Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 388(20): 1833-1842, 2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-36876753

RESUMO

BACKGROUND: Severe tricuspid regurgitation is a debilitating condition that is associated with substantial morbidity and often with poor quality of life. Decreasing tricuspid regurgitation may reduce symptoms and improve clinical outcomes in patients with this disease. METHODS: We conducted a prospective randomized trial of percutaneous tricuspid transcatheter edge-to-edge repair (TEER) for severe tricuspid regurgitation. Patients with symptomatic severe tricuspid regurgitation were enrolled at 65 centers in the United States, Canada, and Europe and were randomly assigned in a 1:1 ratio to receive either TEER or medical therapy (control). The primary end point was a hierarchical composite that included death from any cause or tricuspid-valve surgery; hospitalization for heart failure; and an improvement in quality of life as measured with the Kansas City Cardiomyopathy Questionnaire (KCCQ), with an improvement defined as an increase of at least 15 points in the KCCQ score (range, 0 to 100, with higher scores indicating better quality of life) at the 1-year follow-up. The severity of tricuspid regurgitation and safety were also assessed. RESULTS: A total of 350 patients were enrolled; 175 were assigned to each group. The mean age of the patients was 78 years, and 54.9% were women. The results for the primary end point favored the TEER group (win ratio, 1.48; 95% confidence interval, 1.06 to 2.13; P = 0.02). The incidence of death or tricuspid-valve surgery and the rate of hospitalization for heart failure did not appear to differ between the groups. The KCCQ quality-of-life score changed by a mean (±SD) of 12.3±1.8 points in the TEER group, as compared with 0.6±1.8 points in the control group (P<0.001). At 30 days, 87.0% of the patients in the TEER group and 4.8% of those in the control group had tricuspid regurgitation of no greater than moderate severity (P<0.001). TEER was found to be safe; 98.3% of the patients who underwent the procedure were free from major adverse events at 30 days. CONCLUSIONS: Tricuspid TEER was safe for patients with severe tricuspid regurgitation, reduced the severity of tricuspid regurgitation, and was associated with an improvement in quality of life. (Funded by Abbott; TRILUMINATE Pivotal ClinicalTrials.gov number, NCT03904147.).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Feminino , Humanos , Masculino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Insuficiência da Valva Tricúspide/cirurgia
2.
Dig Dis Sci ; 69(2): 562-569, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38135813

RESUMO

BACKGROUND: Long-COVID is a condition post SARS-CoV-2 infection with persistent or recurring symptoms affecting multiple organs, and may involve viral persistence, changes to the microbiome, coagulopathies, and alterations to neuro-immune interactions. These factors can disrupt the Gut-Brain Axis, which is a complex system involving bidirectional communication between the central nervous system and the gastrointestinal (GI) system. As a result of these disruptions, individuals with long-COVID may develop post-infectious functional GI disorders, which can cause a range of symptoms affecting the digestive system. AIM: To understand frequency of GI manifestations of Long-COVID and to determine association with sleep or neurological symptoms in a predominantly minority population. METHODS: We included patients with positive SARS-CoV-2 PCR (n = 747) who were hospitalized from Feb. 2020 to May 2021 at Howard University Hospital and followed between 6 and 12 months from discharge. GI, sleep, and neurological symptoms (via the Montreal Cognitive Assessment (MoCA) scoring system) were assessed using a standardized questionnaire. Linear regression analysis, χ2 and Fisher's exact test were utilized to determine the statistical significance of correlations of GI/Neuro/COVID. RESULTS: The mean age of patients was 58, with 51.6% females and a predominant African American ethnicity (73.6%, n = 550). A total of 108 patients died during their initial hospital stay, with the remaining 639 patients followed-up. Three hundred fifty (350) patients responded to the questionnaire (57 patients died during the follow-up period). Overall, 39 (13.3%) patients reported GI-related symptoms, out of which 19 (6.4%) had persistent symptoms and 20 (6.8%) developed new onset GI symptoms. Nausea and vomiting were the most common 24/39 (61.5%), followed by abdominal pain 7/39 (18%), diarrhea 5/39 (12.8%), and others 3/39 (7.6%). Patients who presented with vomiting during acute SARS-CoV-2 infection were more likely to have Long-COVID GI manifestations (P = 0.023). Use of ACE inhibitors, abnormal lymphocyte count and elevated ferritin are other variables that showed significant associations with Long-COVID GI manifestations (P = 0.03, 0.006 and 0.03, respectively). During follow-up, a total of 28 (9.5%) patients reported difficulty with sleep and 79 (27%) patients had abnormal MoCA assessment. With further analysis, there was a trend between presentation of GI symptoms on admission with abnormal MoCA assessment, and an association between abnormal LFTs and history of liver disease during hospitalization with subsequent sleep problems. Baseline characteristics, clinical comorbidities, other laboratory values, hospital length of stay, mechanical ventilation, medications during hospitalization, re-admission and Flu or COVID-19 vaccination have not shown any association with Long-COVID GI symptoms in our cohort. CONCLUSION: Dyspeptic symptoms were common GI manifestations in the acute and post COVID periods. GI symptoms, abnormal LFTs and a history of liver disease during the acute infectious phase associates with abnormal MoCA and sleep problems during follow-up. Further large population studies are needed to determine if COVID-19 leads to a GI symptoms-associated Long-COVID phenotypes and other symptoms through the Gut-Brain-Axis.


