Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39028767

RESUMO

Catheter ablation (CA) has become an established treatment strategy for managing recurrent ventricular tachycardias (VTs) in patients with structural heart disease. In recent years, percutaneous mechanical circulatory support (PMCS) devices have been increasingly used intra-operatively to improve the ablation outcome. One indication would be rescue therapy for patients who develop haemodynamic deterioration during the ablation. However, more efforts are focused on identifying subjects who are at high risk of such deterioration and could benefit from the pre-emptive use of the PMCS. The third reason to use PMCS could be the inability to identify diffuse substrate, especially in non-ischaemic cardiomyopathy. This paper reviews available experiences using various types of PMCS in different clinical scenarios. Although PMCS allows mapping during VT, it does not significantly influence acute outcomes and not convincingly long-term outcomes. On the contrary, the complication rate appears to be higher in PMCS cohorts. Our data suggest that even in patients with severe left ventricular dysfunction, the substrate modification can be performed without the need for general anaesthesia and risk of haemodynamic decompensation. In end-stage heart failure associated with the electrical storm, implantation of a left ventricular assist device (or PMCS with a transition to the left ventricular assist device) might be the preferred strategy before CA. In high-risk patients who are not potential candidates for these treatment options, radiotherapy could be considered as a bail-out treatment of recurrent VTs. These approaches should be studied in prospective trials.


Assuntos
Ablação por Cateter , Coração Auxiliar , Taquicardia Ventricular , Humanos , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Fatores de Risco , Hemodinâmica
2.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38988256

RESUMO

AIMS: A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF. METHODS AND RESULTS: The study population consisted of 44 patients (16 women, aged 61 ± 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 ± 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 ± 75 days and a total of 52% patients remained free of any VA. CONCLUSION: Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Idoso , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Estudos Prospectivos , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas
3.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38864730

RESUMO

AIMS: Patients with structural heart disease (SHD) undergoing catheter ablation (CA) for ventricular tachycardia (VT) are at considerable risk of periprocedural complications, including acute haemodynamic decompensation (AHD). The PAINESD score was proposed to predict the risk of AHD. The goal of this study was to validate the PAINESD score using the retrospective analysis of data from a large-volume heart centre. METHODS AND RESULTS: Patients who had their first radiofrequency CA for SHD-related VT between August 2006 and December 2020 were included in the study. Procedures were mainly performed under conscious sedation. Substrate mapping/ablation was performed primarily during spontaneous rhythm or right ventricular pacing. A purposely established institutional registry for complications of invasive procedures was used to collect all periprocedural complications that were subsequently adjudicated using the source medical records. Acute haemodynamic decompensation triggered by CA procedure was defined as intraprocedural or early post-procedural (<12 h) development of acute pulmonary oedema or refractory hypotension requiring urgent intervention. The study cohort consisted of 1124 patients (age, 63 ± 13 years; males, 87%; ischaemic cardiomyopathy, 67%; electrical storm, 25%; New York Heart Association Class, 2.0 ± 1.0; left ventricular ejection fraction, 34 ± 12%; diabetes mellitus, 31%; chronic obstructive pulmonary disease, 12%). Their PAINESD score was 11.4 ± 6.6 (median, 12; interquartile range, 6-17). Acute haemodynamic decompensation complicated the CA procedure in 13/1124 = 1.2% patients and was not predicted by PAINESD score with AHD rates of 0.3, 1.8, and 1.1% in subgroups by previously published PAINESD terciles (<9, 9-14, and >14). However, the PAINESD score strongly predicted mortality during the follow-up. CONCLUSION: Primarily substrate-based CA of SHD-related VT performed under conscious sedation is associated with a substantially lower rate of AHD than previously reported. The PAINESD score did not predict these events. The application of the PAINESD score to the selection of patients for pre-emptive mechanical circulatory support should be reconsidered.


Assuntos
Ablação por Cateter , Hemodinâmica , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Estudos Retrospectivos , Cicatriz/fisiopatologia , Idoso , Hipotensão/etiologia , Hipotensão/fisiopatologia , Hipotensão/diagnóstico , Edema Pulmonar/etiologia , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico , Fatores de Risco
4.
J Cardiovasc Electrophysiol ; 33(12): 2569-2577, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36069129

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the most common sustained arrhythmia in humans. The onset of the arrhythmia can significantly impair cardiac function. This hemodynamic deterioration has been explained by several mechanisms such as the loss of atrial contraction, shortening of ventricular filling, or heart rhythm irregularity. This study sought to evaluate the relative hemodynamic contribution of each of these components during in vivo simulated human AF. METHODS: Twelve patients undergoing catheter ablation for paroxysmal AF were paced simultaneously from the proximal coronary sinus and the His bundle region according to prescribed sequences of irregular R-R intervals with the average rate of 90 and 130 bpm, which were extracted from the database of digital ECG recordings of AF from other patients. The simulated AF was compared to regular atrial pacing with spontaneous atrioventricular conduction and regular simultaneous atrioventricular pacing at the same heart rate. Beat-by-beat left atrial and left ventricular pressures, including LV dP/dT and Tau index were assessed by direct invasive measurement; beat-by-beat stroke volume and cardiac output (index) were assessed by simultaneous pulse-wave doppler intracardiac echocardiography. RESULTS: Simulated AF led to significant impairment of left ventricular systolic and diastolic function. Both loss of atrial contraction and heart rate irregularity significantly contributed to hemodynamic impairment. This effect was pronounced with increasing heart rate. CONCLUSION: Our findings strengthen the rationale for therapeutic strategies aiming at rhythm control and heart rate regularization in patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Função Ventricular Esquerda , Ablação por Cateter/efeitos adversos , Hemodinâmica , Frequência Cardíaca , Estimulação Cardíaca Artificial
5.
Europace ; 24(4): 598-605, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34791165

RESUMO

AIM: To describe clinical characteristics, procedural details, specific challenges, and outcomes in patients with HeartMate3™ (HM3), a left ventricular assist device system with a magnetically levitated pump, undergoing ventricular tachycardia ablation (VTA). METHODS AND RESULTS: Data were collected from patients with an HM3 system who underwent VTA in seven tertiary centres. Data included baseline patient characteristics, procedural data, mortality, and arrhythmia-free survival. The study cohort included 19 patients with cardiomyopathy presenting with ventricular tachycardia (VT) (53% with VT storm). Ventricular tachycardias were induced in 89% of patients and a total of 41 VTs were observed. Severe electromagnetic interference was present on the surface electrocardiogram. Hence, VT localization required analysis of intra-cardiac signals or the use of filter in the 40-20 Hz range. The large house pump HM3 design obscured the cannula inflow and therefore multi imaging modalities were necessary to avoid catheter entrapment in the cannula. A total of 32 VTs were mapped and were successfully ablated (31% to the anterior wall, 38% to the septum and only 9% to the inflow cannula region). Non-inducibility of any VT was reached in 11 patients (58%). Over a follow-up of 429 (interquartile range 101-692) days, 5 (26%) patients underwent a redo VT ablation due to recurrent VTA and 2 (11%) patients died. CONCLUSIONS: Ventricular tachycardia ablation in patients with HM3 is feasible and safe when done in the appropriate setup. Long-term arrhythmia-free survival is acceptable but not well predicted by non-inducibility at the end of the procedure.


Assuntos
Cardiomiopatias , Ablação por Cateter , Coração Auxiliar , Taquicardia Ventricular , Cardiomiopatias/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Recidiva , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 32(3): 647-656, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33428307

RESUMO

AIMS: Catheter ablation (CA) for atrial fibrillation (AF) has a considerable risk of procedural complications. Major vascular complications (MVCs) appear to be the most frequent. This study investigated gender differences in MVCs in patients undergoing CA for AF in a high-volume tertiary center. METHODS: A total of 4734 CAs for AF (65% paroxysmal, 26% repeated procedures) were performed at our center between January 2006 and August 2018. Patients (71% males) aged 60 ± 10 years and had a body mass index of 29 ± 4 kg/m2 at the time of the procedure. Radiofrequency point-by-point ablation was employed in 96.3% of procedures with the use of three-dimensional navigation systems and facilitated by intracardiac echocardiography. Pulmonary vein isolation was mandatory; cavotricuspid isthmus and left atrial substrate ablation were performed in 22% and 38% procedures, respectively. MVCs were defined as those that resulted in permanent injury, required intervention, or prolonged hospitalization. Their rates and risk factors were compared between genders. RESULTS: A total of 112 (2.4%) MVCs were detected: 54/1512 (3.5%) in females and 58/3222 (1.8%) in males (p < .0001). On multivariate analysis, lower body height was the only risk factor for MVCs in females (p = .0005). On the contrary, advanced age was associated with MVCs in males (p = .006). CONCLUSION: Females have a higher risk of MVCs following CA for AF compared to males. This difference is driven by lower body size in females. Low body height in females and advanced age in males are independent predictors of MVCs. Ultrasound-guided venipuncture lowered the MVC rate in males.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Fatores Sexuais , Resultado do Tratamento
7.
Am J Cardiol ; 208: 156-163, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37839172

RESUMO

Plasma natriuretic peptides (NPs) are increased in patients with atrial fibrillation (AF) compared with the patients with sinus rhythm. This study investigated whether this phenomenon is intrinsic to heart rhythm irregularity and independent of the heart rate and left atrial pressure (LAP) overload. We investigated 46 patients (age: 59 ± 10 years, male gender: 77%) with non-valvular paroxysmal AF who were scheduled for catheter ablation and had documented stable sinus rhythm for at least 18 hours before the procedure. All patients underwent direct measurement of right atrial pressure and LAP, simultaneously with assessment of plasma B-type NP, N-terminal pro-brain NP, and mid-regional pro-atrial NP. The baseline measurement was followed by induction of AF by rapid atrial pacing in the first 24 patients and by regular pacing from the coronary sinus at 100/min (corresponding to the mean heart rate during induced AF) in the latter 22 patients. Hemodynamic assessment and blood sampling were repeated after 20 min of the ongoing AF or fast regular paging. The baseline characteristics and hemodynamic measurements were comparable between study groups; however, patients in the regular atrial pacing group had a higher body mass index and a larger left atrial diameter compared with the induced AF group. Plasma levels of all 3 NPs increased significantly during induced AF but not during fast regular pacing, and the increase of NPs was independent of right atrial pressure and LAP. Baseline concentrations of NPs and heart rhythm irregularity were the only independent predictors of increased NPs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Frequência Cardíaca , Pressão Atrial/fisiologia , Peptídeos Natriuréticos , Átrios do Coração , Ablação por Cateter/métodos
8.
JACC Clin Electrophysiol ; 8(7): 895-904, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35863816

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) by radiofrequency (RF) energy is associated with a collateral ganglionated plexi ablation. Pulsed electric field (PEF) is a nonthermal energy source that preferentially affects the myocardial cells and spares neural tissue. OBJECTIVES: This study investigated whether PVI by a PEF compared with RF energy will result in less prominent alteration of the cardiac autonomic nervous system. METHODS: A total of 31 patients with atrial fibrillation underwent PVI using a novel lattice-tip catheter and PEF energy (n = 18) or a conventional irrigated-tip catheter and RF energy (n = 13). The response of the sinoatrial node and atrioventricular node to extracardiac high-frequency, high-output, right vagal nerve stimulation was evaluated at baseline and during and at the end of the ablation procedure. Substantial reduction in responsiveness was arbitrarily defined as stimulation-inducible pause <1.5 seconds. RESULTS: Reduced response of the sinoatrial node was documented in 13 of 13 (100%) and 6 of 18 (33%) patients (P = 0.0001) in RF and PEF groups, respectively. Reduced response of the atrioventricular node was found in 10 of 11 (93%) and 6 of 18 (33%) patients (P = 0.002) in RF and PEF groups, respectively. The major effects were observed predominantly during ablation around the right pulmonary veins. Early recovery of ganglionated plexi function was noticed only in the PEF ablation group. RF ablation resulted in higher acceleration of the sinus rhythm compared with PEF ablation (20 ± 13 beats/min vs 12 ± 10 beats/min; P = 0.04). CONCLUSIONS: PEF compared with RF energy used for PVI induces significantly weaker and less durable suppression of cardiac autonomic regulations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Sistema Nervoso Autônomo , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Nó Sinoatrial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA