Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiographics ; 42(7): 2112-2130, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36018785

RESUMO

Endometrial cancer is the second most common gynecologic cancer worldwide and the most common gynecologic cancer in the United States, with an increasing incidence in high-income countries. Although the International Federation of Gynecology and Obstetrics (FIGO) staging system for endometrial cancer is a surgical staging system, contemporary published evidence-based data and expert opinions recommend MRI for treatment planning as it provides critical diagnostic information on tumor size and depth, extent of myometrial and cervical invasion, extrauterine extent, and lymph node status, all of which are essential in choosing the most appropriate therapy. Multiparametric MRI using a combination of T2-weighted sequences, diffusion-weighted imaging, and multiphase contrast-enhanced imaging is the mainstay for imaging assessment of endometrial cancer. Identification of important prognostic factors at MRI improves both treatment selection and posttreatment follow-up. MRI also plays a crucial role for fertility-preserving strategies and in patients who are not surgical candidates by helping guide therapy and identify procedural complications. This review is a product of the Society of Abdominal Radiology Uterine and Ovarian Cancer Disease-Focused Panel and reflects a multidisciplinary international collaborative effort to summarize updated information highlighting the role of MRI for endometrial cancer depiction and delineation, treatment planning, and follow-up. The article includes information regarding dedicated MRI protocols, tips for MRI reporting, imaging pitfalls, and strategies for image quality optimization. The roles of MRI-guided radiation therapy, hybrid PET/MRI, and advanced MRI techniques that are applicable to endometrial cancer imaging are also discussed. Online supplemental material is available for this article. ©RSNA, 2022.


Assuntos
Neoplasias do Endométrio , Neoplasias dos Genitais Femininos , Humanos , Feminino , Estadiamento de Neoplasias , Neoplasias do Endométrio/diagnóstico , Neoplasias do Endométrio/patologia , Neoplasias do Endométrio/cirurgia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias dos Genitais Femininos/patologia
2.
Int J Hyperthermia ; 37(1): 356-365, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32308071

RESUMO

Background: Thermoembolization presents a unique treatment alternative for patients diagnosed with hepatocellular carcinoma. The approach delivers a reagent that undergoes an exothermic chemical reaction and combines the benefits of embolic as well as thermal- and chemical-ablative therapy modalities. The target tissue and vascular bed are subjected to simultaneous hyperthermia, ischemia, and chemical denaturation in a single procedure. To guide optimal delivery, we developed a mathematical model for understanding the competing diffusive and convective effects observed in thermoembolization delivery protocols.Methods: A mixture theory formulation was used to mathematically model thermoembolization as chemically reacting transport of an electrophile, dichloroacetyl chloride (DCACl), within porous living tissue. Mass and energy transport of each relevant constituent are considered. Specifically, DCACl is injected into the vessels and exothermically reacts with water in the blood or tissue to form dichloroacetic acid and hydrochloric acid. Neutralization reactions are assumed instantaneous in this approach. We validated the mathematical model predictions of temperature using MR thermometry of the thermoembolization procedure performed in ex vivo kidney.Results: Mathematical modeling predictions of tissue death were highly dependent on the vascular geometry, injection pressure, and intrinsic amount of exothermic energy released from the chemical species, and were able to recapitulate the temperature distributions observed in MR thermometry.Conclusion: These efforts present a first step toward formalizing a mathematical model for thermoembolization and are promising for providing insight for delivery protocol optimization. While our approach captured the observed experimental temperature measurements, larger-scale experimental validation is needed to prioritize additional model complexity and fidelity.


Assuntos
Embolização Terapêutica/métodos , Modelos Teóricos , Humanos
3.
J Neurooncol ; 141(2): 475, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30635762

RESUMO

The original article was published with an incorrect protocol number. The correct protocol number is DR07-0585.

4.
Radiographics ; 39(5): 1476-1500, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31498740

RESUMO

Locally advanced human papillomavirus (HPV)-associated gynecologic cancers, including cervical, vaginal, and vulvar cancers, are treated primarily with radiation therapy (RT). Cervical cancer remains a leading cause of cancer death among women worldwide. The superior soft-tissue resolution of MRI compared with other imaging modalities makes it an ideal modality for RT planning, execution, and follow-up of these malignancies. This superiority has been corroborated in the literature when comparing MRI-based RT planning to radiography-based conventional treatment planning approaches. In 2005, the Groupe Européen de Curiethérapie and the European Society for Radiation Therapy and Oncology guidelines underscored the central role of MRI for successful implementation of three-dimensional image-based cervical cancer brachytherapy. The delineation of both gross tumor volume and clinical tumor volume for brachytherapy is performed at the time of each brachytherapy application, on the basis of the findings depicted on anatomic MR images. Contemporary knowledge concerning the role of MRI for RT planning in HPV-associated gynecologic cancers warrants an understanding of the epidemiology and clinical manifestations of these cancers, as well as knowledge of MRI protocol for cancer staging, selection of RT candidates, brachytherapy implant assessment, posttreatment surveillance, and delineation of treatment-related complications. Technical requirements, patient preparation, and image acquisition protocols are detailed in this review, and imaging-based treatment protocols are summarized. Knowledge of these fundamental concepts enables the radiologist to play an important role in diagnosis, staging, and posttreatment follow-up, helping to guide radiation oncologists and other clinicians in the management of these malignancies.©RSNA, 2019.


Assuntos
Braquiterapia/métodos , Neoplasias dos Genitais Femininos , Imageamento por Ressonância Magnética/métodos , Infecções por Papillomavirus , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Feminino , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Neoplasias dos Genitais Femininos/radioterapia , Neoplasias dos Genitais Femininos/virologia , Humanos , Infecções por Papillomavirus/diagnóstico por imagem , Infecções por Papillomavirus/radioterapia , Infecções por Papillomavirus/virologia
5.
Int J Hyperthermia ; 36(1): 730-738, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31362538

RESUMO

Purpose: MR temperature imaging (MRTI) was employed for visualizing the spatiotemporal evolution of the exotherm of thermoembolization, an investigative transarterial treatment for solid tumors. Materials and methods: Five explanted kidneys were injected with thermoembolic solutions, and monitored by MRTI. In three nonselective experiments, 5 ml of 4 mol/l dichloroacetyl chloride (DCA-Cl) solution in a hydrocarbon vehicle was injected via the main renal artery. For two of these three, MRTI temperature data were compared to fiber optic thermal probes. Another two kidneys received selective injections, treating only portions of the kidneys with 1 ml of 2 mol/l DCA-Cl. MRTI data were acquired and compared to changes in pre- and post-injection CT. Specimens were bisected and photographed for gross pathology 24 h post-procedure. Results: MRTI temperature estimates were within ±1 °C of the probes. In experiments without probes, MRTI measured increases of 30 °C. Some regions had not reached peak temperature by the end of the >18 min acquisition. MRTI indicated the initial heating occurred in the renal cortex, gradually spreading more proximally toward the main renal artery. Gross pathology showed the nonselective injection denatured the entire kidney whereas in the selective injections, only the treated territory was coagulated. Conclusion: The spatiotemporal evolution of thermoembolization was visualized for the first time using noninvasive MRTI, providing unique insight into the thermodynamics of thermoembolization. Précis Thermoembolization is being investigated as a novel transarterial treatment. In order to begin to characterize delivery of this novel treatment modality and aid translation from the laboratory to patients, we employ MR temperature imaging to visualize the spatiotemporal distribution of temperature from thermoembolization in ex vivo tissue.


Assuntos
Embolização Terapêutica , Imageamento por Ressonância Magnética , Termografia , Animais , Rim/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem , Suínos , Temperatura
6.
Proc Natl Acad Sci U S A ; 113(7): 1877-82, 2016 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-26839407

RESUMO

A major challenge of targeted molecular imaging and drug delivery in cancer is establishing a functional combination of ligand-directed cargo with a triggered release system. Here we develop a hydrogel-based nanotechnology platform that integrates tumor targeting, photon-to-heat conversion, and triggered drug delivery within a single nanostructure to enable multimodal imaging and controlled release of therapeutic cargo. In proof-of-concept experiments, we show a broad range of ligand peptide-based applications with phage particles, heat-sensitive liposomes, or mesoporous silica nanoparticles that self-assemble into a hydrogel for tumor-targeted drug delivery. Because nanoparticles pack densely within the nanocarrier, their surface plasmon resonance shifts to near-infrared, thereby enabling a laser-mediated photothermal mechanism of cargo release. We demonstrate both noninvasive imaging and targeted drug delivery in preclinical mouse models of breast and prostate cancer. Finally, we applied mathematical modeling to predict and confirm tumor targeting and drug delivery. These results are meaningful steps toward the design and initial translation of an enabling nanotechnology platform with potential for broad clinical applications.


Assuntos
Antineoplásicos/administração & dosagem , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/tratamento farmacológico , Modelos Animais de Doenças , Imagem Multimodal , Nanotecnologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/tratamento farmacológico , Animais , Sistemas de Liberação de Medicamentos , Feminino , Raios Infravermelhos , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Ressonância de Plasmônio de Superfície
7.
J Neurooncol ; 137(1): 57-65, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29204838

RESUMO

We analyzed volumetric response of metastatic brain tumors that progressed despite treatment with stereotactic radiosurgery (SRS) after treatment with laser interstitial thermal therapy (LITT). We retrospectively reviewed consecutive patients treated from 1/2012 to 10/2015 with LITT for metastatic brain tumors demonstrating progression after SRS. Volumes were quantified using MRI with contrast-enhanced T1-weighted (T1W) and fluid-attenuated inversion recovery (FLAIR). Fifty lesions from 36 patients were studied. Lesions were assessed prior to LITT, immediately after LITT, 0-90 days after LITT, 90-180 days after LITT, 180-270 days after LITT, and 270-360 days after LITT. The median T1W volume was 5.05 cc (range 0.54-23.31 cc) before LITT treatment (n = 50), 7.70 cc (range 1.72-38.76 cc) 0-90 days after LITT (n = 47), and 3.68 cc (range 1.282-48.31 cc) 180-270 days after LITT (n = 21). The median FLAIR volume was 43.36 cc (range 3.09-233.01 cc) before LITT treatment (n = 50), 37.13 cc (range 3.48-244.23 cc) 0-90 days after LITT (n = 43), 31.68 cc (range 1.6-248.75 cc) 180-270 days after LITT (n = 18). The 6-month FLAIR volume showed a statistically significant reduction compared to pretreatment (p = 0.04). After selecting for cases where patients had two or more post-operative MRIs, we found that 24 lesions (63%) demonstrated an overall downward trend and 14 lesions (37%) demonstrated an upward trend. The median pre-treatment T1W volume for the patients whose lesions demonstrated volumetric reduction after LITT was 3.54 cc (range 0.539-10.06 cc) and for those who did not demonstrate volumetric reduction after LITT it was 8.81 cc (range 0.926-23.313 cc). The pre-treatment tumor volume plays a significant role in determining response to LITT with smaller tumor volumes responding better to LITT than tumors with larger volumes.


Assuntos
Neoplasias Encefálicas , Terapia a Laser/métodos , Radiocirurgia , Adulto , Idoso , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Imagem de Difusão por Ressonância Magnética , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
8.
Nanotechnology ; 29(16): 165101, 2018 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-29438105

RESUMO

OBJECTIVE: To evaluate the feasibility of visualizing bone marrow-derived human mesenchymal stem cells (MSCs) labeled with a gold-coated magnetic resonance (MR)-active multifunctional nanoparticle and injected via the carotid artery for assessing the extent of MSC homing in glioma-bearing mice. MATERIALS AND METHODS: Nanoparticles containing superparamagnetic iron oxide coated with gold (SPIO@Au) with a diameter of ∼82 nm and maximum absorbance in the near infrared region were synthesized. Bone marrow-derived MSCs conjugated with green fluorescent protein (GFP) were successfully labeled with SPIO@Au at 4 µg ml-1 and injected via the internal carotid artery in six mice bearing orthotopic U87 tumors. Unlabeled MSCs were used as a control. The ability of SPIO@Au-loaded MSCs to be imaged using MR and photoacoustic (PA) imaging at t = 0 h, 2 h, 24 h, and 72 h was assessed using a 7 T Bruker Biospec experimental MR scanner and a Vevo LAZR PA imaging system with a 5 ns laser as the excitation source. Histological analysis of the brain tissue was performed 72 h after MSC injection using GFP fluorescence, Prussian blue staining, and hematoxylin-and-eosin staining. RESULTS: MSCs labeled with SPIO@Au at 4 µg ml-1 did not exhibit cell death or any adverse effects on differentiation or migration. The PA signal in tumors injected with SPIO@Au-loaded MSCs was clearly more enhanced post-injection, as compared with the tumors injected with unlabeled MSCs at t = 72 h. Using the same mice, T2-weighted MR imaging results taken before injection and at t = 2 h, 24 h, and 72 h were consistent with the PA imaging results, showing significant hypointensity of the tumor in the presence of SPIO@Au-loaded MSCs. Histological analysis also showed co-localization of GFP fluorescence and iron, thereby confirming that SPIO@Au-labeled MSCs continue to carry their nanoparticle payloads even at 72 h after injection. CONCLUSIONS: Our results demonstrated the feasibility of tracking carotid artery-injected SPIO@Au-labeled MSCs in vivo via MR and PA imaging.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/administração & dosagem , Técnicas Fotoacústicas/métodos , Animais , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Sobrevivência Celular , Meios de Contraste/administração & dosagem , Modelos Animais de Doenças , Glioma/patologia , Ouro/química , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Humanos , Injeções Intra-Arteriais , Nanopartículas de Magnetita/química , Nanopartículas de Magnetita/ultraestrutura , Masculino , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/química , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Camundongos , Camundongos Nus , Tamanho da Partícula , Coloração e Rotulagem
9.
Int J Hyperthermia ; 34(6): 687-696, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-28830311

RESUMO

Post-treatment imaging is the principal method for evaluating thermal lesions following image-guided thermal ablation procedures. While real-time temperature feedback using magnetic resonance temperature imaging (MRTI) is a complementary tool that can be used to optimise lesion size throughout the procedure, a thermal dose model is needed to convert temperature-time histories to estimates of thermal damage. However, existing models rely on empirical parameters derived from laboratory experiments that are not direct indicators of post-treatment radiologic appearance. In this work, we investigate a technique that uses perioperative MR data to find novel thermal dose model parameters that are tailored to the appearance of the thermal lesion on post-treatment contrast-enhanced imaging. Perioperative MR data were analysed for five patients receiving magnetic resonance-guided laser-induced thermal therapy (MRgLITT) for brain metastases. The characteristic enhancing ring was manually segmented on post-treatment T1-weighted imaging and registered into the MRTI geometry. Post-treatment appearance was modelled using a coupled Arrhenius-logistic model and non-linear optimisation techniques were used to find the maximum-likelihood kinetic parameters and dose thresholds that characterise the inner and outer boundary of the enhancing ring. The parameter values and thresholds were consistent with previous investigations, while the average difference between the predicted and segmented boundaries was on the order of one pixel (1 mm). The areas predicted using the optimised model parameters were also within 1 mm of those predicted by clinically utilised dose models. This technique makes clinically acquired data available for investigating new thermal dose model parameters driven by clinically relevant endpoints.


Assuntos
Imageamento por Ressonância Magnética/métodos , Idoso , Feminino , Humanos , Pessoa de Meia-Idade
10.
Int J Hyperthermia ; 34(1): 101-111, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28540820

RESUMO

PURPOSE: Neurosurgical laser ablation is experiencing a renaissance. Computational tools for ablation planning aim to further improve the intervention. Here, global optimisation and inverse problems are demonstrated to train a model that predicts maximum laser ablation extent. METHODS: A closed-form steady state model is trained on and then subsequently compared to N = 20 retrospective clinical MR thermometry datasets. Dice similarity coefficient (DSC) is calculated to provide a measure of region overlap between the 57 °C isotherms of the thermometry data and the model-predicted ablation regions; 57 °C is a tissue death surrogate at thermal steady state. A global optimisation scheme samples the dominant model parameter sensitivities, blood perfusion (ω) and optical parameter (µeff) values, throughout a parameter space totalling 11 440 value-pairs. This represents a lookup table of µeff-ω pairs with the corresponding DSC value for each patient dataset. The µeff-ω pair with the maximum DSC calibrates the model parameters, maximising predictive value for each patient. Finally, leave-one-out cross-validation with global optimisation information trains the model on the entire clinical dataset, and compares against the model naïvely using literature values for ω and µeff. RESULTS: When using naïve literature values, the model's mean DSC is 0.67 whereas the calibrated model produces 0.82 during cross-validation, an improvement of 0.15 in overlap with the patient data. The 95% confidence interval of the mean difference is 0.083-0.23 (p < 0.001). CONCLUSIONS: During cross-validation, the calibrated model is superior to the naïve model as measured by DSC, with +22% mean prediction accuracy. Calibration empowers a relatively simple model to become more predictive.


Assuntos
Encéfalo/diagnóstico por imagem , Terapia a Laser/métodos , Imageamento por Ressonância Magnética/métodos , Calibragem , Humanos , Resultado do Tratamento
11.
Magn Reson Med ; 73(4): 1662-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24809984

RESUMO

PURPOSE: Several methods in MRI use the phase information of the complex signal and require phase unwrapping (e.g., B0 field mapping, chemical shift imaging, and velocity measurements). In this work, an algorithm was developed focusing on the needs and requirements of MR temperature imaging applications. METHODS: The proposed method performs fully automatic unwrapping using a list of all pixels sorted by magnitude in descending order and creates and merges clusters of unwrapped pixels until the entire image is unwrapped. The algorithm was evaluated using simulated phantom data and in vivo clinical temperature imaging data. RESULTS: The evaluation of the phantom data demonstrated no errors in regions with signal-to-noise ratios of at least 4.5. For the in vivo data, the algorithm did not fail at an average of more than one pixel for signal-to-noise ratios greater than 6.3. Processing times less than 30 ms per image were achieved by unwrapping pixels inside a region of interest (53 × 53 pixels) used for referenceless MR temperature imaging. CONCLUSIONS: The algorithm has been demonstrated to operate robustly with clinical in vivo data in this study. The processing time for common regions of interest in referenceless MR temperature imaging allows for online updates of temperature maps without noticeable delay.


Assuntos
Algoritmos , Temperatura Corporal/fisiologia , Encéfalo/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Termografia/métodos , Encéfalo/anatomia & histologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
J Magn Reson Imaging ; 39(3): 590-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24532376

RESUMO

PURPOSE: To assess the correlation among MR elastography (MRE) measured liver stiffness (LS), liver fibrosis, and hepatic venous pressure gradient (HVPG) in a swine model of cirrhosis. MATERIALS AND METHODS: Three swine served as controls, and liver fibrosis was induced in eight swine by transarterial embolization. LS and HVPG were obtained at baseline and 4 weeks (prenecropsy) following induction of liver fibrosis. RESULTS: Four weeks following the induction of liver cirrhosis, experimental animals developed an increase in HVPG of 8.0±6.4 mmHg compared with 0.3±1.2 mmHg for controls (P=0.08). Over the same timeframe, mean MRE-measured LS increased 0.82±0.39 kPa for experimental swine and 0.1±0.05 kPa for controls (P=0.01). A positive correlation was observed between increases in HVPG and LS (ρ=0.682; P=0.02). Liver fibrosis was measured on explanted livers at 4 weeks and yielded mean fibrosis scores of 2.8 for experimental animals and 0 for controls (P=0.0016). A positive correlation was observed between higher LS and liver fibrosis (ρ=0.884; P=0.0003). CONCLUSION: MRE is a reliable noninvasive technique to measure LS in a swine model of cirrhosis. Significant positive correlations were observed between LS and HVPG as well as LS and fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico , Pressão na Veia Porta , Análise de Variância , Animais , Biópsia por Agulha , Modelos Animais de Doenças , Imuno-Histoquímica , Cirrose Hepática/patologia , Curva ROC , Distribuição Aleatória , Valores de Referência , Sus scrofa , Suínos
13.
Int J Hyperthermia ; 30(1): 47-55, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24350668

RESUMO

PURPOSE: Optically activated nanoparticle-mediated heating for thermal therapy applications is an area of intense research. The ability to characterise the spatio-temporal heating potential of these particles for use in modelling under various exposure conditions can aid in the exploration of new approaches for therapy as well as more quantitative prospective approaches to treatment planning. The purpose of this research was to investigate an inverse solution to the heat equation using magnetic resonance temperature imaging (MRTI) feedback, for providing optical characterisation of two types of nanoparticles (gold-silica nanoshells and gold nanorods). METHODS: The optical absorption of homogeneous nanoparticle-agar mixtures was measured during exposure to an 808 nm laser using real-time MRTI. A coupled finite element solution of heat transfer was registered with the data and used to solve the inverse problem. The L2 norm of the difference between the temperature increase in the model and MRTI was minimised using a pattern search algorithm by varying the absorption coefficient of the mixture. RESULTS: Absorption fractions were within 10% of literature values for similar nanoparticles. Comparison of temporal and spatial profiles demonstrated good qualitative agreement between the model and the MRTI. The weighted root mean square error was <1.5 σMRTI and the average Dice similarity coefficient for ΔT = 5 °C isotherms was >0.9 over the measured time interval. CONCLUSION: This research demonstrates the feasibility of using an indirect method for making minimally invasive estimates of nanoparticle absorption that might be expanded to analyse a variety of geometries and particles of interest.


Assuntos
Imageamento por Ressonância Magnética , Nanoconchas/química , Nanotubos/química , Absorção , Algoritmos , Análise de Elementos Finitos , Ouro/química , Hipertermia Induzida , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Fenômenos Ópticos , Imagens de Fantasmas , Dióxido de Silício/química , Temperatura , Condutividade Térmica
14.
Cancers (Basel) ; 16(10)2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38792000

RESUMO

Magnetic resonance imaging (MRI) can facilitate accurate organ delineation and optimal dose distributions in high-dose-rate (HDR) MRI-Assisted Radiosurgery (MARS). Its use for this purpose has been limited by the lack of positive-contrast MRI markers that can clearly delineate the lumen of the HDR applicator and precisely show the path of the HDR source on T1- and T2-weighted MRI sequences. We investigated a novel MRI positive-contrast HDR brachytherapy or interventional radiotherapy line marker, C4:S, consisting of C4 (visible on T1-weighted images) complexed with saline. Longitudinal relaxation time (T1) and transverse relaxation time (T2) for C4:S were measured on a 1.5 T MRI scanner. High-density polyethylene (HDPE) tubing filled with C4:S as an HDR brachytherapy line marker was tested for visibility on T1- and T2-weighted MRI sequences in a tissue-equivalent female ultrasound training pelvis phantom. Relaxivity measurements indicated that C4:S solution had good T1-weighted contrast (relative to oil [fat] signal intensity) and good T2-weighted contrast (relative to water signal intensity) at both room temperature (relaxivity ratio > 1; r2/r1 = 1.43) and body temperature (relaxivity ratio > 1; r2/r1 = 1.38). These measurements were verified by the positive visualization of the C4:S (C4/saline 50:50) HDPE tube HDR brachytherapy line marker on both T1- and T2-weighted MRI sequences. Orientation did not affect the relaxivity of the C4:S contrast solution. C4:S encapsulated in HDPE tubing can be visualized as a positive line marker on both T1- and T2-weighted MRI sequences. MRI-guided HDR planning may be possible with these novel line markers for HDR MARS for several types of cancer.

15.
Int J Hyperthermia ; 29(4): 324-35, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23692295

RESUMO

PURPOSE: A generalised polynomial chaos (gPC) method is used to incorporate constitutive parameter uncertainties within the Pennes representation of bioheat transfer phenomena. The stochastic temperature predictions of the mathematical model are critically evaluated against MR thermometry data for planning MR-guided laser-induced thermal therapies (MRgLITT). METHODS: The Pennes bioheat transfer model coupled with a diffusion theory approximation of laser tissue interaction was implemented as the underlying deterministic kernel. A probabilistic sensitivity study was used to identify parameters that provide the most variance in temperature output. Confidence intervals of the temperature predictions are compared to MR temperature imaging (MRTI) obtained during phantom and in vivo canine (n = 4) MRgLITT experiments. The gPC predictions were quantitatively compared to MRTI data using probabilistic linear and temporal profiles as well as 2-D 60 °C isotherms. RESULTS: Optical parameters provided the highest variance in the model output (peak standard deviation: anisotropy 3.51 °C, absorption 2.94 °C, scattering 1.84 °C, conductivity 1.43 °C, and perfusion 0.94 °C). Further, within the statistical sense considered, a non-linear model of the temperature and damage-dependent perfusion, absorption, and scattering is captured within the confidence intervals of the linear gPC method. Multivariate stochastic model predictions using parameters with the dominant sensitivities show good agreement with experimental MRTI data. CONCLUSIONS: Given parameter uncertainties and mathematical modelling approximations of the Pennes bioheat model, the statistical framework demonstrates conservative estimates of the therapeutic heating and has potential for use as a computational prediction tool for thermal therapy planning.


Assuntos
Hipertermia Induzida/métodos , Modelos Teóricos , Animais , Encéfalo , Cães , Lasers , Imageamento por Ressonância Magnética , Dinâmica não Linear , Temperatura , Incerteza
16.
J Digit Imaging ; 26(5): 971-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23589186

RESUMO

Computer-aided diagnosis (CAD) systems are software programs that use algorithms to find patterns associated with breast cancer on breast magnetic resonance imaging (MRI). The most commonly used CAD systems in the USA are CADstream (CS) (Merge Healthcare Inc., Chicago, IL) and DynaCAD for Breast (DC) (Invivo, Gainesville, FL). Our primary objective in this study was to compare the CS and DC breast MRI CAD systems for diagnostic accuracy and postprocessed image quality. Our secondary objective was to compare the evaluation times of radiologists using each system. Three radiologists evaluated 30 biopsy-proven malignant lesions and 29 benign lesions on CS and DC and rated the lesions' malignancy status using the Breast Imaging Reporting and Data System. Image quality was ranked on a 0-5 scale, and mean reading times were also recorded. CS detected 70 % of the malignant and 32 % of the benign lesions while DC detected 81 % of the malignant lesions and 34 % of the benign lesions. Analysis of the area under the receiver operating characteristic curve revealed that the difference in diagnostic performance was not statistically significant. On image quality scores, CS had significantly higher volume rendering (VR) (p < 0.0001) and motion correction (MC) scores (p < 0.0001). There were no statistically significant differences in the remaining image quality scores. Differences in evaluation times between DC and CS were also not statistically significant. We conclude that both CS and DC perform similarly in aiding detection of breast cancer on MRI. MRI CAD selection will likely be based on other factors, such as user interface and image quality preferences, including MC and VR.


Assuntos
Neoplasias da Mama/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Adulto , Idoso , Área Sob a Curva , Mama/patologia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
17.
Brachytherapy ; 22(6): 736-745, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37612174

RESUMO

PURPOSE: To determine the feasibility of quantitative apparent diffusion coefficient (ADC) acquisition during magnetic resonance imaging-guided brachytherapy (MRgBT) using reduced field-of-view (rFOV) diffusion-weighted imaging (DWI). METHODS AND MATERIALS: T2-weighted (T2w) MR and full-FOV single-shot echo planar (ssEPI) DWI were acquired in 7 patients with cervical or vaginal malignancy at baseline and prior to brachytherapy, while rFOV-DWI was acquired during MRgBT following brachytherapy applicator placement. The gross target volume (GTV) was contoured on the T2w images and registered to the ADC map. Voxels at the GTV's maximum Maurer distance comprised a central sub-volume (GTVcenter). Contour ADC mean and standard deviation were compared between timepoints using repeated measures ANOVA. RESULTS: ssEPI-DWI mean ADC increased between baseline and prebrachytherapy from 1.03 ± 0.18 10-3 mm2/s to 1.34 ± 0.28 10-3 mm2/s for the GTV (p = 0.06) and from 0.84 ± 0.13 10-3 mm2/s to 1.26 ± 0.25 10-3 mm2/s at the level of the GTVcenter (p = 0.03), consistent with early treatment response. rFOV-DWI during MRgBT demonstrated mean ADC values of 1.28 ± 0.14 10-3 mm2/s and 1.28 ± 0.19 10-3 mm2/s for the GTV and GTVcenter, respectively (p = 0.02 and p = 0.03 relative to baseline). No significant differences were observed between ssEPI-DWI and rFOV-DWI ADC measurements. CONCLUSIONS: Quantitative ADC measurement in the setting of MRI guided brachytherapy implant placement for cervical and vaginal cancers is feasible using rFOV-DWI, with comparable mean ADC comparable to prebrachytherapy ssEPI-DWI, and may enable MRI-guided radiotherapy targeting of low ADC, radiation resistant sub-volumes of tumor.


Assuntos
Braquiterapia , Neoplasias Vaginais , Feminino , Humanos , Neoplasias Vaginais/diagnóstico por imagem , Neoplasias Vaginais/radioterapia , Braquiterapia/métodos , Estudos de Viabilidade , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
18.
J Med Imaging (Bellingham) ; 10(6): 065501, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37937259

RESUMO

Purpose: To improve segmentation accuracy in head and neck cancer (HNC) radiotherapy treatment planning for the 1.5T hybrid magnetic resonance imaging/linear accelerator (MR-Linac), three-dimensional (3D), T2-weighted, fat-suppressed magnetic resonance imaging sequences were developed and optimized. Approach: After initial testing, spectral attenuated inversion recovery (SPAIR) was chosen as the fat suppression technique. Five candidate SPAIR sequences and a nonsuppressed, T2-weighted sequence were acquired for five HNC patients using a 1.5T MR-Linac. MR physicists identified persistent artifacts in two of the SPAIR sequences, so the remaining three SPAIR sequences were further analyzed. The gross primary tumor volume, metastatic lymph nodes, parotid glands, and pterygoid muscles were delineated using five segmentors. A robust image quality analysis platform was developed to objectively score the SPAIR sequences on the basis of qualitative and quantitative metrics. Results: Sequences were analyzed for the signal-to-noise ratio and the contrast-to-noise ratio and compared with fat and muscle, conspicuity, pairwise distance metrics, and segmentor assessments. In this analysis, the nonsuppressed sequence was inferior to each of the SPAIR sequences for the primary tumor, lymph nodes, and parotid glands, but it was superior for the pterygoid muscles. The SPAIR sequence that received the highest combined score among the analysis categories was recommended to Unity MR-Linac users for HNC radiotherapy treatment planning. Conclusions: Our study led to two developments: an optimized, 3D, T2-weighted, fat-suppressed sequence that can be disseminated to Unity MR-Linac users and a robust image quality analysis pathway that can be used to objectively score SPAIR sequences and can be customized and generalized to any image quality optimization protocol. Improved segmentation accuracy with the proposed SPAIR sequence will potentially lead to improved treatment outcomes and reduced toxicity for patients by maximizing the target coverage and minimizing the radiation exposure of organs at risk.

19.
J Vasc Interv Radiol ; 23(4): 553-61, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22341633

RESUMO

PURPOSE: To evaluate the effects of near-infrared (NIR) laser irradiation of microspheres (MS) containing hollow gold nanospheres (HAuNS) and paclitaxel (PTX) administered intraarterially in an animal model. MATERIALS AND METHODS: For the ex vivo experiments, VX2 tumor-bearing rabbits underwent administration of MS-HAuNS or MS via the hepatic artery (HA). The animals were killed, the liver tumors were subjected to NIR irradiation, and temperature changes were estimated with magnetic resonance (MR) imaging. For the in vivo study, VX2 tumor-bearing rabbits were randomly assigned to three groups: MS-HAuNS-PTX-plus-NIR, MS-HAuNS-PTX, and saline-plus-NIR. Laser irradiation was delivered at 1 hour and at 3 days after administration of saline or MS-HAuNS-PTX via the HA. Animals were euthanized, and tumors were analyzed for necrosis and apoptosis. Plasma samples were collected from the MS-HAuNS-PTX-plus-NIR animals for PTX analysis. RESULTS: Ex vivo experiments showed intratumoral heating in animals that received MS-HAuNS but no temperature change in animals that received MS. Animals treated with MS-HAuNS-PTX-plus-NIR showed a transient increase in plasma PTX levels after each NIR irradiation and significantly greater tumor necrosis than animals that received MS-HAuNS-PTX or saline-plus-NIR (44.9% vs 13.8% or 23.7%; P < .0001). The mean apoptotic index in the MS-HAuNS-PTX-plus-NIR group (5.01 ± 1.66) was significantly higher than the mean apoptotic index in the MS-HAuNS-PTX (2.99 ± 0.97) or saline-plus-NIR (1.96 ± 0.40) groups (P = .0013). CONCLUSIONS: NIR laser irradiation after MS-HAuNS-PTX administration results in intratumoral heating and increases the efficacy of treatment. Further studies are required to evaluate the optimal laser settings to maximize therapeutic efficacy.


Assuntos
Terapia a Laser/métodos , Neoplasias Hepáticas/terapia , Nanocápsulas/administração & dosagem , Paclitaxel/administração & dosagem , Implantes Absorvíveis , Animais , Linhagem Celular Tumoral , Terapia Combinada , Raios Infravermelhos/uso terapêutico , Injeções Intra-Arteriais , Microesferas , Coelhos , Resultado do Tratamento
20.
MAGMA ; 25(1): 15-22, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21373916

RESUMO

OBJECT: Proton resonance frequency shift thermometry is sensitive to breathing motion that leads to incorrect phase differences. In this work, a novel velocity-sensitive navigator technique for triggering MR thermometry image acquisition is presented. MATERIALS AND METHODS: A segmented echo planar imaging pulse sequence was modified for velocity-triggered temperature mapping. Trigger events were generated when the estimated velocity value was less than 0.2 cm/s during the slowdown phase in parallel to the velocity-encoding direction. To remove remaining high-frequency spikes from pulsation in real time, a Kalman filter was applied to the velocity navigator data. A phantom experiment with heating and an initial volunteer experiment without heating were performed to show the applicability of this technique. Additionally, a breath-hold experiment was conducted for comparison. RESULTS: A temperature rise of ΔT = +37.3°C was seen in the phantom experiment, and a root mean square error (RMSE) outside the heated region of 2.3°C could be obtained for periodic motion. In the volunteer experiment, a RMSE of 2.7°C/2.9°C (triggered vs. breath hold) was measured. CONCLUSION: A novel velocity navigator with Kalman filter postprocessing in real time significantly improves the temperature accuracy over non-triggered acquisitions and suggests being comparable to a breath-held acquisition. The proposed technique might be clinically applied for monitoring of thermal ablations in abdominal organs.


Assuntos
Imageamento por Ressonância Magnética/métodos , Algoritmos , Temperatura Corporal , Imagem Ecoplanar/métodos , Desenho de Equipamento , Temperatura Alta , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Movimento (Física) , Imagens de Fantasmas , Prótons , Respiração , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA