Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 92(2): 253-259, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28940882

RESUMO

OBJECTIVES: To assess the safety and efficacy of the novel Resolute (R-) Onyx drug-eluting stent (DES). BACKGROUND: The R-Onyx DES consists of a composite wire with an outer shell of cobalt chromium alloy and a platinum-iridium inner core to enhance radiopacity, with thinner, swaged struts and modified stent geometry compared with the predicate Resolute DES, resulting in a slightly lower total drug load in most sizes. METHODS: This was a prospective, single-arm non-inferiority trial compared with a historical control. Patients with stable angina/ischemia and up to 2 de novo target lesions ≤35 mm long with reference vessel diameter (RVD) of 2.25-4.2 mm were enrolled. The primary endpoint was late lumen loss at 8-month follow-up. Propensity-score adjusted outcomes from the single-arm RESOLUTE-US trial served as the control. RESULTS: Seventy-five patients (85 lesions) were enrolled. Mean patient age was 66 ± 9 years, 73% were male, and 32% had diabetes. Mean lesion length was 14.28 ± 6.68 mm, mean RVD was 2.57 ± 0.48 mm, and 86% of lesions were class B2/C. In-stent late lumen loss at 8 months was 0.24 ± 0.39 mm with R-Onyx DES compared with 0.36 ± 0.52 mm with Resolute DES (P < 0.001 for noninferiority, P = 0.029 for superiority). At 8 months, clinically driven target lesion revascularization occurred in 3 patients (4.0%) and target lesion failure occurred in 5 patients (6.7%). CONCLUSIONS: In-stent late lumen loss is non-inferior, and appears to be superior, with the thin-strut novel composite wire R-Onyx DES compared with Resolute DES. Continued evolution of stent design can improve angiographic outcomes in complex lesions, even in the current era of next-generation DES.


Assuntos
Angina Estável/cirurgia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Angina Estável/diagnóstico por imagem , Fármacos Cardiovasculares/efeitos adversos , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Irídio , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Platina , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção , Estados Unidos
2.
J Am Coll Cardiol ; 79(9): 882-896, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35241222

RESUMO

BACKGROUND: The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up. OBJECTIVES: The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial. METHODS: A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference: -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves. CONCLUSIONS: The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Teorema de Bayes , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Desenho de Prótese , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
JACC Cardiovasc Interv ; 10(14): 1381-1388, 2017 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-28728650

RESUMO

OBJECTIVES: The aim of this study was to explore the safety and efficacy of a dedicated drug-eluting stent for the treatment of coronary lesions with very small reference vessel diameter (RVD). BACKGROUND: Smaller RVD is associated with increased risk for restenosis and target lesion failure (TLF) after stent implantation. METHODS: This was a prospective, single-arm, multicenter trial of the Resolute Onyx 2.0-mm zotarolimus-eluting stent. The primary endpoint was 12-month TLF, which was compared with a pre-specified performance goal. Subjects with stable or unstable angina or ischemia, target lesions ≤27 mm in length, and RVD ≥2.0 and <2.25 mm were eligible for enrollment. A subset of subjects underwent follow-up angiography at 13 months post-procedure. RESULTS: A total of 101 subjects with 104 lesions were enrolled. The mean age was 67.3 ± 9.6 years, 47% of subjects had diabetes, the mean lesion length was 12.6 ± 6.3 mm, and the mean RVD was 1.91 ± 0.26 mm. The rate of TLF at 12 months was 5.0%, fulfilling the pre-specified performance goal of 19% (p < 0.001). The rates of target lesion revascularization and target vessel myocardial infarction were 2.0% and 3.0%, respectively. There were no episodes of stent thrombosis. In-stent late lumen loss was 0.26 ± 0.48 mm, and the rate of binary restenosis was 12.0%. CONCLUSIONS: In this first report of a drug-eluting stent with a dedicated size to treat lesions with RVD <2.25 mm, the Resolute Onyx 2.0-mm zotarolimus-eluting stent was associated with a low rate of TLF and late lumen loss, without a signal for stent thrombosis. This novel-sized drug-eluting stent appears to be a feasible option for the treatment of coronary lesions in extremely small vessels. (Medtronic Resolute Onyx 2.0 mm Clinical Study; NCT02412501).


Assuntos
Angina Estável/terapia , Angina Instável/terapia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Angina Estável/diagnóstico por imagem , Angina Instável/diagnóstico por imagem , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
4.
J Am Coll Cardiol ; 57(17): 1778-83, 2011 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-21470813

RESUMO

OBJECTIVES: The RESOLUTE US (R-US) trial is a prospective, observational study designed to evaluate the clinical effectiveness of the Resolute zotarolimus-eluting stent (R-ZES) in a U.S. population. BACKGROUND: The R-ZES releases zotarolimus over a 6-month period in order to achieve optimal clinical effectiveness and safety. METHODS: The R-US trial recruited patients with de novo native coronary lesions suitable for 1- or 2-vessel treatment with stents from 2.25 to 4.0 mm in diameter. In the main analysis cohort (2.5- to 3.5-mm stents and single-lesion treatment), the primary endpoint was 12-month target lesion failure (TLF) defined as the composite of cardiac death, myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR), compared with data from Endeavor zotarolimus-eluting stent (E-ZES) trials, adjusting for baseline covariates through propensity scores. RESULTS: Overall, 1,402 patients were enrolled with a mean reference vessel diameter of 2.59 ± 0.47 mm and diabetes prevalence of 34.4%. In the main analysis cohort, TLF was 3.7% at 12 months compared with historical E-ZES results (TLF = 6.5%). The R-ZES met the 3.3% margin of noninferiority (rate difference = -2.8%, upper 1-sided 95% confidence interval: -1.3%, p < 0.001). The overall TLF rate was 4.7%, and rates of cardiac death, MI, and TLR were 0.7%, 1.4%, and 2.8%, respectively. The 12-month rate of stent thrombosis was 0.1%. CONCLUSIONS: The R-ZES achieved a very low rate of clinical restenosis while maintaining low rates of important clinical safety events such as death, MI, and stent thrombosis at 1-year follow-up. (The Medtronic RESOLUTE US Clinical Trial [R-US]; NCT00726453).


Assuntos
Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/epidemiologia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Sirolimo/análogos & derivados , Idoso , Estudos de Coortes , Doença da Artéria Coronariana/patologia , Reestenose Coronária/epidemiologia , Reestenose Coronária/patologia , Reestenose Coronária/prevenção & controle , Vasos Coronários/patologia , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Sirolimo/administração & dosagem , Resultado do Tratamento , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA