Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Acoust Soc Am ; 153(1): 7, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36732278

RESUMO

This work describes a 35.9 kHz ultrasonic transducer that incorporates a magnetic arrangement to apply a static-compressive prestress to a d32-mode relaxor ferroelectric single crystal drive-element. The magnetic arrangement produces a 22.5 N static-compressive force, inducing a static compression of ∼630 nm on the drive-element. Operating in air with a continuous-wave 10 V peak drive at ∼35.9 kHz, the measured resonant peak displacement of the transducers head-mass was 127 nm. This is well within the predicted static compression, thus, the drive-element is protected from damaging tensile stress. Under the same drive conditions and at an axial distance of 10 mm from the face of the head-mass, the measured acoustic pressure was ∼12 Pa. Analytical and finite element model predictions and the measured behaviour of a prototype device are presented and show good correlation, demonstrating that magnetic prestressing of the drive-element can be a viable alternative to the traditional bolt-clamp.

2.
Materials (Basel) ; 10(7)2017 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-28773193

RESUMO

A key longstanding objective of the Structural Health Monitoring (SHM) research community is to enable the embedment of SHM systems in high value assets like aircraft to provide on-demand damage detection and evaluation. As against traditional non-destructive inspection hardware, embedded SHM systems must be compact, lightweight, low-power and sufficiently robust to survive exposure to severe in-flight operating conditions. Typical Commercial-Off-The-Shelf (COTS) systems can be bulky, costly and are often inflexible in their configuration and/or scalability, which militates against in-service deployment. Advances in electronics have resulted in ever smaller, cheaper and more reliable components that facilitate the development of compact and robust embedded SHM systems, including for Acousto-Ultrasonics (AU), a guided plate-wave inspection modality that has attracted strong interest due mainly to its capacity to furnish wide-area diagnostic coverage with a relatively low sensor density. This article provides a detailed description of the development, testing and demonstration of a new AU interrogation system called the Acousto Ultrasonic Structural health monitoring Array Module⁺ (AUSAM⁺). This system provides independent actuation and sensing on four Piezoelectric Wafer Active Sensor (PWAS) elements with further sensing on four Positive Intrinsic Negative (PIN) photodiodes for intensity-based interrogation of Fiber Bragg Gratings (FBG). The paper details the development of a novel piezoelectric excitation amplifier, which, in conjunction with flexible acquisition-system architecture, seamlessly provides electromechanical impedance spectroscopy for PWAS diagnostics over the full instrument bandwidth of 50 KHz-5 MHz. The AUSAM⁺ functionality is accessed via a simple hardware object providing a myriad of custom software interfaces that can be adapted to suit the specific requirements of each individual application.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA