feeding Tube Awareness Foundation, a 501(c)(3) organization that supports parents and caretakers of G-tube-fed children. Information was collected broadly regarding G-tube complications, causes, and attitudes toward such complications. RESULTS: Infection (56%), itching/irritation/redness (52%), and leakage (51%) were the leading G-tube related complications. The average time that G-tubes were replaced was 3.4 ± 1.2 months as compared to the typical recommended period of up to 6 months. Of the caretakers who had not experienced G-tube displacement, 7.9% wanted to see a change in current G-tubes to address the issue, compared with 75% of those who had experienced displacement. This 67.1% differential in caretakers' attitudes toward G-tubes based on their prior experience with a particular complication was the largest gap among all other listed complications. CONCLUSIONS: G-tube complications are prevalent and varied. A sizable portion of G-tube users experience complications severe enough to require intervention. Of these, G-tube displacement is particularly critical and frequently precedes other prevalent complications, namely gastric leakage, infection, and tissue granulation.
Assuntos
Gastrostomia , Intubação Gastrointestinal , Criança , Nutrição Enteral/efeitos adversos , Gastrostomia/efeitos adversos , Humanos , Intubação Gastrointestinal/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , EstômagoRESUMO
INTRODUCTION: This paper reports the system integration and cadaveric assessment of a body-mounted robotic system for MRI-guided lumbar spine injections. The system is developed to enable MR-guided interventions in closed bore magnet and avoid problems due to patient movement during cannula guidance. MATERIAL AND METHODS: The robot is comprised by a lightweight and compact structure so that it can be mounted directly onto the lower back of a patient using straps. Therefore, it can minimize the influence of patient movement by moving with the patient. The MR-Conditional robot is integrated with an image-guided surgical planning workstation. A dedicated clinical workflow is created for the robot-assisted procedure to improve the conventional freehand MRI-guided procedure. RESULTS: Cadaver studies were performed with both freehand and robot-assisted approaches to validate the feasibility of the clinical workflow and to assess the positioning accuracy of the robotic system. The experiment results demonstrate that the root mean square (RMS) error of the target position to be 2.57 ± 1.09 mm and of the insertion angle to be 2.17 ± 0.89°. CONCLUSION: The robot-assisted approach is able to provide more accurate and reproducible cannula placements than the freehand procedure, as well as to reduce the number of insertion attempts.
Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cadáver , Humanos , Injeções Espinhais , Imageamento por Ressonância MagnéticaRESUMO
Certain technical criteria must be met to ensure the treatment safety of magnetic resonance-guided high-intensity focused ultrasound. We retrospectively reviewed how our enrollment criteria were applied from 2014 to 2017 in a clinical trial of magnetic resonance-guided high-intensity focused ultrasound ablation of recurrent malignant and locally aggressive benign solid tumors. Among the 36 screened patients between 2014 and 2017, more than one-third were excluded for technical exclusion criteria such as the anatomic location and proximity to prosthetics. Overall, patients were difficult to accrue for this trial, given the incidence of these tumors. To increase potential accrual, screening exclusion criteria could be more generalized and centered on the ability to achieve an acceptable treatment safety margin, rather than specifically excluding on the basis of general anatomic areas.
Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Hospitais Pediátricos , Criança , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos RetrospectivosRESUMO
HIGHLIGHTS: Ultrasound shows several venous changes in pediatric PIV-containing veins. Changes were visualized by ultrasound in the absence of physical exam findings. Venous luminal narrowing, wall thickening, and thrombosis may explain PIV failure. BACKGROUND: Peripheral intravenous catheters (PIVs) are routinely used for venous access in hospitalized pediatric patients to administer fluids and medications and to aspirate blood. Unfortunately, PIVs do not remain functional for the entire duration of intravascular need. We hypothesized that PIV malfunction may be related to venous changes that can be visualized with ultrasound (US) imaging. The purpose of this study was to describe and document such changes in pediatric patients. METHODS: This Institutional Review Board-approved study was performed at a tertiary pediatric medical center. Patients underwent US scans of their PIV-containing veins, documenting venous characteristics such as depth, diameter, wall thickness, blood flow, valves, branch points, and presence of thrombus. Patient demographics and PIV characteristics were also recorded. RESULTS: Data from 30 patients including 12 males and 18 females with a mean age of 11 years were analyzed. Mean venous depth and diameter were 2.07 ± 0.13 and 2.02 ± 0.18 mm, respectively. Mean PIV dwell time at time of evaluation was 3.3 days. PIV-associated venous changes were seen in 73% of accessed veins and included lumen narrowing (47%), wall thickening (33%), presence of thrombus (20%), and absence of blood flow around the PIV tip (40%). CONCLUSION: PIV-associated venous changes are seen with US in the majority of pediatric patients with indwelling PIVs but are not necessarily appreciated on physical exam. These changes may help explain the high rate of pediatric PIV device failure. Given the small sample size, further investigation is needed to better characterize PIV-associated venous changes in children.
Assuntos
Cateterismo Periférico/métodos , Veias/diagnóstico por imagem , Criança , Falha de Equipamento , Feminino , Humanos , Infusões Intravenosas , Masculino , UltrassonografiaRESUMO
OBJECTIVE: To describe the incidence and characteristics of central venous catheter (CVC)-related thrombosis in hospitalized pediatric patients with active inflammatory bowel disease (IBD) and report the potential usefulness of anticoagulant thromboprophylaxis (AT). STUDY DESIGN: We conducted a retrospective study of patients who were admitted to our children's hospital in the last 2 years with active IBD and required a CVC and identified all patients with an objectively confirmed symptomatic CVC-related thrombosis. To assess the usefulness of a recently implemented institutional AT protocol, we compared the frequency of CVC-related thrombosis, nadir hemoglobin, and red blood cell transfusion requirements in patients who received AT with those who did not during the study period. RESULTS: A total of 40 patients with IBD who required 47 consecutive hospitalizations were included. AT was administered during 24 of 47 hospitalizations (51%). Patients who received AT were similar to those who did not receive AT with regard to demographics, IBD phenotypes, extent of colonic involvement, and thrombotic risk factors. CVC-related thrombosis occurred in 5 of 23 hospitalizations (22%) in which AT was withheld compared with 0 of 24 hospitalizations (0%) in which patients received AT (P = .02). The red blood cell transfusion requirements and nadir hemoglobin were not significantly different between the 2 groups. CONCLUSIONS: We observed a high incidence of CVC-related thrombosis in hospitalized children with IBD. Administration of AT in our population was associated with significant reduction in CVC-related thrombosis without evidence of increased bleeding.
Assuntos
Anticoagulantes/uso terapêutico , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Enoxaparina/uso terapêutico , Doenças Inflamatórias Intestinais/terapia , Trombose Venosa/epidemiologia , Adolescente , Criança , Feminino , Hospitalização , Humanos , Incidência , Masculino , Estudos Retrospectivos , Trombose Venosa/prevenção & controleRESUMO
This review describes the historical development of an imageable spherical embolic agent and focuses on work performed in collaboration between Biocompatibles UK Ltd (a BTG International group company) and the NIH to demonstrate radiopaque bead utility and bring a commercial offering to market that meets a clinical need. Various chemistries have been investigated and multiple prototypes evaluated in search of an optimized product with the right balance of handling and imaging properties. Herein, we describe the steps taken in the development of DC Bead LUMI™, the first commercially available radiopaque drug-eluting bead, ultimately leading to the first human experience of this novel embolic agent in the treatment of liver tumors.
Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Quimioembolização Terapêutica/métodos , Portadores de Fármacos/química , Desenvolvimento de Medicamentos , Neoplasias Hepáticas/terapia , Animais , Quimioembolização Terapêutica/instrumentação , Meios de Contraste/química , Modelos Animais de Doenças , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Microesferas , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
BACKGROUND: Osteoid osteoma (OO) is a painful bone tumour occurring in children and young adults. Magnetic resonance imaging-guided high intensity focussed ultrasound (MR-HIFU) allows non-invasive treatment without ionising radiation exposure, in contrast to the current standard of care treatment with radiofrequency ablation (RFA). This report describes technical aspects of MR-HIFU ablation in the first 8 paediatric OO patients treated in a safety and feasibility clinical trial (total enrolment of up to 12 patients). MATERIALS AND METHODS: OO lesions and adjacent periosteum were treated with MR-HIFU ablation in 5-20 sonications (sonication duration = 16-48 s, frequency = 1.2 MHz, acoustic power = 20-160 W). Detailed treatment workflow, patient positioning and coupling strategies, as well as temperature and tissue perfusion changes were summarised and correlated. RESULTS: MR-HIFU ablation was feasible in all eight cases. Ultrasound standoff pads were shaped to conform to extremity contours providing acoustic coupling and aided patient positioning. The energy delivered was 10 ± 7 kJ per treatment, raising maximum temperature to 83 ± 3 °C. Post ablation contrast-enhanced MRI showed ablated volumes ranging 0.46-19.4 cm3 extending further into bone (7 ± 4 mm) than into soft tissue (4 ± 6 mm, p = 0.01, Mann-Whitney). Treatment time ranged 30-86 min for sonication and 160 ± 40 min for anaesthesia. No serious treatment-related adverse events were observed. Complete pain relief with no medication occurred in 7/8 patients within 28 days following treatment. CONCLUSIONS: MR-HIFU ablation of painful OO appears technically feasible in children and it may become a non-invasive and radiation-free alternative for painful OO. Therapy success, efficiency, and applicability may be improved through specialised equipment designed more specifically for extremity bone ablation.
Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Imagem por Ressonância Magnética Intervencionista/métodos , Osteoma Osteoide/diagnóstico por imagem , Adolescente , Adulto , Criança , Feminino , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Masculino , Osteoma Osteoide/patologia , Osteoma Osteoide/terapia , Adulto JovemRESUMO
PURPOSE: High intensity focussed ultrasound (HIFU) can non-invasively treat tumours with minimal or no damage to intervening tissues. While continuous-wave HIFU thermally ablates target tissue, the effect of hundreds of microsecond-long pulsed sonications is examined in this work. The objective of this study was to characterise sonication parameter-dependent thermomechanical bioeffects to provide the foundation for future preclinical studies and facilitate clinical translation. METHODS AND MATERIALS: Acoustic power, number of cycles/pulse, sonication time and pulse repetition frequency (PRF) were varied on a clinical magnetic resonance imaging (MRI)-guided HIFU (MR-HIFU) system. Ex vivo porcine liver, kidney and cardiac muscle tissue samples were sonicated (3 × 3 grid pattern, 1 mm spacing). Temperature, thermal dose and T2 relaxation times were quantified using MRI. Lesions were histologically analysed using H&E and vimentin stains for lesion structure and viability. RESULTS: Thermomechanical HIFU bioeffects produced distinct types of fractionated tissue lesions: solid/thermal, paste-like and vacuolated. Sonications at 20 or 60 Hz PRF generated substantial tissue damage beyond the focal region, with reduced viability on vimentin staining, whereas H&E staining indicated intact tissue. Same sonication parameters produced dissimilar lesions in different tissue types, while significant differences in temperature, thermal dose and T2 were observed between the parameter sets. CONCLUSION: Clinical MR-HIFU system was utilised to generate distinct types of lesions and to produce targeted thermomechanical bioeffects in ex vivo tissues. The results guide HIFU research on thermomechanical tissue bioeffects, inform future studies and advice sonication parameter selection for direct tumour ablation or immunomodulation using a clinical MR-HIFU system.
Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Imageamento por Ressonância Magnética , Animais , Procedimentos Cirúrgicos Cardíacos , Coração/diagnóstico por imagem , Rim/diagnóstico por imagem , Rim/cirurgia , Fígado/diagnóstico por imagem , Fígado/cirurgia , Sonicação , SuínosRESUMO
OBJECTIVE: To evaluate clinical feasibility and safety of magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic osteoid osteoma and to compare clinical response with standard of care treatment. STUDY DESIGN: Nine subjects with radiologically confirmed, symptomatic osteoid osteoma were treated with MR-HIFU in an institutional review board-approved clinical trial. Treatment feasibility and safety were assessed. Clinical response was evaluated in terms of analgesic requirement, visual analog scale pain score, and sleep quality. Anesthesia, procedure, and recovery times were recorded. This MR-HIFU group was compared with a historical control group of 9 consecutive patients treated with radiofrequency ablation. RESULTS: Nine subjects (7 male, 2 female; 16 ± 6 years) were treated with MR-HIFU without technical difficulties or any serious adverse events. There was significant decrease in their median pain scores 4 weeks within treatment (6 vs 0, P < .01). Total pain resolution and cessation of analgesics were achieved in 8 of 9 patients after 4 weeks. In the radiofrequency ablation group, 9 patients (8 male, 1 female; 10 ± 6 years) were treated in routine clinical practice. All 9 demonstrated complete pain resolution and cessation of medications by 4 weeks with a significant decrease in median pain scores (9 vs 0, P < .001). One developed a second-degree skin burn, but there were no other adverse events. Procedure times and treatment charges were comparable between the 2 groups. CONCLUSION: This pilot study shows that MR-HIFU treatment of osteoid osteoma refractory to medical therapy is feasible and can be performed safely in pediatric patients. Clinical response is comparable with standard of care treatment but without any incisions or exposure to ionizing radiation. TRIAL REGISTRATION: ClinicalTrials.govNCT02349971.
Assuntos
Neoplasias Ósseas/cirurgia , Ablação por Cateter , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imagem por Ressonância Magnética Intervencionista , Osteoma Osteoide/cirurgia , Adolescente , Neoplasias Ósseas/diagnóstico por imagem , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Osteoma Osteoide/diagnóstico por imagem , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Adulto JovemAssuntos
Hematometra , Vagina , Feminino , Humanos , Vagina/diagnóstico por imagem , Vagina/anormalidades , Drenagem , Ultrassonografia de IntervençãoRESUMO
Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70-150-µm radiopaque microspheres in saline (radiopaque microsphere group), 70-150-µm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70-150-µm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. (©) RSNA, 2015.
Assuntos
Embolização Terapêutica , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Animais , Tomografia Computadorizada de Feixe Cônico , Meios de Contraste , Óleo Etiodado , Neoplasias Hepáticas Experimentais/irrigação sanguínea , Masculino , Microesferas , Tomografia Computadorizada Multidetectores , Imagem Multimodal , CoelhosRESUMO
PURPOSE: To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints. MATERIALS AND METHODS: Rabbit Vx2 liver tumors were embolized with 100-300-µm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint. Tumor microvasculature was labeled with an anti-CD31 antibody and analyzed with fluorescence microscopy for perfusion marker overlap/mismatch. Data were analyzed by analysis of variance and post hoc test (n = 3-5 per group; 18 total). RESULTS: Mean microvascular density was 70 vessels/mm(2) ± 17 (standard error of the mean), and 81% ± 1 of microvasculature (ie, CD31(+) structures) was functionally perfused within viable Vx2 tumor regions. Embolization to the extent of substasis eliminated perfusion in 37% ± 9 of perfused microvessels (P > .05 vs baseline), whereas embolization to the extent of angiographic stasis eliminated perfusion in 56% ± 8 of perfused microvessels. Persistent microvascular perfusion following embolization was predominantly found in the tumor periphery, adjacent to normal tissue. Newly perfused microvasculature was evident following embolization to substasis but not when embolization was performed to complete angiographic stasis. CONCLUSIONS: Nearly half of tumor microvasculature remained patent despite embolization to complete angiographic stasis. The observed preservation of tumor microvasculature perfusion with angiographic endpoints of substasis and stasis may have implications for tumor response to embolotherapy.
Assuntos
Embolização Terapêutica , Neoplasias Hepáticas Experimentais/irrigação sanguínea , Neoplasias Hepáticas Experimentais/terapia , Microvasos , Análise de Variância , Animais , Microscopia de Fluorescência , CoelhosRESUMO
PURPOSE: To develop a simple method to produce radiopaque drug-eluting microspheres (drug-eluting beads [DEBs]) that could be incorporated into the current clinical transcatheter arterial chemoembolization workflow and evaluate their performance in vitro and in vivo. MATERIALS AND METHODS: An ethiodized oil (Lipiodol; Guerbet, Villepinte, France) and ethanol solution was added to a lyophilized 100-300 µm bead before loading with doxorubicin. These radiopaque drug-eluting beads (DEBs; Biocompatibles UK Ltd, Farnham, United Kingdom) were evaluated in vitro for x-ray attenuation, composition, size, drug loading and elution, and correlation between attenuation and doxorubicin concentration. In vivo conspicuity was evaluated in a VX2 tumor model. RESULTS: Lipiodol was loaded into lyophilized beads using two glass syringes and a three-way stopcock. Maximum bead attenuation was achieved within 30 minutes. X-ray attenuation of radiopaque beads increased linearly (21-867 HU) with the amount of beads (0.4-12.5 vol%; R(2) = 0.9989). Doxorubicin loading efficiency and total amount eluted were similar to DC Bead (Biocompatibles UK Ltd); however, the elution rate was slower for radiopaque DEBs (P < .05). Doxorubicin concentration linearly correlated with x-ray attenuation of radiopaque DEBs (R(2) = 0. 99). Radiopaque DEBs were seen in tumor feeding arteries after administration by fluoroscopy, computed tomography, and micro-computed tomography, and their location was confirmed by histology. CONCLUSIONS: A simple, rapid method to produce radiopaque DEBs was developed. These radiopaque DEBs provided sufficient conspicuity to be visualized with x-ray imaging techniques.
Assuntos
Quimioembolização Terapêutica/instrumentação , Portadores de Fármacos , Neoplasias Hepáticas Experimentais/terapia , Microesferas , Animais , Modelos Animais de Doenças , Doxorrubicina/administração & dosagem , Óleo Etiodado/administração & dosagem , Fígado/diagnóstico por imagem , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Imagens de Fantasmas , Coelhos , Microtomografia por Raio-XRESUMO
Clinical use of DC Bead™ loaded with doxorubicin (DEBDOX™) or irinotecan (DEBIRI™), for the treatment of primary and secondary tumours of the liver respectively, is showing great promise. Recently there has been a tendency to select smaller bead size ranges to treat tumours in an effort to allow more drug dose to be administered, improve tumoural penetration and resultant drug delivery and tumour coverage. Herein we describe the development and performance characterisation of a new DC Bead size range (DC BeadM1 (TM), 70-150 µm) capable of an increased bead delivery in the distal vasculature, corresponding to greater tumour coverage and drug dose delivered. Both unloaded and drug loaded DC BeadM1 were shown to have a greater density of distal volume of penetration although the ultimate distal level of penetration was the same as that of the 100-300 µm beads in an in vitro penetration model. Elution of doxorubicin was slower than irinotecan elution, but it was similar when comparing the same drug elution from 70 to 150 µm compared to 100-300 µm beads. Radiopaque versions of 70-150 and 100-300 µm beads were prepared in order to evaluate distribution ex vivo using µ-CT and doxorubicin distribution using epifluorescent microscopy. Liver distribution of the radiopaque versions of the beads was shown to be more distal and efficient at filling smaller vessels with the DC BeadM1 and correspondingly more beads were found per vessel histologically with a larger area of drug coverage with the smaller size range. This study indicates that the smaller (70-150 µm) beads should permit an increased dose of drug to be administered to both hypervascular and hypovascular tumours as compared to 100-300 µm beads.
Assuntos
Antineoplásicos/administração & dosagem , Camptotecina/análogos & derivados , Catéteres , Doxorrubicina/administração & dosagem , Portadores de Fármacos , Neoplasias Hepáticas Experimentais/tratamento farmacológico , Animais , Antineoplásicos/farmacocinética , Camptotecina/administração & dosagem , Camptotecina/farmacocinética , Doxorrubicina/farmacocinética , Irinotecano , Coelhos , Microtomografia por Raio-XRESUMO
PURPOSE: To evaluate the effect of embolic diameter on achievement of hypoxia after embolization in an animal model of liver tumors. MATERIALS AND METHODS: Inoculation of VX2 tumors in the left liver lobe was performed successfully in 12 New Zealand white rabbits weighing 3.7 kg ± 0.5 (mean ± SD). Tumors were deemed eligible for oxygen measurements when the maximum transverse diameter measured 15 mm or more by ultrasound examination. Direct monitoring of oxygenation of implanted rabbit hepatic VX2 tumors was performed with a fiberoptic electrode during and after transarterial embolization of the proper hepatic artery to angiographic flow stasis with microspheres measuring 70-150 µm, 100-300 µm, or 300-500 µm in diameter. RESULTS: Failure to achieve tumor hypoxia as defined despite angiographic flow stasis was observed in 10 of 11 animals. Embolization microsphere size effect failed to demonstrate a significant trend on hypoxia outcome among the diameters tested, and pair-wise comparisons of different embolic diameter treatment groups showed no difference in hypoxia outcome. All microsphere diameters tested resulted in similar absolute reduction (24.3 mm Hg ± 18.3, 29.1 mm Hg ± 1.8, and 19.9 mm Hg ± 9.3, P = .66) and percentage decrease in oxygen (56.0 mm Hg ± 23.9, 56.0 mm Hg ± 6.4, and 35.8 mm Hg ± 20.6, P = .65). Pair-wise comparisons for percent tumor area occupied by embolic agents showed a significantly reduced fraction for 300-500 µm diameters compared with 70-150 µm diameters (P < .05). CONCLUSIONS: In the rabbit VX2 liver tumor model, three tested microsphere diameters failed to cause tumor hypoxia as measured by a fiberoptic probe sensor according to the adopted hypoxia definitions.
Assuntos
Quimioembolização Terapêutica/métodos , Hemostáticos/administração & dosagem , Hemostáticos/química , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/terapia , Oxigênio/metabolismo , Animais , Hipóxia Celular , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Feminino , Neoplasias Hepáticas/diagnóstico por imagem , Microesferas , Tamanho da Partícula , Coelhos , Resultado do Tratamento , UltrassonografiaRESUMO
BACKGROUND: Clinical efficacy of thrombolytic drugs is limited by lack of specific delivery and requires large therapeutic doses which increase toxicity. Encapsulating these drugs in temperature-sensitive liposomes and applying hyperthermia to deliver thrombolytic agents locally to thrombus might theoretically favourably alter the therapeutic window. The objectives of this study were to formulate liposomes encapsulating thrombolytics and assess thrombolytic activity following hyperthermia. METHODS: Three liposome formulations were investigated: temperature-sensitive liposome (TSL, DPPC:DSPE-PEG2000 (mol% 95:5)), low temperature-sensitive liposome (LTSL, DPPC:MSPC:DSPE-PEG2000 (mol% 85.3:9.7:5)), and traditional temperature-sensitive liposome (TTSL, DPPC:HSPC:Chol:DSPE-PEG2000 (mol% 55:25:15:5)). To characterise temperature-dependent release of high molecular weight cargo from each formulation, fluorescein-conjugated dextrans (70 kDa) were loaded and release was quantified via spectrophotometry. Staphylokinase (SAK), urokinase, and tissue-type plasminogen activator were also loaded individually into each liposome formulation. Leakage at 37 °C and release at 38-44 °C were quantified via chromogenic enzymatic activity assay. Clot lysis was evaluated by measuring mass of blood clots before and after thrombolytic liposome treatment. RESULTS: The LTSL formulation had optimal release characteristics with maximum release at 41.3 °C. Release of dextrans from LTSLs was observed to be 11.5 ± 1.5%, 79.7 ± 1.6%, and 93.6 ± 3.7% after 15 min in plasma at 37°, 39°, and 41.3 °C, respectively. The SAK LTSL had the highest release/leakage ratio and demonstrated greater clot lysis. CONCLUSIONS: The SAK LTSL achieves significant clot lysis in vitro. When combined with local hyperthermia, the SAK LTSL potentially produces sufficient thrombolysis while minimising systemic side effects.
Assuntos
Coagulação Sanguínea/efeitos dos fármacos , Fibrinolíticos/administração & dosagem , Metaloendopeptidases/administração & dosagem , Ativador de Plasminogênio Tecidual/administração & dosagem , Ativador de Plasminogênio Tipo Uroquinase/administração & dosagem , Humanos , Hipertermia Induzida , Lipídeos/química , Lipossomos , Masculino , Metaloendopeptidases/química , Polietilenoglicóis/química , Temperatura , Ativador de Plasminogênio Tecidual/química , Ativador de Plasminogênio Tipo Uroquinase/químicaRESUMO
Therapeutic embolization of blood vessels is a minimally invasive, catheter-based procedure performed with solid or liquid emboli to treat bleeding, vascular malformations, and vascular tumors. Hepatocellular carcinoma (HCC) affects about half a million people per year. When unresectable, HCC is treated with embolization and local drug therapy by transarterial chemoembolization (TACE). For TACE, drug eluting beads (DC Bead(®)) may be used to occlude or reduce arterial blood supply and deliver chemotherapeutics locally to the tumor. Although this treatment has been shown to be safe and to improve patient survival, the procedure lacks imaging feedback regarding the location of embolic agent and drug coverage. To address this shortcoming, herein we report the synthesis and characterization of image-able drug eluting beads (iBeads) from the commercial DC Bead(®) product. Two different radiopaque beads were synthesized. In one approach, embolic beads were conjugated with 2,3,5-triiodobenzyl alcohol in the presence of 1,1'-carbonyldiimidazol to give iBead I. iBead II was synthesized with a similar approach but instead using a trimethylenediamine spacer and 2,3,5-triiodobenzoic acid. Doxorubicin was loaded into the iBeads II using a previously reported method. Size and shape of iBeads were evaluated using an upright microscope and their conspicuity assessed using a clinical CT and micro-CT. Bland and Dox-loaded iBeads II visualized with both clinical CT and microCT. Under microCT, individual bland and Dox loaded beads had a mean attenuation of 7904 ± 804 and 11,873.96 ± 706.12 HU, respectively. These iBeads have the potential to enhance image-guided TACE procedures by providing localization of embolic-particle and drug.