Assuntos
COVID-19 , Gastroenteropatias , Hepatopatias , Transtornos do Sono-Vigília , Feminino , Humanos , Masculino , COVID-19/complicações , COVID-19/diagnóstico , COVID-19/epidemiologia , SARS-CoV-2 , Seguimentos , Síndrome de COVID-19 Pós-Aguda , Estudos Prospectivos , Vacinas contra COVID-19 , Gastroenteropatias/diagnóstico , Gastroenteropatias/epidemiologia , Gastroenteropatias/etiologia , Hepatopatias/complicações , Vômito , Transtornos do Sono-Vigília/etiologia , Transtornos do Sono-Vigília/complicações
3.
Eur J Orthop Surg Traumatol ; 34(1): 75-89, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37656278

RESUMO

PURPOSE: A locking plate (LP) or non-locking plate (NLP) can be used for distal fibula fracture fixation. However, the advantages of LP over NLP in patients with distal fibula fractures are not clear. In terms of indications, the role of the two plates probably differs; however, to draw comparative conclusions, we conceptualized this systematic review and meta-analysis of studies that directly compared the two plates, wherein both groups' indications and baseline parameters were similar. METHODS: An electronic literature search was performed using PubMed/Medline, Embase, Scopus, and Cochrane Library databases for studies comparing the LP versus NLP fixation for the lateral malleolus fracture. A total of 18 studies were included in qualitative and quantitative analysis. A subgroup analysis was performed for patients aged < 55 years and patients aged > 55 years. The statistical analysis was performed by Review Manager Software version 5.4.1. RESULTS: A meta-analysis of 4243 fractures was performed across 18 studies. The rate of fracture union and overall complication rates did not differ between the two fixation groups with an OR of 0.71 (95% CI 0.26, 1.96, p = 0.51 and 1.11 (95% CI 0.84, 1.47, p = 0.47, respectively. There is no difference in the reoperation rate due to minor or major complications between the two groups. There was no difference in functional outcome (MD -0.85, with 95% CI -5.63, 3.93, p = 0.73), but NLP has a shorter surgical duration (MD 3.0, with 95% CI 0.26, 5.75, p = 0.03). A leave-one-out sensitivity analysis performed for overall complications affected the final outcome of the meta-analysis. CONCLUSION: This meta-analysis demonstrates no clear benefit in selecting LP over NLP for the fixation of lateral malleolus fractures.


Assuntos
Fraturas do Tornozelo , Fraturas da Fíbula , Humanos , Fraturas do Tornozelo/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Reoperação , Placas Ósseas , Fíbula/cirurgia , Resultado do Tratamento
4.
Europace ; 25(4): 1415-1422, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36881781

RESUMO

AIMS: To determine outcomes in atrial fibrillation patients undergoing percutaneous left atrial appendage occlusion (LAAO) based on the underlying stroke risk (defined by the CHA2DS2-VASc score). METHODS AND RESULTS: Data were extracted from the National Inpatient Sample for calendar years 2016-20. Left atrial appendage occlusion implantations were identified on the basis of the International Classification of Diseases, 10th Revision, Clinical Modification code of 02L73DK. The study sample was stratified on the basis of the CHA2DS2-VASc score into three groups (scores of 3, 4, and ≥5). The outcomes assessed in our study included complications and resource utilization. A total of 73 795 LAAO device implantations were studied. Approximately 63% of LAAO device implantations occurred in patients with CHA2DS2-VASc scores of 4 and ≥5. The crude prevalence of pericardial effusion requiring intervention was higher with increased CHA2DS2-VASc score (1.4% in patients with a score of ≥5 vs. 1.1% in patients with a score of 4 vs. 0.8% in patients with a score of 3, P < 0.01). In the multivariable model adjusted for potential confounders, CHA2DS2-VASc scores of 4 and ≥5 were found to be independently associated with overall complications [adjusted odds ratio (aOR) 1.26, 95% confidence interval (CI) 1.18-1.35, and aOR 1.88, 95% CI 1.73-2.04, respectively] and prolonged length of stay (aOR 1.18, 95% CI 1.11-1.25, and aOR 1.54, 95% CI 1.44-1.66, respectively). CONCLUSION: A higher CHA2DS2-VASc score was associated with an increased risk of peri-procedural complications and resource utilization after LAAO. These findings highlight the importance of patient selection for the LAAO procedure and need validation in future studies.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
Europace ; 24(9): 1451-1459, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35613020

RESUMO

AIMS: To determine outcomes in atrial fibrillation (AF) patients undergoing percutaneous left atrial appendage occlusion (LAAO) with concomitant heart failure with preserved ejection fraction (HFpEF) and heart failure with reduced ejection fraction (HFrEF). METHODS AND RESULTS: Data were extracted from National Inpatient Sample for calendar years 2015-2019. LAAO device implantations were identified on the basis of ICD-10-CM code of 02L73DK. The outcomes assessed in our study included complications, in-patient mortality, and resource utilization. A total of 62 980 LAAO device implantations were studied. HFpEF (14.4%, n = 9040) and HFrEF (11.2%, n = 7100) were associated with a higher prevalence of major complications and in-patient mortality in crude analysis. In the multivariate model adjusted for potential confounders, HFpEF and HFrEF were not associated with major complications [adjusted odds ratio (aOR) 1.04, 95% confidence interval (CI) 0.93-1.16 and aOR 1.07, 95% CI 0.95-1.21] or in-patient mortality (aOR 1.48, 95% CI 0.85-2.55 and aOR 1.26, 95% CI 0.67-2.38). HFpEF and HFrEF were associated with prolonged length of stay (LOS) > 1 day (aOR 1.41, 95% CI 1.31-1.53 and aOR 1.66, 95% CI 1.53-1.80) and increased hospitalization costs > median cost 24 752$ (aOR 1.26, 95% CI 1.19-1.34 and aOR 1.21, 95% CI 1.13-1.29). CONCLUSION: The prevalence of HF in AF patients undergoing percutaneous LAAO was approximately 26%. HF was not independently associated with major complications and in-patient mortality but was associated with prolonged LOS and higher hospitalization costs.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Cardíaca , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitais , Humanos , Pacientes Internados , Prognóstico , Volume Sistólico/fisiologia
6.
J Immunol ; 205(10): 2806-2820, 2020 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33055281

RESUMO

Intermediate monocytes (iMo; CD14+CD16+) increase in number in the circulation of patients with unstable coronary artery disease (CAD), and their recruitment to inflamed arteries is implicated in events leading to mortality following MI. Monocyte recruitment to inflamed coronary arteries is initiated by high affinity ß2-integrin (CD11c/CD18) that activates ß1-integrin (VLA-4) to bind endothelial VCAM-1. How integrin binding under shear stress mechanosignals a functional shift in iMo toward an inflammatory phenotype associated with CAD progression is unknown. Whole blood samples from patients treated for symptomatic CAD including non-ST elevation MI, along with healthy age-matched subjects, were collected to assess chemokine and integrin receptor levels on monocytes. Recruitment on inflamed human aortic endothelium or rVCAM-1 under fluid shear stress was assessed using a microfluidic-based artery on a chip (A-Chip). Membrane upregulation of high affinity CD11c correlated with concomitant activation of VLA-4 within focal adhesive contacts was required for arrest and diapedesis across inflamed arterial endothelium to a greater extent in non-ST elevation MI compared with stable CAD patients. The subsequent conversion of CD11c from a high to low affinity state under fluid shear activated phospho-Syk- and ADAM17-mediated proteolytic cleavage of CD16. This marked the conversion of iMo to an inflammatory phenotype associated with nuclear translocation of NF-κB and production of IL-1ß+ We conclude that CD11c functions as a mechanoregulator that activates an inflammatory state preferentially in a majority of iMo from cardiac patients but not healthy patients.


Assuntos
Antígeno CD11c/metabolismo , Doença da Artéria Coronariana/imunologia , Endotélio Vascular/imunologia , Monócitos/imunologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/imunologia , Adulto , Idoso , Regulação Alostérica/imunologia , Aorta/citologia , Estudos de Casos e Controles , Técnicas de Cultura de Células , Linhagem Celular , Membrana Celular/metabolismo , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/citologia , Vasos Coronários/imunologia , Células Endoteliais/citologia , Células Endoteliais/imunologia , Células Endoteliais/metabolismo , Endotélio Vascular/metabolismo , Feminino , Humanos , Integrina alfa4beta1/metabolismo , Dispositivos Lab-On-A-Chip , Masculino , Técnicas Analíticas Microfluídicas/instrumentação , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/sangue , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Intervenção Coronária Percutânea , Proteínas Recombinantes/imunologia , Proteínas Recombinantes/metabolismo , Migração Transendotelial e Transepitelial/imunologia , Molécula 1 de Adesão de Célula Vascular/imunologia , Molécula 1 de Adesão de Célula Vascular/metabolismo
7.
Catheter Cardiovasc Interv ; 97(4): 745-754, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33045138

RESUMO

BACKGROUND: During MitraClip implantation sub-valvular correction of trajectory and/or alignment may increase adverse clip or leaflet events. With systematic adjunctive use of fluoroscopy ("Parallax technique"), we aimed to assess parameters that minimize the need for corrective measures and help increase procedural efficiency. METHODS: We retrospectively analyzed 30 patients without (Fl-) and 39 patients utilizing adjunctive fluoroscopy (Fl+) during MitraClip implantation. After establishing trajectory and supra-valvular alignment, the Parallax technique was utilized. Trajectory and alignment are maintained during advancement. RESULTS: All patients had 3 or 4+ MR. There were no differences in baseline demographics. The average number of clips (Fl- vs Fl+) was 1.72 ± 0.8 vs 1.59 ± 0.5, p = .57. For the first clip, the need for sub-valvular alignment (80% vs. 36%, p = .0001), eversion with retraction back to left atrium (23% vs. 10%, p = .001) and the number of grasps (2.3 ± 1.2 vs 1.4 ± 0.9) was reduced. The time from transseptal puncture to first clip deployment (71 ± 21 vs 44 ± 16 min, p = .01) was reduced. Procedural success was achieved in all but one patient in the Fl- group (p = ns). There were no differences noted for in-hospital or 30-day outcomes. CONCLUSIONS: Systematic use of a simple and easy to implement "Parallax technique" was associated with reduced need for sub-valvular manipulation and was associated with improved procedural times. Further larger scale studies are needed to assess the applicability of the technique.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Fluoroscopia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 96(1): 210-214, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31617308

RESUMO

MitraClip is used for reduction of mitral insufficiency in patients who are not good surgical candidates, but with expanding indications, the use of MitraClip and the number of complications will increase. Here is presented a case of a single leaflet device attachment that worsened the patient's mitral insufficiency, as well as the technique for stabilizing the valve followed by retrieval of the device. A special focus is placed on removing the using a two-snare technique to avoid the need for a surgical cutdown and repair.


Assuntos
Cateterismo Cardíaco , Remoção de Dispositivo , Migração de Corpo Estranho/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Átrios do Coração/diagnóstico por imagem , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 96(3): 699-705, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32259371

RESUMO

The MitraClip procedure is carried out almost exclusively via the transfemoral approach. However, in some patients transfemoral delivery of MitraClip is not technically feasible (e.g., occluded inferior vena cava or tortuous/obstructive iliofemoral venous anatomy). The technical considerations and challenges of the MitraClip procedure are amplified when an alternate route is considered. We describe a successful case of MitraClip performed via the right internal jugular (IJ) approach in a patient with a flail A3 scallop and previous mitral valve repair. We reviewed prior cases in the literature and discuss step-by-step the pertinent clinical and technical considerations for performing this procedure via the transjugular route. In summary, the right IJ access site provides a reasonable alternative to perform the MitraClip procedure in cases where femoral access is contraindicated or prohibitive. A thorough understanding of the technical considerations is crucial in improving procedural success rates.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateterismo Venoso Central , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Veias Jugulares , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Humanos , Veias Jugulares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Recuperação de Função Fisiológica , Reoperação , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 95(3): 414-419, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31638326

RESUMO

A transseptal puncture is critical for "left-sided" structural heart interventions. Procedures such as transcatheter edge-to-edge repair (MitraClip) and left atrial appendage (LAA) closure (Watchman) require precise puncture of the interatrial septum (IAS), and the presence of a prior atrial septal defect (ASD) closure device poses a challenge. We aim to present a successfully completed case of MitraClip and Watchman in the presence of ASD closure device in two different patients. A review of the literature will be reported, and pertinent clinical and technical considerations will be discussed in depth to achieve procedural success. In summary, transseptal puncture for left heart structural interventions is feasible in the presence of a prior ASD/patent foramen ovale closure device. A detailed understanding of the anatomical considerations as well as the use of multimodality imaging to evaluate the IAS will aid in improving procedural success rates.


Assuntos
Fibrilação Atrial/terapia , Cateterismo Cardíaco , Comunicação Interatrial/terapia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Punções , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA