Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 34(1): 39-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37552259

RESUMO

OBJECTIVES: Quantitative CT imaging is an important emphysema biomarker, especially in smoking cohorts, but does not always correlate to radiologists' visual CT assessments. The objectives were to develop and validate a neural network-based slice-wise whole-lung emphysema score (SWES) for chest CT, to validate SWES on unseen CT data, and to compare SWES with a conventional quantitative CT method. MATERIALS AND METHODS: Separate cohorts were used for algorithm development and validation. For validation, thin-slice CT stacks from 474 participants in the prospective cross-sectional Swedish CArdioPulmonary bioImage Study (SCAPIS) were included, 395 randomly selected and 79 from an emphysema cohort. Spirometry (FEV1/FVC) and radiologists' visual emphysema scores (sum-visual) obtained at inclusion in SCAPIS were used as reference tests. SWES was compared with a commercially available quantitative emphysema scoring method (LAV950) using Pearson's correlation coefficients and receiver operating characteristics (ROC) analysis. RESULTS: SWES correlated more strongly with the visual scores than LAV950 (r = 0.78 vs. r = 0.41, p < 0.001). The area under the ROC curve for the prediction of airway obstruction was larger for SWES than for LAV950 (0.76 vs. 0.61, p = 0.007). SWES correlated more strongly with FEV1/FVC than either LAV950 or sum-visual in the full cohort (r = - 0.69 vs. r = - 0.49/r = - 0.64, p < 0.001/p = 0.007), in the emphysema cohort (r = - 0.77 vs. r = - 0.69/r = - 0.65, p = 0.03/p = 0.002), and in the random sample (r = - 0.39 vs. r = - 0.26/r = - 0.25, p = 0.001/p = 0.007). CONCLUSION: The slice-wise whole-lung emphysema score (SWES) correlates better than LAV950 with radiologists' visual emphysema scores and correlates better with airway obstruction than do LAV950 and radiologists' visual scores. CLINICAL RELEVANCE STATEMENT: The slice-wise whole-lung emphysema score provides quantitative emphysema information for CT imaging that avoids the disadvantages of threshold-based scores and is correlated more strongly with reference tests than LAV950 and reader visual scores. KEY POINTS: • A slice-wise whole-lung emphysema score (SWES) was developed to quantify emphysema in chest CT images. • SWES identified visual emphysema and spirometric airflow limitation significantly better than threshold-based score (LAV950). • SWES improved emphysema quantification in CT images, which is especially useful in large-scale research.


Assuntos
Obstrução das Vias Respiratórias , Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Estudos Prospectivos , Estudos Transversais , Enfisema Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Enfisema/diagnóstico por imagem , Obstrução das Vias Respiratórias/diagnóstico por imagem
2.
Acta Radiol ; 65(3): 307-317, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38115809

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is useful in the diagnosis of clinically significant prostate cancer (csPCa). MRI-derived radiomics may support the diagnosis of csPCa. PURPOSE: To investigate whether adding radiomics from biparametric MRI to predictive models based on clinical and MRI parameters improves the prediction of csPCa in a multisite-multivendor setting. MATERIAL AND METHODS: Clinical information (PSA, PSA density, prostate volume, and age), MRI reviews (PI-RADS 2.1), and radiomics (histogram and texture features) were retrieved from prospectively included patients examined at different radiology departments and with different MRI systems, followed by MRI-ultrasound fusion guided biopsies of lesions PI-RADS 3-5. Predictive logistic regression models of csPCa (Gleason score ≥7) for the peripheral (PZ) and transition zone (TZ), including clinical data and PI-RADS only, and combined with radiomics, were built and compared using receiver operating characteristic (ROC) curves. RESULTS: In total, 456 lesions in 350 patients were analyzed. In PZ and TZ, PI-RADS 4-5 and PSA density, and age in PZ, were independent predictors of csPCa in models without radiomics. In models including radiomics, PI-RADS 4-5, PSA density, age, and ADC energy were independent predictors in PZ, and PI-RADS 5, PSA density and ADC mean in TZ. Comparison of areas under the ROC curve (AUC) for the models without radiomics (PZ: AUC = 0.82, TZ: AUC = 0.80) versus with radiomics (PZ: AUC = 0.82, TZ: AUC = 0.82) showed no significant differences (PZ: P = 0.366; TZ: P = 0.171). CONCLUSION: PSA density and PI-RADS are potent predictors of csPCa. Radiomics do not add significant information to our multisite-multivendor dataset.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Antígeno Prostático Específico , Radiômica , Curva ROC , Estudos Retrospectivos
3.
BMC Psychiatry ; 23(1): 771, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872497

RESUMO

BACKGROUND: The role of inflammation in the aetiology of schizophrenia has gained wide attention and research on the association shows an exponential growth in the last 15 years. Autoimmune diseases and severe infections are risk factors for the later development of schizophrenia, elevated inflammatory markers in childhood or adolescence are associated with a greater risk of schizophrenia in adulthood, individuals with schizophrenia have increased levels of pro-inflammatory cytokines compared to healthy controls, and autoimmune diseases are overrepresented in schizophrenia. However, treatments with anti-inflammatory agents are so far of doubtful clinical relevance. The primary objective of this study is to test whether the monoclonal antibody rituximab, directed against the B-cell antigen CD20 ameliorates psychotic symptoms in adults with schizophrenia or schizoaffective disorder and to examine potential mechanisms. A secondary objective is to examine characteristics of inflammation-associated psychosis and to identify pre-treatment biochemical characteristics of rituximab responders. A third objective is to interview a subset of patients and informants on their experiences of the trial to obtain insights that rating scales may not capture. METHODS: A proof-of-concept study employing a randomised, parallel-group, double-blind, placebo-controlled design testing the effect of B-cell depletion in patients with psychosis. 120 participants with a diagnosis of schizophrenia spectrum disorders (SSD) (ICD-10 codes F20, F25) will receive either one intravenous infusion of rituximab (1000 mg) or saline. Psychiatric measures and blood samples will be collected at baseline, week 12, and week 24 post-infusion. Brief assessments will also be made in weeks 2 and 7. Neuroimaging and lumbar puncture, both optional, will be performed at baseline and endpoints. Approximately 40 of the patients and their informants will be interviewed for qualitative analyses on the perceived changes in well-being and emotional qualities, in addition to their views on the research. DISCUSSION: This is the first RCT investigating add-on treatment with rituximab in unselected SSD patients. If the treatment is helpful, it may transform the treatment of patients with psychotic disorders. It may also heighten the awareness of immune-psychiatric disorders and reduce stigma. TRIAL REGISTRATION: NCT05622201, EudraCT-nr 2022-000220-37 version 2.1. registered 14th of October 2022.


Assuntos
Doenças Autoimunes , Transtornos Psicóticos , Adulto , Humanos , Método Duplo-Cego , Inflamação , Transtornos Psicóticos/tratamento farmacológico , Ensaios Clínicos Controlados Aleatórios como Assunto , Rituximab/uso terapêutico , Resultado do Tratamento
4.
Eur Radiol ; 31(8): 5980-5989, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33635394

RESUMO

OBJECTIVES: To prospectively validate three quantitative single-energy CT (SE-CT) methods for classifying uric acid (UA) and non-uric acid (non-UA) stones. METHODS: Between September 2018 and September 2019, 116 study participants were prospectively included in the study if they had at least one 3-20-mm urinary stone on an initial urinary tract SE-CT scan. An additional dual-energy CT (DE-CT) scan was performed, limited to the stone of interest. Additionally, to include a sufficient number of UA stones, eight participants with confirmed UA stone on DE-CT were retrospectively included. The SE-CT stone features used in the prediction models were (1) maximum attenuation (maxHU) and (2) the peak point Laplacian (ppLapl) calculated at the position in the stone with maxHU. Two prediction models were previously published methods (ppLapl-maxHU and maxHU) and the third was derived from the previous results based on the k-nearest neighbors (kNN) algorithm (kNN-ppLapl-maxHU). The three methods were evaluated on this new independent stone dataset. The reference standard was the CT vendor's DE-CT application for kidney stones. RESULTS: Altogether 124 participants (59 ± 14 years, 91 men) with 106 non-UA and 37 UA stones were evaluated. For classification of UA and non-UA stones, the sensitivity, specificity, and accuracy were 100% (37/37), 97% (103/106), and 98% (140/143), respectively, for kNN-ppLapl-maxHU; 95% (35/37), 98% (104/106), and 97% (139/143) for ppLapl-maxHU; and 92% (34/37), 94% (100/106), and 94% (134/143) for maxHU. CONCLUSION: A quantitative SE-CT method (kNN-ppLapl-maxHU) can classify UA stones with accuracy comparable to DE-CT. KEY POINTS: • Single-energy CT is the first-line diagnostic tool for suspected renal colic. • A single-energy CT method based on the internal urinary stone attenuation distribution can classify urinary stones into uric acid and non-uric acid stones with high accuracy. • This immensely increases the availability of in vivo stone analysis.


Assuntos
Ácido Úrico , Cálculos Urinários , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Cálculos Urinários/diagnóstico por imagem
5.
J Digit Imaging ; 33(5): 1185-1193, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32779016

RESUMO

Emphysema is visible on computed tomography (CT) as low-density lesions representing the destruction of the pulmonary alveoli. To train a machine learning model on the emphysema extent in CT images, labeled image data is needed. The provision of these labels requires trained readers, who are a limited resource. The purpose of the study was to test the reading time, inter-observer reliability and validity of the multi-reader-multi-split method for acquiring CT image labels from radiologists. The approximately 500 slices of each stack of lung CT images were split into 1-cm chunks, with 17 thin axial slices per chunk. The chunks were randomly distributed to 26 readers, radiologists and radiology residents. Each chunk was given a quick score concerning emphysema type and severity in the left and right lung separately. A cohort of 102 subjects, with varying degrees of visible emphysema in the lung CT images, was selected from the SCAPIS pilot, performed in 2012 in Gothenburg, Sweden. In total, the readers created 9050 labels for 2881 chunks. Image labels were compared with regional annotations already provided at the SCAPIS pilot inclusion. The median reading time per chunk was 15 s. The inter-observer Krippendorff's alpha was 0.40 and 0.53 for emphysema type and score, respectively, and higher in the apical part than in the basal part of the lungs. The multi-split emphysema scores were generally consistent with regional annotations. In conclusion, the multi-reader-multi-split method provided reasonably valid image labels, with an estimation of the inter-observer reliability.


Assuntos
Enfisema Pulmonar , Feminino , Humanos , Pulmão , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Enfisema Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
6.
Eur Radiol ; 28(4): 1692-1700, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29134354

RESUMO

OBJECTIVES: To compare the assessment of patients with multiple sclerosis (MS) using synthetic and conventional MRI. MATERIALS AND METHODS: Synthetic and conventional axial images were prospectively acquired for 52 patients with diagnosed MS. Quantitative MRI (qMRI) was used for measuring proton density and relaxation times (T1, T2) and then, based on these parameters, synthetic T1W, T2W and FLAIR images were calculated. Image stacks were reviewed blindly, independently and in random order by two radiologists. The number and location for all lesions were documented and categorised. A combined report of lesion load and presence of contrast-enhancing lesions was compiled for each patient. Agreement was evaluated using kappa statistic. RESULTS: There was no significant difference in lesion detection using synthetic and conventional MRI in any anatomical region or for any of the three image types. Inter- and intra-observer agreements were mainly higher (p < 0.05) using conventional images but there was no significant difference in any specific region or for any image type. There was no significant difference in the outcome of the combined reports. CONCLUSION: Synthetic MR images show potential to be used in the assessment of MS dissemination in space (DIS) despite a slightly lower inter- and intra-observer agreement compared to conventional MRI. KEY POINTS: • Synthetic MR images may potentially be useful in the assessment of MS. • Examination times may be shortened. • Inter- and intra-observer agreement is generally higher using conventional MRI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Variações Dependentes do Observador , Prótons , Fatores de Tempo , Adulto Jovem
7.
J Heart Valve Dis ; 26(5): 502-508, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-29762918

RESUMO

BACKGROUND: Flow measurements using cardiac magnetic resonance imaging (CMRI) enable quantification of the stroke volume, regurgitant volume (RV) and regurgitant fraction (RF) in patients with aortic regurgitation (AR). These variables are used to assess the severity of the valve disease and for the timing of surgery. The aim of the study was to investigate the impact of an increased heart rate on measurement of the RV and RF in patients with AR. METHODS: Among 13 patients with known moderate or severe AR, regurgitant flow measurements, using phase-contrast cine magnetic resonance imaging, were obtained in the ascending aorta. Flow measurements were obtained at rest and at increased heart rates after intravenous administration of atropine. RESULTS: The mean heart rate was 61 beats per min at rest and 91 beats per min after atropine administration. The RV and RF were 52 ml and 35% at rest, respectively, and 34 ml (p <0.001) and 30% (p = 0.065) at increased heart rate, respectively. CONCLUSIONS: An increased heart rate leads to a decreased RV. The RF is more stable and may therefore be preferable for severity grading in AR.


Assuntos
Insuficiência da Valva Aórtica , Atropina/farmacologia , Velocidade do Fluxo Sanguíneo/fisiologia , Frequência Cardíaca/efeitos dos fármacos , Idoso , Antiarrítmicos/farmacologia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Volume Sistólico , Tempo para o Tratamento
8.
Cardiovasc Ultrasound ; 15(1): 4, 2017 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-28270161

RESUMO

BACKGROUND: There is today no established approach to estimate right ventricular ejection fraction (RVEF) using 2D transthoracic echocardiography (TTE). The aim of this study was to evaluate a new method for RVEF calculations using 2D TTE and compare the results with cardiac magnetic resonance (CMR) imaging and tricuspid annular plane systolic excursion (TAPSE). METHODS: A total of 37 subjects, 25 retrospectively included patients and twelve healthy volunteers, were included to give a wide range of RVEF. The right ventricle (RV) was modeled as a part of an ellipsoid enabling calculation of the RV volume by combining three distance measurements. RVEF calculated according to the model, RVEFTTE, were compared with reference CMR-derived RVEF, RVEFCMR. Further, TAPSE was measured in the TTE images and the correlations were calculated between RVEFTTE, TAPSE and RVEFCMR. RESULTS: The mean values were RVEFCMR = 43 ± 12% (range 20-66%) and RVEFTTE = 50 ± 9% (range 34-65%). There was a high correlation (r = 0.80, p < 0.001) between RVEFTTE and RVEFCMR. Bland-Altman analysis showed a mean difference between RVEFCMR and RVEFTTE of 6 percentage points (ppt) with limits of agreement from -11 to 23 ppt. The mean value for TAPSE was 19 ± 5 mm and the correlation between TAPSE and RVEFCMR was moderate (r = 0.54, p < 0.001). The correlation between RVEFTTE and RVEFCMR was significantly higher (p < 0.05) than the correlation between TAPSE and RVEFCMR. CONCLUSIONS: The ellipsoid model shows promise for RVEF calculations using 2D TTE for a wide range of RVEF, providing RVEF estimates that were significantly better correlated to RVEF obtained from CMR compared to TAPSE.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Modelos Teóricos , Volume Sistólico/fisiologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia , Adulto , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Disfunção Ventricular Direita/diagnóstico
9.
Echocardiography ; 33(6): 844-53, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26841195

RESUMO

BACKGROUND: The position of the right ventricle (RV), often partly behind the sternum, implies difficulties to image the RV free wall using transthoracic echocardiography (TTE) and consequently limits the possibilities of stroke volume calculations. The aim of this study was to evaluate whether the volume of the right ventricle (RV) can be determined by combining TTE distance measurements that do not need the RV free wall to be fully visualized. METHODS: The RV volume was approximated by an ellipsoid composed of three distances. Distance measurements, modeled RV stroke volumes (RVSV), and RV ejection fraction (RVEF) were compared to reference values obtained from cardiac magnetic resonance (CMR) imaging for 12 healthy volunteers. RESULTS: Inter-modality comparisons showed that distance measurements were significantly underestimated in TTE compared to CMR. The modeled RV volumes using TTE distance measurements were underestimated compared to reference CMR volumes. There was, however, for TTE an agreement between modeled RVSV and left ventricular stroke volumes determined by biplane Simpson's rule. Similar agreement was shown between modeled RVSV based on CMR distance measurements and the CMR reference. Regarding RVEF, further studies including patients with a wider range of RVEF are needed to evaluate the method. CONCLUSION: In conclusion, the ellipsoid model of the RV provides good estimates of RVSVs, but volumes based on distance measurements from different modalities cannot be used interchangeably.


Assuntos
Pontos de Referência Anatômicos/anatomia & histologia , Pontos de Referência Anatômicos/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Sensibilidade e Especificidade , Volume Sistólico , Adulto Jovem
10.
Acta Radiol ; 56(4): 487-92, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24646626

RESUMO

BACKGROUND: The standard imaging procedure for a patient presenting with renal colic is unenhanced computed tomography (CT). The CT measured size has a close correlation to the estimated prognosis for spontaneous passage of a ureteral calculus. Size estimations of urinary calculi in CT images are still based on two-dimensional (2D) reformats. PURPOSE: To develop and validate a calculus oriented three-dimensional (3D) method for measuring the length and width of urinary calculi and to compare the calculus oriented measurements of the length and width with corresponding 2D measurements obtained in axial and coronal reformats. MATERIAL AND METHODS: Fifty unenhanced CT examinations demonstrating urinary calculi were included. A 3D symmetric segmentation algorithm was validated against reader size estimations. The calculus oriented size from the segmentation was then compared to the estimated size in axial and coronal 2D reformats. RESULTS: The validation showed 0.1 ± 0.7 mm agreement against reference measure. There was a 0.4 mm median bias for 3D estimated calculus length compared to 2D (P < 0.001), but no significant bias for 3D width compared to 2D. CONCLUSION: The length of a calculus in axial and coronal reformats becomes underestimated compared to 3D if its orientation is not aligned to the image planes. Future studies aiming to correlate calculus size with patient outcome should use a calculus oriented size estimation.


Assuntos
Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
J Adv Nurs ; 70(8): 1880-90, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24456491

RESUMO

AIMS: To describe patients' experiences of magnetic resonance examination of the liver and their experiences of two breath-hold techniques. BACKGROUND: Traditionally, patients are instructed by the radiographer to hold their breath during the examination. Alternatively, the patient can initiate the breath hold and start the image acquisition. Studies have revealed that magnetic resonance examinations can be experienced as challenging. DESIGN: Descriptive qualitative. METHODS: Semi-structured interviews were conducted with 28 patients and analysed using qualitative content analysis. The data collection was carried out from autumn 2010 to spring 2011. RESULTS: The patients' main experience was that they felt loss of control. This was described in terms of feeling trapped, being lost in time and lost as a result of uncertainty. They had many questions in their mind that they did not ask. Although their statements often revealed no clear preference regarding the techniques, almost half of the patients seemed to prefer self-initiated breath hold, as it was easier and less stressful. Those who preferred the radiographer-directed technique felt more confident leaving the responsibility to the radiographer. In general, the patients understood the importance of achieving the best quality images possible. CONCLUSION: Magnetic resonance examination can be experienced as being in loss of control. Nevertheless, not all patients wished to actively participate in magnetic resonance examination. Some preferred to hand over the responsibility to the radiographer. These results can form a base for radiographers' reflections of how to individualize and optimize the nursing care of patients undergoing magnetic resonance examinations.


Assuntos
Imageamento por Ressonância Magnética/psicologia , Respiração , Humanos , Suécia
12.
J Psychiatr Res ; 163: 378-385, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37269772

RESUMO

BACKGROUND: Roughly 20-30% of patients with Attention-deficit/hyperactivity disorder (ADHD) fail to respond to central stimulant (CS) medication. Genetic, neuroimaging, biochemical and behavioral biomarkers for CS response have been investigated, but currently there are no biomarkers available for clinical use that help identify CS responders and non-responders. METHODS: In the present paper, we studied if incentive salience and hedonic experience evaluated after a single-dose CS medication could predict response and non-response to CS medication. We used a bipolar visual analogue 'wanting' and 'liking' scale to gauge incentive salience and hedonic experience in 25 healthy controls (HC) and 29 ADHD patients. HC received 30 mg methylphenidate (MPH) and ADHD patients received either MPH or lisdexamphetamine (LDX) as selected by their clinician, with dosage individually determined for optimal effect. Clinician-evaluated global impression - severity (CGI-S) and improvement (CGI-I) and patient-evaluated improvement (PGI-I) were used to assess response to CS medication. Resting state functional magnetic resonance imaging (fMRI) was conducted before and after single-dose CS to correlate wanting and liking scores to changes in functional connectivity. RESULTS: Roughly 20% of the ADHD patients were CS non-responders (5 of 29). CS responders had significantly higher incentive salience and hedonic experience scores compared to healthy controls and CS non-responders. Resting state fMRI showed that wanting scores were significantly associated to changes in functional connectivity in ventral striatum including nucleus accumbens. CONCLUSION: Incentive salience and hedonic experience evaluated after a single-dose CS medication segregate CS responders and non-responders, with corresponding neuroimaging biomarkers in the brain reward system.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Estimulantes do Sistema Nervoso Central , Metilfenidato , Humanos , Estimulantes do Sistema Nervoso Central/uso terapêutico , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico por imagem , Transtorno do Deficit de Atenção com Hiperatividade/tratamento farmacológico , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Motivação , Metilfenidato/farmacologia , Metilfenidato/uso terapêutico
13.
Eur Radiol ; 22(4): 731-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22160167

RESUMO

OBJECTIVES: The size estimation in CT images of an obstructing ureteral calculus is important for the clinical management of a patient presenting with renal colic. The objective of the present study was to develop a reader independent urinary calculus segmentation algorithm using well-known digital image processing steps and to validate the method against size estimations by several readers. METHODS: Fifty clinical CT examinations demonstrating urinary calculi were included. Each calculus was measured independently by 11 readers. The mean value of their size estimations was used as validation data for each calculus. The segmentation algorithm consisted of interpolated zoom, binary thresholding and morphological operations. Ten examinations were used for algorithm optimisation and 40 for validation. Based on the optimisation results three segmentation method candidates were identified. RESULTS: Between the primary segmentation algorithm using cubic spline interpolation and the mean estimation by 11 readers, the bias was 0.0 mm, the standard deviation of the difference 0.26 mm and the Bland-Altman limits of agreement 0.0 ± 0.5 mm. CONCLUSIONS: The validation showed good agreement between the suggested algorithm and the mean estimation by a large number of readers. The limit of agreement was narrower than the inter-reader limit of agreement previously reported for the same data. KEY POINTS: The size of kidney stones is usually estimated manually by the radiologist. An algorithm for computer-aided size estimation is introduced. The variability between readers can be reduced. A reduced variability can give better information for treatment decisions.


Assuntos
Algoritmos , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Cálculos Urinários/diagnóstico por imagem , Urografia/métodos , Humanos , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Acta Radiol ; 53(9): 995-1003, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22983258

RESUMO

BACKGROUND: Magnetic resonance (MR) imaging and echocardiography both allow assessment of aortic valve stenosis. In MR the aortic valve area (AvA) is measured using planimetry while in transthoracic echocardiography (TTE) AvA is usually calculated by applying the continuity equation. PURPOSE: To compare the measured stenotic aortic valve areas using five different MR-acquisition alternatives with the corresponding area values calculated by TTE. MATERIAL AND METHODS: The aortic valve was imaged in 14 patients, with diagnosed aortic valve stenosis, using balanced steady state free precession (bSSFP) gradient echo (GE) and phase contrast imaging (PC). Three adjacent slices were planned to encompass the aortic valve and the aortic valve area was measured using planimetry. The two sets of complex valued images generated by the PC sequence formed three kinds of images that could be used for aortic valve area measurements: the magnitude image (PC/Mag), the modulus (PCA/M), and phase difference (PCA/P) between the two complex images, respectively. The valve area from TTE was calculated using the continuity equation. A cut-off of <1.0 cm(2) was used as a criteria for severe stenosis. RESULTS: The mean area differences between the different MR acquisitions and TTE method were -0.05 ± 0.37 cm(2) (GE), -0.18 ± 0.46 cm(2) (bSSFP), 0.27 ± 0.43 cm(2) (PC/Mag), 0.15 ± 0.32 cm(2) (PCA/P), and 0.26 ± 0.27 cm(2) (PCA/M). The valve area was significantly overestimated using PCA/M that, in turn, implied a significant underestimation of the aortic valve stenosis severity compared to the assessments using TTE. CONCLUSION: The smallest area valve difference between TTE and an MR-acquisition alternative is obtained with gradient echo images. The use of PCA/M leads to significant differences in planimetry measurements of the aortic valve orifice and the gradation of the stenosis severity compared to TTE.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
15.
Cells ; 11(18)2022 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-36139496

RESUMO

Probiotics can alter brain function via the gut-brain axis. We investigated the effect of a probiotic mixture containing Bifidobacterium longum, Lactobacillus helveticus and Lactiplantibacillus plantarum. In a randomized, placebo-controlled, double-blinded crossover design, 22 healthy subjects (6 m/16 f; 24.2 ± 3.4 years) underwent four-week intervention periods with probiotics and placebo, separated by a four-week washout period. Voxel-based morphometry indicated that the probiotic intervention affected the gray matter volume of a cluster covering the left supramarginal gyrus and superior parietal lobule (p < 0.0001), two regions that were also among those with an altered resting state functional connectivity. Probiotic intervention resulted in significant (FDR < 0.05) functional connectivity changes between regions within the default mode, salience, frontoparietal as well as the language network and several regions located outside these networks. Psychological symptoms trended towards improvement after probiotic intervention, i.e., the total score of the Hospital Anxiety and Depression Scale (p = 0.056) and its depression sub-score (p = 0.093), as well as sleep patterns (p = 0.058). The probiotic intervention evoked distinct changes in brain morphology and resting state brain function alongside slight improvements of psycho(bio)logical markers of the gut-brain axis. The combination of those parameters may provide new insights into the modes of action by which gut microbiota can affect gut-brain communication and hence brain function.


Assuntos
Bifidobacterium longum , Lactobacillus helveticus , Probióticos , Encéfalo , Voluntários Saudáveis , Humanos , Probióticos/uso terapêutico
16.
Front Nutr ; 9: 827182, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35571902

RESUMO

Background: Evidence from preclinical studies suggests that probiotics affect brain function via the microbiome-gut-brain axis, but evidence in humans remains limited. Objective: The present proof-of-concept study investigated if a probiotic product containing a mixture of Bifidobacterium longum R0175, Lactobacillus helveticus R0052 and Lactiplantibacillus plantarum R1012 (in total 3 × 109 CFU/day) affected functional brain responses in healthy subjects during an emotional attention task. Design: In this double-blinded, randomized, placebo-controlled crossover study (Clinicaltrials.gov, NCT03615651), 22 healthy subjects (24.2 ± 3.4 years, 6 males/16 females) were exposed to a probiotic intervention and a placebo for 4 weeks each, separated by a 4-week washout period. Subjects underwent functional magnetic resonance imaging while performing an emotional attention task after each intervention period. Differential brain activity and functional connectivity were assessed. Results: Altered brain responses were observed in brain regions implicated in emotional, cognitive and face processing. Increased activation in the orbitofrontal cortex, a region that receives extensive sensory input and in turn projects to regions implicated in emotional processing, was found after probiotic intervention compared to placebo using a cluster-based analysis of functionally defined areas. Significantly reduced task-related functional connectivity was observed after the probiotic intervention compared to placebo. Fecal microbiota composition was not majorly affected by probiotic intervention. Conclusion: The probiotic intervention resulted in subtly altered brain activity and functional connectivity in healthy subjects performing an emotional task without major effects on the fecal microbiota composition. This indicates that the probiotic effects occurred via microbe-host interactions on other levels. Further analysis of signaling molecules could give possible insights into the modes of action of the probiotic intervention on the gut-brain axis in general and brain function specifically. The presented findings further support the growing consensus that probiotic supplementation influences brain function and emotional regulation, even in healthy subjects. Future studies including patients with altered emotional processing, such as anxiety or depression symptoms are of great interest. Clinical Trial Registration: [http://clinicaltrials.gov/], identifier [NCT03615651].

17.
Nutrients ; 14(7)2022 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-35405944

RESUMO

Probiotics are suggested to impact physiological and psychological stress responses by acting on the gut-brain axis. We investigated if a probiotic product containing Bifidobacterium longum R0175, Lactobacillus helveticus R0052 and Lactiplantibacillus plantarum R1012 affected stress processing in a double-blinded, randomised, placebo-controlled, crossover proof-of-concept study (NCT03615651). Twenty-two healthy subjects (24.2 ± 3.4 years, 6 men/16 women) underwent a probiotic and placebo intervention for 4 weeks each, separated by a 4-week washout period. Subjects were examined by functional magnetic resonance imaging while performing the Montreal Imaging Stress Task (MIST) as well as an autonomic nervous system function assessment during the Stroop task. Reduced activation in regions of the lateral orbital and ventral cingulate gyri was observed after probiotic intervention compared to placebo. Significantly increased functional connectivity was found between the upper limbic region and medioventral area. Interestingly, probiotic intervention seemed to predominantly affect the initial stress response. Salivary cortisol secretion during the task was not altered. Probiotic intervention did not affect cognitive performance and autonomic nervous system function during Stroop. The probiotic intervention was able to subtly alter brain activity and functional connectivity in regions known to regulate emotion and stress responses. These findings support the potential of probiotics as a non-pharmaceutical treatment modality for stress-related disorders.


Assuntos
Bifidobacterium longum , Lactobacillus helveticus , Probióticos , Encéfalo/diagnóstico por imagem , Método Duplo-Cego , Feminino , Voluntários Saudáveis , Humanos , Masculino
18.
J Digit Imaging ; 24(3): 470-7, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20358243

RESUMO

The purpose of this work was to develop a visualization method for concurrent observation of both velocity and magnitude data obtained from through-plane velocity measurements using phase-contrast magnetic resonance imaging. Magnitude and velocity images were combined using an opacity transfer function (OTF) where the opacity was a function of a velocity range defined by the velocity encoding (v (enc)) parameter. Measured velocities were color-coded according to a predefined color scale and then combined into one image with the gray-scale magnitude image according to the OTF. In the combined images, simultaneous information of velocity and anatomy was presented. The proposed visualization method facilitated the understanding of how the measured blood flow was related to the underlying anatomy. Results are shown where the method is used to visualize blood flow measurements in the ascending aorta and the aortic valve. Adjustments of the OTF render possible identification of the peak velocities and their localization. Forward and backward blood flow is easily shown when applying appropriate OTF and color-coding. An advantage when using the proposed method is the ability of developing standardized protocol settings since the velocity information is quantitative and not relative as is the case for data obtained from the magnitude images. The intended application of the visualization method is the analysis of common flow studies used in the diagnosis of different cardiovascular diseases.


Assuntos
Aorta/anatomia & histologia , Valva Aórtica/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Fluxo Pulsátil , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Humanos , Imageamento Tridimensional/métodos
19.
Urolithiasis ; 49(1): 41-49, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32107579

RESUMO

The objectives were to develop and validate a Convolutional Neural Network (CNN) using local features for differentiating distal ureteral stones from pelvic phleboliths, compare the CNN method with a semi-quantitative method and with radiologists' assessments and to evaluate whether the assessment of a calcification and its local surroundings is sufficient for discriminating ureteral stones from pelvic phleboliths in non-contrast-enhanced CT (NECT). We retrospectively included 341 consecutive patients with acute renal colic and a ureteral stone on NECT showing either a distal ureteral stone, a phlebolith or both. A 2.5-dimensional CNN (2.5D-CNN) model was used, where perpendicular axial, coronal and sagittal images through each calcification were used as input data for the CNN. The CNN was trained on 384 calcifications, and evaluated on an unseen dataset of 50 stones and 50 phleboliths. The CNN was compared to the assessment by seven radiologists who reviewed a local 5 × 5 × 5 cm image stack surrounding each calcification, and to a semi-quantitative method using cut-off values based on the attenuation and volume of the calcifications. The CNN differentiated stones and phleboliths with a sensitivity, specificity and accuracy of 94%, 90% and 92% and an AUC of 0.95. This was similar to a majority vote accuracy of 93% and significantly higher (p = 0.03) than the mean radiologist accuracy of 86%. The semi-quantitative method accuracy was 49%. In conclusion, the CNN differentiated ureteral stones from phleboliths with higher accuracy than the mean of seven radiologists' assessments using local features. However, more than local features are needed to reach optimal discrimination.


Assuntos
Redes Neurais de Computação , Cólica Renal/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Cálculos Ureterais/diagnóstico , Calcificação Vascular/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Conjuntos de Dados como Assunto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pelve/irrigação sanguínea , Pelve/diagnóstico por imagem , Curva ROC , Cólica Renal/etiologia , Estudos Retrospectivos , Ureter/diagnóstico por imagem , Cálculos Ureterais/complicações , Calcificação Vascular/patologia , Veias/diagnóstico por imagem , Veias/patologia , Adulto Jovem
20.
Eur J Radiol Open ; 8: 100357, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34095355

RESUMO

BACKGROUND: Patients with transfusion dependent anemia are at risk of complications from iron overload. Quantitative T2* magnetic resonance imaging (MRI) is the best non-invasive method to assess iron deposition in the liver and heart and to guide chelation therapy. PURPOSE: To investigate the image quality and inter-observer variations in T2* measurements of the myocardium and the liver, and to obtain the lower limit of cardiac and hepatic quantitative T2* values in patients without suspicion of iron overload. MATERIAL AND METHODS: Thirty-eight patients referred for cardiac MRI were prospectively included in the study. Three patients were referred with, and 35 without suspicion of iron overload. Quantitative T2* parametric maps were obtained on a 1.5 T MRI system in the cardiac short axis and liver axial view. Two readers independently assessed the image quality and the representative and the lowest T2* value in the myocardium and the liver. RESULTS: The normal range of representative T2* values in the myocardium and liver was 24-45 ms and 14-37 ms, respectively. None of the 35 participants (0 %, 95 % confidence interval 0-11 %) in the normal reference group demonstrated representative T2* values below previously reported lower limits in the myocardium (20 ms) or the liver (8 ms). Focal myocardial areas with T2* values near the lower normal range, 19-20 ms, were seen in two patients. The readers generally reported good image quality. CONCLUSION: T2* imaging for assessing iron overload can be performed in a non-dedicated center with sufficient image quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA