Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Gastroenterol Hepatol ; 22(2): 271-282.e3, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37743040

RESUMO

BACKGROUND & AIMS: Reported rates of delayed bleeding (DB) after endoscopic resection using direct oral anticoagulants (DOACs) are high and heterogeneous. This large-scale multicenter study analyzed cases of DB after colorectal endoscopic submucosal dissection related to various types of DOACs in Japan (the ABCD-J study) with those associated with warfarin. METHODS: We retrospectively reviewed 1019 lesions in patients treated with DOACs and 459 lesions in patients treated with warfarin among 34,455 endoscopic submucosal dissection cases from 47 Japanese institutions between 2012 and 2021. The DB rate (DBR) with each DOAC was compared with that with warfarin. Risk factors for DB in patients treated with DOACs or warfarin were also investigated. RESULTS: The mean tumor sizes in the DOAC and warfarin groups were 29.6 ± 14.0 and 30.3 ± 16.4 mm, respectively. In the DOAC group, the DBR with dabigatran (18.26%) was significantly higher than that with apixaban (10.08%, P = .029), edoxaban (7.73%, P = .001), and rivaroxaban (7.21%, P < .001). Only rivaroxaban showed a significantly lower DBR than warfarin (11.76%, P = .033). In the multivariate analysis, heparin bridging therapy (odds ratio [OR], 2.18; 95% confidence interval [CI], 1.27-3.73, P = .005), rectal location (2.01, 1.28-3.16, P = .002), and procedure time ≥55 minutes (2.43, 1.49-3.95, P < .001) were significant risk factors for DB in the DOAC group. The DB risk in the DOAC group (OR, (95% CI)) was 2.13 (1.30-3.50) and 4.53 (2.52-8.15) for 1 and 2 significant risk factors, respectively. CONCLUSIONS: Dabigatran was associated with a higher DBR than other DOACs, and only rivaroxaban was associated with a significantly lower DBR than warfarin.


Assuntos
Fibrilação Atrial , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Varfarina , Rivaroxabana/efeitos adversos , Dabigatrana/efeitos adversos , Japão , Ressecção Endoscópica de Mucosa/efeitos adversos , Estudos Retrospectivos , Hemorragia/induzido quimicamente , Anticoagulantes , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/complicações , Administração Oral , Fibrilação Atrial/complicações
2.
Jpn J Clin Oncol ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762330

RESUMO

Colonoscopy is the gold standard for detecting and resecting adenomas or early stage cancers to reduce the incidence and mortality rates of colorectal cancer. In a recent observational study, texture and color enhancement imaging (TXI) was reported to improve polyp detection during colonoscopy. This randomized controlled trial involving six Japanese institutions aims to confirm the superiority of TXI over standard white-light imaging (WLI) in detecting colorectal lesions during colonoscopy. During the 1-year study period, 960 patients will be enrolled, with 480 patients in the TXI and WLI groups. The primary endpoint is the mean number of adenomas detected per procedure. The secondary endpoints include adenoma detection rate, advanced adenoma detection rate, polyp detection rate, flat polyp detection rate, depressed lesion detection rate, mean polyps detected per procedure, sessile serrated lesion (SSL) detection rate, mean SSLs detected per procedure and adverse events.

3.
Nano Lett ; 23(24): 11548-11554, 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38063468

RESUMO

Single-photon emissions from individual emitters are crucial in fundamental science and quantum information technologies. Multichromophoric systems, comprising multiple dyes, can exhibit single-photon emissions through efficient annihilation between the excited states; however, exploring this phenomenon in complex systems remains a challenge. In this study, we investigated the photon statistics of emissions from multiple perylene bisimide (PBI) dyes adsorbed onto the surface of CdSe/ZnS quantum dots (QDs). When multiple PBIs were simultaneously excited by both direct excitation and energy transfer from the QD, multiphoton emissions from the PBIs were observed. Conversely, when the QDs were selectively excited, multiple PBIs exhibiting single-photon emission through energy transfer from the QDs to the PBIs were found. These results highlight the intriguing interplay between multichromophoric systems and QDs, offering valuable insights into the development of efficient single-photon sources in quantum information technologies.

4.
BMC Gastroenterol ; 23(1): 389, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37957560

RESUMO

BACKGROUND: Texture and color enhancement imaging (TXI) enhances the changes in endoscopic features caused by gastric neoplasms, such as redness/whiteness and elevation/depression. This study aimed to demonstrate the effectiveness of TXI in improving the visibility of gastric neoplasms compared with white light imaging (WLI) using conventional (CE) and newly developed endoscopes (NE). METHODS: We recruited patients who were histologically diagnosed with gastric neoplasms; endoscopy was performed, and gastric neoplasms photographed using three imaging modalities, including WLI, TXI mode 1 (TXI-1) and TXI mode 2 (TXI-2). Two different endoscopes (CE and NE) were used for the same patients. Six endoscopists provided the visibility scale scores ranging from 1 (poor) to 4 (excellent) for gastric neoplasms. The primary outcome was the visibility scale scores based on each modality and endoscope. The secondary outcome was the identification of factors including H. pylori infection, atrophy, location, size, morphology, histological diagnosis and intestinal metaplasia that affect the differences in visibility scale scores between TXI-1/TXI-2 and WLI. RESULTS: Fifty-two gastric neoplasms were analyzed. The mean visibility scale scores with the NE were 2.79 ± 1.07, 3.23 ± 0.96 and 3.14 ± 0.92 for WLI, TXI-1 and TXI-2, respectively. The mean visibility scales with the CE were 2.53 ± 1.10, 3.04 ± 1.05 and 2.96 ± 1.92 for WLI, TXI-1 and TXI-2, respectively. For both endoscopes, significant differences were observed in visibility scale scores between WLI and TXI-1 (p < 0.001) and between WLI and TXI-2 (p < 0.001). The visibility scale scores of NE were superior to those of CE in all modalities. In the secondary outcome, there was no factor affected the differences of visibility scale scores between TXI-1/TXI-2 and WLI. CONCLUSIONS: This study demonstrated that TXI-1 and TXI-2 enhanced the visibility scale scores of gastric neoplasms compared with that of WLI. Moreover, newly developed endoscope has the potential to improve visibility compared to conventional endoscope. TRIAL REGISTRATION: This study was registered with the University Hospital Medical Information Network (UMIN000042429, 16/11/2020).


Assuntos
Endoscopia Gastrointestinal , Aumento da Imagem , Neoplasias Gástricas , Humanos , Endoscópios , Endoscopia Gastrointestinal/métodos , Aumento da Imagem/métodos , Luz , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia
5.
Dig Endosc ; 35(4): 529-537, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36398944

RESUMO

OBJECTIVES: We aimed to evaluate the efficacy of texture and color enhancement imaging (TXI), which allows the acquisition of brighter images with enhanced color and surface structure in colorectal polyp detection compared to white light imaging. METHODS: Patients who underwent colonoscopy with repeated ascending colon observation using TXI and white light imaging between August 2020 and January 2021 were identified in three institutions. The outcomes included the mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and ascending colonic adenoma miss rate (Ac-AMR). Logistic regression was used to determine the effects of the variables on the outcomes. RESULTS: We included 1043 lesions from 470 patients in the analysis. The MAP, ADR, flat polyp detection rate, and Ac-AMR in TXI and white light imaging were 1.5% (95% confidence interval 1.3-1.6%) vs. 1.0% (0.9-1.1%), 58.2% (51.7-64.6%) vs. 46.8% (40.2-53.4%), 66.2% (59.8-72.2%) vs. 49.8% (43.2-56.4%), and 17.9% (12.1-25.2%) vs. 28.2% (20.0-37.6%), respectively. TXI, age, withdrawal time, and endoscopy type were identified as significant factors affecting the MAP and the ADR using multivariate regression analysis. CONCLUSIONS: Our study indicates that TXI improve the detection of colorectal neoplastic lesions. However, prospective randomized trials are required to confirm these findings.


Assuntos
Adenoma , Neoplasias do Colo , Pólipos do Colo , Neoplasias Colorretais , Humanos , Estudos Prospectivos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Colonoscopia/métodos , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Cor
6.
BMC Gastroenterol ; 22(1): 10, 2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-34991489

RESUMO

BACKGROUND: Endoscopic submucosal dissection (ESD) is technically difficult and requires considerable training. The authors have developed a multi-loop traction device (MLTD), a new traction device that offers easy attachment and detachment. We aimed to evaluate the utility of MLTD in ESD. METHODS: This ex vivo pilot study was a prospective, block-randomized, comparative study of a porcine stomach model. Twenty-four lesions were assigned to a group that undertook ESD using the MLTD (M-ESD group) and a group that undertook conventional ESD (C-ESD group) to compare the speed of submucosal dissection. In addition, the data of consecutive 10 patients with eleven gastric lesions was collected using electronic medical records to clarify the inaugural clinical outcomes of gastric ESD using MLTD. RESULTS: The median (interquartile range) speed of submucosal dissection in the M-ESD and C-ESD groups were 141.5 (60.9-177.6) mm2/min and 35.5 (20.8-52.3) mm2/min, respectively; submucosal dissection was significantly faster in the M-ESD group (p < 0.05). The rate of en bloc resection and R0 resection was 100% in both groups, and there were no perforation in either group. The MLTD attachment time was 2.5 ± 0.9 min and the MLTD extraction time was 1.0 ± 1.1 min. Clinical outcomes of MLTD in gastric ESD were almost the same as those of ex vivo pilot study. CONCLUSIONS: MLTD increased the speed of submucosal dissection in ESD and was similarly effective when used by expert and trainee endoscopists without perforation. MLTD can potentially ensure a safer and faster ESD.


Assuntos
Ressecção Endoscópica de Mucosa , Animais , Humanos , Ressecção Endoscópica de Mucosa/efeitos adversos , Projetos Piloto , Estudos Prospectivos , Estômago , Suínos , Tração , Resultado do Tratamento
7.
Surg Endosc ; 35(12): 6882-6891, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33258034

RESUMO

BACKGROUND: Blood group O of ABO blood group system is considered as a risk factor for various bleeding events, but the relationship with endoscopic treatment-associated bleeding has yet to be investigated. This study aimed to evaluate whether blood group O is associated with delayed bleeding after colorectal endoscopic resection. METHODS: This was a retrospective observational study based on medical records at four university hospitals in Japan. We reviewed the records for consecutive patients who underwent colorectal endoscopic resection from January 2014 through December 2017. The primary outcome was the incidence of delayed bleeding, defined as hematochezia or melena, requiring endoscopy, transfusion, or any hemostatic intervention up to 28 days after endoscopic resection. Multivariate logistic regression analysis was performed to adjust the impact of blood group O on the delayed bleeding. RESULTS: Among 10,253 consecutive patients who underwent colorectal endoscopic resection during the study period, 8625 patients met the criteria. In total, delayed bleeding occurred in 255 patients (2.96%). The O group had significantly more bleeding events compared with the non-O group (A, B, and AB) (relative risk, 1.62 [95% confidence interval, 1.24-2.10]; P < 0.001). In multivariate logistic regression analysis, blood group O remained an independent risk factor for the bleeding (adjusted odds ratio, 1.60 [95% confidence interval, 1.18-2.17]; P = 0.002). CONCLUSIONS: Blood group O was associated with an increased risk of delayed bleeding in patients undergoing colorectal endoscopic resection. Preoperative screening for ABO blood group could improve risk assessments.


Assuntos
Antígenos de Grupos Sanguíneos , Neoplasias Colorretais , Hemorragia Gastrointestinal/epidemiologia , Hemorragia Gastrointestinal/etiologia , Humanos , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/etiologia , Estudos Retrospectivos , Fatores de Risco
8.
Dig Endosc ; 33(2): 218-230, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32935376

RESUMO

Artificial intelligence (AI) has been attracting considerable attention as an important scientific topic in the field of medicine. Deep-leaning (DL) technologies have been applied more dominantly than other traditional machine-learning methods. They have demonstrated excellent capability to retract visual features of objectives, even unnoticeable ones for humans, and analyze huge amounts of information within short periods. The amount of research applying DL-based models to real-time computer-aided diagnosis (CAD) systems has been increasing steadily in the GI endoscopy field. An array of published data has already demonstrated the advantages of DL-based CAD models in the detection and characterization of various neoplastic lesions, regardless of the level of the GI tract. Although the diagnostic performances and study designs vary widely, owing to a lack of academic standards to assess the capability of AI for GI endoscopic diagnosis fairly, the superiority of CAD models has been demonstrated for almost all applications studied so far. Most of the challenges associated with AI in the endoscopy field are general problems for AI models used in the real world outside of medical fields. Solutions have been explored seriously and some solutions have been tested in the endoscopy field. Given that AI has become the basic technology to make machines react to the environment, AI would be a major technological paradigm shift, for not only diagnosis but also treatment. In the near future, autonomous endoscopic diagnosis might no longer be just a dream, as we are witnessing with the advent of autonomously driven electric vehicles.


Assuntos
Inteligência Artificial , Endoscopia , Diagnóstico por Computador , Humanos , Aprendizado de Máquina
9.
Dig Endosc ; 33(4): 486-519, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33713493

RESUMO

The Colonoscopy Screening and Surveillance Guidelines were developed by the Japan Gastroenterological Endoscopy Society as basic guidelines based on the scientific methods. The importance of endoscopic screening and surveillance for both detection and post-treatment follow-up of colorectal cancer has been recognized as essential to reduce disease mortality. There is limited high-level evidence in this field; therefore, we had to focus on the consensus of experts. These clinical practice guidelines consist of 20 clinical questions and eight background knowledge topics that have been determined as the current guiding principles.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer , Humanos , Japão/epidemiologia , Programas de Rastreamento
10.
Dig Endosc ; 33(7): 1131-1138, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33476415

RESUMO

OBJECTIVES: To compare the efficacy and safety of oral sulfate solution administered using the same-day dose and the split-dose regimens with those of polyethylene glycol plus ascorbate solution, used for bowel preparation in Japanese patients undergoing colonoscopy. METHODS: This multicenter (n = 13), randomized, active-controlled, colonoscopist- and image evaluator-blinded, noninferiority study with parallel-group comparison recruited 632 patients from December 2018 to June 2019. Of these, 602 patients were divided into the oral sulfate solution same-day dose group (n = 200); oral sulfate solution split-dose group (n = 202); and polyethylene glycol plus ascorbate same-day dose group (n = 200). Differences in the efficacy rates between the polyethylene glycol plus ascorbate group and each oral sulfate solution group were calculated using the asymptotic method. The safety of the oral sulfate solution was evaluated, based on the occurrence of adverse events and reactions. RESULTS: Both oral sulfate solution protocols were confirmed as noninferior to the polyethylene glycol plus ascorbate protocol for bowel-cleansing. The occurrence of adverse reactions was significantly lower in the oral sulfate solution same-day dose group than in the polyethylene glycol plus ascorbate group (P = 0.010). The occurrence of adverse reactions was not significantly different between the oral sulfate solution split-dose and the polyethylene glycol plus ascorbate group. CONCLUSIONS: Oral sulfate solution is not only safe and efficacious but also not inferior to polyethylene glycol plus ascorbate solution (active control). It could be used for bowel preparation in Japanese patients scheduled for colonoscopy (Clinical trial registration number: NCT03794310).


Assuntos
Catárticos , Colonoscopia , Catárticos/efeitos adversos , Humanos , Japão , Polietilenoglicóis/efeitos adversos , Sulfatos
11.
J Am Chem Soc ; 142(38): 16420-16428, 2020 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-32799448

RESUMO

Curved π-electronic molecules, dipyrrolylbenzodiazepines (dpbs), were synthesized via condensation of 1,3-dipyrrolyldiketones and phenylenediamines. Dpbs exhibited 1D hydrogen-bonding chains between pyrrole NH and diazepine N and the resulting packing structures in the solid state. The pyrrole and diazepine N sites coordinate RhI, providing curved π-electronic systems of increasing rigidity. Dpb underwent coassembly with C60, which was surrounded by a hydrogen-bonding ring structure of six dpbs. On photoexcitation, the coassembly exhibited ultrafast electron transfer from the dpb moiety to C60, depending on their proximal arrangement as well as electron-donating and -accepting properties.

12.
J Am Chem Soc ; 142(1): 27-32, 2020 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-31868362

RESUMO

Recently, metal-organic frameworks (MOFs) composed of sulfur secondary building units (sulfur-SBUs) have attracted significant attention as unique electronic materials with high conductivities and photo- and electrocatalytic properties. Herein we report the crystal structure of KGF-1, an example of a Pb-MOF composed of three-dimensionally extended sulfur-SBUs that displays molecular sieving behavior, visible-light absorption, and a semiconductor band structure and is a hydrogen-evolution photocatalyst.

13.
Surg Endosc ; 34(4): 1625-1633, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31214802

RESUMO

BACKGROUND AND STUDY AIMS: An automatic carbon dioxide (CO2) insufflating system (SPACE) was developed to stabilize intra-lumenal pressure (ILP) during endoscopic interventions. This study investigated whether SPACE could improve the control and monitoring of extra-lumenal intra-abdominal pressure (IAP) after establishing a perforation during endoscopic full-thickness resection (EFTR) of the gastric wall in porcine models. MATERIALS AND METHODS: After first establishing the optimal preset pressure for gastric EFTR in four pigs, we compared IAP dynamics during EFTR between manual insufflation and SPACE using a block-randomized study (n = 10). IAP was percutaneously monitored and plotted on a timeline graph every 5 s. The maximal IAP and the area under the IAP curve exceeding 10 mmHg (AUC≥10 mmHg) were compared between groups, with the agreement between IAP and endolumenally monitored ILP also analyzed for animals in the SPACE group. RESULTS: In the first study, 8 mmHg was identified as the most preferable preset pressure after establishment of the perforation. In the randomized study, the mean maximal IAP in the SPACE group was significantly lower than that in the manual insufflation group (11.0 ± 2.0 mmHg vs. 17.0 ± 3.5 mmHg; P = 0.03). The mean AUC≥10 mmHg was also significantly smaller in the SPACE group. Bland-Altman analysis demonstrated agreement between IAP and ILP within a range of ± 1.0 mmHg. CONCLUSIONS: SPACE could be used to control and safely monitor IAP during gastric EFTR by measuring ILP during perforation of the gastric wall.


Assuntos
Endoscopia , Insuflação , Monitorização Intraoperatória , Animais , Feminino , Dióxido de Carbono , Endoscopia/métodos , Insuflação/métodos , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Pressão , Suínos
14.
J Am Chem Soc ; 141(6): 2446-2450, 2019 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-30563330

RESUMO

Infrared (IR) light represents an untapped energy source accounting for almost half of all solar energy. Thus, there is a need to develop systems to convert IR light to fuel and make full use of this plentiful resource. Herein, we report photocatalytic H2 evolution driven by near- to shortwave-IR light (up to 2500 nm) irradiation, based on novel CdS/Cu7S4 heterostructured nanocrystals. The apparent quantum yield reached 3.8% at 1100 nm, which exceeds the highest efficiencies achieved by IR light energy conversion systems reported to date. Spectroscopic results revealed that plasmon-induced hot-electron injection at p-n heterojunctions realizes exceptionally long-lived charge separation (>273 µs), which results in efficient IR light to hydrogen conversion. These results pave the way for the exploration of undeveloped low-energy light for solar fuel generation.

15.
Gastrointest Endosc ; 89(3): 460-469, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30452914

RESUMO

BACKGROUND AND AIMS: Colorectal flat (nonpolypoid) lesions can be overlooked during colonoscopy. This study evaluated the efficacy of updated autofluorescence imaging (AFI) for detecting colorectal flat neoplasms. METHODS: This was a prospective, multicenter, randomized controlled trial in 9 Japanese tertiary institutions. Patients undergoing colonoscopy because of positive fecal immunochemical tests, surveillance after polypectomy, or investigation of minor symptoms were enrolled and randomly assigned to either the white-light imaging (WLI) or the AFI group. Primary outcome measurement was number of flat neoplasms per patient. RESULTS: From November 2015 to June 2017, 817 patients were enrolled. After excluding 15 patients, 802 were finally analyzed (404, WLI; 398, AFI). Patients' backgrounds (sex, age, indication of colonoscopy, experience of endoscopists) and quality of colonoscopy (bowel preparation, sedative use, cecal insertion rate, insertion and withdrawal time) were not different between groups. Number of flat neoplasms in each patient was significantly higher in the AFI than in the WLI group (.87 [95% confidence interval [CI], .78-.97] vs .53 [95% CI, .46-.61]), whereas overall and polypoid neoplasm detection was not significantly different between the groups (1.33 [95% CI, 1.22-1.45] vs 1.14 [95% CI, 1.03-1.24], .46 [95% CI, .40-.53] vs .60 [95% CI, .53-.68]). Flat neoplasms were more frequently detected in the right-sided colon with AFI (.61 [95% CI, .54-.70] vs .30 [95% CI, .25-.36]) but not in the left-sided colon and rectum (.26 [95% CI, .21-.32] vs .23 [95% CI, .19-.28]). CONCLUSIONS: Updated AFI improves the detection of flat colorectal neoplasms in the right-sided colon compared with WLI. (Clinical trial registration number: UMIN000019355.).


Assuntos
Adenoma/patologia , Carcinoma/patologia , Pólipos do Colo/patologia , Colonoscopia/métodos , Neoplasias Colorretais/patologia , Imagem Óptica/métodos , Adenoma/diagnóstico , Assistência ao Convalescente , Idoso , Carcinoma/diagnóstico , Colo Ascendente/patologia , Colo Descendente/patologia , Pólipos do Colo/diagnóstico , Pólipos do Colo/cirurgia , Neoplasias Colorretais/diagnóstico , Feminino , Humanos , Imunoquímica , Pólipos Intestinais/diagnóstico , Pólipos Intestinais/patologia , Masculino , Pessoa de Meia-Idade , Sangue Oculto , Reto/patologia , Carga Tumoral
16.
Scand J Gastroenterol ; 54(6): 800-805, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31195905

RESUMO

Objectives: An endoscopic technique that provides ≥90% negative predictive value (NPV) for differentiating neoplastic polyps is needed for the management of diminutive (≤5 mm) rectosigmoid polyps. This study aimed to assess whether a newly developed software can achieve ≥90% NPV for differentiating rectosigmoid diminutive polyps based on the green-to-red (G/R) ratio, obtained by dividing the green color tone intensity by the red color tone intensity on autofluorescence imaging (AFI). Methods: From December 2017 to May 2018, consecutive patients with known polyps who were scheduled for endoscopic treatment at our institution were prospectively recruited. All colorectal diminutive polyps were differentiated by computer-aided diagnosis using autofluorescence imaging (CAD-AFI) using a novel software-based automatic color intensity analysis; subsequent diagnosis was made by endoscopists based on trimodal imaging endoscopy (TME), which combines AFI, white-light imaging (WLI) and magnifying narrow-band imaging (M-NBI) findings. Thereafter, all polyps were removed endoscopically, and the histopathological diagnosis was evaluated. Results: Ninety-five patients with 258 diminutive rectosigmoid polyps and 171 diminutive non-rectosigmoid polyps were enrolled. Regarding diminutive rectosigmoid polyps, the NPV for differentiating neoplastic polyps was 93.4% (184/197) [95% confidence interval (CI), 89.0%-96.4%] with CAD-AFI and 94.9% (185/195) (95% CI, 90.8%-97.5%) with TME. The accuracy, sensitivity, specificity, and positive predictive value for differentiating diminutive rectosigmoid neoplastic polyps by CAD-AFI were 91.5%, 80.0%, 95.3% and 85.2%, respectively. Conclusions: Real-time CAD-AFI was effective for differentiating diminutive rectosigmoid polyps. This objective technology, which does not require extensive training or endoscopic expertise, can contribute to the effective management of diminutive rectosigmoid polyps.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Diagnóstico por Computador , Imagem de Banda Estreita/métodos , Idoso , Pólipos do Colo/patologia , Pólipos do Colo/cirurgia , Cor , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Diagnóstico Diferencial , Detecção Precoce de Câncer , Feminino , Fluorescência , Humanos , Aumento da Imagem/métodos , Japão , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Software
17.
Phys Chem Chem Phys ; 21(40): 22563-22568, 2019 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-31588937

RESUMO

We fabricated a chlorophyll (Chl)-based biosolar cell with H2Chl-sensitized TiO2 as an acceptor and (ZnChl)n as a donor. This solar cell gives a relatively high quantum yield from the absorption spectral contribution from both the donor and acceptor species. We employed subpicosecond time-resolved absorption spectroscopy (TAS) to study the excited state dynamics at the Chl interface. A charge transfer (CT) state between TiO2-H2Chl and (ZnChl)n was observed at 640 nm after excitation at the Qy peaks, 680 nm and 720 nm. This CT state is entirely different from the CT states observed for either TiO2-H2Chl (TiO2-H2Chl/spiro-OMeTAD) or TiO2-(ZnChl)n systems. Due to the slower charge transfer process from H2Chl+ to TiO2 as compared to that from (ZnChl)n+ to H2Chl, the CT lifetimes of H2Chl--(ZnChl)n+ (τ1 = 0.1 ps, τ2 = 1.4 ps) excited at 720 nm are slightly shorter than that excited at 680 nm (τ1 = 0.2 ps, τ2 = 5.6 ps). The TAS results suggest that the interface of TiO2-H2Chl and (ZnChl)n not only transfers holes as spiro-OMeTAD does, but also provides a built-in field for charge dissociation between the two Chl species.

18.
Surg Endosc ; 33(8): 2548-2552, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30334164

RESUMO

BACKGROUND: Objective assessment of endoscopist competency is important. Recently, the endoscopic part-task training box (Thompson Endoscopic Skills Trainer [TEST]) was developed to assess endoscopist competency. We aimed to evaluate the ability of the TEST to assess competency during endoscopic procedures, especially endoscopic submucosal dissection (ESD). METHODS: Twenty-three physicians were included in this study. Correlations between TEST scores and the following factors were evaluated: years of endoscopic experience, number of esophagogastroduodenoscopies (EGDs) performed, number of colonoscopies (CSs) performed, cecal intubation rate, number of gastric ESDs performed, gastric ESD procedure time/lesion size (min/mm2), and gastric ESD self-completion rate. Also, correlation coefficients between the number of gastric ESDs performed and each of gastric ESD procedure time/lesion size and gastric ESD self-completion rate were calculated. RESULTS: TEST scores showed strong correlations to different factors: years of experience in endoscopy: 0.957 (p < 0.01); number of EGDs: 0.947 (p < 0.01); number of CSs: 0.947, (p < 0.01); number of gastric ESDs: 0.924 (p < 0.01); gastric ESD procedure time/lesion size: - 0.9 (p < 0.01); self-completion rate of gastric ESDs: 0.857 (p < 0.005). The number of gastric ESDs performed was not more strongly correlated to procedure time of gastric ESDs or self-completion rate of gastric ESDs compared to TEST scores (- 0.824 (p < 0.01) and 0.704 (p < 0.05), respectively). TEST scores of endoscopists with a cecal intubation rate ≥ 90% were > 380, while the scores of physicians with a gastric ESD self-completion rate ≥ 90% were > 700. CONCLUSIONS: TEST score correlates with both basic and advanced endoscopic procedures. TEST is therefore a promising option for assessing endoscopist competency, and might be useful for providing threshold scores as competency markers for specific endoscopic procedures such as gastric ESD.


Assuntos
Competência Clínica , Avaliação Educacional/métodos , Ressecção Endoscópica de Mucosa/educação , Ressecção Endoscópica de Mucosa/métodos , Mucosa Gástrica/cirurgia , Humanos , Ensino
19.
Surg Endosc ; 33(12): 4016-4025, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30725255

RESUMO

OBJECTIVE: Endoscopic submucosal dissection (ESD) allows for en bloc resection of superficial gastrointestinal neoplasms; however, US experience has been limited. We aimed to evaluate our clinical outcomes in colorectal ESD. DESIGN: This prospective study included consecutive patients undergoing colorectal ESD at a major US center. Demographics, lesion and technical characteristics, outcomes, adverse events, and pathological diagnoses were recorded. Factors affecting resection outcomes and procedure time were evaluated. RESULTS: 77 patients who underwent colorectal ESD were analyzed. Mean colorectal lesion diameter was 49.4 mm. Mean procedure time was 104.7 min, and 97.4% of patients were discharged home on the same day. En bloc, complete, and curative resection was achieved in 97.4%, 97.4%, and 93.5% of colorectal ESD cases. Microperforation and delayed bleeding rates were 1.3% and 3.9%. On univariable analysis, the presence of tattoo adversely affected en bloc resection (p = 0.002), complete resection (p = 0.002), and curative resection (p = 0.008). Prior EMR attempts adversely affected en bloc resection (p = 0.028), complete resection (p = 0.028), and procedure time (p = 0.008). On multivariable analysis, the presence of tattoo predicted failure to achieve curative resection (OR 0.13; 95% CI 0.02-0.98; p = 0.048). Lesion size > 50 mm (OR 3.89; 95% CI 1.13-13.41; p = 0.031), presence of tattoo (OR 9.38; 95% CI 1.05-83.83; p = 0.045), and prior EMR attempts (OR 7.13; 95% CI 1.76-28.90; p = 0.006) predicted procedure time ≥ 90 min. A scoring system was created to predict prolonged ESD procedure time and was externally validated, with AUC 0.78 (95% CI 0.73-0.83). CONCLUSION: This study demonstrates the effects of multiple risk factors on resection outcomes and procedure time in colorectal ESD. Tattoo placement and attempted EMR should be avoided for lesions being considered for ESD.


Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Carga Tumoral , Estados Unidos/epidemiologia
20.
Gastrointest Endosc ; 88(5): 854-864, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29908178

RESUMO

BACKGROUND AND AIMS: Although colonoscopy is the criterion standard for detection of colorectal adenomas, some adenomas are missed. Full-spectrum endoscopy (FUSE) allows for observation with a 330-degree angle of view, which is expected to decrease the miss rate. However, no consensus has been reached regarding the superiority of FUSE over standard forward-viewing colonoscopy (SFVC) for detection of adenomas; we therefore compared new-generation FUSE and SFVC regarding colorectal adenoma miss rate (AMR) in this, the first reported randomized control trial using new-generation FUSE. METHODS: We enrolled individuals aged 40 to 75 years who had been referred for screening, surveillance, fecal occult blood test positivity, or symptoms in a prospective randomized trial of tandem colonoscopy in 8 institutions. Patients were randomly assigned (1:1) via computer-generated stratified randomization. Neither the endoscopists nor patients were blinded to the allocation. The primary endpoint was AMR per patient (AMR-PP). RESULTS: We enrolled 345 patients and included 319 in the per-protocol analyses. AMR-PP was significantly lower with FUSE (11.7%; 95% confidence interval [CI], 8.0%-15.4%) than with SFVC (22.9%; 95% CI, 17.5%-28.3%; P < .001). AMR-PP for lesions ≤5 mm in size was significantly lower with FUSE (10.4%; 95% CI, 6.5%-14.3%) than with SFVC (20.0%; 95% CI, 14.4%-25.6%; P = .0057). Furthermore, AMR-PP in the ascending colon was significantly lower with FUSE (4.3%; 95% CI, 1.4%-7.2%) than with SFVC (10.6%; 95% CI, 6.1%-15.1%; P = .0212). CONCLUSIONS: FUSE is superior to SFVC regarding both AMR-PP and AMR; additionally, AMR-PP is both significantly lower with FUSE than SFVC for lesions ≤5 mm in size and in the ascending colon. (Clinical trial registration number: UMIN000020448.).


Assuntos
Adenoma/diagnóstico , Colonoscópios , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Adenoma/patologia , Idoso , Neoplasias Colorretais/patologia , Intervalos de Confiança , Desenho de Equipamento , Reações Falso-Negativas , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA