RESUMO
The problem of resolution enhancement for speckle patterns analysis-based movement estimation is considered. In our previous publications we showed that this movement represents the corresponding tilt vibrations of the illuminated object and can be measured as a relative spatial shift between time adjacent images of the speckle pattern. In this paper we show how to overcome the resolution limitation obtained when using an optical sensor available in an optical mouse and which measures the Cartesian coordinates of the shift as an integer number of pixels. To overcome such a resolution limitation, it is proposed here to use simultaneous measurements from the same illuminated spot by a few cameras (sensors) each having imaging lenses with different amounts of defocusing. The amount of defocusing defines the proportion ratio between actual changes in the tilt plane and measured shift between speckle images. To utilize the diversity of such ratios we apply a beam-forming signal processing approach that makes it possible to achieve different design criteria and improve the measurement accuracy, respectively. The validity and properties of the proposed solution are demonstrated by a few examples of in-vivo touchless measurements of human heart beat sounds.
RESUMO
BACKGROUND: The cost of heart failure hospitalizations in the US alone is over USD 10 billion per year. Over 4 million Americans are hospitalized every year due to heart failure (HF), with a median length of stay of 4 days and an in-hospital mortality rate that exceeds 5%. Hospitalizations of patients with HF can be prevented by early detection of lung congestion. Our study assessed a new contact-free optical medical device used for the early detection of lung congestion. METHODS: The Gili system is an FDA-cleared device used for measuring chest motion vibration data. Lung congestion in the study was assessed clinically and verified via two cardiologists. An algorithm was developed using machine learning techniques, and cross-validation of the findings was performed to estimate the accuracy of the algorithm. RESULTS: A total of 227 patients were recruited (101 cases vs. 126 controls). The sensitivity and specificity for the device in our study were 0.91 (95% CI: 0.86-0.93) and 0.91 (95% CI: 0.87-0.94), respectively. In all instances, the observed estimates of PPVs and NPVs were at least 0.82 and 0.90, respectively. The accuracy of the algorithm was not affected by different covariates (including respiratory or valvular conditions). CONCLUSIONS: This study demonstrates the efficacy of a contact-free optical device for detecting lung congestion. Further validation of the study results across a larger and precise scale is warranted.