Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Lancet Oncol ; 23(7): 910-918, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35714666

RESUMO

BACKGROUND: Men with grade group 2 or 3 prostate cancer are often considered ineligible for active surveillance; some patients with grade group 2 prostate cancer who are managed with active surveillance will have early disease progression requiring radical therapy. This study aimed to investigate whether MRI-guided focused ultrasound focal therapy can safely reduce treatment burden for patients with localised grade group 2 or 3 intermediate-risk prostate cancer. METHODS: In this single-arm, multicentre, phase 2b study conducted at eight health-care centres in the USA, we recruited men aged 50 years and older with unilateral, MRI-visible, primary, intermediate-risk, previously untreated prostate adenocarcinoma (prostate-specific antigen ≤20 ng/mL, grade group 2 or 3; tumour classification ≤T2) confirmed on combined biopsy (combining MRI-targeted and systematic biopsies). MRI-guided focused ultrasound energy, sequentially titrated to temperatures sufficient for tissue ablation (about 60-70°C), was delivered to the index lesion and a planned margin of 5 mm or more of normal tissue, using real-time magnetic resonance thermometry for intraoperative monitoring. Co-primary outcomes were oncological outcomes (absence of grade group 2 and higher cancer in the treated area at 6-month and 24-month combined biopsy; when 24-month biopsy data were not available and grade group 2 or higher cancer had occurred in the treated area at 6 months, the 6-month biopsy results were included in the final analysis) and safety (adverse events up to 24 months) in all patients enrolled in the study. This study is registered with ClinicalTrials.gov, NCT01657942, and is no longer recruiting. FINDINGS: Between May 4, 2017, and Dec 21, 2018, we assessed 194 patients for eligibility and treated 101 patients with MRI-guided focused ultrasound. Median age was 63 years (IQR 58-67) and median concentration of prostate-specific antigen was 5·7 ng/mL (IQR 4·2-7·5). Most cancers were grade group 2 (79 [78%] of 101). At 24 months, 78 (88% [95% CI 79-94]) of 89 men had no evidence of grade group 2 or higher prostate cancer in the treated area. No grade 4 or grade 5 treatment-related adverse events were reported, and only one grade 3 adverse event (urinary tract infection) was reported. There were no treatment-related deaths. INTERPRETATION: 24-month biopsy outcomes show that MRI-guided focused ultrasound focal therapy is safe and effectively treats grade group 2 or 3 prostate cancer. These results support focal therapy for select patients and its use in comparative trials to determine if a tissue-preserving approach is effective in delaying or eliminating the need for radical whole-gland treatment in the long term. FUNDING: Insightec and the National Cancer Institute.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Idoso , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/terapia
2.
Cancer ; 128(18): 3287-3296, 2022 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-35819253

RESUMO

BACKGROUND: Most Prostate Imaging-Reporting and Data System (PI-RADS) 3 lesions do not contain clinically significant prostate cancer (CSPCa; grade group ≥2). This study was aimed at identifying clinical and magnetic resonance imaging (MRI)-derived risk fac- tors that predict CSPCa in men with PI-RADS 3 lesions. METHODS: This study analyzed the detection of CSPCa in men who underwent MRI-targeted biopsy for PI-RADS 3 lesions. Multivariable logistic regression models with goodness-of-fit testing were used to identify variables associated with CSPCa. Receiver operating curves and decision curve analyses were used to estimate the clinical utility of a predictive model. RESULTS: Of the 1784 men reviewed, 1537 were included in the training cohort, and 247 were included in the validation cohort. The 309 men with CSPCa (17.3%) were older, had a higher prostate-specific antigen (PSA) density, and had a greater likelihood of an anteriorly located lesion than men without CSPCa (p < .01). Multivariable analysis revealed that PSA density (odds ratio [OR], 1.36; 95% confidence interval [CI], 1.05-1.85; p < .01), age (OR, 1.05; 95% CI, 1.02-1.07; p < .01), and a biopsy-naive status (OR, 1.83; 95% CI, 1.38-2.44) were independently associated with CSPCa. A prior negative biopsy was negatively associated (OR, 0.35; 95% CI, 0.24-0.50; p < .01). The application of the model to the validation cohort resulted in an area under the curve of 0.78. A predicted risk threshold of 12% could have prevented 25% of biopsies while detecting almost 95% of CSPCas with a sensitivity of 94% and a specificity of 34%. CONCLUSIONS: For PI-RADS 3 lesions, an elevated PSA density, older age, and a biopsy-naive status were associated with CSPCa, whereas a prior negative biopsy was negatively associated. A predictive model could prevent PI-RADS 3 biopsies while missing few CSPCas. LAY SUMMARY: Among men with an equivocal lesion (Prostate Imaging-Reporting and Data System 3) on multiparametric magnetic resonance imaging (mpMRI), those who are older, those who have a higher prostate-specific antigen density, and those who have never had a biopsy before are at higher risk for having clinically significant prostate cancer (CSPCa) on subsequent biopsy. However, men with at least one negative biopsy have a lower risk of CSPCa. A new predictive model can greatly reduce the need to biopsy equivocal lesions noted on mpMRI while missing only a few cases of CSPCa.


Assuntos
Neoplasias da Próstata , Biópsia , Humanos , Imageamento por Ressonância Magnética , Masculino , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco
3.
Magn Reson Med ; 86(1): 308-319, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33608954

RESUMO

PURPOSE: Provide a direct, non-invasive diagnostic measure of microscopic tissue texture in the size scale between tens of microns and the much larger scale measurable by clinical imaging. This paper presents a method and data demonstrating the ability to measure these microscopic pathologic tissue textures (histology) in the presence of subject motion in an MR scanner. This size range is vital to diagnosing a wide range of diseases. THEORY/METHODS: MR micro-Texture (MRµT) resolves these textures by a combination of measuring a targeted set of k-values to characterize texture-as in diffraction analysis of materials, performing a selective internal excitation to isolate a volume of interest (VOI), applying a high k-value phase encode to the excited spins in the VOI, and acquiring each individual k-value data point in a single excitation-providing motion immunity and extended acquisition time for maximizing signal-to-noise ratio. Additional k-value measurements from the same tissue can be made to characterize the tissue texture in the VOI-there is no need for these additional measurements to be spatially coherent as there is no image to be reconstructed. This method was applied to phantoms and tissue specimens including human prostate tissue. RESULTS: Data demonstrating resolution <50 µm, motion immunity, and clearly differentiating between normal and cancerous tissue textures are presented. CONCLUSION: The data reveal textural differences not resolvable by standard MR imaging. As MRµT is a pulse sequence, it is directly translatable to MRI scanners currently in clinical practice to meet the need for further improvement in cancer imaging.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Masculino , Movimento (Física) , Imagens de Fantasmas , Razão Sinal-Ruído
4.
J Urol ; 206(3): 604-612, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33878887

RESUMO

PURPOSE: Targeted biopsy improves prostate cancer diagnosis. Accurate prostate segmentation on magnetic resonance imaging (MRI) is critical for accurate biopsy. Manual gland segmentation is tedious and time-consuming. We sought to develop a deep learning model to rapidly and accurately segment the prostate on MRI and to implement it as part of routine magnetic resonance-ultrasound fusion biopsy in the clinic. MATERIALS AND METHODS: A total of 905 subjects underwent multiparametric MRI at 29 institutions, followed by magnetic resonance-ultrasound fusion biopsy at 1 institution. A urologic oncology expert segmented the prostate on axial T2-weighted MRI scans. We trained a deep learning model, ProGNet, on 805 cases. We retrospectively tested ProGNet on 100 independent internal and 56 external cases. We prospectively implemented ProGNet as part of the fusion biopsy procedure for 11 patients. We compared ProGNet performance to 2 deep learning networks (U-Net and holistically-nested edge detector) and radiology technicians. The Dice similarity coefficient (DSC) was used to measure overlap with expert segmentations. DSCs were compared using paired t-tests. RESULTS: ProGNet (DSC=0.92) outperformed U-Net (DSC=0.85, p <0.0001), holistically-nested edge detector (DSC=0.80, p <0.0001), and radiology technicians (DSC=0.89, p <0.0001) in the retrospective internal test set. In the prospective cohort, ProGNet (DSC=0.93) outperformed radiology technicians (DSC=0.90, p <0.0001). ProGNet took just 35 seconds per case (vs 10 minutes for radiology technicians) to yield a clinically utilizable segmentation file. CONCLUSIONS: This is the first study to employ a deep learning model for prostate gland segmentation for targeted biopsy in routine urological clinical practice, while reporting results and releasing the code online. Prospective and retrospective evaluations revealed increased speed and accuracy.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico , Conjuntos de Dados como Assunto , Estudos de Viabilidade , Humanos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista , Masculino , Imagem Multimodal/métodos , Imageamento por Ressonância Magnética Multiparamétrica , Estudo de Prova de Conceito , Estudos Prospectivos , Próstata/patologia , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Fatores de Tempo , Ultrassonografia de Intervenção/métodos
5.
Int J Cancer ; 147(1): 256-265, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31863456

RESUMO

Clear cell renal cell carcinoma (ccRCC) is the most common and lethal subtype of kidney cancer. Intraoperative frozen section (IFS) analysis is used to confirm the diagnosis during partial nephrectomy. However, surgical margin evaluation using IFS analysis is time consuming and unreliable, leading to relatively low utilization. In our study, we demonstrated the use of desorption electrospray ionization mass spectrometry imaging (DESI-MSI) as a molecular diagnostic and prognostic tool for ccRCC. DESI-MSI was conducted on fresh-frozen 23 normal tumor paired nephrectomy specimens of ccRCC. An independent validation cohort of 17 normal tumor pairs was analyzed. DESI-MSI provides two-dimensional molecular images of tissues with mass spectra representing small metabolites, fatty acids and lipids. These tissues were subjected to histopathologic evaluation. A set of metabolites that distinguish ccRCC from normal kidney were identified by performing least absolute shrinkage and selection operator (Lasso) and log-ratio Lasso analysis. Lasso analysis with leave-one-patient-out cross-validation selected 57 peaks from over 27,000 metabolic features across 37,608 pixels obtained using DESI-MSI of ccRCC and normal tissues. Baseline Lasso of metabolites predicted the class of each tissue to be normal or cancerous tissue with an accuracy of 94 and 76%, respectively. Combining the baseline Lasso with the ratio of glucose to arachidonic acid could potentially reduce scan time and improve accuracy to identify normal (82%) and ccRCC (88%) tissue. DESI-MSI allows rapid detection of metabolites associated with normal and ccRCC with high accuracy. As this technology advances, it could be used for rapid intraoperative assessment of surgical margin status.


Assuntos
Carcinoma de Células Renais/metabolismo , Neoplasias Renais/metabolismo , Espectrometria de Massas por Ionização por Electrospray/métodos , Carcinoma de Células Renais/diagnóstico por imagem , Secções Congeladas , Humanos , Neoplasias Renais/diagnóstico por imagem
6.
J Urol ; 203(3): 530-536, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31502942

RESUMO

PURPOSE: Asian American men have distinctly different prostate cancer epidemiology than other men. To our knowledge the role of multiparametric magnetic resonance imaging and targeted biopsy for elevated prostate specific antigen in this population has not been assessed. We sought to define imaging and targeted biopsy outcomes in Asian American men compared to other men. MATERIALS AND METHODS: We accrued a multicenter, prospective cohort of men who underwent magnetic resonance imaging targeted and systematic biopsy for elevated prostate specific antigen. The outcome of interest was a diagnosis of clinically significant prostate cancer (Gleason Grade Group 2 or greater) stratified by the PI-RADS™ (Prostate Imaging-Reporting and Data System) score and a history of negative biopsy. Multivariable logistic regression was used to assess the effect of Asian American race on cancer detection. RESULTS: Of the 2,571 men 275 (11%) were Asian American. Clinically significant prostate cancer was detected in 37% of Asian American men compared to 48% of men of other races (p <0.001). Asian American men were also less likely to be diagnosed with Grade Group 1 cancer (12% vs 18%, p=0.007). Additionally, there was significantly lower detection of significant cancer using PI-RADS 3 in Asian American men vs men of other races (12% vs 21%, p=0.032). On adjusted analysis Asian American men were less likely to be diagnosed with significant cancer (OR 0.57, 95% CI 0.42-0.79, p <0.001) and Grade Group 1 cancer (OR 0.57, 95% CI 0.38-0.84, p=0.005) than nonAsian men. CONCLUSIONS: Asian American men are less likely to be diagnosed with clinically significant prostate cancer on targeted biopsy, illustrating the different performance of PI-RADS in this population. Conventional risk assessment tools should be modified when selecting Asian American men for biopsy.


Assuntos
Asiático , Biópsia Guiada por Imagem/métodos , Imagem Multimodal , Neoplasias da Próstata/etnologia , Neoplasias da Próstata/patologia , Idoso , Biomarcadores Tumorais/sangue , Humanos , Imagem por Ressonância Magnética Intervencionista , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Antígeno Prostático Específico/sangue , Estudos Retrospectivos , Ultrassonografia de Intervenção
7.
Proc Natl Acad Sci U S A ; 114(13): 3334-3339, 2017 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-28292895

RESUMO

Accurate identification of prostate cancer in frozen sections at the time of surgery can be challenging, limiting the surgeon's ability to best determine resection margins during prostatectomy. We performed desorption electrospray ionization mass spectrometry imaging (DESI-MSI) on 54 banked human cancerous and normal prostate tissue specimens to investigate the spatial distribution of a wide variety of small metabolites, carbohydrates, and lipids. In contrast to several previous studies, our method included Krebs cycle intermediates (m/z <200), which we found to be highly informative in distinguishing cancer from benign tissue. Malignant prostate cells showed marked metabolic derangements compared with their benign counterparts. Using the "Least absolute shrinkage and selection operator" (Lasso), we analyzed all metabolites from the DESI-MS data and identified parsimonious sets of metabolic profiles for distinguishing between cancer and normal tissue. In an independent set of samples, we could use these models to classify prostate cancer from benign specimens with nearly 90% accuracy per patient. Based on previous work in prostate cancer showing that glucose levels are high while citrate is low, we found that measurement of the glucose/citrate ion signal ratio accurately predicted cancer when this ratio exceeds 1.0 and normal prostate when the ratio is less than 0.5. After brief tissue preparation, the glucose/citrate ratio can be recorded on a tissue sample in 1 min or less, which is in sharp contrast to the 20 min or more required by histopathological examination of frozen tissue specimens.


Assuntos
Lipídeos/química , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/metabolismo , Espectrometria de Massas por Ionização por Electrospray/métodos , Ciclo do Ácido Cítrico , Humanos , Metabolismo dos Lipídeos , Masculino , Neoplasias da Próstata/química , Neoplasias da Próstata/patologia
8.
J Am Soc Nephrol ; 29(1): 207-216, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29018140

RESUMO

The comparative effectiveness of partial nephrectomy versus radical nephrectomy to preserve kidney function has not been well established. We determined the risk of clinically significant (stage 4 and higher) CKD after radical or partial nephrectomy among veterans treated for kidney cancer in the Veterans Health Administration (2001-2013). Among patients with preoperative eGFR≥30 ml/min per 1.73 m2, the incidence of CKD stage 4 or higher after radical (n=9759) or partial nephrectomy (n=4370) was 7.9% overall. The median time to stage 4 or higher CKD after surgery was 5 months, after which few patients progressed. In propensity score-matched cohorts, partial nephrectomy associated with a significantly lower relative risk of incident CKD stage 4 or higher (hazard ratio, 0.34; 95% confidence interval [95% CI], 0.26 to 0.43, versus radical nephrectomy). In a parallel analysis of patients with normal or near-normal preoperative kidney function (eGFR≥60 ml/min per 1.73 m2), partial nephrectomy was also associated with a significantly lower relative risk of incident CKD stage 3b or higher (hazard ratio, 0.15; 95% CI, 0.11 to 0.19, versus radical nephrectomy) in propensity score-matched cohorts. Competing risk regression models produced consistent results. Finally, patients treated with a partial nephrectomy had reduced risk of mortality (hazard ratio, 0.55; 95% CI, 0.49 to 0.62). In conclusion, compared with radical nephrectomy, partial nephrectomy was associated with a marked reduction in the incidence of clinically significant CKD and with enhanced survival. Postoperative decline in kidney function occurred mainly in the first year after surgery and appeared stable over time.


Assuntos
Neoplasias Renais/cirurgia , Nefrectomia/métodos , Insuficiência Renal Crônica/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Taxa de Filtração Glomerular , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Pontuação de Propensão , Insuficiência Renal Crônica/etiologia , Insuficiência Renal Crônica/fisiopatologia , Medição de Risco , Taxa de Sobrevida , Fatores de Tempo
9.
Radiology ; 288(2): 495-505, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29786490

RESUMO

Purpose To report the results of dual-time-point gallium 68 (68Ga) prostate-specific membrane antigen (PSMA)-11 positron emission tomography (PET)/magnetic resonance (MR) imaging prior to prostatectomy in patients with intermediate- or high-risk cancer. Materials and Methods Thirty-three men who underwent conventional imaging as clinically indicated and who were scheduled for radical prostatectomy with pelvic lymph node dissection were recruited for this study. A mean dose of 4.1 mCi ± 0.7 (151.7 MBq ± 25.9) of 68Ga-PSMA-11 was administered. Whole-body images were acquired starting 41-61 minutes after injection by using a GE SIGNA PET/MR imaging unit, followed by an additional pelvic PET/MR imaging acquisition at 87-125 minutes after injection. PET/MR imaging findings were compared with findings at multiparametric MR imaging (including diffusion-weighted imaging, T2-weighted imaging, and dynamic contrast material-enhanced imaging) and were correlated with results of final whole-mount pathologic examination and pelvic nodal dissection to yield sensitivity and specificity. Dual-time-point metabolic parameters (eg, maximum standardized uptake value [SUVmax]) were compared by using a paired t test and were correlated with clinical and histopathologic variables including prostate-specific antigen level, Gleason score, and tumor volume. Results Prostate cancer was seen at 68Ga-PSMA-11 PET in all 33 patients, whereas multiparametric MR imaging depicted Prostate Imaging Reporting and Data System (PI-RADS) 4 or 5 lesions in 26 patients and PI-RADS 3 lesions in four patients. Focal uptake was seen in the pelvic lymph nodes in five patients. Pathologic examination confirmed prostate cancer in all patients, as well as nodal metastasis in three. All patients with normal pelvic nodes in PET/MR imaging had no metastases at pathologic examination. The accumulation of 68Ga-PSMA-11 increased at later acquisition times, with higher mean SUVmax (15.3 vs 12.3, P < .001). One additional prostate cancer was identified only at delayed imaging. Conclusion This study found that 68Ga-PSMA-11 PET can be used to identify prostate cancer, while MR imaging provides detailed anatomic guidance. Hence, 68Ga-PSMA-11 PET/MR imaging provides valuable diagnostic information and may inform the need for and extent of pelvic node dissection.


Assuntos
Ácido Edético/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico por imagem , Compostos Radiofarmacêuticos , Idoso , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem
10.
J Urol ; 200(3): 541-548, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29630980

RESUMO

PURPOSE: We sought to characterize the effects of prostate specific antigen registry errors on clinical research by comparing cohorts based on cancer registry prostate specific antigen values with those based directly on results in the electronic health record. MATERIALS AND METHODS: We defined sample cohorts of men with prostate cancer using data from the Veterans Health Administration, including those with a prostate specific antigen value less than 4.0, 4.0 to 10.0, 10.0 to 20.0 and 20.0 to 98.0 ng/ml, respectively. We compared the composition of each cohort and overall patient survival when using prostate specific antigen values from the Veteran Affairs Central Cancer Registry vs the gold standard electronic health record laboratory file results. RESULTS: There was limited agreement among cohorts when defined by cancer registry prostate specific antigen values vs the laboratory file of the electronic health record. The least agreement of 58% was seen in patients with prostate specific antigen less than 4.0 ng/ml and greatest agreement of 89% was noted among patients with prostate specific antigen between 4.0 and 10.0 ng/ml. In each cohort patients assigned to a cohort based only on the cancer registry prostate specific antigen value had significantly different overall survival when compared with patients assigned based on registry and laboratory file prostate specific antigen values. CONCLUSIONS: Cohorts based exclusively on cancer registry prostate specific antigen values may have high rates of misclassification that can introduce concerning differences in key characteristics and result in measurable differences in clinical outcomes.


Assuntos
Confiabilidade dos Dados , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Sistema de Registros , Projetos de Pesquisa , Idoso , Pesquisa Biomédica , Humanos , Masculino , Estados Unidos , United States Department of Veterans Affairs
11.
J Vasc Interv Radiol ; 29(6): 893-898.e4, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29628296

RESUMO

PURPOSE: To compare the intensity of muscle contractions in irreversible electroporation (IRE) treatments when traditional IRE and high-frequency IRE (H-FIRE) waveforms are used in combination with a single applicator and distal grounding pad (A+GP) configuration. MATERIALS AND METHODS: An ex vivo in situ porcine model was used to compare muscle contractions induced by traditional monopolar IRE waveforms vs high-frequency bipolar IRE waveforms. Pulses with voltages between 200 and 5,000 V were investigated, and muscle contractions were recorded by using accelerometers placed on or near the applicators. RESULTS: H-FIRE waveforms reduced the intensity of muscle contractions in comparison with traditional monopolar IRE pulses. A high-energy burst of 2-µs alternating-polarity pulses energized for 200 µs at 4,500 V produced less intense muscle contractions than traditional IRE pulses, which were 25-100 µs in duration at 3,000 V. CONCLUSIONS: H-FIRE appears to be an effective technique to mitigate the muscle contractions associated with traditional IRE pulses. This may enable the use of voltages greater than 3,000 V necessary for the creation of large ablations in vivo.


Assuntos
Eletroporação/métodos , Fígado/patologia , Contração Muscular/fisiologia , Animais , Feminino , Técnicas In Vitro , Modelos Animais , Suínos
13.
J Urol ; 196(6): 1613-1618, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27320841

RESUMO

PURPOSE: After an initial negative biopsy there is an ongoing need for strategies to improve patient selection for repeat biopsy as well as the diagnostic yield from repeat biopsies. MATERIALS AND METHODS: As a collaborative initiative of the AUA (American Urological Association) and SAR (Society of Abdominal Radiology) Prostate Cancer Disease Focused Panel, an expert panel of urologists and radiologists conducted a literature review and formed consensus statements regarding the role of prostate magnetic resonance imaging and magnetic resonance imaging targeted biopsy in patients with a negative biopsy, which are summarized in this review. RESULTS: The panel recognizes that many options exist for men with a previously negative biopsy. If a biopsy is recommended, prostate magnetic resonance imaging and subsequent magnetic resonance imaging targeted cores appear to facilitate the detection of clinically significant disease over standardized repeat biopsy. Thus, when high quality prostate magnetic resonance imaging is available, it should be strongly considered for any patient with a prior negative biopsy who has persistent clinical suspicion for prostate cancer and who is under evaluation for a possible repeat biopsy. The decision of whether to perform magnetic resonance imaging in this setting must also take into account the results of any other biomarkers and the cost of the examination, as well as the availability of high quality prostate magnetic resonance imaging interpretation. If magnetic resonance imaging is done, it should be performed, interpreted and reported in accordance with PI-RADS version 2 (v2) guidelines. Experience of the reporting radiologist and biopsy operator are required to achieve optimal results and practices integrating prostate magnetic resonance imaging into patient care are advised to implement quality assurance programs to monitor targeted biopsy results. CONCLUSIONS: Patients receiving a PI-RADS assessment category of 3 to 5 warrant repeat biopsy with image guided targeting. While transrectal ultrasound guided magnetic resonance imaging fusion or in-bore magnetic resonance imaging targeting may be valuable for more reliable targeting, especially for lesions that are small or in difficult locations, in the absence of such targeting technologies cognitive (visual) targeting remains a reasonable approach in skilled hands. At least 2 targeted cores should be obtained from each magnetic resonance imaging defined target. Given the number of studies showing a proportion of missed clinically significant cancers by magnetic resonance imaging targeted cores, a case specific decision must be made whether to also perform concurrent systematic sampling. However, performing solely targeted biopsy should only be considered once quality assurance efforts have validated the performance of prostate magnetic resonance imaging interpretations with results consistent with the published literature. In patients with negative or low suspicion magnetic resonance imaging (PI-RADS assessment category of 1 or 2, respectively), other ancillary markers (ie PSA, PSAD, PSAV, PCA3, PHI, 4K) may be of value in identifying patients warranting repeat systematic biopsy, although further data are needed on this topic. If a repeat biopsy is deferred on the basis of magnetic resonance imaging findings, then continued clinical and laboratory followup is advised and consideration should be given to incorporating repeat magnetic resonance imaging in this diagnostic surveillance regimen.


Assuntos
Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Imageamento por Ressonância Magnética/métodos , Próstata/patologia , Neoplasias da Próstata/patologia , Consenso , Humanos , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem
14.
J Vasc Interv Radiol ; 27(9): 1432-1440.e3, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27478129

RESUMO

PURPOSE: To mathematically model and test ex vivo a modified technique of irreversible electroporation (IRE) to produce large spherical ablations by using a single probe. MATERIALS AND METHODS: Computed simulations were performed by using varying voltages, electrode exposure lengths, and tissue types. A vegetable (potato) tissue model was then used to compare ablations created by conventional and high-frequency IRE protocols by using 2 probe configurations: a single probe with two collinear electrodes (2EP) or a single electrode configured with a grounding pad (P+GP). The new P+GP electrode configuration was evaluated in ex vivo liver tissue. RESULTS: The P+GP configuration produced more spherical ablation volumes than the 2EP configuration in computed simulations and tissue models. In prostate tissue, computed simulations predicted ablation volumes at 3,000 V of 1.6 cm(3) for the P+GP configurations, compared with 0.94 cm(3) for the 2EP configuration; in liver tissue, the predicted ablation volumes were 4.7 times larger than those in the prostate. Vegetable model studies verify that the P+GP configuration produces larger and more spherical ablations than those produced by the 2EP. High-frequency IRE treatment of ex vivo liver with the P+GP configuration created a 2.84 × 2.21-cm ablation zone. CONCLUSIONS: Computer modeling showed that P+GP configuration for IRE procedures yields ablations that are larger than the 2EP configuration, creating substantial ablation zones with a single electrode placement. When tested in tissue models and an ex vivo liver model, the P+GP configuration created ablation zones that appear to be of clinically relevant size and shape.


Assuntos
Técnicas de Ablação/instrumentação , Eletrodos , Eletroporação/instrumentação , Fígado/cirurgia , Animais , Simulação por Computador , Desenho de Equipamento , Análise de Elementos Finitos , Técnicas In Vitro , Fígado/patologia , Teste de Materiais , Análise Numérica Assistida por Computador , Suínos
16.
J Urol ; 194(3): 626-34, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25849602

RESUMO

PURPOSE: Gleason 6 (3+3) is the most commonly diagnosed prostate cancer among men with prostate specific antigen screening, the most histologically well differentiated and is associated with the most favorable prognosis. Despite its prevalence, considerable debate exists regarding the genetic features, clinical significance, natural history, metastatic potential and optimal management. MATERIALS AND METHODS: Members of the Young Urologic Oncologists in the Society of Urologic Oncology cooperated in a comprehensive search of the peer reviewed English medical literature on Gleason 6 prostate cancer, specifically focusing on the history of the Gleason scoring system, histological features, clinical characteristics, practice patterns and outcomes. RESULTS: The Gleason scoring system was devised in the early 1960s, widely adopted by 1987 and revised in 2005 with a more restrictive definition of Gleason 6 disease. There is near consensus that Gleason 6 meets pathological definitions of cancer, but controversy about whether it meets commonly accepted molecular and genetic criteria of cancer. Multiple clinical series suggest that the metastatic potential of contemporary Gleason 6 disease is negligible but not zero. Population based studies in the U.S. suggest that more than 90% of men newly diagnosed with prostate cancer undergo treatment and are exposed to the risk of morbidity for a cancer unlikely to cause symptoms or decrease life expectancy. Efforts have been proposed to minimize the number of men diagnosed with or treated for Gleason 6 prostate cancer. These include modifications to prostate specific antigen based screening strategies such as targeting high risk populations, decreasing the frequency of screening, recommending screening cessation, incorporating remaining life expectancy estimates, using shared decision making and novel biomarkers, and eliminating prostate specific antigen screening entirely. Large nonrandomized and randomized studies have shown that active surveillance is an effective management strategy for men with Gleason 6 disease. Active surveillance dramatically reduces the number of men undergoing treatment without apparent compromise of cancer related outcomes. CONCLUSIONS: The definition and clinical relevance of Gleason 6 prostate cancer have changed substantially since its introduction nearly 50 years ago. A high proportion of screen detected cancers are Gleason 6 and the metastatic potential is negligible. Dramatically reducing the diagnosis and treatment of Gleason 6 disease is likely to have a favorable impact on the net benefit of prostate cancer screening.


Assuntos
Neoplasias da Próstata/patologia , Detecção Precoce de Câncer , Humanos , Masculino , Gradação de Tumores/normas , Prognóstico , Neoplasias da Próstata/epidemiologia , Neoplasias da Próstata/terapia , Medição de Risco , Conduta Expectante
17.
J Urol ; 192(5): 1367-73, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24793118

RESUMO

PURPOSE: We explored the impact of magnetic resonance imaging-ultrasound fusion prostate biopsy on the prediction of final surgical pathology. MATERIALS AND METHODS: A total of 54 consecutive men undergoing radical prostatectomy at UCLA after fusion biopsy were included in this prospective, institutional review board approved pilot study. Using magnetic resonance imaging-ultrasound fusion, tissue was obtained from a 12-point systematic grid (mapping biopsy) and from regions of interest detected by multiparametric magnetic resonance imaging (targeted biopsy). A single radiologist read all magnetic resonance imaging, and a single pathologist independently rereviewed all biopsy and whole mount pathology, blinded to prior interpretation and matched specimen. Gleason score concordance between biopsy and prostatectomy was the primary end point. RESULTS: Mean patient age was 62 years and median prostate specific antigen was 6.2 ng/ml. Final Gleason score at prostatectomy was 6 (13%), 7 (70%) and 8-9 (17%). A tertiary pattern was detected in 17 (31%) men. Of 45 high suspicion (image grade 4-5) magnetic resonance imaging targets 32 (71%) contained prostate cancer. The per core cancer detection rate was 20% by systematic mapping biopsy and 42% by targeted biopsy. The highest Gleason pattern at prostatectomy was detected by systematic mapping biopsy in 54%, targeted biopsy in 54% and a combination in 81% of cases. Overall 17% of cases were upgraded from fusion biopsy to final pathology and 1 (2%) was downgraded. The combination of targeted biopsy and systematic mapping biopsy was needed to obtain the best predictive accuracy. CONCLUSIONS: In this pilot study magnetic resonance imaging-ultrasound fusion biopsy allowed for the prediction of final prostate pathology with greater accuracy than that reported previously using conventional methods (81% vs 40% to 65%). If confirmed, these results will have important clinical implications.


Assuntos
Biópsia por Agulha/métodos , Endossonografia/métodos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Estadiamento de Neoplasias , Neoplasias da Próstata/diagnóstico , Idoso , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Prospectivos , Prostatectomia , Neoplasias da Próstata/cirurgia , Reto , Reprodutibilidade dos Testes
18.
Clin Genitourin Cancer ; 22(4): 102113, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38845330

RESUMO

INTRODUCTION: Food and Drug Administration must make decisions about emerging high intensity focused ultrasound (HIFU) devices that may lack relevant clinical oncologic data but present with known side effects. This study aims to capture patients' perspective by quantifying their preferences regarding the available benefit and important side effects associated with HIFU for localized prostate cancer. MATERIALS AND METHODS: Preferences for HIFU outcomes were examined using a discrete choice experiment survey. Participants were asked to choose a preferred treatment option in 9 choice questions. Each included a pair of hypothetical treatment profiles that have similar attributes/outcomes with varying levels. Outcomes included prostate biopsy outcome and treatment-related risks of erectile dysfunction (ED) and urinary incontinence (UI). We calculated the maximum risk of side effect patients were willing to tolerate in exchange for increased benefit. Preferences were further explored via clinical and demographic data. RESULTS: About 223 subjects with a mean age of 64.8 years completed the survey. Respondents were willing to accept a 1.51%-point increase in new ED risk for a 1%-point increase in favorable biopsy outcome. They were also willing to accept a 0.93%-point increase in new UI risk for a 1%-point increase in biopsy outcome. Subjects who perceived their cancer to be more aggressive had higher risk tolerance for UI. Younger men were willing to tolerate less ED risk than older men. Respondents with greater than college level of education had a lower risk tolerance for ED or UI. CONCLUSIONS: Results may inform development and regulatory evaluation for future HIFU ablation devices by providing supplemental information from the patient perspective.


Assuntos
Preferência do Paciente , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Pessoa de Meia-Idade , Idoso , Inquéritos e Questionários , Disfunção Erétil/etiologia , Incontinência Urinária/etiologia , Medição de Risco , Ultrassom Focalizado Transretal de Alta Intensidade/métodos , Resultado do Tratamento , Próstata/patologia , Próstata/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos
19.
Comput Biol Med ; 173: 108318, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522253

RESUMO

Image registration can map the ground truth extent of prostate cancer from histopathology images onto MRI, facilitating the development of machine learning methods for early prostate cancer detection. Here, we present RAdiology PatHology Image Alignment (RAPHIA), an end-to-end pipeline for efficient and accurate registration of MRI and histopathology images. RAPHIA automates several time-consuming manual steps in existing approaches including prostate segmentation, estimation of the rotation angle and horizontal flipping in histopathology images, and estimation of MRI-histopathology slice correspondences. By utilizing deep learning registration networks, RAPHIA substantially reduces computational time. Furthermore, RAPHIA obviates the need for a multimodal image similarity metric by transferring histopathology image representations to MRI image representations and vice versa. With the assistance of RAPHIA, novice users achieved expert-level performance, and their mean error in estimating histopathology rotation angle was reduced by 51% (12 degrees vs 8 degrees), their mean accuracy of estimating histopathology flipping was increased by 5% (95.3% vs 100%), and their mean error in estimating MRI-histopathology slice correspondences was reduced by 45% (1.12 slices vs 0.62 slices). When compared to a recent conventional registration approach and a deep learning registration approach, RAPHIA achieved better mapping of histopathology cancer labels, with an improved mean Dice coefficient of cancer regions outlined on MRI and the deformed histopathology (0.44 vs 0.48 vs 0.50), and a reduced mean per-case processing time (51 vs 11 vs 4.5 min). The improved performance by RAPHIA allows efficient processing of large datasets for the development of machine learning models for prostate cancer detection on MRI. Our code is publicly available at: https://github.com/pimed/RAPHIA.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Radiologia , Masculino , Humanos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
20.
Cancer ; 119(8): 1547-54, 2013 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-23335244

RESUMO

BACKGROUND: The short arm of chromosome 3 (3p) harbors the von Hippel-Lindau (VHL) tumor suppressor gene, and the long arm of chromosome 14 (14q) harbors the hypoxia-inducible factor 1α (HIF-1α) gene. The objective of this study was to evaluate the significance of 3p loss (loss VHL gene) and 14q loss (loss HIF-1α gene) in clear cell renal cell carcinoma (ccRCC). METHODS: In total, 288 ccRCC tumors underwent a prospective cytogenetic analysis for alterations in chromosomes 3p and 14q. Tumors were assigned to 1 of 4 possible chromosomal alterations: VHL +3p/+14q (VHL wild type [VHL-WT]), VHL +3p/-14q (VHL-WT plus HIF2α [WT/H2]), -3p/+14q (HIF1α and HIF2α [H1H2]), and -3p/-14q (HIF2α [H2]). RESULTS: Among patients who had loss of 3p, tumors with -3p/-14q (H2) alterations were larger (P = .002), had higher grade (P = .002) and stage (P = .001), and more often were metastatic (P = .029) than tumors that retained 14q (H1H2). All patients who had tumors with -3p/-14q (H2) had worse cancer-specific survival (P = .014), and patients who had localized disease (P = .012) and primary T1 (pT1) tumors (P = .008) had worse recurrence-free survival. In patients who had pT1 tumors, combined 3p/14q loss was an independent predictor of recurrence-free survival (hazard ratio, 11.19; 95% confidence interval, 1.91-65.63) and cancer-specific survival (hazard ratio, 15.93; 95% confidence interval, 3.09-82.16). The current investigation was limited by its retrospective design, single-center experience, and a lack of confirmatory protein analyses. CONCLUSIONS: Loss of chromosome 3p (the VHL gene) was associated with improved survival in patients with ccRCC, whereas loss of chromosome 14q (the HIF-1α gene) was associated with worse outcomes. The results of the current study support the hypothesis that HIF-1α functions as an important tumor suppressor gene in ccRCC.


Assuntos
Carcinoma de Células Renais/genética , Deleção Cromossômica , Cromossomos Humanos Par 14 , Cromossomos Humanos Par 3 , Neoplasias Renais/genética , Proteína Supressora de Tumor Von Hippel-Lindau/genética , Carcinoma de Células Renais/patologia , Análise Citogenética , Intervalo Livre de Doença , Genes Supressores de Tumor , Humanos , Neoplasias Renais/patologia , Pessoa de Meia-Idade , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA