1.
Sensors (Basel) ; 23(2)2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36679484

RESUMO

Few studies have dealt with lower-limb kinematics during the timed up and go (TUG) test in subjects with locomotive syndrome (LS). This study aimed to evaluate the characteristics of lower-limb kinematics during the TUG test in subjects with LS using the wearable sensor-based H-Gait system. A total of 140 participants were divided into the non-LS (n = 28), the LS-stage 1 (n = 78), and LS-stage 2 (n = 34) groups based on the LS risk test. Compared with the non-LS group, the LS-stage 1 and LS-stage 2 groups showed significantly smaller angular velocity of hip and knee extension during the sit-to-stand phase. The LS-stage 2 group showed significantly smaller peak angles of hip extension and flexion during the walking-out phase compared to the non-LS group. These findings indicate that the evaluation of the lower-limb kinematics during the TUG test using the H-Gait system is highly sensitive to detect LS, compared with the evaluation of the lower-limb kinematics when simply walking.


Assuntos
Marcha , Dispositivos Eletrônicos Vestíveis , Humanos , Fenômenos Biomecânicos , Caminhada , Extremidade Inferior
2.
BMC Musculoskelet Disord ; 23(1): 457, 2022 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-35568855

RESUMO

BACKGROUND: Individuals with locomotive syndrome (LS) require nursing care services owing to problems with locomotion and the musculoskeletal system. Individuals with LS generally have a reduced walking speed compared with those without LS. However, differences in lower-limb kinematics and gait between individuals with and without LS are not fully understood. This study aimed to clarify the characteristics of the gait kinematics of individuals with LS using wearable sensors. METHODS: We assessed 125 participants (mean age 73.0 ± 6.7 years) who used a public health promotion facility. Based on the 25-question Geriatric Locomotive Function Scale (GLFS-25), these participants were grouped into the non-LS (GLFS-25 < 7), LS-stage 1 (GLFS-25 7-16), and LS-stage 2 (GLFS-25 ≥ 16) groups (larger GLFS-25 scores indicate worse locomotive ability). Spatiotemporal parameters and lower-limb kinematics during the 10-m walk test were analyzed by the "H-Gait system", which is a motion analysis system that was developed by the authors and is based on seven inertial sensors. The peak joint angles during the stance and swing phases, as well as the gait speed, cadence, and step length were compared among all groups. RESULTS: There were 69 participants in the non-LS group, 33 in the LS-stage 1 group, and 23 in the LS-stage 2 group. Compared with the non-LS group, the LS-stage 2 group showed significantly smaller peak angles of hip extension (9.5 ± 5.3° vs 4.2 ± 8.2°, P = 0.002), hip flexion (34.2 ± 8.8° vs 28.5 ± 9.5°, P = 0.026), and knee flexion (65.2 ± 18.7° vs 50.6 ± 18.5°, P = 0.005). The LS-stage 1 and LS-stage 2 groups had a significantly slower mean gait speed than the non-LS group (non-LS: 1.3 ± 0.2 m/s, LS-stage 1: 1.2 ± 0.2 m/s, LS-stage 2: 1.1 ± 0.2 m/s, P < 0.001). CONCLUSIONS: The LS-stage 2 group showed significantly different lower-limb kinematics compared with the non-LS group, including smaller peak angles of hip extension, hip flexion, and knee flexion. It would be useful to assess and improve these small peak joint angles during gait for individuals classified as LS-stage 2.


Assuntos
Marcha , Dispositivos Eletrônicos Vestíveis , Idoso , Fenômenos Biomecânicos , Humanos , Locomoção , Síndrome , Velocidade de Caminhada
3.
BMC Musculoskelet Disord ; 22(1): 46, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33419416

RESUMO

BACKGROUND: Hip osteoarthritis (OA) is a musculoskeletal condition that makes walking difficult due to pain induced by weight-bearing activities. Treadmills that support the body weight (BW) reduce the load on the lower limbs, and those equipped with a lower-body positive-pressure (LBPP) device, developed as a new method for unweighting, significantly reduce pain in patients with knee OA. However, the effects of unweighting on gait kinematics remain unclear in patients with hip OA. Therefore, we investigated the effects of unweighting on kinematics in patients with hip OA during walking on a treadmill equipped with an LBPP device. METHODS: A total of 15 women with hip OA and 15 age-matched female controls wore a three-dimensional (3-D) motion analysis system and walked at a self-selected speed on the LBPP treadmill. Data regarding self-reported hip pain using a numeric rating scale (NRS) in which the scores 0 and 10 represented no pain and the worst pain, respectively, under three different BW conditions (100, 75, and 50%) were collected. Moreover, 3-D peak joint angles during gait under each condition were calculated and compared. RESULTS: In the hip OA group, the NRS pain scores at 50 and 75% BW conditions significantly decreased compared with that at 100% BW condition (50%, P = 0.002; 75%, P = 0.026), and the peak hip extension angle decreased compared with that in the healthy controls (P = 0.044). In both groups, unweighting significantly decreased the peak hip (P < 0.001) and knee (P < 0.001) flexion angles and increased the peak ankle plantar flexion angle (P < 0.001) during walking. CONCLUSIONS: Unweighting by the LBPP treadmill decreased pain in the hip OA group but did not drastically alter the gait kinematics compared with that in the control group. Therefore, regarding the use of the LBPP treadmill for patients with hip OA, clinicians should consider the benefits of pain reduction rather than the kinematic changes.


Assuntos
Osteoartrite do Quadril , Osteoartrite do Joelho , Fenômenos Biomecânicos , Feminino , Marcha , Humanos , Articulação do Joelho , Osteoartrite do Quadril/diagnóstico , Osteoartrite do Joelho/diagnóstico , Caminhada
4.
Sensors (Basel) ; 21(8)2021 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-33917951

RESUMO

Recently, treadmills equipped with a lower-body positive-pressure (LBPP) device have been developed to provide precise body weight support (BWS) during walking. Since lower limbs are covered in a waist-high chamber of an LBPP treadmill, a conventional motion analysis using an optical method is impossible to evaluate gait kinematics on LBPP. We have developed a wearable-sensor-based three-dimensional motion analysis system, H-Gait. The purpose of the present study was to investigate the effects of BWS by a LBPP treadmill on gait kinematics using an H-Gait system. Twenty-five healthy subjects walked at 2.5 km/h on a LBPP treadmill under the following three conditions: (1) 0%BWS, (2) 25%BWS and (3) 50%BWS conditions. Acceleration and angular velocity from seven wearable sensors were used to analyze lower limb kinematics during walking. BWS significantly decreased peak angles of hip adduction, knee adduction and ankle dorsiflexion. In particular, the peak knee adduction angle at the 50%BWS significantly decreased compared to at the 25%BWS (p = 0.012) or 0%BWS (p < 0.001). The present study showed that H-Gait system can detect the changes in gait kinematics in response to BWS by a LBPP treadmill and provided a useful clinical application of the H-Gait system to walking exercises.


Assuntos
Marcha , Caminhada , Fenômenos Biomecânicos , Teste de Esforço , Humanos , Articulação do Joelho
5.
BMC Musculoskelet Disord ; 20(1): 155, 2019 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-30961554

RESUMO

BACKGROUND: Lumbar traction is a traditional treatment modality for chronic low back pain (CLBP) in many countries. However, its effectiveness has not been demonstrated in clinical practice because of the following: (1) the lack of in vivo biomechanical confirmation of the mechanism of lumbar traction that occurs at the lumbar spine; (2) the lack of a precise delivery system for traction force and, subsequently, the lack of reproducibility; and (3) few randomized controlled trials proving its effectiveness and utility. METHODS: This study was planned as a preparatory experiment for a randomized clinical trial, and it aimed (1) to examine the biomechanical change at the lumbar area under lumbar traction and confirm its reproducibility and accuracy as a mechanical intervention, and (2) to reconfirm our clinical impression of the immediate effect of lumbar traction. One hundred thirty-three patients with non-specific CLBP were recruited from 28 orthopaedic clinics to undergo a biomechanical experiment and to assess and determine traction conditions for the next clinical trial. We used two types of traction devices, which are commercially available, and incorporated other measuring tools, such as an infrared range-finder and large extension strain gauge. The finite element method was used to analyze the real data of pelvic girdle movement at the lumbar spine level. Self-report assessments with representative two conditions were analyzed according to the qualitative coding method. RESULTS: Thirty-eight participants provided available biomechanical data. We could not measure directly what happened in the body, but we confirmed that the distraction force lineally correlated with the movement of traction unit at the pelvic girdle. After applying vibration force to preloading, the strain gauge showed proportional vibration of the shifting distance without a phase lag qualitatively. FEM simulation provided at least 3.0-mm shifting distance at the lumbar spine under 100 mm of body traction. Ninety-five participants provided a treatment diary and were classified as no pain, improved, unchanged, and worsened. Approximately 83.2% of participants reported a positive response. CONCLUSION: Lumbar traction can provide a distractive force at the lumbar spine, and patients who experience the application of such force show an immediate response after traction. TRIAL REGISTRATION: University Hospital Medical Information Network - Clinical Trial Registration: UMIN-CTR000024329 (October 13, 2016).


Assuntos
Dor Lombar/diagnóstico , Dor Lombar/terapia , Vértebras Lombares/fisiologia , Tração/instrumentação , Tração/métodos , Adulto , Fenômenos Biomecânicos/fisiologia , Feminino , Humanos , Dor Lombar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Autorrelato , Resultado do Tratamento
6.
Sensors (Basel) ; 19(19)2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31547181

RESUMO

Wearable sensors are de facto revolutionizing the assessment of standing balance. The aim of this work is to review the state-of-the-art literature that adopts this new posturographic paradigm, i.e., to analyse human postural sway through inertial sensors directly worn on the subject body. After a systematic search on PubMed and Scopus databases, two raters evaluated the quality of 73 full-text articles, selecting 47 high-quality contributions. A good inter-rater reliability was obtained (Cohen's kappa = 0.79). This selection of papers was used to summarize the available knowledge on the types of sensors used and their positioning, the data acquisition protocols and the main applications in this field (e.g., "active aging", biofeedback-based rehabilitation for fall prevention, and the management of Parkinson's disease and other balance-related pathologies), as well as the most adopted outcome measures. A critical discussion on the validation of wearable systems against gold standards is also presented.


Assuntos
Doença de Parkinson/fisiopatologia , Equilíbrio Postural/fisiologia , Dispositivos Eletrônicos Vestíveis , Acidentes por Quedas , Humanos
7.
Sensors (Basel) ; 19(19)2019 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-31569372

RESUMO

Overweight/obesity is a physical condition that affects daily activities, including walking. The main purpose of this study was to identify if there is a relationship between body mass index (BMI) and gait characteristics in young adults. 12 normal weight (NW) and 10 overweight/obese (OW) individuals walked at a self-selected speed along a 14 m indoor path. H-Gait system, combining seven inertial sensors (fixed on pelvis and lower limbs), was used to record gait data. Walking speed, spatio-temporal parameters and joint kinematics in 3D were analyzed. Differences between NW and OW and correlations between BMI and gait parameters were evaluated. Conventional spatio-temporal parameters did not show statistical differences between the two groups or correlations with the BMI. However, significant results were pointed out for the joint kinematics. OW showed greater hip joint angles in frontal and transverse planes, with respect to NW. In the transverse plane, OW showed a greater knee opening angle and a shorter length of knee and ankle trajectories. Correlations were found between BMI and kinematic parameters in the frontal and transverse planes. Despite some phenomena such as soft tissue artifact and kinematics cross-talk, which have to be more deeply assessed, current results show a relationship between BMI and gait characteristics in young adults that should be looked at in osteoarthritis prevention.


Assuntos
Índice de Massa Corporal , Marcha/fisiologia , Monitorização Fisiológica/instrumentação , Sobrepeso , Adulto , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/fisiologia , Masculino , Monitorização Fisiológica/métodos , Sobrepeso/fisiopatologia , Análise Espaço-Temporal , Caminhada/fisiologia
8.
Sensors (Basel) ; 17(10)2017 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-29065485

RESUMO

Background: Wearable magneto-inertial sensors are being increasingly used to obtain human motion measurements out of the lab, although their performance in applications requiring high accuracy, such as gait analysis, are still a subject of debate. The aim of this work was to validate a gait analysis system (H-Gait) based on magneto-inertial sensors, both in normal weight (NW) and overweight/obese (OW) subjects. The validation is performed against a reference multichannel recording system (STEP32), providing direct measurements of gait timings (through foot-switches) and joint angles in the sagittal plane (through electrogoniometers). Methods: Twenty-two young male subjects were recruited for the study (12 NW, 10 OW). After positioning body-fixed sensors of both systems, each subject was asked to walk, at a self-selected speed, over a 14-m straight path for 12 trials. Gait signals were recorded, at the same time, with the two systems. Spatio-temporal parameters, ankle, knee, and hip joint kinematics were extracted analyzing an average of 89 ± 13 gait cycles from each lower limb. Intraclass correlation coefficient and Bland-Altmann plots were used to compare H-Gait and STEP32 measurements. Changes in gait parameters and joint kinematics of OW with respect NW were also evaluated. Results: The two systems were highly consistent for cadence, while a lower agreement was found for the other spatio-temporal parameters. Ankle and knee joint kinematics is overall comparable. Joint ROMs values were slightly lower for H-Gait with respect to STEP32 for the ankle (by 1.9° for NW, and 1.6° for OW) and for the knee (by 4.1° for NW, and 1.8° for OW). More evident differences were found for hip joint, with ROMs values higher for H-Gait (by 6.8° for NW, and 9.5° for OW). NW and OW showed significant differences considering STEP32 (p = 0.0004), but not H-Gait (p = 0.06). In particular, overweight/obese subjects showed a higher cadence (55.0 vs. 52.3 strides/min) and a lower hip ROM (23.0° vs. 27.3°) than normal weight subjects. Conclusions: The two systems can be considered interchangeable for what concerns joint kinematics, except for the hip, where discrepancies were evidenced. Differences between normal and overweight/obese subjects were statistically significant using STEP32. The same tendency was observed using H-Gait.


Assuntos
Biofísica/instrumentação , Peso Corporal , Marcha , Dispositivos Eletrônicos Vestíveis/normas , Adulto , Fenômenos Biomecânicos , Articulação do Quadril/fisiologia , Humanos , Articulação do Joelho/fisiologia , Magnetismo , Masculino , Obesidade , Sobrepeso , Caminhada
9.
Sensors (Basel) ; 14(12): 23230-47, 2014 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-25490587

RESUMO

Accumulated signal noise will cause the integrated values to drift from the true value when measuring orientation angles of wearable sensors. This work proposes a novel method to reduce the effect of this drift to accurately measure human gait using wearable sensors. Firstly, an infinite impulse response (IIR) digital 4th order Butterworth filter was implemented to remove the noise from the raw gyro sensor data. Secondly, the mode value of the static state gyro sensor data was subtracted from the measured data to remove offset values. Thirdly, a robust double derivative and integration method was introduced to remove any remaining drift error from the data. Lastly, sensor attachment errors were minimized by establishing the gravitational acceleration vector from the acceleration data at standing upright and sitting posture. These improvements proposed allowed for removing the drift effect, and showed an average of 2.1°, 33.3°, 15.6° difference for the hip knee and ankle joint flexion/extension angle, when compared to without implementation. Kinematic and spatio-temporal gait parameters were also calculated from the heel-contact and toe-off timing of the foot. The data provided in this work showed potential of using wearable sensors in clinical evaluation of patients with gait-related diseases.


Assuntos
Actigrafia/instrumentação , Algoritmos , Artefatos , Marcha/fisiologia , Monitorização Ambulatorial/instrumentação , Transdutores , Actigrafia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Perna (Membro)/fisiologia , Monitorização Ambulatorial/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
10.
Sensors (Basel) ; 13(7): 9321-43, 2013 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-23877128

RESUMO

This paper proposes a method for three dimensional gait analysis using wearable sensors and quaternion calculations. Seven sensor units consisting of a tri-axial acceleration and gyro sensors, were fixed to the lower limbs. The acceleration and angular velocity data of each sensor unit were measured during level walking. The initial orientations of the sensor units were estimated using acceleration data during upright standing position and the angular displacements were estimated afterwards using angular velocity data during gait. Here, an algorithm based on quaternion calculation was implemented for orientation estimation of the sensor units. The orientations of the sensor units were converted to the orientations of the body segments by a rotation matrix obtained from a calibration trial. Body segment orientations were then used for constructing a three dimensional wire frame animation of the volunteers during the gait. Gait analysis was conducted on five volunteers, and results were compared with those from a camera-based motion analysis system. Comparisons were made for the joint trajectory in the horizontal and sagittal plane. The average RMSE and correlation coefficient (CC) were 10.14 deg and 0.98, 7.88 deg and 0.97, 9.75 deg and 0.78 for the hip, knee and ankle flexion angles, respectively.


Assuntos
Acelerometria/instrumentação , Algoritmos , Técnicas Biossensoriais/instrumentação , Marcha/fisiologia , Imageamento Tridimensional/instrumentação , Perna (Membro)/fisiologia , Monitorização Ambulatorial/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
11.
J Biomech Eng ; 134(5): 054502, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22757497

RESUMO

Scoliosis is defined as a spinal pathology characterized as a three-dimensional deformity of the spine combined with vertebral rotation. Treatment for severe scoliosis is achieved when the scoliotic spine is surgically corrected and fixed using implanted rods and screws. Several studies performed biomechanical modeling and corrective forces measurements of scoliosis correction. These studies were able to predict the clinical outcome and measured the corrective forces acting on screws, however, they were not able to measure the intraoperative three-dimensional geometry of the spinal rod. In effect, the results of biomechanical modeling might not be so realistic and the corrective forces during the surgical correction procedure were intra-operatively difficult to measure. Projective geometry has been shown to be successful in the reconstruction of a three-dimensional structure using a series of images obtained from different views. In this study, we propose a new method to measure the three-dimensional geometry of an implant rod using two cameras. The reconstruction method requires only a few parameters, the included angle θ between the two cameras, the actual length of the rod in mm, and the location of points for curve fitting. The implant rod utilized in spine surgery was used to evaluate the accuracy of the current method. The three-dimensional geometry of the rod was measured from the image obtained by a scanner and compared to the proposed method using two cameras. The mean error in the reconstruction measurements ranged from 0.32 to 0.45 mm. The method presented here demonstrated the possibility of intra-operatively measuring the three-dimensional geometry of spinal rod. The proposed method could be used in surgical procedures to better understand the biomechanics of scoliosis correction through real-time measurement of three-dimensional implant rod geometry in vivo.


Assuntos
Próteses e Implantes , Escoliose/cirurgia , Humanos , Período Intraoperatório , Fenômenos Mecânicos , Modelos Teóricos , Coluna Vertebral/cirurgia
12.
J Orthop Sci ; 17(3): 253-60, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22323013

RESUMO

BACKGROUND: The distribution of subchondral bone density well reflects long-term resultant stress acting on an articular surface in living joints. Consequently, a measurement of the distribution pattern can determine the stress distribution across the elbow joint surface under long-term loading conditions of baseball pitching. Our purpose was to elucidate the characteristic alterations in the distribution pattern of subchondral bone density across the forearm bones of the elbow with pitching activities. The hypothesis is that pitching activities would change the stress distribution in living subjects. METHODS: The analysis was performed using computed tomography (CT) images obtained from the dominant elbow of ten nonthrowing athletes (control group), ten college baseball fielders (fielder group), and ten college baseball pitchers (pitcher group). The distribution pattern of subchondral bone density through the articular surface of the proximal radius and ulna bones was assessed using CT osteoabsorptiometry. RESULTS: The maximum density area was located in the posterior part of the trochlea notch in all study participants. This maximum density area was significantly increased in the baseball groups compared with that in the control group. The pitcher group also showed a significant distribution of the maximum density area in the anterior part of the radial head. CONCLUSION: Our analysis indicates that pitching activities increase actual stress on the articular surface not only in the posterior part of the trochlea notch but also in the anterior part of the radial head. The stress across the elbow may be expanded from the ulnohumeral to the radiohumeral joint by repetitive pitching activities in living subjects.


Assuntos
Beisebol/fisiologia , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiologia , Estresse Mecânico , Tomografia Computadorizada Espiral , Fenômenos Biomecânicos , Antebraço , Humanos , Masculino , Adulto Jovem
13.
Med Eng Phys ; 105: 103823, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35781387

RESUMO

This study aims to describe the geometrical features of single trabeculae and their network to explain cancellous stiffness as a representative mechanical function from a strength of materials perspective. Compression tests were performed on cancellous bone specimens dissected from a bovine femur as 5-mm cubes to measure cancellous stiffness. The microarchitecture was determined by microfocus X-ray computed tomography, and conventional morphological indicators were analyzed. The length, orientation, and bifurcation characteristics of each trabecula were analyzed by skeletonizing and linearizing the cancellous bone volume. Multiple regression analyses revealed a significant contribution made to cancellous stiffness by the compressive shape factor of the stiffness of single trabeculae, the trabecular orientation, and the bifurcation count, which evaluated the mean number of connected trabeculae at bifurcation points. Bifurcation count made the most significant contribution to cancellous stiffness. The combination of these geometrical indicators expressed the cancellous stiffness (R2 = 0.85), which indicated as high accuracy as that explained by bone volume fraction, in specific bones that were not affected by bone disease or aging. The present study demonstrated mechanically important geometrical features of the microarchitecture and indicated their complex contributions to cancellous stiffness underlying the contribution of bone volume fraction.


Assuntos
Osso e Ossos , Fêmur , Animais , Bovinos , Artéria Femoral , Fêmur/diagnóstico por imagem , Extremidade Inferior , Tomografia Computadorizada por Raios X
14.
J Biomech Eng ; 133(12): 124503, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22206430

RESUMO

There may be different causes of failures in bone; however, their origin generally lies at the lowest level of structural hierarchy, i.e., at the mineral-collagen composite. Any change in the nanostructure affects the affinity or bonding effectiveness between and within the phases at this level, and hence determines the overall strength and quality of bone. In this study, we propose a novel concept to assess change in the nanostructure and thereby change in the bonding status at this level by revealing change in the orientation distribution characteristics of mineral crystals. Using X-ray diffraction method, a parameter called Degree of Orientation (DO) has been quantified. The DO accounts for the azimuthal distribution of mineral crystals and represents their effective amount along any direction. Changes in the DOs in cortical bone samples from bovine femur with different preferential orientations of mineral crystals were estimated under external loads. Depending on the applied loads, change in the azimuthal distribution of the DOs and the degree of reversibility of the crystals was observed to vary. The characteristics of nanostructural change and thereby possible affect on the strength of bone was then predicted from the reversible or irreversible characteristics of distributed mineral crystals. Significant changes in the organization of mineral crystals were observed; however, variations in the applied stresses and elastic moduli were not evinced at the macroscale level. A novel concept to assess the alteration in nanostructure on the basis of mineral crystals orientation distribution has been proposed. The importance of nanoscale level information obtained noninvasively has been emphasized, which acts as a precise tool to estimate the strength and predict the possible fracture risks in bone.


Assuntos
Fêmur/química , Fêmur/metabolismo , Fraturas Ósseas/metabolismo , Minerais/química , Minerais/metabolismo , Nanoestruturas/química , Animais , Bovinos , Medição de Risco , Difração de Raios X
15.
J Hand Surg Am ; 36(7): 1158-64, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21664073

RESUMO

PURPOSE: The distribution pattern of subchondral bone density is considered to closely reflect the stress distribution across a joint under physiological loading conditions. Our purpose was to determine alterations in the distribution pattern of subchondral bone density across the distal articular surfaces of the radius and the ulna in patients with Kienböck disease after radial shortening. METHODS: We collected preoperative and postoperative computed tomography (CT) image data from 7 wrists of 7 patients who had undergone radial shortening for Kienböck disease. We measured the distribution of subchondral bone density through the distal articular surface of the radius and the ulna using a CT osteoabsorptiometry method. The obtained data were quantitatively assessed by calculating the high-density area ratio of the entire radiocarpal joint surface, scaphoid fossa, lunate fossa, and distal ulnar surface. RESULTS: At the mean postoperative period of 27 months, the mean high-density area ratio in the entire distal articular surface of the radius significantly decreased from 0.413 preoperatively to 0.141 postoperatively. The postoperative value in each fossa demonstrated a significant reduction from 0.253 to 0.096 in the scaphoid fossa and from 0.160 to 0.045 in the lunate fossa. No significant alteration in the value was found in the distal ulna at follow-up. CONCLUSIONS: Our CT osteoabsorptiometry analysis suggests that the distribution of subchondral bone density in both scaphoid and lunate fossae notably decreases after radial shortening. This indicates that radial shortening unloads the lunate by reducing the actual stress across the distal articular surface of the radius in subjects with Kienböck disease. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Osteonecrose/diagnóstico por imagem , Osteonecrose/cirurgia , Osteotomia/métodos , Rádio (Anatomia)/cirurgia , Amplitude de Movimento Articular/fisiologia , Absorciometria de Fóton/métodos , Adolescente , Adulto , Feminino , Seguimentos , Força da Mão/fisiologia , Humanos , Masculino , Cuidados Pós-Operatórios/métodos , Cuidados Pré-Operatórios/métodos , Rádio (Anatomia)/diagnóstico por imagem , Estudos de Amostragem , Índice de Gravidade de Doença , Estresse Mecânico , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia , Adulto Jovem
16.
Sci Technol Adv Mater ; 12(6): 064708, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27877458

RESUMO

To understand the characteristics of bone at the tissue level, the structure, organization and mechanical properties of the underlying levels down to the nanoscale as well as their mutual interactions need to be investigated. Such information would help understand changes in the bone properties including stiffness, strength and toughness and provide ways to assess the aged and diseased bones and the development of next generation of bio-inspired materials. X-ray diffraction techniques have gained increased interest in recent years as useful non-destructive tools for investigating the nanostructure of bone. This review provides an overview on the recent progress in this field and briefly introduces the related experimental approach. The application of x-ray diffraction to elucidating the structural and mechanical properties of mineral crystals in bone is reviewed in terms of characterization of in situ strain, residual stress-strain and crystal orientation.

17.
J Biomech Eng ; 132(3): 031004, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20459192

RESUMO

Measurement of the stress and strain applied to implants and bone tissue in the human body are important for fracture prediction and evaluations of implant adaptation. The strain of titanium (Ti) materials can be measuring by X-ray diffraction techniques. This study applied X-ray diffraction to the skin tissue-covered Ti. Characteristic X-rays of Mo Kalpha were used and the X-rays diffracted from the Ti were detected through the covering skin tissue. The X-ray absorption by skin tissue is large under the diffracted X-rays detected in low angles because the length of penetration depends on the angle of inclination, equal to the Bragg angle. The effects of skin tissue to detect the diffracted X-rays were investigated in the experiments. And the strain measurements were conducted under bending loads applied to the Ti specimen. The effect of skin tissue was absorption of X-rays as well as the X-rays scattered from the physiological saline contained in the tissue. The X-rays scattered by the physiological saline creates a specific background pattern near the peaks from the (002) and (011) lattice planes of Ti in the X-ray diffraction profile. Diffracted X-rays from the Ti were detected after being transmitted through 1 mm thick skin tissue by Mo Kalpha. Individual peaks such as (010), (002), (011), and (110) were clearly established by using a parallel beam arrangement. The strains of (110) lattice planes were measured with or without the tissue cover were very similar. The strain of the (110) lattice planes of Ti could be measured by Mo Kalpha when the Ti specimen was located under the skin tissue.


Assuntos
Materiais Biocompatíveis/química , Tecido Conjuntivo/fisiologia , Próteses e Implantes , Titânio/química , Animais , Tecido Conjuntivo/cirurgia , Módulo de Elasticidade , Análise de Falha de Equipamento , Teste de Materiais , Coelhos , Estresse Mecânico , Difração de Raios X/métodos
18.
J Biomech Eng ; 132(4): 044503, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20387976

RESUMO

Residual stress in living tissue plays an important role in mechanical strength. We have reported that residual stress exists in the bone tissue of a rabbit's tibiofibula. The purpose of this study is to measure the residual stress around the outer cortical region of bovine femoral diaphysis and to discuss the distribution of the stress. This work proposed the sin(2) psi method of X-ray diffraction to the measurement of residual stresses in bone tissue. In this method, residual stress can be estimated from the variation in the interplanar spacings orientated to a number of directions without the lattice strain in the stress direction. Four-point bending tests of strip specimens taken from bovine femoral diaphysis were carried out during X-ray irradiation in advance. In the proximal, middle, and distal sections of bovine femoral diaphyses, the residual stresses at the cortical surface were measured using characteristic Mo-Kalpha X-rays. The bending tests of strip specimens with X-ray irradiation showed that the method could reliably estimate residual stresses in the bone tissue. The residual stress of the bone axial direction was larger than that of the circumferential direction. The stresses in the middle part of five diaphyses along the bone axial direction were tensile. The maximum stress was 162 MPa at the lateral position and the minimum was 78 MPa at the posterior position. The residual stress in the bone axial direction varies around the circumferential region. In addition, the bone axial distributions of residual stresses were different in the proximal, middle, and distal sections of the individual femur. Furthermore, it was confirmed that residual stress in the bone tissue was released by the cutting out of the specimen. The residual stresses in bone tissue could be measured by this method. The results show that residual stress in the bone axial direction at the cortical surface in bovine femoral diaphysis is tensile and varies around the circumferential region.


Assuntos
Fêmur/fisiologia , Modelos Biológicos , Animais , Anisotropia , Bovinos , Simulação por Computador , Diáfises/fisiologia , Módulo de Elasticidade , Estresse Mecânico
19.
J Biomech ; 42(3): 223-33, 2009 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-19121522

RESUMO

A novel method for measuring human gait posture using wearable sensor units is proposed. The sensor units consist of a tri-axial acceleration sensor and three gyro sensors aligned on three axes. The acceleration and angular velocity during walking were measured with seven sensor units worn on the abdomen and the lower limb segments (both thighs, shanks and feet). The three-dimensional positions of each joint are calculated from each segment length and joint angle. Joint angle can be estimated mechanically from the gravitational acceleration along the anterior axis of the segment. However, the acceleration data during walking includes three major components; translational acceleration, gravitational acceleration and external noise. Therefore, an optimization analysis was represented to separate only the gravitational acceleration from the acceleration data. Because the cyclic patterns of acceleration data can be found during constant walking, a FFT analysis was applied to obtain some characteristic frequencies in it. A pattern of gravitational acceleration was assumed using some parts of these characteristic frequencies. Every joint position was calculated from the pattern under the condition of physiological motion range of each joint. An optimized pattern of the gravitational acceleration was selected as a solution of an inverse problem. Gaits of three healthy volunteers were measured by walking for 20s on a flat floor. As a result, the acceleration data of every segment was measured simultaneously. The characteristic three-dimensional walking could be shown by the expression using a stick figure model. In addition, the trajectories of the knee joint in the horizontal plane could be checked by visual imaging on a PC. Therefore, this method provides important quantitive information for gait diagnosis.


Assuntos
Algoritmos , Marcha/fisiologia , Adulto , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos/fisiologia , Engenharia Biomédica/instrumentação , Feminino , Humanos , Articulação do Joelho/fisiologia , Masculino , Movimento (Física)
20.
Clin Biomech (Bristol, Avon) ; 65: 13-18, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30928786

RESUMO

BACKGROUND: Since bone mass is not the only determinant of bone strength, there has been increasing interest in incorporating the bone quality into fracture risk assessments. We aimed to examine whether the magnetic resonance imaging (MRI) T1 or T2 mapping value could provide information that is complementary to bone mineral density for more accurate prediction of cancellous bone strength. METHODS: Four postmenopausal women with hip osteoarthritis underwent 3.0-T MRI to acquire the T1 and T2 values of the cancellous bone of the femoral head before total hip arthroplasty. After the surgery, the excised femoral head was portioned into multiple cubic cancellous bone specimens with side of 5 mm, and the specimens were then subjected to microcomputed tomography followed by biomechanical testing. FINDINGS: The T1 value positively correlated with the yield stress (σy) and collapsed stress (σc). The T2 value did not correlate with the yield stress, but it correlated with the collapsed stress and strength reduction ratio (σc/σy), which reflects the progressive re-fracture risk. Partial correlation coefficient analyses, after adjusting for the bone mineral density, showed a statistically significant correlation between T1 value and yield stress. The use of multiple coefficients of determination by least squares analysis emphasizes the superiority of combining the bone mineral density and the MRI mapping values in predicting the cancellous bone strength compared with the bone mineral density-based prediction alone. INTERPRETATION: The MRI T1 and T2 values predict cancellous bone strength including the change in bone quality.


Assuntos
Densidade Óssea , Cabeça do Fêmur/diagnóstico por imagem , Imageamento por Ressonância Magnética , Osteoartrite do Quadril/diagnóstico por imagem , Osteoporose Pós-Menopausa/diagnóstico por imagem , Idoso , Artroplastia de Quadril , Fenômenos Biomecânicos , Osso Esponjoso/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Pós-Menopausa , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA