Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Spine J ; 33(5): 2031-2042, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38548932

RESUMO

PURPOSE: To assess whether the intention to intraoperatively reposition pedicle screws differs when spine surgeons evaluate the same screws with 2D imaging or 3D imaging. METHODS: In this online survey study, 21 spine surgeons evaluated eight pedicle screws from patients who had undergone posterior spinal fixation. In a simulated intraoperative setting, surgeons had to decide if they would reposition a marked pedicle screw based on its position in the provided radiologic imaging. The eight assessed pedicle screws varied in radiologic position, including two screws positioned within the pedicle, two breaching the pedicle cortex < 2 mm, two breaching the pedicle cortex 2-4 mm, and two positioned completely outside the pedicle. Surgeons assessed each pedicle screw twice without knowing and in random order: once with a scrollable three-dimensional (3D) image and once with two oblique fluoroscopic two-dimensional (2D) images. RESULTS: Almost all surgeons (19/21) intended to reposition more pedicle screws based on 3D imaging than on 2D imaging, with a mean number of pedicle screws to be repositioned of, respectively, 4.1 (± 1.3) and 2.0 (± 1.3; p < 0.001). Surgeons intended to reposition two screws placed completely outside the pedicle, one breaching 2-4mm, and one breaching < 2 mm more often based on 3D imaging. CONCLUSION: When provided with 3D imaging, spine surgeons not only intend to intraoperatively reposition pedicle screws at risk of causing postoperative complications more often but also screws with acceptable positions. This study highlights the potential of intraoperative 3D imaging as well as the need for consensus on how to act on intraoperative 3D information.


Assuntos
Parafusos Pediculares , Humanos , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Coluna Vertebral/diagnóstico por imagem , Tomada de Decisão Clínica/métodos , Imageamento Tridimensional/métodos , Inquéritos e Questionários , Cirurgiões
2.
BMC Cancer ; 23(1): 771, 2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37596578

RESUMO

BACKGROUND: High dose unilobar radioembolization (also termed 'radiation lobectomy')-the transarterial unilobar infusion of radioactive microspheres as a means of controlling tumour growth while concomitantly inducing future liver remnant hypertrophy-has recently gained interest as induction strategy for surgical resection. Prospective studies on the safety and efficacy of the unilobar radioembolization-surgery treatment algorithm are lacking. The RALLY study aims to assess the safety and toxicity profile of holmium-166 unilobar radioembolization in patients with hepatocellular carcinoma ineligible for surgery due to insufficiency of the future liver remnant. METHODS: The RALLY study is a multicenter, interventional, non-randomized, open-label, non-comparative safety study. Patients with hepatocellular carcinoma who are considered ineligible for surgery due to insufficiency of the future liver remnant (< 2.7%/min/m2 on hepatobiliary iminodiacetic acid scan will be included. A classical 3 + 3 dose escalation model will be used, enrolling three to six patients in each cohort. The primary objective is to determine the maximum tolerated treated non-tumourous liver-absorbed dose (cohorts of 50, 60, 70 and 80 Gy). Secondary objectives are to evaluate dose-response relationships, to establish the safety and feasibility of surgical resection following unilobar radioembolization, to assess quality of life, and to generate a biobank. DISCUSSION: This will be the first clinical study to assess the unilobar radioembolization-surgery treatment algorithm and may serve as a stepping stone towards its implementation in routine clinical practice. TRIAL REGISTRATION: Netherlands Trial Register NL8902 , registered on 2020-09-15.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/radioterapia , Microesferas , Estudos Prospectivos , Qualidade de Vida , Neoplasias Hepáticas/radioterapia , Hepatomegalia , Estudos Multicêntricos como Assunto
3.
Eur J Nucl Med Mol Imaging ; 48(5): 1658-1668, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33128132

RESUMO

PURPOSE: The objective of this study was to investigate whether the use of an anti-reflux catheter improves tumor targeting for colorectal cancer patients with unresectable, chemorefractory liver metastases (mCRC) treated with holmium-166 (166Ho)-radioembolization. MATERIALS AND METHODS: In this perspective, within-patient randomized study, left and right hepatic perfusion territories were randomized between infusion with a Surefire® anti-reflux catheter or a standard microcatheter. The primary outcome was the difference in tumor to non-tumor (T/N) activity distribution. Secondary outcomes included the difference in infusion efficiency, absorbed doses, predictive value of 166Ho-scout, dose-response relation, and survival. RESULTS: Twenty-one patients were treated in this study (the intended number of patients was 25). The median T/N activity concentration ratio with the use of the anti-reflux catheter was 3.2 (range 0.9-8.7) versus 3.6 (range 0.8-13.3) with a standard microcatheter. There was no difference in infusion efficiency (0.04% vs. 0.03% residual activity for the standard microcatheter and anti-reflux catheter, respectively) (95%CI - 0.05-0.03). No influence of the anti-reflux catheter on the dose-response rate was found. Median overall survival was 7.8 months (95%CI 6-13). CONCLUSION: Using a Surefire® anti-reflux catheter did not result in a higher T/N activity concentration ratio in mCRC patients treated with 166Ho-radioembolization, nor did it result in improved secondary outcomes measures. TRIAL REGISTRATION: clinicaltrials.gov identifier: NCT02208804.


Assuntos
Neoplasias Colorretais , Embolização Terapêutica , Neoplasias Hepáticas , Catéteres , Neoplasias Colorretais/radioterapia , Hólmio/uso terapêutico , Humanos , Neoplasias Hepáticas/radioterapia , Estudos Prospectivos , Radioisótopos , Radioisótopos de Ítrio/uso terapêutico
4.
Eur J Nucl Med Mol Imaging ; 47(4): 798-806, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31399801

RESUMO

PURPOSE: As an alternative to technetium-99m-macroaggregated albumin (99mTc-MAA), a scout dose of holmium-166 (166Ho) microspheres can be used prior to 166Ho-radioembolization. The use of identical particles for pre-treatment and treatment procedures may improve the predictive value of pre-treatment analysis of distribution. The aim of this study was to analyze the agreement between 166Ho-scout and 166Ho-therapeutic dose in comparison with the agreement between 99mTc-MAA and 166Ho-therapeutic dose. METHODS: Two separate scout dose procedures were performed (99mTc-MAA and 166Ho-scout) before treatment in 53 patients. First, qualitative assessment was performed by two blinded nuclear medicine physicians who visually rated the agreement between the 99mTc-MAA, 166Ho-scout, and 166Ho-therapeutic dose SPECT-scans (i.e., all performed in the same patient) on a 5-point scale. Second, agreement was measured quantitatively by delineating lesions and normal liver on FDG-PET/CT. These volumes of interest (VOIs) were co-registered to the SPECT/CT images. The predicted absorbed doses (based on 99mTc-MAA and 166Ho-scout) were compared with the actual absorbed dose on post-treatment SPECT. RESULTS: A total of 23 procedures (71 lesions, 22 patients) were included for analysis. In the qualitative analysis, 166Ho-scout was superior with a median score of 4 vs. 2.5 for 99mTc-MAA (p < 0.001). The quantitative analysis showed significantly narrower 95%-limits of agreement for 166Ho-scout in comparison with 99mTc-MAA when evaluating lesion absorbed dose (- 90.3 and 105.3 Gy vs. - 164.1 and 197.0 Gy, respectively). Evaluation of normal liver absorbed dose did not show difference in agreement between both scout doses and 166Ho-therapeutic dose (- 2.9 and 5.5 Gy vs - 3.6 and 4.1 Gy for 99mTc-MAA and 166Ho-scout, respectively). CONCLUSIONS: In this study, 166Ho-scout was shown to have a superior predictive value for intrahepatic distribution in comparison with 99mTc-MAA.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Albuminas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Microesferas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio
5.
J Vasc Interv Radiol ; 31(10): 1593-1599, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32861571

RESUMO

PURPOSE: To evaluate the safety and feasibility of same-day treatment, including the simulation procedure for assessment of intrahepatic and extrahepatic distribution of the microspheres, with holmium-166 (166Ho)-radioembolization. MATERIALS AND METHODS: This was a secondary analysis of patients included in the 4 prospective studies (HEPAR I, HEPAR II, HEPAR PLuS, and SIM) on 166Ho-radioembolization. The technical success rate of the same-day treatment protocol, defined as the number of patients who completed the same-day treatment, was measured. Total in-room time, duration of the scout procedure, time to imaging, and duration of the treatment procedure were recorded. Reasons for discontinuation or adjustment of treatment were identified. Adverse events that occurred during the treatment day were recorded. RESULTS: One hundred five of 120 scheduled patients completed the same-day treatment with 166Ho-radioembolization (success rate, 88%). After the simulation procedure, treatment was cancelled in 15 patients because of extrahepatic deposition (n = 8), suboptimal tumor targeting (n = 1), unanticipated vascular anatomy (n = 5), and dissection (n = 1). In another 14 patients, the treatment plan was adjusted. The median total procedure time (ie, simulation, imaging, and treatment) was 6:39 hours:minutes (range, 3:58-9:17 hours:minutes). Back pain was a major same-day treatment-related complaint (n = 28). CONCLUSION: 166Ho-radioembolization as a same-day treatment procedure is feasible in most selected patients, although treatment was adjusted in 12% of patients and cancelled in 12% of patients. This approach might be beneficial for a select patient population, such as patients needing a radiation segmentectomy.


Assuntos
Embolização Terapêutica , Hólmio/administração & dosagem , Neoplasias Hepáticas/radioterapia , Radioisótopos/administração & dosagem , Compostos Radiofarmacêuticos/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Embolização Terapêutica/efeitos adversos , Estudos de Viabilidade , Feminino , Hólmio/efeitos adversos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Microesferas , Pessoa de Meia-Idade , Doses de Radiação , Radioisótopos/efeitos adversos , Compostos Radiofarmacêuticos/efeitos adversos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Eur J Nucl Med Mol Imaging ; 41(10): 1965-75, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24819055

RESUMO

PURPOSE: Radiation pneumonitis is a rare but serious complication of radioembolic therapy of liver tumours. Estimation of the mean absorbed dose to the lungs based on pretreatment diagnostic (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) imaging should prevent this, with administered activities adjusted accordingly. The accuracy of (99m)Tc-MAA-based lung absorbed dose estimates was evaluated and compared to absorbed dose estimates based on pretreatment diagnostic (166)Ho-microsphere imaging and to the actual lung absorbed doses after (166)Ho radioembolization. METHODS: This prospective clinical study included 14 patients with chemorefractory, unresectable liver metastases treated with (166)Ho radioembolization. (99m)Tc-MAA-based and (166)Ho-microsphere-based estimation of lung absorbed doses was performed on pretreatment diagnostic planar scintigraphic and SPECT/CT images. The clinical analysis was preceded by an anthropomorphic torso phantom study with simulated lung shunt fractions of 0 to 30 % to determine the accuracy of the image-based lung absorbed dose estimates after (166)Ho radioembolization. RESULTS: In the phantom study, (166)Ho SPECT/CT-based lung absorbed dose estimates were more accurate (absolute error range 0.1 to -4.4 Gy) than (166)Ho planar scintigraphy-based lung absorbed dose estimates (absolute error range 9.5 to 12.1 Gy). Clinically, the actual median lung absorbed dose was 0.02 Gy (range 0.0 to 0.7 Gy) based on posttreatment (166)Ho-microsphere SPECT/CT imaging. Lung absorbed doses estimated on the basis of pretreatment diagnostic (166)Ho-microsphere SPECT/CT imaging (median 0.02 Gy, range 0.0 to 0.4 Gy) were significantly better predictors of the actual lung absorbed doses than doses estimated on the basis of (166)Ho-microsphere planar scintigraphy (median 10.4 Gy, range 4.0 to 17.3 Gy; p < 0.001), (99m)Tc-MAA SPECT/CT imaging (median 2.5 Gy, range 1.2 to 12.3 Gy; p < 0.001), and (99m)Tc-MAA planar scintigraphy (median 5.5 Gy, range 2.3 to 18.2 Gy; p < 0.001). CONCLUSION: In clinical practice, lung absorbed doses are significantly overestimated by pretreatment diagnostic (99m)Tc-MAA imaging. Pretreatment diagnostic (166)Ho-microsphere SPECT/CT imaging accurately predicts lung absorbed doses after (166)Ho radioembolization.


Assuntos
Embolização Terapêutica/métodos , Hólmio/farmacocinética , Neoplasias Pulmonares/radioterapia , Microesferas , Radioisótopos/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Agregado de Albumina Marcado com Tecnécio Tc 99m/farmacocinética , Adulto , Idoso , Idoso de 80 Anos ou mais , Embolização Terapêutica/efeitos adversos , Feminino , Hólmio/efeitos adversos , Hólmio/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radioisótopos/efeitos adversos , Radioisótopos/uso terapêutico , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Tomografia Computadorizada de Emissão de Fóton Único
7.
J Vasc Interv Radiol ; 25(12): 1956-1963.e1, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25311966

RESUMO

PURPOSE: To assess the radiation exposure to individuals coming from patients after treatment with holmium-166 ((166)Ho) microspheres. MATERIALS AND METHODS: Holmium-166 radioembolization (RE) with escalating whole-liver doses of 20 Gy, 40 Gy, 60 Gy, and 80 Gy was administered to 15 patients. Exposure rates (µSv/h) from patients were measured at 1.0 m distance from a lateral and frontal position at 0, 3, 6, 24, and 48 hours after infusion. The total effective dose equivalent (TEDE) to a maximally exposed contact was calculated in accordance with guidelines of the U.S. Nuclear Regulatory Commission (NRC). Results were extrapolated to a whole-liver dose of 60 Gy used in future treatments. RESULTS: The median exposure rate at discharge, 48 hours after infusion, measured from a lateral position was 26 µSv/h (range, 7-45 µSv/h). Extrapolated to a whole-liver dose of 60 Gy, none of the exposure rates for the NRC contact scenario, at any time, frontal or lateral, would lead to a TEDE > 5 mSv; all patients may be released directly after treatment. Release after 6 hours is possible without contact restrictions for patients who received up to 7 GBq. CONCLUSIONS: The TEDE to a contact of patients treated with (166)Ho RE would not exceed the NRC limit of 5 mSv. Contact restrictions 6 hours after treatment are unnecessary for infused activities < 7 GBq.


Assuntos
Braquiterapia/métodos , Hólmio/uso terapêutico , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Radioisótopos/uso terapêutico , Feminino , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica
8.
Ned Tijdschr Geneeskd ; 1682024 06 05.
Artigo em Holandês | MEDLINE | ID: mdl-38888409

RESUMO

A 38-year-old woman with urosepsis and persistent unilateral hydronephrosis after antibiotic treatment. Antegrade pyelogram shows urine flow obstruction to the bladder. The whole ureter shows multiple small smooth-walled round lucent filling defects projecting into the lumen. The diagnosis ureteritis cystica was made.


Assuntos
Hidronefrose , Humanos , Feminino , Hidronefrose/etiologia , Hidronefrose/diagnóstico , Adulto , Infecções Urinárias/diagnóstico , Infecções Urinárias/complicações , Infecções Urinárias/tratamento farmacológico , Antibacterianos/uso terapêutico , Doenças Ureterais/diagnóstico , Doenças Ureterais/complicações
9.
PET Clin ; 19(3): 431-446, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38816137

RESUMO

This article provides a thorough overview of the practice and multistep approach of hepatic radioembolization. The current literature on hepatic radioembolization in primary or metastatic liver tumors as well as future perspectives are discussed.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Compostos Radiofarmacêuticos , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Embolização Terapêutica/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos de Ítrio/uso terapêutico , Fígado/diagnóstico por imagem
10.
Cancers (Basel) ; 16(13)2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-39001471

RESUMO

PURPOSE: Liver metastases presenting as small hyperintense foci on diffusion-weighted imaging (DWI) pose a therapeutic challenge. Ablation is generally not possible since these lesions are often occult on ultrasound and CT. The purpose of this prospective study was to assess if small liver metastases (≤10 mm) detected on DWI can be successfully localized and ablated with the Hepatic Arteriography and C-Arm CT-Guided Ablation technique (HepACAGA). MATERIALS AND METHODS: All consecutive patients with small liver metastases (≤10 mm), as measured on DWI, referred for ablation with HepACAGA between 1 January 2021, and 31 October 2023, were included. Re-ablations and ablations concomitant with another local treatment were excluded. The primary outcome was the technical success rate, defined as the intraprocedural detection and subsequent successful ablation of small liver metastases using HepACAGA. Secondary outcomes included the primary and secondary local tumor progression (LTP) rates and the complication rate. RESULTS: A total of 15 patients (26 tumors) were included, with liver metastases from colorectal cancer (73%), neuro-endocrine tumors (15%), breast cancer (8%) and esophageal cancer (4%). All 26 tumors were successfully identified, punctured and ablated (a technical success rate of 100%). After a median follow-up of 9 months, primary and secondary LTP were 4% and 0%, respectively. No complications occurred. CONCLUSION: In this proof-of-concept study, the HepACAGA technique was successfully used to detect and ablate 100% of small liver metastases identified on DWI with a low recurrence rate and no complications. This technique enables the ablation of subcentimeter liver metastases detected on MRI.

11.
Cardiovasc Intervent Radiol ; 47(4): 443-450, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38326577

RESUMO

PURPOSE: Radiation pneumonitis is a serious complication of radioembolization. In holmium-166 ([166Ho]) radioembolization, the lung mean dose (LMD) can be estimated (eLMD) using a scout dose with either technetium-99 m-macroaggregated albumin ([99mTc]MAA) or [166Ho]-microspheres. The accuracy of eLMD based on [99mTc]MAA (eLMDMAA) was compared to eLMD based on [166Ho]-scout dose (eLMDHo-scout) in two prospective clinical studies. MATERIALS AND METHODS: Patients were included if they received both scout doses ([99mTc]MAA and [166Ho]-scout), had a posttreatment [166Ho]-SPECT/CT (gold standard) and were scanned on the same hybrid SPECT/CT system. The correlation between eLMDMAA/eLMDHo-scout and LMDHo-treatment was assessed by Spearman's rank correlation coefficient (r). Wilcoxon signed rank test was used to analyze paired data. RESULTS: Thirty-seven patients with unresectable liver metastases were included. During follow-up, none developed symptoms of radiation pneumonitis. Median eLMDMAA (1.53 Gy, range 0.09-21.33 Gy) was significantly higher than median LMDHo-treatment (0.00 Gy, range 0.00-1.20 Gy; p < 0.01). Median eLMDHo-scout (median 0.00 Gy, range 0.00-1.21 Gy) was not significantly different compared to LMDHo-treatment (p > 0.05). In all cases, eLMDMAA was higher than LMDHo-treatment (p < 0.01). While a significant correlation was found between eLMDHo-scout and LMDHo-treatment (r = 0.43, p < 0.01), there was no correlation between eLMDMAA and LMDHo-treatment (r = 0.02, p = 0.90). CONCLUSION: [166Ho]-scout dose is superior in predicting LMD over [99mTc]MAA, in [166Ho]-radioembolization. Consequently, [166Ho]-scout may limit unnecessary patient exclusions and avoid unnecessary therapeutic activity reductions in patients eligible for radioembolization. TRAIL REGISTRATION: NCT01031784, registered December 2009. NCT01612325, registered June 2012.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Pneumonite por Radiação , Humanos , Estudos Prospectivos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/tratamento farmacológico , Radioisótopos de Ítrio/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Embolização Terapêutica/efeitos adversos , Pulmão/diagnóstico por imagem , Microesferas , Estudos Retrospectivos
12.
EJNMMI Phys ; 11(1): 72, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39143361

RESUMO

BACKGROUND: Subtraction of single-photon emission computed tomography (SPECT) images has a number of clinical applications in e.g. foci localization in ictal/inter-ictal SPECT and defect detection in rest/stress cardiac SPECT. In this work, we investigated the technical performance of SPECT subtraction for the purpose of quantifying the effect of a vasoconstricting drug (angiotensin-II, or AT2) on the Tc-99m-MAA liver distribution in hepatic radioembolization using an innovative interventional hybrid C-arm scanner. Given that subtraction of SPECT images is challenging due to high noise levels and poor resolution, we compared four methods to obtain a difference image in terms of image quality and quantitative accuracy. These methods included (i) image subtraction: subtraction of independently reconstructed SPECT images, (ii) projection subtraction: reconstruction of a SPECT image from subtracted projections, (iii) projection addition: reconstruction by addition of projections as a background term during the iterative reconstruction, and (iv) image addition: simultaneous reconstruction of the difference image and the subtracted image. RESULTS: Digital simulations (XCAT) and phantom studies (NEMA-IQ and anthropomorphic torso) showed that all four methods were able to generate difference images but their performance on specific metrics varied substantially. Image subtraction had the best quantitative performance (activity recovery coefficient) but had the worst visual quality (contrast-to-noise ratio) due to high noise levels. Projection subtraction showed a slightly better visual quality than image subtraction, but also a slightly worse quantitative accuracy. Projection addition had a substantial bias in its quantitative accuracy which increased with less counts in the projections. Image addition resulted in the best visual image quality but had a quantitative bias when the two images to subtract contained opposing features. CONCLUSION: All four investigated methods of SPECT subtraction demonstrated the capacity to generate a feasible difference image from two SPECT images. Image subtraction is recommended when the user is only interested in quantitative values, whereas image addition is recommended when the user requires the best visual image quality. Since quantitative accuracy is most important for the dosimetric investigation of AT2 in radioembolization, we recommend using the image subtraction method for this purpose.

13.
Cancers (Basel) ; 16(10)2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38792003

RESUMO

PURPOSE: Hepatic Arteriography and C-Arm CT-Guided Ablation of liver tumors (HepACAGA) is a novel technique, combining hepatic-arterial contrast injection with C-arm CT-guided navigation. This study compared the outcomes of the HepACAGA technique with patients treated with conventional ultrasound (US) and/or CT-guided ablation. MATERIALS AND METHODS: In this retrospective cohort study, all consecutive patients with hepatocellular carcinoma (HCC) or colorectal liver metastases (CRLM) treated with conventional US-/CT-guided ablation between 1 January 2015, and 31 December 2020, and patients treated with HepACAGA between 1 January 2021, and 31 October 2023, were included. The primary outcome was local tumor recurrence-free survival (LTRFS). Secondary outcomes included the local tumor recurrence (LTR) rate and complication rate. RESULTS: 68 patients (120 tumors) were included in the HepACAGA cohort and 53 patients (78 tumors) were included in the conventional cohort. In both cohorts, HCC was the predominant tumor type (63% and 73%, respectively). In the HepACAGA cohort, all patients received microwave ablation. Radiofrequency ablation was the main ablation technique in the conventional group (78%). LTRFS was significantly longer for patients treated with the HepACAGA technique (p = 0.015). Both LTR and the complication rate were significantly lower in the HepACAGA cohort compared to the conventional cohort (LTR 5% vs. 26%, respectively; p < 0.001) (complication rate 4% vs. 15%, respectively; p = 0.041). CONCLUSIONS: In this study, the HepACAGA technique was safer and more effective than conventional ablation for HCC and CRLM, resulting in lower rates of local tumor recurrence, longer local tumor recurrence-free survival and fewer procedure-related complications.

14.
Cancers (Basel) ; 16(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38539527

RESUMO

With the rapidly evolving field of image-guided tumor ablation, there is an increasing demand and need for tools to optimize treatment success. Known factors affecting the success of (non-)thermal liver ablation procedures are the ability to optimize tumor and surrounding critical structure visualization, ablation applicator targeting, and ablation zone confirmation. A recent study showed superior local tumor progression-free survival and local control outcomes when using transcatheter computed tomography hepatic angiography (CTHA) guidance in percutaneous liver ablation procedures. This pictorial review provides eight clinical cases from three institutions, MD Anderson (Houston, TX, USA), Gustave Roussy (Paris, France), and Amsterdam UMC (Amsterdam, The Netherlands), with the intent to demonstrate the added value of real-time CTHA guided tumor ablation for primary liver tumors and liver-only metastatic disease. The clinical illustrations highlight the ability to improve the detectability of the initial target liver tumor(s) and identify surrounding critical vascular structures, detect 'vanished' and/or additional tumors intraprocedurally, differentiate local tumor progression from non-enhancing scar tissue, and promptly detect and respond to iatrogenic hemorrhagic events. Although at the cost of adding a minor but safe intervention, CTHA-guided liver tumor ablation minimizes complications of the actual ablation procedure, reduces the number of repeat ablations, and improves the oncological outcome of patients with liver malignancies. Therefore, we recommend adopting CTHA as a potential quality-improving guiding method within the (inter)national standards of practice.

15.
Eur Radiol ; 23(3): 827-35, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23014797

RESUMO

OBJECTIVES: To demonstrate the feasibility of MRI-based assessment of the intrahepatic Ho-PLLA-MS biodistribution after radioembolisation in order to estimate the absorbed radiation dose. METHODS: Fifteen patients were treated with holmium-166 ((166)Ho) poly(L-lactic acid)-loaded microspheres (Ho-PLLA-MS, mean 484 mg; range 408-593 mg) in a phase I study. Multi-echo gradient-echo MR images were acquired from which R (2) maps were constructed. The amount of Ho-PLLA-MS in the liver was determined by using the relaxivity r (2) of the Ho-PLLA-MS and compared with the administered amount. Quantitative single photon emission computed tomography (SPECT) was used for comparison with MRI regarding the whole liver absorbed radiation dose. RESULTS: R (2) maps visualised the deposition of Ho-PLLA-MS with great detail. The mean total amount of Ho-PLLA-MS detected in the liver based on MRI was 431 mg (range 236-666 mg) or 89 ± 19 % of the delivered amount (correlation coefficient r = 0.7; P < 0.01). A good correlation was found between the whole liver mean absorbed radiation dose as assessed by MRI and SPECT (correlation coefficient r = 0.927; P < 0.001). CONCLUSION: MRI-based dosimetry for holmium-166 radioembolisation is feasible. Biodistribution is visualised with great detail and quantitative measurements are possible.


Assuntos
Hólmio/análise , Hólmio/uso terapêutico , Neoplasias Hepáticas/química , Neoplasias Hepáticas/radioterapia , Fígado/química , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Microesferas , Pessoa de Meia-Idade , Imagem Molecular/métodos , Especificidade de Órgãos , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/uso terapêutico , Distribuição Tecidual
16.
Lancet Oncol ; 13(10): 1025-34, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22920685

RESUMO

BACKGROUND: The efficacy of radioembolisation for the treatment of liver tumours depends on the selective distribution of radioactive microspheres to tumorous tissue. The distribution of holmium-166 ((166)Ho) poly(L-lactic acid) microspheres can be visualised in vivo by both single-photon-emission CT (SPECT) and MRI. In this phase 1 clinical trial, we aimed to assess the safety and the maximum tolerated radiation dose (MTRD) of (166)Ho-radioembolisation in patients with liver metastases. METHODS: Between Nov 30, 2009, and Sept 19, 2011, patients with unresectable, chemorefractory liver metastases were enrolled in the Holmium Embolization Particles for Arterial Radiotherapy (HEPAR) trial. Patients were treated with intra-arterial (166)Ho-radioembolisation in cohorts of three patients, with escalating aimed whole-liver absorbed doses of 20, 40, 60, and 80 Gy. Cohorts were extended to a maximum of six patients if dose-limiting toxicity occurred. Patients were assigned a dose in the order of study entry, with dose escalation until dose-limiting toxicity was encountered in at least two patients of a dose cohort. Clinical or laboratory toxicities were scored according to the National Cancer Institute's Common Terminology Criteria for Adverse Events version 3.0. The primary endpoint was the MTRD. Analyses were per protocol. This study is registered with ClinicalTrials.gov, number NCT01031784. FINDINGS: 15 patients underwent (166)Ho-radioembolisation at doses of 20 Gy (n=6), 40 Gy (n=3), 60 Gy (n=3), and 80 Gy (n=3). Mean estimated whole-liver absorbed doses were 18 Gy (SD 2) for the 20 Gy cohort, 35 Gy (SD 1) for the 40 Gy cohort, 58 Gy (SD 3) for the 60 Gy cohort, and 73 Gy (SD 4) for the 80 Gy cohort. The 20 Gy cohort was extended to six patients because of the occurrence of dose-limiting toxicity in one patient (pulmonary embolism). In the 80 Gy cohort, dose-limiting toxicity occurred in two patients: grade 4 thrombocytopenia, grade 3 leucopenia, and grade 3 hypoalbuminaemia in one patient, and grade 3 abdominal pain in another patient. The MTRD was identified as 60 Gy. The most frequently encountered laboratory toxicities (including grade 1) were lymphocytopenia, hypoalbuminaemia, raised alkaline phosphatase, raised aspartate aminotransferase, and raised gamma-glutamyltransferase, which were all noted in 12 of 15 patients. Stable disease or partial response regarding target lesions was achieved in 14 of 15 patients (93%, 95% CI 70-99) at 6 weeks and nine of 14 patients (64%, 95% CI 39-84) at 12 weeks after radioembolisation. Compared with baseline, the average global health status and quality of life scale score at 6 weeks after treatment had decreased by 13 points (p=0·053) and by 14 points at 12 weeks (p=0·048). In all patients, technetium-99m ((99m)Tc)-macro-aggregated albumin SPECT, (166)Ho scout dose SPECT, and (166)Ho treatment dose SPECT showed similar patterns of the presence or absence of extrahepatic deposition of activity. INTERPRETATION: (166)Ho-radioembolisation is feasible and safe for the treatment of patients with unresectable and chemorefractory liver metastases and enables image-guided treatment. Clinical (166)Ho-radioembolisation should be done with an aimed whole-liver absorbed dose of 60 Gy.


Assuntos
Embolização Terapêutica/métodos , Hólmio/uso terapêutico , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Compostos Radiofarmacêuticos/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Terapia de Salvação , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único
17.
Cancer Biother Radiopharm ; 38(4): 216-224, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36595357

RESUMO

Background: Immunotherapy in the form of checkpoint inhibitors has changed the treatment paradigm in oncology. Combining selective internal radiation therapy (SIRT) with immunotherapy has been suggested to potentially improve outcomes in hepatocellular carcinoma (HCC) and metastatic colorectal carcinoma (mCRC). In this systematic review, the authors discuss the current developments and available clinical data regarding the combination of immunotherapy and SIRT in treating hepatic malignancies. Methods: PubMed, Embase, and Cochrane library were systematically searched for eligible studies (adhering to Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines). Original patient studies written in English language with patients with HCC or mCRC who were treated with SIRT and immunotherapy were included. Endpoints evaluated included overall survival (OS), progression-free survival (PFS), and objective response rate (ORR). Results: 1038 publications were screened, from which 1034 publications were excluded. Four studies with a total of 87 patients were included in this systematic review, of which two consisted of mCRC and the other two HCC. All four studies showed no increased toxicities of the combination therapy over known data on monotherapy. One mCRC study reported a median OS of 8 months, while the other mCRC study ended due to futility. Both reported an ORR of 0%. The two HCC studies reported a median OS of 16.5 and 16.2 months. Median PFS was 5.6 and 5.7 months. ORR ranged from 31% to 80%. Conclusion: The combination of SIRT and immunotherapy has been studied in four early-phase studies showing a favorable safety profile. Further studies are necessary to understand the possible synergy and possible benefit of combination therapy.


Assuntos
Carcinoma Hepatocelular , Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Terapia Combinada , Neoplasias Colorretais/tratamento farmacológico , Imunoterapia
18.
Cardiovasc Intervent Radiol ; 46(10): 1365-1374, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37704863

RESUMO

PURPOSE: We present a technique that combines Hepatic Arteriography with C-arm CT-Guided Ablation (HepACAGA) to improve tumor visualization, navigation and margin confirmation for percutaneous ablation of liver tumors. MATERIALS AND METHODS: All consecutive patients scheduled for HepACAGA between April 20th, 2021, and November 2nd, 2021, were included in this retrospective, cohort study. HepACAGA was performed in an angiography-suite under general anesthesia. The hepatic artery was catheterized for selective contrast injection. C-arm CT and guidance software were then used to visualize the tumor and the microwave antenna was inserted during apnea. Pre- and post-ablation C-arm CTs were performed and ablation margins assessed. Technical success, antenna placement deviation, number of repositions, tumor recurrence, and safety were evaluated. Technical success was defined as a tumor that was ablated according to the HepACAGA technique. RESULTS: A total of 21 patients (28 tumors) were included. The main tumor type was colorectal cancer liver metastases (11/21, 52%), followed by hepatocellular carcinoma (7/21, 33%), neuroendocrine tumor metastases (1/21, 5%), and other tumor types (2/21, 10%). The technical success rate was 93% (26/28 tumors) with two small hypovascular lesions unable to be identified. A single microwave antenna was used in all patients. The median antenna placement deviation was 1 mm (range 0-6 mm). At a median follow-up time of 16 months (range 5-22 months), there was no tumor recurrence in any patient. Safety analysis showed a complication rate of 5% grade 2 and 5% grade 3. CONCLUSION: HepACAGA was demonstrated to be a safe and effective percutaneous ablation technique, without any local tumor recurrence in this study.

19.
Diagnostics (Basel) ; 13(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38132236

RESUMO

PURPOSE: Trans-arterial radioembolization is a well-studied tumoricidal treatment for liver malignancies; however, consensus and evidence regarding periprocedural prophylactic medication (PPM) are lacking. METHODS: A single-center retrospective analysis from 2014 to 2020 was performed in patients treated with 90Y-glass microspheres for neuroendocrine or colorectal liver metastases. Inclusion criteria were the availability of at least 3 months of clinical, biochemical, and imaging follow-up and post-treatment 90Y-PET/CT imaging for the determination of the whole non-tumorous liver absorbed dose (Dh). Logistic regression models were used to investigate if variables (among which are P/UDCA and Dh) were associated with either clinical toxicity, biochemical toxicity, or hepatotoxicity. Additionally, a structured literature search was performed in November 2022 to identify all publications related to PPM use in radioembolization treatments. RESULTS: Fifty-one patients received P/UDCA as post-treatment medication, while 19 did not. No correlation was found between toxicity and P/UDCA use. Dh was associated with biochemical toxicity (p = 0.05). A literature review resulted in eight relevant articles, including a total of 534 patients, in which no consistent advice regarding PPM was provided. CONCLUSION: In this single-center, retrospective review, P/UDCA use did not reduce liver toxicity in patients with metastatic liver disease. The whole non-tumorous liver-absorbed dose was the only significant factor for hepatotoxicity. No standardized international guidelines or supporting evidence exist for PPM in radioembolization.

20.
J Interv Med ; 6(4): 153-159, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38312126

RESUMO

Liver malignancy, including primary liver cancer and metastatic liver cancer, has become one of the most common causes of cancer-related death worldwide due to the high malignant degree and limited systematic treatment strategy. Radioembolization with yttrium-90 (90Y)-loaded microspheres is a relatively novel technology that has made significant progress in the local treatment of liver malignancy. The different steps in the extensive work-up of radioembolization for patients with an indication for treatment with 90Y microspheres, from patient selection to follow up, both technically and clinically, are discussed in this paper. It describes the application and development of 90Y microspheres in the treatment of liver cancer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA