Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Syst Synth Biol ; 3(1-4): 19-26, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19816796

RESUMO

We present insights from a study on communicating Synthetic Biology conducted in 2008. Scientists were invited to write press releases on their work; the resulting texts were passed on to four journalists from major Austrian newspapers and magazines. The journalists in turn wrote articles that were used as stimulus material for eight group discussions with select members of the Austrian public. The results show that, from the lab via the media to the general public, communication is characterized by two important tendencies: first, communication becomes increasingly focused on concrete applications of Synthetic Biology; and second, biotechnology represents an important benchmark against which Synthetic Biology is being evaluated.

2.
Indian J Orthop ; 41(4): 374-80, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21139794

RESUMO

UNLABELLED: Polytraumatized patients following a severe trauma suffer from substantial disturbances of the immune system. Secondary organ dysfunction syndromes due to early hyperinflammation and late immunparalysis contribute to adverse outcome. Consequently the principle of damage control surgery / orthopedics developed in the last two decades to limit secondary iatrogenic insult in these patients. New percutaneous internal fixators provide implants for a damage control approach of spinal trauma in polytraumatized patients. The goal of this study is to evaluate the feasibility of minimal-invasive instrumentation in the setting of minor and major trauma and to discuss the potential benefits and drawbacks of this procedure. MATERIALS AND METHODS: The present study is a prospective analysis of 76 consecutive patients (mean age 53.3 years) with thoracolumbar spine fractures following major or minor trauma from August 2003 to January 2007 who were subjected to minimal-invasive dorsal instrumentation using CD Horizon(®) Sextant™ Rod Insertion System and Longitude™ Rod Insertion System (Medtronic(®) Sofamor Danek). Perioperative and postoperative outcome measures including e.g. local and systemic complications were assessed and discussed. RESULTS: Forty-nine patients (64.5%) suffered from minor trauma (Injury Severity Score <16). Polytraumatized patients (n=27; 35.5%) had associated chest (n=20) and traumatic brain injuries (n=22). For mono- and bisegmental dorsal instrumentation the Sextant™ was used in 60 patients, whereas in 16 longer ranging instrumentations the (prototype) Longitude™ system was implanted. Operation time was substantially lower than in conventional approach at minimum 22.5 min for Sextant and 36.2 min for Longitude™, respectively. Geriatric patients with high perioperative risk according to ASA classification benefited from the less invasive approach and lack of approach-related complications including no substantial blood loss. CONCLUSION: Low rate of approach-related complications in association with short operation time and virtually no blood loss is beneficial in the setting of polytraumatized patients regarding damage control orthopedics, as well as in geriatric patients with high perioperative risk. The minimal-invasive instrumentation of the spine is associated with beneficial outcome in a selected patient population.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA