1.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38519418

RESUMO

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Idoso , Estudos Prospectivos , Fatores de Tempo , Itália , Fatores de Risco , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Intervalo Livre de Progressão
2.
Eur Heart J Suppl ; 25(Suppl C): C253-C257, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125309

RESUMO

Radiofrequency catheter ablation of the cavotricuspid isthmus is the standard treatment for patients suffering from typical atrial flutter. The aim of this study was to test the feasibility of tissue thickness and lesion transmurality measurement by a novel dielectric system. This was a retrospective multicentric non-randomized open-label, single-arm study. The atrial wall thickness was significantly higher close to the tricuspid annulus than close to the inferior vena cava and a trend towards a progressive decrease of atrial wall thickness was observed moving the mapping catheter from the tricuspid valve to the inferior vena cava. The possibility to visualize the tissue thickness could modify the way to deliver radiofrequency energy, allowing a tailored approach in cardiac ablation procedures.

3.
J Cardiovasc Electrophysiol ; 33(7): 1587-1589, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35557022

RESUMO

INTRODUCTION: A new dielectric-based method (KODEX-EPD mapping system, EPD Solutions, a Philips company) for measuring tissue thickness at the catheter-tissue interface has recently been developed. We reported preliminarydata on real-time catheter-based measuring myocardial wall thickness in vivo, during typical atrial flutter radio frequency ablation. METHODS AND RESULTS: The study population consisted of 12 consecutive patients, suffering from symptomatic paroxysmal or persistent cavo-tricuspid isthmus dependent, counter clockwise and clockwise AFL, under going a first catheter ablation between April 2021 and November 2021. The new KODEX-EPD function, Wall Viever, was used to calculate atrialwall thickness. The atrial wall thickness was significantly higher closeto the tricuspid annulus than close to the inferior vena cava (3.6 ± 0.5 mm vs 2.4 ± 0.3 mm, p < .001) and a trend towards a progressive decrease of atrial wall thickness was observed moving the mapping catheter from the tricuspidvalve to the inferior vena cava. CONCLUSIONS: Thenew KODEX-EPD function, Wall Viever, allowed us to assess atrial wall thickness during atrial flutter radio frequency ablation.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Humanos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
4.
J Cardiovasc Electrophysiol ; 33(7): 1414-1424, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35524404

RESUMO

INTRODUCTION: Low-voltage activity beyond pulmonary veins (PVs) may contribute to the failure of ablation of atrial fibrillation (AF) in the long term. We aimed to assess the presence of gaps (PVG) and residual potential (residual antral potential [RAP]) within the antral scar by means of an ultra-high-density mapping (UHDM) system. METHODS: We studied consecutive patients from the CHARISMA registry who were undergoing AF ablation and had complete characterization of residual PV antral activity. The Lumipoint™ (Boston Scientific) map-analysis tool was used sequentially on each PV component. The ablation endpoint was PV isolation (PVI) and electrical quiescence in the antral region. RESULTS: Fifty-eight cases of AF ablation were analyzed. A total of 86 PVGs in 34 (58.6%) patients and 44 RAPs in 34 patients (58.6%) were found. In 16 (27.6%) cases, we found at least one RAP in patients with complete absence of PV conduction. RAPs showed a lower mean voltage than PVG (0.3 ± 0.2 mV vs. 0.7 ± 0.5 mV, p < .0001), whereas the mean number of electrogram peaks was higher (8.4 ± 1.4 vs. 3.2 ± 1.5, p < .0001). The percentage of patients in whom RAPs were detected through Lumipoint™ was higher than through propagation map analysis (58.6% vs. 36.2%, p = .025). Acute procedural success was 100%, with all PVs successfully isolated and RAPs completely abolished in all study patients. During a mean follow-up of 453 ± 133 days, 6 patients (10.3%) suffered an AF/AT recurrence. CONCLUSION: Local vulnerabilities in antral lesion sets were easily discernible by means of the UHDM system in both de novo and redo patients when no PV conduction was present.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
5.
Europace ; 24(2): 234-244, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-34392336

RESUMO

AIMS: We developed and validated an algorithm for prediction of heart failure (HF) hospitalizations using remote monitoring (RM) data transmitted by implanted defibrillators. METHODS AND RESULTS: The SELENE HF study enrolled 918 patients (median age 69 years, 81% men, median ejection fraction 30%) with cardiac resynchronization therapy (44%), dual-chamber (38%), or single-chamber defibrillators with atrial diagnostics (18%). To develop a predictive algorithm, temporal trends of diurnal and nocturnal heart rates, ventricular extrasystoles, atrial tachyarrhythmia burden, heart rate variability, physical activity, and thoracic impedance obtained by daily automatic RM were combined with a baseline risk-stratifier (Seattle HF Model) into one index. The primary endpoint was the first post-implant adjudicated HF hospitalization. After a median follow-up of 22.5 months since enrolment, patients were randomly allocated to the algorithm derivation group (n = 457; 31 endpoints) or algorithm validation group (n = 461; 29 endpoints). In the derivation group, the index showed a C-statistics of 0.89 [95% confidence interval (CI): 0.83-0.95] with 2.73 odds ratio (CI 1.98-3.78) for first HF hospitalization per unitary increase of index value (P < 0.001). In the validation group, sensitivity of predicting primary endpoint was 65.5% (CI 45.7-82.1%), median alerting time 42 days (interquartile range 21-89), and false (or unexplained) alert rate 0.69 (CI 0.64-0.74) [or 0.63 (CI 0.58-0.68)] per patient-year. Without the baseline risk-stratifier, the sensitivity remained 65.5% and the false/unexplained alert rates increased by ≈10% to 0.76/0.71 per patient-year. CONCLUSION: With the developed algorithm, two-thirds of first post-implant HF hospitalizations could be predicted timely with only 0.7 false alerts per patient-year.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Masculino , Volume Sistólico
6.
Heart Vessels ; 37(1): 115-120, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34240266

RESUMO

Pulmonary vein (PV) isolation using cryoballoon (CB) catheter is generally characterized by a high radiation and contrast media exposure. A new dielectric imaging system (KODEX-EPD imaging system) allows pulmonary vein (PV) occlusion assessment without dye use. The purpose of this study was to verify the feasibility of reducing the radiation and dye use during CB ablation in patients with atrial fibrillation (AF) using the new dielectric imaging system. In a retrospective, single center study, we enrolled 34 consecutive patients with paroxysmal AF divided in two groups: 17 patients in Conventional Group underwent the procedure under fluoroscopy guidance before the new system introduction, while 17 patient in KODEX-EPD Group underwent the procedure under fluoroscopy and KODEX-EPD imaging system guidance. There were no differences in any clinical and anatomical characteristics between the two study groups. Overall procedure time was comparable between the two groups (69 [IQR 63-98] min in Conventional Group vs. 65 [IQR 58-74] min in KODEX-EPD Group, p = 0.16), while fluoroscopy time (8 [IQR 5-9] min vs. 11 [IQR 9-12] min, p = 0.014) and dye use (35 [IQR 28-45] ml vs. 70 [IQR 57-83] ml, p < 0.001) were significantly lower in the KODEX-EPD Group. No 30-day complications were observed. At 12-month follow-up 7/37 (19%) patients had an atrial arrhythmias recurrence, without any difference between the two study groups (17.6% vs. 23.5%, p = 0.68). The use of a new dielectric imaging system allowed a significantly reduction in radiation exposure and dye use during CB ablation in patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Meios de Contraste , Fluoroscopia , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
7.
Heart Vessels ; 37(2): 337-346, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34524496

RESUMO

Performing transcatheter aortic valve implantation with high implantation technique, i.e. with an aorto-ventricular ratio > 60/40, reduces the need of permanent pacemaker implantation. Valve calcification and prosthesis oversizing are predictors of permanent pacemaker implantation, but there are no available data on their role when transcatheter aortic valve implantation is performed with an aorto-ventricular ratio > 60/40. The aim of this study was to evaluate the effect of leaflets/annulus calcification and prosthesis oversizing on the incidence of permanent pacemaker implantation after transcatheter aortic valve implantation with a high implantation technique. Transcatheter aortic valve implantation was performed in 48 patients implanting a balloon-expandable transcatheter heart valve with an aorto-ventricular ratio > 60/40. Calcium burden was assessed by preprocedural multidetector computed tomography. An invasive electrophysiological study was performed before and after transcatheter aortic valve implantation. Five patients (10.4%) needed permanent pacemaker implantation. At univariate analysis, baseline right bundle branch block and postprocedural PR, QRS and His-ventricular interval elongation significantly predicted permanent pacemaker implantation (p < 0.05). Receiver-operating characteristic curve analysis showed a correlation between transcatheter heart valve oversizing and permanent pacemaker implantation need, with the best cut-off being 17% (AUC = 0.72, p = 0.033). Linear regression analysis demonstrated that QRS complex elongation was related to total, left and non-coronary leaflet calcification (p < 0.05). This study demonstrates that, when transcatheter aortic valve implantation is performed using a balloon-expandable transcatheter heart valve deployed with an aorto-ventricular ratio > 60/40, the presence of leaflets/annulus calcification or the need to oversize the prosthesis correlate with the occurrence of pathological cardiac conduction delays.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 32(6): 1540-1548, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33851484

RESUMO

BACKGROUND: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. METHODS: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. RESULTS: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p < .0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p < .0001 for LI; 0.73 [0.41-1.25] Ω/s vs. 0.35[0.22-0.59 Ω/s, p < .0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. CONCLUSION: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 32(5): 1296-1304, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33783875

RESUMO

BACKGROUND: No data exist on the ability of the novel Rhythmia 3-D mapping system to minimize fluoroscopy exposure during transcatheter ablation of arrhythmias. We report data on the feasibility and safety of a minimal fluoroscopic approach using this system in supraventricular tachycardia (SVT) procedures. METHODS: Consecutive patients were enrolled in the CHARISMA registry at 12 centers. All right-sided procedures performed with the Rhythmia mapping system were analyzed. The acquired electroanatomic information was used to reconstruct 3-D cardiac geometry; fluoroscopic confirmation was used whenever deemed necessary. RESULTS: Three hundred twenty-five patients (mean age = 56 ± 17 years, 57% male) were included: 152 atrioventricular nodal reentrant tachycardia, 116 atrial flutter, 41 and 16 right-sided accessory pathway and atrial tachycardia, respectively. Overall, 27 481 s of fluoroscopy were used (84.6 ± 224 s per procedure, equivalent effective dose = 1.1 ± 3.7 mSv per patient). One hundred ninety-two procedures (59.1%) were completed without the use of fluoroscopy (zero fluoroscopy, ZF). In multivariate analysis, the presence of a fellow in training (OR = 0.15, 95% CI: 0.05-0.46; p = .0008), radiofrequency application (0.99, 0.99-1.00; p = .0002), and mapping times (0.99, 0.99-1.00; p = .042) were all inversely associated with ZF approach. Acute procedural success was achieved in 97.8% of the cases (98.4 vs. 97% in the ZF vs. non-ZF group; p = .4503). During a mean of 290.7 ± 169.6 days follow-up, no major adverse events were reported, and recurrence of the primary arrhythmia was 2.5% (2.1 vs. 3% in the ZF vs. non-ZF group; p = .7206). CONCLUSIONS: The Rhythmia mapping system permits transcatheter ablation of right-sided SVT with minimal fluoroscopy exposure. Even more, in most cases, the system enables a ZF approach, without affecting safety and efficacy.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34252991

RESUMO

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do Tratamento
11.
Europace ; 23(2): 264-270, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33212484

RESUMO

AIMS: Ablation index (AI) is a marker of lesion quality during catheter ablation that incorporates contact force, time, and power in a weighted formula. This index was originally developed for pulmonary vein isolation as well as other left atrial procedures. The aim of our study is to evaluate the feasibility and efficacy of the AI for the ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL). METHODS AND RESULTS: This prospective multicentre non-randomized study enrolled 412 consecutive patients with typical AFL undergoing AI-guided cavotricuspid isthmus ablation. The procedure was performed targeting an AI of 500 and an inter-lesion distance measurement of ≤6 mm. The primary endpoints were CTI 'first-pass' block and persistent block after a 20-min waiting time. Secondary endpoints included procedural and radiofrequency duration and fluoroscopic time. A total of 412 consecutive patients were enrolled in 31 centres (mean age 64.9 ± 9.8; 72.1% males and 27.7% with structural heart disease). The CTI bidirectional 'first-pass' block was reached in 355 patients (88.3%), whereas CTI block at the end of the waiting time was achieved in 405 patients (98.3%). Mean procedural, radiofrequency, and fluoroscopic time were 56.5 ± 28.1, 7.8 ± 4.8, and 1.9 ± 4.8 min, respectively. There were no major procedural complications. There was no significant inter-operator variability in the ability to achieve any of the primary endpoints. CONCLUSION: AI-guided ablation with an inter-lesion distance ≤6 mm represents an effective, safe, and highly reproducible strategy to achieve bidirectional block in the treatment of typical AFL.


Assuntos
Flutter Atrial , Ablação por Cateter , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
12.
Pacing Clin Electrophysiol ; 44(10): 1717-1723, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34498748

RESUMO

INTRODUCTION: A very high-power short-duration (vHPSD) strategy of radiofrequency (RF) ablation aims to minimize conductive heating and increase resistive heating. This study aimed to clarify the contribution of contact force (CF) and temperature and their interrelationship in making an adequate lesion with the vHPSD catheter. METHODS: We enrolled 46 consecutive patients undergoing first catheter ablation for atrial fibrillation (AF). The vHPSD ablation was performed applying 90 W, for 4 s, with an irrigation of 8 ml/min. During an application, an impedance drop (ID) ≥10 Ω was regarded as an adequate lesion formation. RESULTS: The mean procedural time was 95 ± 15 min. First-pass isolation was reached in 89% of patients and at the end of the procedure all pulmonary veins were isolated. No steam pop nor procedural complication occurred. A total of 3829 qualified RF points were analyzed and the median values of ID, CF and maximum temperature were respectively 10.6 (IQR 8.6-13.1) Ohm, 9 (5.8-13.8) g, 46.8 (44.1-49.8) °C. The mean ID significantly increased in parallel with the increasing CF as well as with the increasing maximum temperature. In the multivariable analysis only the CF and the maximum temperature were independent predictors of ID. From receiver operating characteristic curve analysis, a CF of 8 g and a maximum temperature of 47°C are the optimal cutoff discriminatory value for adequate lesion formation. CONCLUSIONS: The vHPSD ablation is highly effective and safe. The CF and the maximum temperature are independent predictors of adequate lesion formation assessed by means of ID.


Assuntos
Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/métodos , Feminino , Temperatura Alta , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Irrigação Terapêutica
13.
Pacing Clin Electrophysiol ; 44(1): 63-70, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33210304

RESUMO

BACKGROUND: Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. AIM OF THE STUDY: The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF). METHODS: We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX-EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryoballoon (Medtronic Inc.) was verified using the new "occlusion tool" software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV. RESULTS: A total of 105 PV CB occlusion were tested. The new occlusion tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80%, and the negative predictive value was 88.6%. Mean procedure time was 81 ± 17 minutes. Mean fluoroscopy time was 6 ± 2 minutes. No 30-day complications were observed. CONCLUSION: The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Software , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco , Angiografia Coronária , Criocirurgia/instrumentação , Mapeamento Epicárdico , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Sensibilidade e Especificidade
14.
Pacing Clin Electrophysiol ; 44(12): 2031-2040, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34606098

RESUMO

BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros
15.
J Cardiovasc Electrophysiol ; 31(1): 80-88, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31701569

RESUMO

INTRODUCTION: Four generations of the cryoballoon (CB) catheter were retrospectively evaluated in a real-world examination of patients with atrial fibrillation (AF). METHODS AND RESULTS: Four hundred eighty patients (27% female and 60 ± 10 years) suffering from AF, underwent pulmonary vein (PV) ablation with one-of-four generations of the CB catheter. The total cohort was divided into four groups of patients: 120 with first-generation (CB-1); 120 with second-generation (CB-2); 120 with third-generation (CB-3); and 120 with fourth-generation (CB-4). Equal group sizes were achieved by examining the last 120 patients treated in each cohort, attempting to minimize the effect of a learning curve between the generations of CB catheter. Baseline clinical and patient characteristics were similar between the four cohorts, excepting age and the number of tested antiarrhythmic drugs. Procedure, fluoroscopy, and left atrial dwell times were significantly lower in the CB-4 cohort compared to previous generations of the CB catheters, while the acute procedural success rate was comparable across all catheter groups (>99%). Total acute procedural complications were low (2.5%), and acute complications were comparable within the CB-2, CB-3, and CB-4 groups (0.8% reported in each cohort). The rate of time-to-isolation (TTI) visualization increased with later generations of the CB catheters. CONCLUSIONS: The novel CB-4 achieved significantly faster procedural ablation times in comparison to the previous generations, while still maintaining a low rate of acute complications. Also, the rate of TTI visualization was observed to be higher with the CB-4 catheter. Further long-term evaluation is necessary, including an assessment of AF recurrence and PV reconnection(s).


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/fisiopatologia , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 31(9): 2319-2327, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32613661

RESUMO

INTRODUCTION: Recently, a novel technology able to measure local impedance (LI) and tissue characteristics has been made available for clinical use. This analysis explores the relationships among LI and generator impedance (GI) parameters in atrial fibrillation (AF) patients. Characterization of LI among different ablation spots and procedural success were also evaluated. METHODS AND RESULTS: Consecutive patients undergoing AF ablation from the CHARISMA registry at five Italian centers were included. A novel radiofrequency (RF) ablation catheter with a dedicated algorithm (DIRECTSENSE™) was used to measure LI and to guide ablation. The ablation endpoint was pulmonary vein (PV) isolation. We analyzed 2219 ablation spots created around PVs in 46 patients for AF ablation. The mean baseline tissue impedance was 105.8 ± 14 Ω for LI versus 91.8 ± 10 Ω for GI (p < .0001). Baseline impedance was homogenous across the PV sites and proved higher in high-voltage areas than in intermediate- and low-voltage areas and the blood pool (p < .001). Both LI and GI displayed a significant drop after RF delivery, and absolute LI drop values were significantly larger than GI drop values (14 ± 8 vs. 3.7 ± 5 Ω, p < .0001). Every 5-point increment in LI drop was associated with successful ablation (odds ratio = 3.05, 95% confidence interval: 2.3-4.1, p < .0001). Conversely, GI drops were not significantly different comparing successful versus unsuccessful sites (3.7 ± 5 vs. 2.8 ± 4 Ω, p = .1099). No steam pops or major complications occurred during or after the procedures. By the end of the procedures, all PVs had been successfully isolated in all patients. CONCLUSIONS: The magnitude of the LI drop was more closely associated with effective lesion formation than the GI drop.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Humanos , Projetos Piloto , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 31(7): 1694-1701, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32369225

RESUMO

BACKGROUND: Ablation index (AI) is a new lesion quality marker that has been demonstrated to allow a high single-procedure arrhythmia-free survival in single-center studies. This prospective, multi-center study was designed to evaluate the reproducibility of pulmonary vein (PV) isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV isolation and were divided in four study groups according to operator's preference in choosing the ablation catheter (a contact force (ST) or contact force surround flow (STSF) catheter) and the AI setting (330-450 or 380-500 at anterior wall or posterior wall, respectively). RESULTS: At 12 months a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs 83.3%; P = .039). There was no difference in the rate of AF recurrence among the four study groups (4.5% in group ST330-450, 12.2% in group ST 380-500, 14.9% in group STSF330-450, 9.4% in group STSF380-500; P = .083). Recurrence was also similar between patients treated with a ST (8%) or STSF catheter (12.1%; P = .2), and within patients targeting an AI settings of 330 to 450 (10.9%) or 380 to 500 (10.3%; P = .64). In patients with paroxysmal AF, there was no difference (P = .12) in the 1-year freedom from AF recurrence among 14 operators that performed ≥10 ablation procedure. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of 1-year freedom from AF recurrence, irrespective of the ablation catheters, AI settings, and operator.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Reprodutibilidade dos Testes , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 30(9): 1626-1635, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31165517

RESUMO

INTRODUCTION: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter-defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT-D) patients. METHODS AND RESULTS: We analyzed remote-monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT-D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62-77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow-up of 5 years. The 5-year product-limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%-53.9%) in the ICM group and 44.7% (36.9%-53.3%) in the NICM group. In patients with a CRT-D, SVA incidence was 45.7% (37.3%-55.0%) in ICM patients and 49.2% (40.4%-58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70-1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61-1.18, P = .34) in CRT-D patients. SVAs triggered appropriate device therapies with similar incidence in all groups. CONCLUSION: In a large cohort of remotely monitored ICD and CRT-D recipients, SVA incidence did not significantly differ in ICM and NICM patients.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Cardiomiopatias/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/instrumentação , Tecnologia de Sensoriamento Remoto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Causas de Morte , Bases de Dados Factuais , Morte Súbita Cardíaca/epidemiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Valor Preditivo dos Testes , Falha de Prótese , Fatores de Risco , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
19.
Pacing Clin Electrophysiol ; 42(7): 1018-1025, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31050004

RESUMO

BACKGROUND: Various lead designs have been developed to accommodate different coronary sinus anatomies. Our objectives were to compare electrical parameters of straight and spiral left ventricular leads, to evaluate capture thresholds and impedances using different pacing vectors, and to study evolution of thresholds over time. METHODS: The RALLY-X4 study enrolled patients implanted with a lead from the Acuity X4 family (straight, spiral short, or spiral long). Electrical parameters (including capture thresholds from all 17 vectors) were measured at baseline and follow-up. RESULTS: Data from 795 patients who were successfully implanted were analyzed. Straight and spiral leads had similar proportions of patients with thresholds <2.5 V/0.4 ms using the distal electrode (61-65% of patients) or from at least one of the proximal (E2-E4) electrodes (81-83% of patients). Unipolar vectors had significantly lower thresholds and impedances than bipolar vectors, with similar measurements compared to extended bipolar configurations. Capture thresholds increased with more proximal electrodes for all leads. Over a mean follow-up of 1 year, a slight decrease in capture thresholds was observed. CONCLUSION: Straight and spiral quadripolar leads allow to obtain clinically acceptable capture thresholds from at least one of the proximal electrodes in >80% of patients. Pacing vectors significantly affect electrical parameters, with higher thresholds in more proximal electrodes and lower thresholds with unipolar and extended bipolar configurations. Capture thresholds slightly decreased over a mean follow-up of 1 year.


Assuntos
Estimulação Cardíaca Artificial/métodos , Seio Coronário/anatomia & histologia , Eletrodos Implantados , Marca-Passo Artificial , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Vigilância de Produtos Comercializados
20.
Pacing Clin Electrophysiol ; 42(7): 874-881, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31045257

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has been demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multicenter study was designed to evaluate the reproducibility of acute PV isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter (a contact force [ST] or contact force surround flow [STSF] catheter) and the AI setting (330 at posterior and 450 at anterior wall or 380 at posterior and 500 at anterior wall). Radiofrequency was delivered targeting interlesion distance ≤6 mm. RESULTS: The rate of first-pass PV isolation (ST330 90 ± 16%, ST380 87 ± 19%, STSF330 90 ± 17%, STSF380 91 ± 15%, P = .585) was similar among the four study groups, whereas procedure (ST330 129 ± 44 minutes, ST380 144 ± 44 minutes, STSF330 120 ± 72 minutes, STSF380 125 ± 73 minutes, P < .001) and fluoroscopy time (ST330 542 ± 285 seconds, ST380 540 ± 416 seconds, STSF330 257 ± 356 seconds, STSF380 379 ± 454 seconds, P < 0.001) significantly differed. The difference in the rate of first-pass isolation was not statistical different (P = .06) among the 12 operators that performed at least 15 procedures. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion results in high and comparable rate of acute PV isolation among operator performing ablation with different catheters, AI settings, procedure, and fluoroscopy times.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos Testes