Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Indian J Plast Surg ; 49(1): 95-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27274130

RESUMO

Double free-flaps are necessary when tissue cover cannot be sufficed with a single flap. The other factors to be considered when using two free flaps for resurfacing of distal limb defects are the availability of more than one recipient vessel, the risk of distal limb ischaemia and the donor site morbidity of double flap harvest. If these factors are adequately addressed, double free-flaps can be safely executed for resurfacing distal limb defects with minimal morbidity. We report the simultaneous harvest and transfer of the anterolateral and anteromedial thigh flaps inset and vascularised as double free-flaps to resurface a large bimalleolar defect in a 14-year-old boy with no additional morbidity as compared to that of a single free tissue transfer.

2.
Indian J Ophthalmol ; 72(4): 549-553, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546469

RESUMO

PURPOSE: To compare the accuracy of nine conventional and newer-generation formulae in calculating intraocular lens power in eyes with axial myopia. SETTING: Tertiary eye care center, Bengaluru, India. DESIGN: Retrospective cross-sectional, comparative study conducted in India. METHODS: Patients undergoing uneventful phacoemulsification in eyes with axial length >26 mm were included. Preoperative biometry was done using Lenstar LS 900 (Haag-Streit AG, Switzerland). Single eye of patients undergoing bilateral implantation was randomly selected. Optimized lens constants were used to calculate the predicted postoperative refraction of each formula, which was then compared with the actual refractive outcomes to give the prediction errors, following which subgroup analysis was performed. The Kane formula, Barrett universal II, Emmetropia Verifying Optical (EVO) 2.0, Hill Radial Basis Function (Hill RBF) 3.0, Olsen formula, along with Wang Koch-adjusted four formulae, that is, Sanders Retzlaff Kraff/Theoretical (SRK/T), Holladay 1, Haigis, and Hoffer Q formula, were compared for intraocular lens power calculations. RESULTS: One hundred and sixty-five eyes that fulfilled all the inclusion criteria were studied. Hill RBF 3.0 had the lowest mean and median absolute prediction errors (0.355 and 0.275, respectively) compared to all formulas. In subgroup analysis (26-28, >28-30, and >30 mm), significant difference was seen only in extremely long eyes (>30 mm). The Hill RBF 3.0 formula generated the maximum percentage of eyes with refractive errors within ±0.25, ±0.5, ±0.75, and ±1 D (46%, 76.2%, 89.9%, and 95.8%, respectively). CONCLUSION: This is the first study evaluating all the formulas exclusively in the myopic eyes. Hill RBF 3 was found to be superior in accuracy to all other formulas.


Assuntos
Lentes Intraoculares , Miopia , Humanos , Estudos Transversais , Olho , Miopia/diagnóstico , Miopia/cirurgia , Estudos Retrospectivos
3.
Indian J Ophthalmol ; 72(1): 56-62, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38131570

RESUMO

PURPOSE: To compare the ease of visualization and comfort of the surgeon during phacoemulsification surgery using NGENUITY® 3D (NG) visualization system and standard operating microscope (SOM). METHODS: In this prospective, randomized, single-blind, single-center study, patients undergoing phacoemulsification surgery by one of the five surgeons were randomly assigned to two groups based on the visualization modality-NG and SOM. Ease of visualization and comfort of the surgeon was assessed using a 27-parameter in-house Surgeon Comfort Score questionnaire. RESULTS: A total of 224 phacoemulsification with intraocular lens implantations were performed in senile immature cataract (SIMC, n = 174) and mature cataract patients (MC, n = 50). Surgeon's ease of visualization (4.92-5.00) and hand-eye coordination score (4.97-5.00) were comparable between the NG- and SOM-groups. Postoperative neck discomfort was lower in both the groups, with a relatively lower discomfort in the NG-group (score: 1.04 vs 1.56). The Spearman rank correlation coefficient (r) between illumination of the operation theatre room and the surgical field revealed a weak negative correlation for most of the patients in the NG-group, and a positive correlation for patients in the SOM-group. No correlation was obtained between brightness of the surgical field and comfort with the surgical field brightness. CONCLUSIONS: Similar ease of visualization was experienced by the surgeons using NG- and SOM-system. Neck discomfort postsurgery was numerically lower in the NG-group, although not significant. Additionally, the NG-system permitted the safe performance of phacoemulsification using a lower surgical field illumination.


Assuntos
Catarata , Facoemulsificação , Cirurgiões , Humanos , Imageamento Tridimensional , Microcirurgia , Estudos Prospectivos , Método Simples-Cego
4.
J Cataract Refract Surg ; 50(1): 30-36, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37732726

RESUMO

PURPOSE: To assess the effect of change in ocular spherical aberration (SA) with adaptive optics on visual acuity (VA) at different defocus after implantation of extended depth-of-focus (EDOF) and enhanced monofocal intraocular lenses (IOLs). SETTINGS: Narayana Nethralaya Eye Hospital, Bangalore, India. DESIGN: Prospective, longitudinal, observational. METHODS: 80 eyes (40 patients) that had cataract surgery were included in the study. 40 eyes were implanted with Eyhance EDOF IOLs and the remaining with Vivity EDOF IOLs. Baseline ocular aberrations were measured with a visual adaptive optics aberrometer, then the optimal SA was determined by increasing it in steps of -0.01 µm up to -0.1 µm until the maximum improvement in near distance VA was observed for a given eye. Then the defocus curve for each eye was measured after modifying the ocular SA by magnitude equal to optimal SA. RESULTS: Most of the eyes accepted a negative induced SA of -0.05 µm (Eyhance group: 67.6%; Vivity group, 45.2%). In the Eyhance group (dominant eyes), VA improved at -2 diopters (D) ( P < .02) only and degraded at 0 D, +0.5 D, and +1 D defocus ( P < .05). In the Vivity group, the VA remained unchanged at all defocus ( P > .05). In the Eyhance group (nondominant eyes), VA improved at -3.5 D defocus only and degraded at +1.5 D and +2 D defocus ( P < .05). In the Vivity group, VA improved at -2.5 D defocus ( P < .05) only. CONCLUSIONS: A negative induced SA of -0.05 µm in implanted eyes was optimal for a slight improvement in distance-corrected near and intermediate VA without any significant decrease in baseline distance-corrected VA.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Percepção de Profundidade , Índia , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Refração Ocular , Acuidade Visual , Estudos Longitudinais
5.
Indian J Ophthalmol ; 71(9): 3224-3228, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37602612

RESUMO

Purpose: To evaluate the accuracy of intraocular lens (IOL) power prediction of the formulas available on the American Society of Cataract and Refractive Surgery (ASCRS) post-refractive calculator in eyes with prior radial keratotomy (RK) for myopia. Methods: This retrospective study included 25 eyes of 18 patients whose status was post-RK for treatment of myopia, which had undergone cataract extraction with IOL implantation. Prediction error was calculated as the difference between implanted IOL power and predicted power by various formulae available on ASCRS post-refractive calculator. The formulas compared were Humphrey Atlas method, IOLMaster/Lenstar method, Barrett True-K no-history formula, ASCRS Average power, and ASCRS Maximum power on ASCRS post-refractive calculator. Results: Median absolute errors were the least for Barrett True-K and ASCRS Maximum power, that is, 0.56 (0.25, 1.04) and 0.56 (0.25, 1.06) D, respectively, and that of Atlas method was 1.60 (0.85, 2.28) D. Median arithmetic errors were positive for Atlas, Barrett True-K, ASCRS Average (0.86 [-0.17, 1.61], 0.14 [-0.22 to 0.54], and 0.23 [-0.054, 0.76] D, respectively) and negative for IOLMaster/Lenstar method and ASCRS Maximum power (-0.02 [-0.46 to 0.38] and - 0.48 [-1.06 to - 0.22] D, respectively). Multiple comparison analysis of Friedman's test revealed that Atlas formula was significantly different from IOLMaster/Lenstar, Barrett True-K, and ASCRS Maximum power; ASCRS Maximum power was significantly different from all others (P < 0.00001). Conclusion: In post-RK eyes, Barrett True-K no-history formula and ASCRS Maximum power given by the ASCRS calculator were more accurate than other available formulas, with ASCRS Maximum leading to more myopic outcomes when compared to others.


Assuntos
Catarata , Ceratotomia Radial , Lentes Intraoculares , Miopia , Procedimentos Cirúrgicos Refrativos , Humanos , Estudos Retrospectivos , Miopia/diagnóstico , Miopia/cirurgia
6.
Indian J Ophthalmol ; 71(5): 1855-1861, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37203044

RESUMO

Purpose: To compare post-operative pain perception using bandage contact lens (BCL) stored at 2-8°C (Cold BCL, CL-BCL) or room temperature (23 - 25°C, RT-BCL) after photorefractive keratectomy (PRK) or corneal collagen-crosslinking (CXL) and determine status of nociception associated factors. Methods: In this prospective interventional study, 56 patients undergoing PRK for refractive correction and 100 keratoconus (KC) undergoing CXL were recruited following approval from the institutional ethics committee with informed consent. Patients undergoing bilateral PRK received RT-BCL on one eye and CL-BCL on the other. Pain was graded by Wong-Baker scoring on the first post-operative day (PoD1). Expression of transient receptor potential channels (TRPV1, TRPA1, TRPM8), calcitonin gene-related peptide (CGRP) and IL-6 was measured in cellular content from used BCLs collected on PoD1. Equal number of KC patients received RT-BCL or CL-BCL post-CXL. Pain was graded by Wong-Baker scoring on PoD1. Results: Pain scores on PoD1 were significantly (P < 0.0001) reduced in subjects receiving CL-BCL (Mean ± SD: 2.6 ± 2.1) compared to RT-BCL (6.0 ± 2.4) post-PRK. 80.4% of subjects reported reduced pain scores with CL-BCL. 19.6% reported no change or increased pain scores with CL-BCL. TRPM8 expression was significantly (P < 0.05) increased in BCL of subjects reporting reduced pain with CL-BCL compared to those who did not. Pain scores on PoD1 were significantly (P < 0.0001) reduced in subjects receiving CL-BCL (3.2 ± 2.1) compared to RT-BCL (7.2 ± 1.8) post-CXL. Conclusion: The simple approach of using a cold BCL post-operatively substantially reduced pain perception and could overcome post-operative pain-related limited acceptance of PRK/CXL.


Assuntos
Lentes de Contato , Ceratocone , Ceratectomia Fotorrefrativa , Humanos , Acuidade Visual , Estudos Prospectivos , Ceratocone/diagnóstico , Ceratocone/cirurgia , Bandagens , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/prevenção & controle , Percepção da Dor , Colágeno/farmacologia , Colágeno/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico
7.
Indian J Ophthalmol ; 71(5): 1882-1888, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37203049

RESUMO

Purpose: The purpose of this study was to identify and analyze the clinical and ocular surface risk factors influencing the progression of keratoconus (KC) using an artificial intelligence (AI) model. Methods: This was a prospective analysis in which 450 KC patients were included. We used the random forest (RF) classifier model from our previous study (which evaluated longitudinal changes in tomographic parameters to predict "progression" and "no progression") to classify these patients. Clinical and ocular surface risk factors were determined through a questionnaire, which included presence of eye rubbing, duration of indoor activity, usage of lubricants and immunomodulator topical medications, duration of computer use, hormonal disturbances, use of hand sanitizers, immunoglobulin E (IgE), and vitamins D and B12 from blood investigations. An AI model was then built to assess whether these risk factors were linked to the future progression versus no progression of KC. The area under the curve (AUC) and other metrics were evaluated. Results: The tomographic AI model classified 322 eyes as progression and 128 eyes as no progression. Also, 76% of the cases that were classified as progression (from tomographic changes) were correctly predicted as progression and 67% of cases that were classified as no progression were predicted as no progression based on clinical risk factors at the first visit. IgE had the highest information gain, followed by presence of systemic allergies, vitamin D, and eye rubbing. The clinical risk factors AI model achieved an AUC of 0.812. Conclusion: This study demonstrated the importance of using AI for risk stratification and profiling of patients based on clinical risk factors, which could impact the progression in KC eyes and help manage them better.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Córnea , Topografia da Córnea/métodos , Inteligência Artificial , Fatores de Risco , Imunoglobulina E , Demografia
8.
J Cutan Aesthet Surg ; 15(3): 226-229, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36561403

RESUMO

Background: Glomus because of their small size in fingers presents difficulty in clear visualization in the operation theater and requires magnifying techniques. Because of the dearth of infrastructure in many hospitals, the excision of these is done with either no or inadequate magnification. Magnetic resonance imaging (MRI) has become the gold standard investigation as glomus tumors can be visualized on radiology very clearly. The reason for recurrence given in the literature is access to tumors by the type of surgical approach for clear visualization, but high magnification being the most important, as the size of glomus is very small has no or limited mention in the literature. Being in a tertiary care hospital, we have analyzed the role of high magnification in the excision of glomus and its impact on recurrence as the end outcome. Aim: To understand the role of intraoperative high magnification using operative microscope and its advantages in the surgical clearance of glomus tumor of fingers. Settings and Design: Retrospective record review. Materials and Methods: Thirteen cases of glomus tumor in the phalanges over a period of 7 years were operated under operative microscope with a magnification ranging from 10× to 12.5×; data and mean follow-up to 5.5 years have been analyzed. Results: Age ranged from 24 to 72 years; all the glomus tumors were in the distal phalanx. Three cases had bony erosion on MRI scan. We had an equal distribution of three cases each in the thumb, ring, and middle finger. Conclusions: (1) High magnification with operative microscope is essential during the excision of glomus tumor especially in the distal phalanx in order to prevent recurrence; (2) advantages of high magnification are clear delineation with complete tumor excision, with meticulous repair of nail bed.

9.
Clin Ophthalmol ; 16: 4215-4225, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36561374

RESUMO

Purpose: To assess real-world clinical outcomes and safety of the Clareon® intraocular lens (IOL) and AutonoMe® automated preloaded delivery system in an Indian population. Patients and methods: This was a prospective, single-arm, multicenter, 12-month clinical study in patients aged ≥20 years with unilateral or bilateral cataracts. Surgery was performed by phacoemulsification followed by implantation of the Clareon monofocal IOL (CNA0T0). Monocular best-corrected distance visual acuity (BCDVA) and uncorrected distance visual acuity (UCDVA) were assessed at 1 week and 1, 6, and 12 months after implantation. Posterior capsular opacification (PCO), surface haze, and glistenings were evaluated at all visits. Surgeons' satisfaction with automated injector system was also evaluated using a questionnaire. Safety was assessed by monitoring adverse events (AEs). Results: A total of 151 eyes received the CNA0T0 IOL. Mean ± SD monocular BCDVA improved from 0.53±0.44 logMAR preoperatively to 0.00±0.08 logMAR at week 1 and -0.03±0.08 logMAR at 12 months after implantation. At 12 months, 137/137 (100%) of eyes achieved BCDVA of 0.3 logMAR or better. Mean ± SD monocular UCDVA was 0.78±0.40 logMAR preoperatively, 0.11±0.15 logMAR at week 1, and 0.08±0.13 logMAR at 12 months after implantation. At 12 months, 132/137 (96%) eyes achieved UCDVA of 0.3 logMAR or better. Serious intraoperative AEs were posterior capsule rupture (n=1) and ciliary zonular dehiscence (n=1). Surgeons reported that the automated preloaded device was more intuitive compared with other push- or screw-style preloaded injector systems. None of the eyes in this study presented surface haze; all were graded as 0 glistenings at all visits. No clinically significant PCO or neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomies were reported. Conclusion: The hydrophobic IOL preloaded in an automated injector system provided good visual and refractive outcomes, as well as no surface haze and grade 0 glistenings. None of the patients required Nd:YAG capsulotomy.

10.
Indian J Ophthalmol ; 69(8): 2027-2032, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34304171

RESUMO

Purpose: To determine the causes of severe visual impairment and blindness in children in schools for the blind in the city of Bangalore, Karnataka and to determine the error of inclusion and exclusion from these schools. Methods: This was a cross-sectional study. Children in four schools for the blind were subjected to a detailed ophthalmic evaluation. The World Health Organization Program for Prevention of Blindness low-vision form was used to collect data. To know the educational background of children with visual disability of 40% or more (best-corrected visual acuity of ≤6/24 in the better eye), not in schools for the blind, we collected data by telephonic conversation after procuring their phone numbers from our low-vision clinic. Results: One-hundred-seventy-eight children were examined. The major site of anomaly causing blindness in 31% of children was optic nerve, followed by retina (24%), cornea (23%), and whole globe (22%). Avoidable blindness was 35.42%. Thirteen percent of the children with no visual disability were incorrectly enrolled in blind schools. We were able to contact 92 children with a visual disability of ≥40%. Seventy-eight children (84.78%) attended regular schools; these schools were bereft of a specially trained teacher to look after the needs of the blind. Conclusion: Avoidable blindness is still a cause for concern. Children should undergo eye-examination before being enrolled in schools for the blind to avoid errors of inclusion. Though integrated education for children with vision disability is a good approach, it requires teachers trained in teaching skills particular to blindness. Education for the visually impaired in India needs a major revision.


Assuntos
Baixa Visão , Pessoas com Deficiência Visual , Cegueira/epidemiologia , Cegueira/etiologia , Cegueira/prevenção & controle , Criança , Estudos Transversais , Humanos , Índia/epidemiologia , Instituições Acadêmicas , Baixa Visão/epidemiologia
11.
J Cataract Refract Surg ; 47(5): 585-592, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33252565

RESUMO

PURPOSE: To compare the repeatability of ocular biometry measured with the LENSTAR LS 900, IOLMaster 700, and Anterion and its impact on predicted intraocular lens (IOL) power. SETTING: Tertiary eye-care facility in South India. DESIGN: Prospective, observational, cross-sectional study. METHODS: Eyes diagnosed with cataract had 3 consecutive scans on each biometers. The repeatability was assessed using the within-subject standard deviation (Sw), test-retest repeatability, and coefficient of variation (CoV). The agreement was evaluated with the intraclass correlation (ICC). The IOL power was calculated with the Barrett Universal II formula. RESULTS: The study comprised 127 eyes of 76 patients. The repeatability of all parameters for a given device were excellent (ICC >0.9, low CoV and Sw). The agreement of the parameters between the biometers was very good (range from 0.93 to 0.99). The predicted IOL power differed statistically between the devices (P < .05), but the difference was clinically insignificant between the 3 biometers (ICC >0.99 for repeat calculation of IOL power). CONCLUSIONS: All the biometers included in the study had good to excellent repeatability of biometry parameters. The agreement of the predicted IOL power was excellent between the 3 optical biometers.


Assuntos
Lentes Intraoculares , Comprimento Axial do Olho , Biometria , Estudos Transversais , Humanos , Índia , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
Clin Ophthalmol ; 15: 213-225, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33519183

RESUMO

PURPOSE: To evaluate the effectiveness and safety of a presbyopia-correcting trifocal intraocular lens (IOL), AcrySof® IQ PanOptix® (TFNT00), in an Indian population. PATIENTS AND METHODS: This prospective, multicenter, observational, single-arm, post-marketing study included 67 patients undergoing cataract surgery with bilateral implantation of TFNT00 across five Indian sites. Postoperative outcomes were assessed at 3 months after second eye surgery. Effectiveness outcomes included: mean binocular and monocular visual acuity (VA) at distance (4 m), intermediate (60 cm), and near (40 cm); binocular defocus curve; manifest refraction; and subjective symptom questionnaire evaluation. Safety outcomes included the rate of ocular adverse events and mesopic contrast sensitivity. RESULTS: Mean binocular and monocular distance-corrected and uncorrected VAs of 0.1 logMAR or better (approximately 20/25 Snellen) were achieved at distance, intermediate, and near. Overall, ≥70% of patients achieved binocular 0.1 logMAR vision or better across all distances. TFNT00 maintained a mean VA of 0.1 logMAR or better at the defocus range of +0.5 diopters (D) to -2.5 D (200 cm to 40 cm). The subjective symptom questionnaire-assessed frequency of halo visual disturbances was low at Month 3; halos were reported "none of the time" to "only some of the time" in 86.6% of patients. The large majority of patients (98.5%) were "satisfied" or "very satisfied" with their near, intermediate, and distance vision at Month 3, and ≥94.0% of patients reported spectacle independence for tasks at all distances. The adverse event rate was low; no patients discontinued due to an adverse event. CONCLUSION: TFNT00 provided a continuous range of vision of 20/25 or better for distance to near and performed effectively at an intermediate functional distance of 60 cm, resulting in high levels of spectacle independence and patient satisfaction. TFNT00 demonstrated a good safety profile and a low post-operative frequency of halo visual disturbances.

13.
Indian J Ophthalmol ; 68(12): 2663-2669, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33229641

RESUMO

Refractive surgery has evolved from being a therapeutic correction of high refractive errors to a cosmetic correction. The expectations associated with such a surgery are enormous and one has to anticipate all possible complications and side-effects that come with the procedure and prepare accordingly. The most common amongst these is post-refractive surgery dry eye of which Meibomian gland dysfunction is a commonly associated cause. We present an understanding of various diagnostic imaging modalities that can be used for evaluating meibomian glands which can also serve as a visual aid for patient understanding. We also describe various common conditions which can silently cause changes in the gland architecture and function which are to be considered and evaluated for.


Assuntos
Síndromes do Olho Seco , Doenças Palpebrais , Disfunção da Glândula Tarsal , Cirurgiões , Síndromes do Olho Seco/diagnóstico , Humanos , Glândulas Tarsais/diagnóstico por imagem , Lágrimas
14.
J Burn Care Res ; 41(6): 1304-1305, 2020 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-32735668

RESUMO

Electrical injuries are among the most devastating of burn injuries. High-voltage electrical injuries result in extensive deep tissue damage and are associated with multiple complications, long-term morbidity, and a high mortality rate. We describe the case of a 16-year-old male cable operator who suffered high-voltage electric injury of left upper limb and anterior abdominal wall. Despite the exit wound causing transection of the ileum, the patient did not have any contamination of the peritoneal cavity as both ends of the bowel were sealed off due to electro-thermal energy. His management included multiple operative procedures, including intestinal resection and anastomosis, debridement, abdominal wall flap-based reconstruction, fasciotomies, split skin grafting, and left hand above elbow amputation.


Assuntos
Queimaduras por Corrente Elétrica/terapia , Intestino Delgado/lesões , Intestino Delgado/cirurgia , Adolescente , Amputação Cirúrgica , Traumatismos do Braço/cirurgia , Desbridamento , Fasciotomia , Humanos , Masculino , Procedimentos de Cirurgia Plástica , Transplante de Pele
15.
Indian J Ophthalmol ; 68(12): 2831-2834, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33229658

RESUMO

Recent advances in the diagnosis and treatment of ectatic corneal disease have mandated a more modern staging system. The new Belin ABCD keratoconus staging system incorporates anterior and posterior curvature centered on the thinnest point of the cornea, thinnest pachymetry values and distance visual acuity in grades from 0-4. By including posterior curvature and thickness measurements based on the thinnest point, as opposed to apical, the new staging system better reflects anatomical changes seen in keratoconus and other ectatic diseases.


Assuntos
Ceratocone , Córnea , Paquimetria Corneana , Topografia da Córnea , Dilatação Patológica , Humanos , Ceratocone/diagnóstico , Acuidade Visual
16.
Indian J Ophthalmol ; 68(12): 2899-2902, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33229666

RESUMO

PURPOSE: To evaluate the relation of the tear film on the quality of vision comparing parameters in normal patients to those having dry eye disease. METHODS: 50 normal and 50 eyes with dry eye disease (DED) were included in the study. Patients were screened for dry eye with Schirmer's test, tear break up time, ocular surface staining, and assessment of meibomian gland disease. Their quality of vision was assessed using the Optical quality analysis system (OQAS). The results of dry eye evaluation were correlated with the parameters on the OQAS especially the mean objective scatter index (OSI). RESULTS: Patients with dry eye and unstable tear film were found to have a significantly worse quality of vision and optical scatter (P < 0.05). They were also noted to have fluctuation of vision between blinks. CONCLUSION: Tear film optics can have an important bearing on the quality of vision and quality of life. A detailed assessment preoperatively will help improve surgical outcomes and patient satisfaction.


Assuntos
Síndromes do Olho Seco , Lacerações , Piscadela , Síndromes do Olho Seco/diagnóstico , Humanos , Qualidade de Vida , Lágrimas
17.
Indian J Ophthalmol ; 68(12): 3072-3074, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33229711

RESUMO

Ocular trauma can range from trivial to significant, with varying implications on the visual acuity and prognosis. A 32-year-old woman presented with complaints of blurring of vision following blunt ocular trauma with a previous history of having undergone implantable phakic contact lens (IPCL V2.0) implantation 2 years back. The corrected distance visual acuity (CDVA) was 20/20 in the right eye and 20/30 in the left eye. Slit-lamp examination revealed a prolapse of inferonasal IPCL footplate into the anterior chamber with pupillary entrapment. No corneal endothelial touch was noted. Immediate repositioning of the IPCL was performed and the patient regained a CDVA of 20/20 in the left eye, postoperatively. Traumatic dislocation of IPCL is a rare occurrence, which can be successfully managed by prompt surgery, thus avoiding further complications like corneal endothelial decompensation.


Assuntos
Lentes de Contato , Traumatismos Oculares , Lentes Intraoculares , Lentes Intraoculares Fácicas , Adulto , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/etiologia , Traumatismos Oculares/cirurgia , Feminino , Humanos , Implante de Lente Intraocular , Acuidade Visual
18.
Indian J Ophthalmol ; 68(12): 2880-2887, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33229663

RESUMO

Phakic intraocular lenses (IOL) are a boon for patients who want spectacle independence but are unable to get refractive correction through laser platforms due to high refractive error or certain corneal contraindications. Phakic IOL's (PIOL) have their own set of complications and challenges, the most important being getting the sizing right. This paper attempts to solve the problem of accurate sizing of PIOL's. Parameters needed for calculating the ideal size of PIOL's have been studied in a step by step manner using all possible tools depending upon the availability and preference of the surgeon. The pros and cons of using a particular tool for measurements have been highlighted along with illustrative case examples to help surgeons who are starting PIOL implantation surgery.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Fácicas , Erros de Refração , Córnea , Óculos , Humanos
19.
J Biophotonics ; 13(9): e202000107, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32392370

RESUMO

The purpose of this study was to evaluate early vascular and tomographic changes in the retina of diabetic patients using artificial intelligence (AI). The study included 74 age-matched normal eyes, 171 diabetic eyes without retinopathy (DWR) eyes and 69 mild non-proliferative diabetic retinopathy (NPDR) eyes. All patients underwent optical coherence tomography angiography (OCTA) imaging. Tomographic features (thickness and volume) were derived from the OCTA B-scans. These features were used in AI models. Both OCT and OCTA features showed significant differences between the groups (P < .05). However, the OCTA features indicated early retinal changes in DWR eyes better than OCT (P < .05). In the AI model using both OCT and OCTA features simultaneously, the best area under the curve of 0.91 ± 0.02 was obtained (P < .05). Thus, the combined use of AI, OCT and OCTA significantly improved the early diagnosis of diabetic changes in the retina.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Inteligência Artificial , Retinopatia Diabética/diagnóstico por imagem , Angiofluoresceinografia , Humanos , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica
20.
J Glaucoma ; 29(11): 1006-1016, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32947358

RESUMO

PURPOSE: To quantify aerosol and droplets generated during noncontact tonometry (NCT) and assess the spread distance of the same. METHODOLOGY: This was an experimental study on healthy human volunteers (n=8 eyes). In an experimental setup, NCT was performed on eyes (n=8) of human volunteers under normal settings, with a single and 2 drops of lubricant. High-speed shadowgraphy, frontal lighting technique, and fluorescein analysis were used to detect the possible generation of any droplets and aerosols. Mathematical computation of the spread of the droplets was then performed. RESULTS: In a natural setting, there was no droplet or aerosol production. Minimal splatter along with droplet ejection was observed when 1 drop of lubricant was used before NCT. When 2 drops of lubricant were instilled, a significant amount of fluid ejection in the form of a sheet that broke up into multiple droplets was observed. Some of these droplets traversed back to the tonometer. Droplets ranging from 100 to 500 µm in diameter were measured. CONCLUSIONS: There was no droplet generation during NCT performed in a natural setting. However, NCT should be avoided in conditions with high-tear volume (natural or artificial) as it would lead to droplet spread and tactile contamination.


Assuntos
Aerossóis/química , Betacoronavirus , Infecções por Coronavirus/transmissão , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Pressão Intraocular/fisiologia , Pneumonia Viral/transmissão , Lágrimas/química , Tonometria Ocular/instrumentação , Adolescente , Adulto , COVID-19 , Monitoramento Ambiental , Feminino , Fluoresceína/administração & dosagem , Corantes Fluorescentes/administração & dosagem , Humanos , Lubrificantes Oftálmicos/administração & dosagem , Masculino , Imagem Óptica , Pandemias , SARS-CoV-2 , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA