Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(3): 161-177, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-37638967

RESUMO

BACKGROUND AND AIMS: The European Union Medical Device Regulation 2017/745 challenges key stakeholders to follow transparent and rigorous approaches to the clinical evaluation of medical devices. The purpose of this study is a systematic evaluation of published clinical evidence underlying selected high-risk cardiovascular medical devices before and after market access in the European Union (CE-marking) between 2000 and 2021. METHODS: Pre-specified strategies were applied to identify published studies of prospective design evaluating 71 high-risk cardiovascular devices in seven different classes (bioresorbable coronary scaffolds, left atrial appendage occlusion devices, transcatheter aortic valve implantation systems, transcatheter mitral valve repair/replacement systems, surgical aortic and mitral heart valves, leadless pacemakers, subcutaneous implantable cardioverter-defibrillator). The search time span covered 20 years (2000-21). Details of study design, patient population, intervention(s), and primary outcome(s) were summarized and assessed with respect to timing of the corresponding CE-mark approval. RESULTS: At least one prospective clinical trial was identified for 70% (50/71) of the pre-specified devices. Overall, 473 reports of 308 prospectively designed studies (enrolling 97 886 individuals) were deemed eligible, including 81% (251/308) prospective non-randomized clinical trials (66 186 individuals) and 19% (57/308) randomized clinical trials (31 700 individuals). Pre-registration of the study protocol was available in 49% (150/308) studies, and 16% (48/308) had a peer-reviewed publicly available protocol. Device-related adverse events were evaluated in 82% (253/308) of studies. An outcome adjudication process was reported in 39% (120/308) of the studies. Sample size was larger for randomized in comparison to non-randomized trials (median of 304 vs. 100 individuals, P < .001). No randomized clinical trial published before CE-mark approval for any of the devices was identified. Non-randomized clinical trials were predominantly published after the corresponding CE-mark approval of the device under evaluation (89%, 224/251). Sample sizes were smaller for studies published before (median of 31 individuals) than after (median of 135 individuals) CE-mark approval (P < .001). Clinical trials with larger sample sizes (>50 individuals) and those with longer recruitment periods were more likely to be published after CE-mark approval, and were more frequent during the period 2016-21. CONCLUSIONS: The quantity and quality of publicly available data from prospective clinical investigations across selected categories of cardiovascular devices, before and after CE approval during the period 2000-21, were deemed insufficient. The majority of studies was non-randomized, with increased risk of bias, and performed in small populations without provision of power calculations, and none of the reviewed devices had randomized trial results published prior to CE-mark certification.


Assuntos
Sistema Cardiovascular , Substituição da Valva Aórtica Transcateter , Humanos , Coração , Próteses e Implantes , União Europeia
2.
Eur Heart J ; 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39217617

RESUMO

BACKGROUND AND AIMS: Neoatherosclerosis is a leading cause of late (>1 year) stent failure following drug-eluting stent implantation. The role of biodegradable (BP) versus durable polymer (DP) drug-eluting stents on long-term occurrence of neoatherosclerosis remains unclear. Superiority of biodegradable against durable polymer current generation thin-strut everolimus-eluting stent (EES) was tested by assessing the frequency of neoatherosclerosis 3 years after primary percutaneous coronary intervention (pPCI) among patients with ST-segment elevation myocardial infarction (STEMI). METHODS: The randomized controlled, multicentre (Japan and Switzerland) CONNECT trial (NCT03440801) randomly (1:1) assigned 239 STEMI patients to pPCI with BP-EES or DP-EES. The primary endpoint was the frequency of neoatherosclerosis assessed by optical coherence tomography (OCT) at 3 years. Neoatherosclerosis was defined as fibroatheroma or fibrocalcific plaque or macrophage accumulation within the neointima. RESULTS: Among 239 STEMI patients randomized, 236 received pPCI with stent implantation (119 BP-EES; 117 DP-EES). A total of 178 patients (75%; 88 in the BP-EES group and 90 in the DP-EES group) underwent OCT assessment at 3 years. Neoatherosclerosis did not differ between the BP-EES (11.4%) and DP-EES (13.3%; odds ratio 0.83, 95% confidence interval 0.33-2.04, p=0.69). There were no differences in the frequency of fibroatheroma (BP-EES 9.1% vs DP-EES 11.1%, p=0.66) or macrophage accumulation (BP-EES 4.5% vs DP-EES 3.3%, p=0.68), and no fibrocalcific neoatherosclerosis was observed. Rates of target lesion failure did not differ between groups (BP-EES 5.9% vs DP-EES 6.0%, p=0.97). CONCLUSIONS: Use of BP-EES for primary PCI in patients presenting with STEMI was not superior to DP-EES regarding frequency of neoatherosclerosis at 3 years.

3.
Artigo em Inglês | MEDLINE | ID: mdl-39307861

RESUMO

PURPOSE: Transthyretin amyloid cardiomyopathy (ATTR-CM) is a frequent concomitant condition in patients with severe aortic stenosis (AS), yet it often remains undetected. This study aims to comprehensively evaluate artificial intelligence-based models developed based on preprocedural and routinely collected data to detect ATTR-CM in patients with severe AS planned for transcatheter aortic valve implantation (TAVI). METHODS: In this prospective, single-center study, consecutive patients with AS were screened with [99mTc]-3,3-diphosphono-1,2-propanodicarboxylic acid ([99mTc]-DPD) for the presence of ATTR-CM. Clinical, laboratory, electrocardiogram, echocardiography, invasive measurements, 4-dimensional cardiac CT (4D-CCT) strain data, and CT-radiomic features were used for machine learning modeling of ATTR-CM detection and for outcome prediction. Feature selection and classifier algorithms were applied in single- and multi-modality classification scenarios. We split the dataset into training (70%) and testing (30%) samples. Performance was assessed using various metrics across 100 random seeds. RESULTS: Out of 263 patients with severe AS (57% males, age 83 ± 4.6years) enrolled, ATTR-CM was confirmed in 27 (10.3%). The lowest performances for detection of concomitant ATTR-CM were observed in invasive measurements and ECG data with area under the curve (AUC) < 0.68. Individual clinical, laboratory, interventional imaging, and CT-radiomics-based features showed moderate performances (AUC 0.70-0.76, sensitivity 0.79-0.82, specificity 0.63-0.72), echocardiography demonstrated good performance (AUC 0.79, sensitivity 0.80, specificity 0.78), and 4D-CT-strain showed the highest performance (AUC 0.85, sensitivity 0.90, specificity 0.74). The multi-modality model (AUC 0.84, sensitivity 0.87, specificity 0.76) did not outperform the model performance based on 4D-CT-strain only data (p-value > 0.05). The multi-modality model adequately discriminated low and high-risk individuals for all-cause mortality at a mean follow-up of 13 months. CONCLUSION: Artificial intelligence-based models using collected pre-TAVI evaluation data can effectively detect ATTR-CM in patients with severe AS, offering an alternative diagnostic strategy to scintigraphy and myocardial biopsy.

4.
JAMA ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39298146

RESUMO

Importance: Accurate risk stratification of nonischemic dilated cardiomyopathy (NIDCM) remains challenging. Objective: To evaluate the association of cardiac magnetic resonance (CMR) imaging-derived measurements with clinical outcomes in NIDCM. Data Sources: MEDLINE, Embase, Cochrane Library, and Web of Science Core Collection databases were systematically searched for articles from January 2005 to April 2023. Study Selection: Prospective and retrospective nonrandomized diagnostic studies reporting on the association between CMR imaging-derived measurements and adverse clinical outcomes in NIDCM were deemed eligible. Data Extraction and Synthesis: Prespecified items related to patient population, CMR imaging measurements, and clinical outcomes were extracted at the study level by 2 independent reviewers. Random-effects models were fitted using restricted maximum likelihood estimation and the method of Hartung, Knapp, Sidik, and Jonkman. Main Outcomes and Measures: All-cause mortality, cardiovascular mortality, arrhythmic events, heart failure events, and major adverse cardiac events (MACE). Results: A total of 103 studies including 29 687 patients with NIDCM were analyzed. Late gadolinium enhancement (LGE) presence and extent (per 1%) were associated with higher all-cause mortality (hazard ratio [HR], 1.81 [95% CI, 1.60-2.04]; P < .001 and HR, 1.07 [95% CI, 1.02-1.12]; P = .02, respectively), cardiovascular mortality (HR, 2.43 [95% CI, 2.13-2.78]; P < .001 and HR, 1.15 [95% CI, 1.07-1.24]; P = .01), arrhythmic events (HR, 2.69 [95% CI, 2.20-3.30]; P < .001 and HR, 1.07 [95% CI, 1.03-1.12]; P = .004) and heart failure events (HR, 1.98 [95% CI, 1.73-2.27]; P < .001 and HR, 1.06 [95% CI, 1.01-1.10]; P = .02). Left ventricular ejection fraction (LVEF) (per 1%) was not associated with all-cause mortality (HR, 0.99 [95% CI, 0.97-1.02]; P = .47), cardiovascular mortality (HR, 0.97 [95% CI, 0.94-1.00]; P = .05), or arrhythmic outcomes (HR, 0.99 [95% CI, 0.97-1.01]; P = .34). Lower risks for heart failure events (HR, 0.97 [95% CI, 0.95-0.98]; P = .002) and MACE (HR, 0.98 [95% CI, 0.96-0.99]; P < .001) were observed with higher LVEF. Higher native T1 relaxation times (per 10 ms) were associated with arrhythmic events (HR, 1.07 [95% CI, 1.01-1.14]; P = .04) and MACE (HR, 1.06 [95% CI, 1.01-1.11]; P = .03). Global longitudinal strain (GLS) (per 1%) was not associated with heart failure events (HR, 1.06 [95% CI, 0.95-1.18]; P = .15) or MACE (HR, 1.03 [95% CI, 0.94-1.14]; P = .43). Limited data precluded definitive analysis for native T1 relaxation times, GLS, and extracellular volume fraction (ECV) with respect to mortality outcomes. Conclusion: The presence and extent of LGE were associated with various adverse clinical outcomes, whereas LVEF was not significantly associated with mortality and arrhythmic end points in NIDCM. Risk stratification using native T1 relaxation times, extracellular volume fraction, and global longitudinal strain requires further evaluation.

5.
Circulation ; 146(18): 1329-1343, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36036610

RESUMO

BACKGROUND: In some randomized clinical trials, transradial access (TRA) compared with transfemoral access (TFA) was associated with lower mortality in patients with coronary artery disease undergoing invasive management. We analyzed the effects of TRA versus TFA across multicenter randomized clinical trials and whether these associations are modified by patient or procedural characteristics. METHODS: We performed an individual patient data meta-analysis of multicenter randomized clinical trials comparing TRA with TFA among patients undergoing coronary angiography with or without percutaneous coronary intervention. The primary outcome was all-cause mortality and the co-primary outcome was major bleeding at 30 days. The primary analysis was conducted by 1-stage mixed-effects models on the basis of the intention-to-treat cohort. The effect of access site on mortality and major bleeding was assessed further by multivariable analysis. The relationship among access site, bleeding, and mortality was investigated by natural effect model mediation analysis with multivariable adjustment. RESULTS: A total of 21 600 patients (10 775 TRA, 10 825 TFA) from 7 randomized clinical trials were included. The median age was 63.9 years, 31.9% were women, 95% presented with acute coronary syndrome, and 75.2% underwent percutaneous coronary intervention. All-cause mortality (1.6% versus 2.1%; hazard ratio, 0.77 [95% CI, 0.63-0.95]; P=0.012) and major bleeding (1.5% versus 2.7%; odds ratio, 0.55 [95% CI, 0.45-0.67]; P<0.001) were lower with TRA. Subgroup analyses for mortality showed consistent results, except for baseline hemoglobin level (Pinteraction=0.003), indicating that the benefit of TRA was substantial in patients with moderate or severe anemia, whereas it was not significant in patients with milder or no baseline anemia. After adjustment, TRA remained associated with 24% and 51% relative risk reduction of all-cause mortality and major bleeding, respectively. A mediation analysis showed that the benefit of TRA on mortality was only partially driven by major bleeding prevention and ancillary mechanisms are required to fully explain the causal association. CONCLUSIONS: TRA is associated with lower all-cause mortality and major bleeding at 30 days compared with TFA. The effect on mortality was driven by patients with anemia. The reduction in major bleeding only partially explains the mortality benefit. REGISTRATION: URL: https://www.crd.york.ac.uk/prospero; Unique identifier: CRD42018109664.


Assuntos
Angiografia Coronária , Intervenção Coronária Percutânea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia Coronária/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Hemorragia/etiologia , Estudos Multicêntricos como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Artéria Radial , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Resultado do Tratamento
6.
Europace ; 24(9): 1441-1450, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35253840

RESUMO

AIMS: No studies have compared Watchman 2.5 (W2.5) with Watchman FLX (FLX) devices to date. We aimed at comparing the FLX with W2.5 devices with respect to clinical outcomes, left atrial appendage (LAA) sealing properties and device-related thrombus (DRT). METHODS AND RESULTS: All consecutive left atrial appendage closure (LAAC) procedures performed at two European centres between November 2017 and February 2021 were included. Procedure-related complications and net adverse cardiovascular events (NACE) at 6 months after LAAC were recorded. At 45-day computed tomography (CT) follow-up, intra- (IDL) and peri- (PDL) device leak, residual patent neck area (RPNA), and DRT were assessed by a Corelab. Out of 144 LAAC consecutive procedures, 71 and 73 interventions were performed using W2.5 and FLX devices, respectively. There were no differences in terms of procedure-related complications (4.2% vs. 2.7%, P = 0.626). At 45-day CT, the FLX was associated with lower frequency of IDL [21.3% vs. 40.0%; P = 0.032; odds ratio (OR): 0.375; 95% confidence interval (CI): 0.160-0.876; P = 0.024], similar rate of PDL (29.5% vs. 42.0%; P = 0.170), and smaller RPNA [6 (0-36) vs. 40 (6-115) mm2; P = 0.001; OR: 0.240; 95% CI: 0.100-0.577; P = 0.001] compared with the W2.5 group. At 45 days, rate of DRT as detected by CT and/or transoesophageal echocardiography (TOE), was higher with W2.5 (6.0% vs. 0%, P = 0.045). At 6-month follow-up, NACE did not differ between groups. CONCLUSIONS: In this cohort of consecutive LAACs, FLX as compared to W2.5, was associated with similar procedure-related complications and 6-month NACE, but with improved LAA neck coverage, and lower IDL and DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Trombose , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana , Humanos , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/prevenção & controle , Trombose/etiologia , Trombose/prevenção & controle , Resultado do Tratamento
7.
Eur Heart J ; 42(21): 2103-2112, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33351135

RESUMO

AIMS: Since dietary sodium intake has been identified as a risk factor for cardiovascular disease and premature death, a high sodium intake can be expected to curtail life span. We tested this hypothesis by analysing the relationship between sodium intake and life expectancy as well as survival in 181 countries worldwide. METHODS AND RESULTS: We correlated age-standardized estimates of country-specific average sodium consumption with healthy life expectancy at birth and at age of 60 years, death due to non-communicable diseases and all-cause mortality for the year of 2010, after adjusting for potential confounders such as gross domestic product per capita and body mass index. We considered global health estimates as provided by World Health Organization. Among the 181 countries included in this analysis, we found a positive correlation between sodium intake and healthy life expectancy at birth (ß = 2.6 years/g of daily sodium intake, R2 = 0.66, P < 0.001), as well as healthy life expectancy at age 60 (ß = 0.3 years/g of daily sodium intake, R2 = 0.60, P = 0.048) but not for death due to non-communicable diseases (ß = 17 events/g of daily sodium intake, R2 = 0.43, P = 0.100). Conversely, all-cause mortality correlated inversely with sodium intake (ß = -131 events/g of daily sodium intake, R2 = 0.60, P < 0.001). In a sensitivity analysis restricted to 46 countries in the highest income class, sodium intake continued to correlate positively with healthy life expectancy at birth (ß = 3.4 years/g of daily sodium intake, R2 = 0.53, P < 0.001) and inversely with all-cause mortality (ß = -168 events/g of daily sodium intake, R2 = 0.50, P < 0.001). CONCLUSION: Our observation of sodium intake correlating positively with life expectancy and inversely with all-cause mortality worldwide and in high-income countries argues against dietary sodium intake being a culprit of curtailing life span or a risk factor for premature death. These data are observational and should not be used as a base for nutritional interventions.


Assuntos
Doenças não Transmissíveis , Sódio na Dieta , Saúde Global , Humanos , Recém-Nascido , Expectativa de Vida , Pessoa de Meia-Idade , Mortalidade , Mortalidade Prematura
8.
JAMA ; 327(18): 1771-1781, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35368058

RESUMO

Importance: Coronary plaques that are prone to rupture and cause adverse cardiac events are characterized by large plaque burden, large lipid content, and thin fibrous caps. Statins can halt the progression of coronary atherosclerosis; however, the effect of the proprotein convertase subtilisin kexin type 9 inhibitor alirocumab added to statin therapy on plaque burden and composition remains largely unknown. Objective: To determine the effects of alirocumab on coronary atherosclerosis using serial multimodality intracoronary imaging in patients with acute myocardial infarction. Design, Setting, and Participants: The PACMAN-AMI double-blind, placebo-controlled, randomized clinical trial (enrollment: May 9, 2017, through October 7, 2020; final follow-up: October 13, 2021) enrolled 300 patients undergoing percutaneous coronary intervention for acute myocardial infarction at 9 academic European hospitals. Interventions: Patients were randomized to receive biweekly subcutaneous alirocumab (150 mg; n = 148) or placebo (n = 152), initiated less than 24 hours after urgent percutaneous coronary intervention of the culprit lesion, for 52 weeks in addition to high-intensity statin therapy (rosuvastatin, 20 mg). Main Outcomes and Measures: Intravascular ultrasonography (IVUS), near-infrared spectroscopy, and optical coherence tomography were serially performed in the 2 non-infarct-related coronary arteries at baseline and after 52 weeks. The primary efficacy end point was the change in IVUS-derived percent atheroma volume from baseline to week 52. Two powered secondary end points were changes in near-infrared spectroscopy-derived maximum lipid core burden index within 4 mm (higher values indicating greater lipid content) and optical coherence tomography-derived minimal fibrous cap thickness (smaller values indicating thin-capped, vulnerable plaques) from baseline to week 52. Results: Among 300 randomized patients (mean [SD] age, 58.5 [9.7] years; 56 [18.7%] women; mean [SD] low-density lipoprotein cholesterol level, 152.4 [33.8] mg/dL), 265 (88.3%) underwent serial IVUS imaging in 537 arteries. At 52 weeks, mean change in percent atheroma volume was -2.13% with alirocumab vs -0.92% with placebo (difference, -1.21% [95% CI, -1.78% to -0.65%], P < .001). Mean change in maximum lipid core burden index within 4 mm was -79.42 with alirocumab vs -37.60 with placebo (difference, -41.24 [95% CI, -70.71 to -11.77]; P = .006). Mean change in minimal fibrous cap thickness was 62.67 µm with alirocumab vs 33.19 µm with placebo (difference, 29.65 µm [95% CI, 11.75-47.55]; P = .001). Adverse events occurred in 70.7% of patients treated with alirocumab vs 72.8% of patients receiving placebo. Conclusions and Relevance: Among patients with acute myocardial infarction, the addition of subcutaneous biweekly alirocumab, compared with placebo, to high-intensity statin therapy resulted in significantly greater coronary plaque regression in non-infarct-related arteries after 52 weeks. Further research is needed to understand whether alirocumab improves clinical outcomes in this population. Trial Registration: ClinicalTrials.gov Identifier: NCT03067844.


Assuntos
Doença da Artéria Coronariana , Inibidores de Hidroximetilglutaril-CoA Redutases , Infarto do Miocárdio , Inibidores de PCSK9 , Placa Aterosclerótica , Idoso , Anticorpos Monoclonais Humanizados/uso terapêutico , LDL-Colesterol , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Método Duplo-Cego , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/tratamento farmacológico , Inibidores de PCSK9/uso terapêutico , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/tratamento farmacológico , Resultado do Tratamento
9.
BMC Med ; 19(1): 304, 2021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-34809639

RESUMO

BACKGROUND: Selective outcome reporting and publication bias threaten the validity of systematic reviews and meta-analyses and can affect clinical decision-making. A rigorous method to evaluate the impact of this bias on the results of network meta-analyses of interventions is lacking. We present a tool to assess the Risk Of Bias due to Missing Evidence in Network meta-analysis (ROB-MEN). METHODS: ROB-MEN first evaluates the risk of bias due to missing evidence for each of the possible pairwise comparison that can be made between the interventions in the network. This step considers possible bias due to the presence of studies with unavailable results (within-study assessment of bias) and the potential for unpublished studies (across-study assessment of bias). The second step combines the judgements about the risk of bias due to missing evidence in pairwise comparisons with (i) the contribution of direct comparisons to the network meta-analysis estimates, (ii) possible small-study effects evaluated by network meta-regression, and (iii) any bias from unobserved comparisons. Then, a level of "low risk", "some concerns", or "high risk" for the bias due to missing evidence is assigned to each estimate, which is our tool's final output. RESULTS: We describe the methodology of ROB-MEN step-by-step using an illustrative example from a published NMA of non-diagnostic modalities for the detection of coronary artery disease in patients with low risk acute coronary syndrome. We also report a full application of the tool on a larger and more complex published network of 18 drugs from head-to-head studies for the acute treatment of adults with major depressive disorder. CONCLUSIONS: ROB-MEN is the first tool for evaluating the risk of bias due to missing evidence in network meta-analysis and applies to networks of all sizes and geometry. The use of ROB-MEN is facilitated by an R Shiny web application that produces the Pairwise Comparisons and ROB-MEN Table and is incorporated in the reporting bias domain of the CINeMA framework and software.


Assuntos
Metanálise em Rede , Viés de Publicação , Adulto , Transtorno Depressivo Maior , Humanos , Medição de Risco
10.
Catheter Cardiovasc Interv ; 98(7): 1404-1412, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34406713

RESUMO

OBJECTIVES: To investigate whether the integrative echocardiographic criteria used in the cardiovascular outcomes assessment of the mitraclip percutaneous therapy (COAPT) for heart failure patients with functional mitral regurgitation study predict outcomes after edge-to-edge trancatheter mitral valve repair (TMVr) for the treatment of secondary mitral regurgitation (SMR). BACKGROUND: Two randomized controlled trials comparing TMVr to medical treatment reported conflicting findings. Differences in patient selection criteria may have contributed to these diverging results. METHODS: Patients undergoing TMVr were stratified following the integrative COAPT echocardiographic criteria in noneligible and eligible patients who were further classified into three tiers according to effective regurgitant orifice (EROA) (Tier 1: EROA ≥ 0.3cm2 ; Tier 2: EROA 0.2cm2 and 0.29cm2 ; Tier 3: EROA<0.2cm2 ) combined with several other severity criteria. We assessed between group differences in all-cause mortality, successful SMR reduction, and symptom relief from baseline to 2-year follow-up. RESULTS: Between March 2011 and March 2018, 138 patients (mean age 75 years) satisfying the inclusion criteria underwent TMVr for treatment of symptomatic SMR. The mean EROA area was 0.35 ± 0.17 mm2 . Ten patients (7%) died within 30 days, 29 (21%) within 12 months, and 41 (30%) within 2 years. After stratification according to the COAPT echocardiographic criteria that were fulfilled in 72% of the studied population, Tier 2 patients (45%), as well as noneligible patients (38%) had a higher mortality rate compared to those in Tier 1 (19%). CONCLUSIONS: SMR patients stratified into tiers according to the COAPT integrative echocardiographic criteria have diverging prognostic and symptomatic benefit after edge-to-edge TMVr.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
11.
Eur Heart J ; 41(38): 3743-3749, 2020 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-33029615

RESUMO

AIMS: To validate the set of clinical and biochemical criteria proposed by consensus by the Academic Research Consortium (ARC) for High Bleeding Risk (HBR) for the identification of HBR patients. These criteria were categorized into major and minor, if expected to carry in isolation, respectively, ≥4% and <4% Bleeding Academic Research Consortium (BARC) 3 or 5 bleeding risk within 1-year after percutaneous coronary intervention (PCI). High bleeding risk patients are those meeting at least 1 major or 2 minor criteria. METHODS AND RESULTS: All patients undergoing PCI at Bern University Hospital, between February 2009 and September 2018 were prospectively entered into the Bern PCI Registry (NCT02241291). Age, haemoglobin, platelet count, creatinine, and use of oral anticoagulation were prospectively collected, while the remaining HBR criteria except for planned surgery were retrospectively adjudicated. A total of 16 580 participants with complete ARC-HBR criteria were included. After assigning 1 point to each major and 0.5 point to each minor criterion, we observed for every 0.5 score increase a step-wise augmentation of BARC 3 or 5 bleeding rates at 1 year ranging from 1.90% among patients fulfilling no criterion, through 4.01%, 5.98%, 7.42%, 8.60%, 12.21%, 12.29%, and 17.64%. All major and five out of six minor criteria, conferred in isolation a risk for BARC 3 or 5 bleeding at 1 year exceeding 4% at the upper limit of the 95% confidence intervals. CONCLUSION: All major and the majority of minor ARC-HBR criteria identify in isolation patients at HBR.


Assuntos
Intervenção Coronária Percutânea , Hemorragia/induzido quimicamente , Humanos , Inibidores da Agregação Plaquetária , Estudos Retrospectivos , Fatores de Risco
12.
Eur Heart J ; 45(7): 553-554, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38087906
13.
Eur Heart J ; 40(38): 3143-3153, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31329852

RESUMO

AIMS: Owing to new evidence from randomized controlled trials (RCTs) in low-risk patients with severe aortic stenosis, we compared the collective safety and efficacy of transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) across the entire spectrum of surgical risk patients. METHODS AND RESULTS: The meta-analysis is registered with PROSPERO (CRD42016037273). We identified RCTs comparing TAVI with SAVR in patients with severe aortic stenosis reporting at different follow-up periods. We extracted trial, patient, intervention, and outcome characteristics following predefined criteria. The primary outcome was all-cause mortality up to 2 years for the main analysis. Seven trials that randomly assigned 8020 participants to TAVI (4014 patients) and SAVR (4006 patients) were included. The combined mean STS score in the TAVI arm was 9.4%, 5.1%, and 2.0% for high-, intermediate-, and low surgical risk trials, respectively. Transcatheter aortic valve implantation was associated with a significant reduction of all-cause mortality compared to SAVR {hazard ratio [HR] 0.88 [95% confidence interval (CI) 0.78-0.99], P = 0.030}; an effect that was consistent across the entire spectrum of surgical risk (P-for-interaction = 0.410) and irrespective of type of transcatheter heart valve (THV) system (P-for-interaction = 0.674). Transcatheter aortic valve implantation resulted in lower risk of strokes [HR 0.81 (95% CI 0.68-0.98), P = 0.028]. Surgical aortic valve replacement was associated with a lower risk of major vascular complications [HR 1.99 (95% CI 1.34-2.93), P = 0.001] and permanent pacemaker implantations [HR 2.27 (95% CI 1.47-3.64), P < 0.001] compared to TAVI. CONCLUSION: Compared with SAVR, TAVI is associated with reduction in all-cause mortality and stroke up to 2 years irrespective of baseline surgical risk and type of THV system.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
14.
Circulation ; 137(2): 184-196, 2018 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-29311349

RESUMO

A series of hemodynamic and pathological responses occur in chronic aortic regurgitation, which eventually result in myocardial fibrosis and irreversible left ventricular dysfunction. According to guidelines, valvular surgery is recommended with the development of symptoms, left ventricular systolic dysfunction, or left ventricular dilatation. The optimal timing of surgical intervention has recently been questioned with documentation of irreversible myocardial damage resulting in incomplete left ventricular recovery and adverse clinical outcomes after surgery. Recognizing the shortcomings of the guidelines, we performed a comprehensive review on the novel diagnostic methods that have been shown to improve the detection of subclinical ventricular dysfunction in chronic aortic regurgitation and to improve prediction of outcomes.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/terapia , Doenças Assintomáticas , Fármacos Cardiovasculares/uso terapêutico , Doença Crônica , Progressão da Doença , Diagnóstico Precoce , Feminino , Fibrose , Implante de Prótese de Valva Cardíaca , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Hipertrofia Ventricular Esquerda/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda/efeitos dos fármacos , Remodelação Ventricular/efeitos dos fármacos
15.
Lancet ; 392(10149): 737-746, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30170848

RESUMO

BACKGROUND: Drug-eluting stents combining an ultrathin cobalt-chromium stent platform with a biodegradable polymer eluting sirolimus have been shown to be non-inferior or superior to thin-strut, durable-polymer, everolimus-eluting stents in terms of 1 year safety and efficacy outcomes. METHODS: In the randomised, single-blind, multicentre, non-inferiority BIOSCIENCE trial, we compared biodegradable-polymer sirolimus-eluting stents with durable-polymer everolimus-eluting stents in patients with chronic stable coronary artery disease or acute coronary syndromes. Here, we assess the final 5-year clinical outcomes of BIOSCIENCE with regards to the primary clinical outcome of target lesion failure, which was a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation. The primary analysis was done by intention to treat. The BIOSCIENCE trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS: 2008 (95%) of 2119 patients recruited between March 1, 2012, and May 31, 2013, completed 5 years of follow-up. Target lesion failure occurred in 198 patients (cumulative incidence 20·2%) treated with biodegradable-polymer sirolimus-eluting stents and in 189 patients (18·8%) treated with durable-polymer everolimus-eluting stents (rate ratio [RR] 1·07, 95% CI 0·88-1·31; p=0·487). All-cause mortality was significantly higher in patients treated with biodegradable-polymer sirolimus-eluting stents than in those treated with durable-polymer everolimus-eluting stents (14·1% vs 10·3%; RR 1·36, 95% CI 1·06-1·75; p=0·017), driven by a difference in non-cardiovascular deaths. We observed no difference between groups in cumulative incidence of definite stent thrombosis at 5 years (1·6% in both groups; 1·02, 0·51-2·05; p=0·950). INTERPRETATION: 5-year risk of target lesion failure among all-comer patients undergoing percutaneous coronary intervention is similar after implantation of ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents or thin-strut, durable-polymer, everolimus-eluting stents. Higher incidences of all-cause and non-cardiovascular mortality in patients treated with biodegradable-polymer stents eluting sirolimus than in those treated with durable-polymer stents eluting everolimus warrant careful observation in ongoing clinical trials. FUNDING: Clinical Trials Unit of the University of Bern and Biotronik.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Implantes Absorvíveis , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Polímeros , Desenho de Prótese , Falha de Prótese/etiologia , Método Simples-Cego , Trombose/etiologia , Resultado do Tratamento
16.
Eur Heart J ; 44(26): 2358-2360, 2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37061814
18.
Eur Heart J ; 39(14): 1172-1180, 2018 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-29069377

RESUMO

Aims: Current evidence on dyslipidaemia management has expanded to novel treatments and very low achieved levels of low-density lipoprotein cholesterol (LDL-C). We sought to compare the clinical impact of more-intensive vs. less-intensive LDL-C lowering by means of statins and currently recommended non-statin medications in secondary prevention. Methods and results: We searched Medline, EMBASE, and Cochrane databases for randomized controlled trials of statins, ezetimibe, proprotein convertase subtilisin-kexin type 9 (PCSK9) inhibitors, or bile acid sequestrants with >500 patients followed for ≥1 year. We employed random-effects models using risk ratios (RRs) with 95% confidence intervals (CIs) to compare outcomes. We included 19 trials (15 of statins, 3 of PCSK9 inhibitors, and 1 of ezetimibe) with 152 507 patients randomly assigned to more-intensive (n = 76 678) or less-intensive treatment (n = 75 829). More-intensive treatment was associated with 19% relative risk reduction for the primary outcome, major vascular events (MVEs; RR 0.81, 95% CI 0.77-0.86). Risk reduction was greater across higher baseline levels and greater achieved reductions of LDL-C. The clinical benefit was significant across varying types of more-intensive treatment and was consistent for statins (RR 0.81, 95% CI 0.76-0.86) and non-statin agents (PCSK9 inhibitors and ezetimibe; RR 0.85, 95% CI 0.77-0.94) as active (more-intensive) intervention (P-interaction = 0.38). Each 1.0 mmol/L reduction in LDL-C was associated with 19% relative decrease in MVE. Death, cardiovascular death, myocardial infarction, stroke, and coronary revascularization also favoured more-intensive treatment. Conclusion: Reduction of MVE is proportional to the magnitude of LDL-C lowering across a broad spectrum of on-treatment levels in secondary prevention. Statin intensification and add-on treatment with PCSK9 inhibitors or ezetimibe are associated with significant reduction of cardiovascular morbidity in this very high-risk population.


Assuntos
Anticolesterolemiantes/uso terapêutico , Doenças Cardiovasculares/prevenção & controle , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Prevenção Secundária/métodos , LDL-Colesterol/sangue , Ezetimiba/uso terapêutico , Humanos , Inibidores de PCSK9 , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA