Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Diabetes Metab Res Rev ; 40(2): e3684, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37395322

RESUMO

Breakfast consumption is generally considered a health-promoting habit for cardiometabolism, particularly with regard to chrononutrition. Glucose uptake is enhanced by proper insulin secretion triggered by the pancreatic clock, averting metabolic dysregulation related to insulin resistance. Breakfast skipping, in turn, is often considered a behaviour detrimental to health, in part due to putative inverse metabolic actions compared to breakfast consumption, such that breakfast skipping may promote circadian desynchrony. However, most ill health concerns about breakfast skipping are inferred from observational research, and recent well-controlled randomized clinical trials have shown benefits of breakfast skipping for cardiovascular risk factors. Accordingly, this review describes the effects of breakfast consumption versus breakfast skipping on cardiovascular risk factors (blood pressure and glycaemic and lipid indices). In addition, the view of breakfast consumption as an opportunity for functional food ingestion is considered to provide further insights into decision-making practice. Collectively, both breakfast consumption and breakfast skipping can be considered viable habits, but they depend on individual preferences, planning, and the specific foods being consumed or omitted. When consumed, breakfast should consist primarily of functional foods typical for this meal (e.g., eggs, dairy products, nuts, fruits, whole grains, coffee, tea, etc.). While breakfast consumption aligns with chrononutrition principles, breakfast skipping can contribute to a calorie deficit over time, which has the potential for widespread cardiometabolic benefits for patients with overweight/obesity. The concepts and practical considerations discussed in the present review may aid health care personnel in personalising breakfast consumption recommendations for diverse patient populations.


Assuntos
Desjejum , Doenças Cardiovasculares , Humanos , Desjejum/fisiologia , Alimento Funcional , Obesidade/etiologia , Promoção da Saúde , Doenças Cardiovasculares/prevenção & controle , Doenças Cardiovasculares/complicações , Comportamento Alimentar/fisiologia
2.
Br J Nutr ; 131(12): 2031-2038, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38618917

RESUMO

The purpose of this study was to compare single- and multi-frequency bioimpedance (BIA) devices against dual-energy X-ray absorptiometry (DXA) for appendicular lean mass (ALM) and muscle quality index (MQI) metrics in Hispanic adults. One hundred thirty-one Hispanic adults (18-55 years) participated in this study. ALM was measured with single-frequency bioimpedance analysis (SFBIA), multi-frequency bioimpedance analysis (MFBIA) and DXA. ALMTOTAL (left arm + right arm + left leg + right leg) and ALMARMS (left arm + right arm) were computed for all three devices. Handgrip strength (HGS) was measured using a dynamometer. The average HGS was used for all MQI models (highest left hand + highest right hand)/2. MQIARMS was defined as the ratio between HGS and ALMARMS. MQITOTAL was established as the ratio between HGS and ALMTOTAL. SFBIA and MFBIA had strong correlations with DXA for all ALM and MQI metrics (Lin's concordance correlation coefficient values ranged from 0·86 (MQIMFBIA-ARMS) to 0·97 (Arms LMSFBIA); all P < 0·001). Equivalence testing varied between methods (e.g. SFBIA v. DXA) when examining the different metrics (i.e. ALMTOTAL, ALMARMS, MQITOTAL and MQIARMS). MQIARMS was the only metric that did not differ from the line of identity and had no proportional bias when comparing all the devices against each other. The current study findings demonstrate good overall agreement between SFBIA, MFBIA and DXA for ALMTOTAL and ALMARMS in a Hispanic population. However, SFBIA and MFBIA have better agreement with DXA when used to compute MQIARMS than MQITOTAL.


Assuntos
Absorciometria de Fóton , Composição Corporal , Impedância Elétrica , Força da Mão , Hispânico ou Latino , Músculo Esquelético , Humanos , Adulto , Masculino , Feminino , Adulto Jovem , Pessoa de Meia-Idade , Adolescente , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia
3.
Br J Nutr ; 131(3): 461-473, 2024 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-37641937

RESUMO

Rhodiola rosea (RR) is a plant whose bioactive components may function as adaptogens, thereby increasing resistance to stress and improving overall resilience. Some of these effects may influence exercise performance and adaptations. Based on studies of rodents, potential mechanisms for the ergogenic effects of RR include modulation of energy substrate stores and use, reductions in fatigue and muscle damage and altered antioxidant activity. At least sixteen investigations in humans have explored the potential ergogenicity of RR. These studies indicate acute RR supplementation (∼200 mg RR containing ∼1 % salidroside and ∼3 % rosavin, provided 60 min before exercise) may prolong time-to-exhaustion and improve time trial performance in recreationally active males and females, with limited documented benefits of chronic supplementation. Recent trials providing higher doses (∼1500 to 2400 mg RR/d for 4­30 d) have demonstrated ergogenic effects during sprints on bicycle ergometers and resistance training in trained and untrained adults. The effects of RR on muscle damage, inflammation, energy system modulation, antioxidant activity and perceived exertion are presently equivocal. Collectively, it appears that adequately dosed RR enhances dimensions of exercise performance and related outcomes for select tasks. However, the current literature does not unanimously show that RR is ergogenic. Variability in supplementation dose and duration, concentration of bioactive compounds, participant characteristics, exercise tests and statistical considerations may help explain these disparate findings. Future research should build on the longstanding use of RR and contemporary clinical trials to establish the conditions in which supplementation facilitates exercise performance and adaptations.


Assuntos
Substâncias para Melhoria do Desempenho , Rhodiola , Masculino , Adulto , Feminino , Humanos , Extratos Vegetais/farmacologia , Extratos Vegetais/uso terapêutico , Antioxidantes/farmacologia , Rhodiola/química , Substâncias para Melhoria do Desempenho/farmacologia , Exercício Físico/fisiologia
4.
J Strength Cond Res ; 38(3): e104-e115, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38416450

RESUMO

ABSTRACT: Bongiovanni, T, Lacome, M, Rodriguez, C, and Tinsley, GM. Tracking body composition over a competitive season in elite soccer players using laboratory- and field-based assessment methods. J Strength Cond Res 38(3): e104-e115, 2024-The purpose of this study was to describe body composition changes in professional soccer players over the course of a competitive playing season and compare the ability of different assessment methods to detect changes. Twenty-one elite male soccer players (age: 23.7 ± 4.8 years; height: 185.0 ± 5.2 cm; body mass: 80.7 ± 5.5 kg; body fat: 12.8 ± 2.2%) playing for an Italian national second league (Serie B) championship team were assessed at 4 time points throughout a competitive season: T0 (mid-October), T1 (mid-December), T2 (mid-February), and T3 (end of April). Dual-energy x-ray absorptiometry (DXA), skinfolds (SKF), and bioelectrical impedance analysis were performed at each time point, and multiple SKF-based equations were applied. A modified 4-compartment (4C) model was also produced. Data were analyzed using repeated measures analysis of variance, relevant post hoc tests, and Pearson's correlations. Dual-energy x-ray absorptiometry, 4C, and the SKF-based equations of Reilly and Civar detected differences in fat-free mass (FFM) between time points, with the most differences observed for DXA. Fat-free mass increased from T0 values to a peak at T2, followed by a decrease by T3, although FFM values remained higher than T0. Fat-free mass gain was primarily driven by increases in the lower limbs. Fat-free mass changes between all methods were significantly correlated, with correlation coefficients of 0.70-0.97. No significant differences between time points were observed for absolute fat mass or body fat percentage, although significant correlations between several methods for change values were observed. Select laboratory and field methods can detect changes in FFM over the course of a season in elite, professional soccer athletes, with a more limited ability to detect changes in adiposity-related variables. For SKF in this population, the equation of Reilly is recommended.


Assuntos
Futebol , Humanos , Masculino , Adolescente , Adulto Jovem , Adulto , Estações do Ano , Composição Corporal , Tecido Adiposo , Absorciometria de Fóton
5.
J Nutr ; 153(8): 2154-2162, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37414360

RESUMO

BACKGROUND: A rapid 4-compartment (4C) model integrates dual-energy x-ray absorptiometry (DXA) and multi-frequency bioimpedance analysis (MFBIA), which may be useful for clinical and research settings seeking to employ a multi-compartment model. OBJECTIVES: This study aimed to determine the added benefit of a rapid 4C model over stand-alone DXA and MFBIA when estimating body composition. METHODS: One hundred and thirty participants (n = 60 male; n = 70 female) of Hispanic descent were included in the present analysis. A criterion 4C model that employed air displacement plethysmography (body volume), deuterium oxide (total body water), and DXA (bone mineral) was used to measure fat mass (FM), fat-free mass (FFM), and body fat percent (%BF). A rapid 4C model (DXA-derived body volume and bone mineral; MFBIA-derived total body water) and stand-alone DXA (GE Lunar Prodigy) and MFBIA (InBody 570) assessments were compared against the criterion 4C model. RESULTS: Lin's concordance correlation coefficient values were >0.90 for all comparisons. The standard error of the estimates ranged from 1.3 to 2.0 kg, 1.6 to 2.2 kg, and 2.1 to 2.7% for FM, FFM, and %BF, respectively. The 95% limits of agreement ranged from ±3.0 to 4.2 kg, ±3.1 to 4.2 kg, and ±4.9 to 5.2% for FM, FFM, and %BF, respectively. CONCLUSIONS: Results revealed that all 3 methods provided acceptable body composition results. The MFBIA device used in the current study may be a more economically friendly option than DXA or when there is a need to minimize radiation exposure. Nonetheless, clinics and laboratories that already have a DXA device in place or that value having the lowest individual error when conducting a test may consider continuing to use the machine. Lastly, a rapid 4C model may be useful for assessing body composition measures observed in the current study and those provided by a multi-compartment model (e.g., protein).


Assuntos
Tecido Adiposo , Composição Corporal , Adulto , Humanos , Masculino , Feminino , Tecido Adiposo/metabolismo , Absorciometria de Fóton/métodos , Hispânico ou Latino , Minerais/metabolismo , Impedância Elétrica , Reprodutibilidade dos Testes
6.
Br J Nutr ; 130(6): 1077-1087, 2023 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-36632007

RESUMO

Automated visual anthropometrics produced by mobile applications are accessible and cost effective with the potential to assess clinically relevant anthropometrics without a trained technician present. Thus, the aim of this study was to evaluate the precision and agreement of smartphone-based automated anthropometrics against reference tape measurements. Waist and hip circumference (WC; HC), waist:hip ratio (WHR) and waist:height ratio (W:HT) were collected from 115 participants (69 F) using a tape measure and two smartphone applications (MeThreeSixty®, myBVI®) across multiple smartphone types. Precision metrics were used to assess test-retest precision of the automated measures. Agreement between the circumferences produced by each mobile application and the reference were assessed using equivalence testing and other validity metrics. All mobile applications across smartphone types produced reliable estimates for each variable with intraclass correlation coefficients ≥ 0·93 (all P < 0·001) and root mean square coefficient of variation between 0·5 and 2·5 %. Precision error for WC and HC was between 0·5 and 1·9 cm. WC, HC, and W:HT estimates produced by each mobile application demonstrated equivalence with the reference tape measurements using 5 % equivalence regions. Mean differences via paired t-tests were significant for all variables across each mobile application (all P < 0·050) showing slight underestimation for WC and slight overestimation for HC which resulted in a lack of equivalence for WHR compared with the reference tape measure. Overall, the results of our study support the use of WC and HC estimates produced from automated mobile applications, but also demonstrates the importance of accurate automation for WC and HC estimates given their influence on other anthropometric assessments and clinical health markers.


Assuntos
Smartphone , Humanos , Antropometria , Relação Cintura-Quadril , Circunferência da Cintura , Índice de Massa Corporal
7.
Br J Nutr ; 130(3): 525-535, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-36268732

RESUMO

Assessments of visceral adipose tissue (VAT) are critical in preventing metabolic disorders; however, there are limited measurement methods that are accurate and accessible for VAT. The purpose of this cross-sectional study was to evaluate the association between VAT estimates from consumer-grade devices and traditional anthropometrics and VAT and subcutaneous adipose tissue (SAT) from dual-energy X-ray absorptiometry (DXA). Data were collected from 182 participants (female = 114; White = 127; Black/African-American (BAA) = 48) which included anthropometrics and indices of VAT produced by near-infrared reactance spectroscopy (NIRS), visual body composition (VBC) and multifrequency BIA (MFBIA). VAT and SAT were collected using DXA. Bivariate and partial correlations were calculated between DXAVAT and DXASAT and other VAT estimates. All VAT indices had positive moderate-strong correlations with VAT (all P < 0·001) and SAT (all P < 0·001). Only waist:hip (r = 0·69), VATVBC (r = 0·84), and VATMFBIA (r = 0·86) had stronger associations with VAT than SAT (P < 0·001). Partial associations between VATVBC and VATMFBIA were only stronger for VAT than SAT in White participants (r = 0·67, P < 0·001) but not female, male, or BAA participants individually. Partial correlations for waist:hip were stronger for VAT than SAT, but only for male (r = 0·40, P < 0·010) or White participants (r = 0·48, P < 0·001). NIRS was amongst the weakest predictors of VAT which was highest in male participants (r = 0·39, P < 0·010) but non-existent in BAA participants (r = -0·02, P > 0·050) after adjusting for SAT. Both anthropometric and consumer-grade VAT indices are consistently better predictors of SAT than VAT. These data highlight the need for a standardised, but convenient, VAT estimation protocol that can account for the relationship between SAT and VAT that differs by sex/race.


Assuntos
Gordura Intra-Abdominal , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Gordura Intra-Abdominal/diagnóstico por imagem , Absorciometria de Fóton/métodos , Estudos Transversais , Composição Corporal , Tecido Adiposo
8.
Br J Nutr ; 130(5): 827-840, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-36404739

RESUMO

The purpose of this investigation was to expand upon the limited existing research examining the test-retest reliability, cross-sectional validity and longitudinal validity of a sample of bioelectrical impedance analysis (BIA) devices as compared with a laboratory four-compartment (4C) model. Seventy-three healthy participants aged 19-50 years were assessed by each of fifteen BIA devices, with resulting body fat percentage estimates compared with a 4C model utilising air displacement plethysmography, dual-energy X-ray absorptiometry and bioimpedance spectroscopy. A subset of thirty-seven participants returned for a second visit 12-16 weeks later and were included in an analysis of longitudinal validity. The sample of devices included fourteen consumer-grade and one research-grade model in a variety of configurations: hand-to-hand, foot-to-foot and bilateral hand-to-foot (octapolar). BIA devices demonstrated high reliability, with precision error ranging from 0·0 to 0·49 %. Cross-sectional validity varied, with constant error relative to the 4C model ranging from -3·5 (sd 4·1) % to 11·7 (sd 4·7) %, standard error of the estimate values of 3·1-7·5 % and Lin's concordance correlation coefficients (CCC) of 0·48-0·94. For longitudinal validity, constant error ranged from -0·4 (sd 2·1) % to 1·3 (sd 2·7) %, with standard error of the estimate values of 1·7-2·6 % and Lin's CCC of 0·37-0·78. While performance varied widely across the sample investigated, select models of BIA devices (particularly octapolar and select foot-to-foot devices) may hold potential utility for the tracking of body composition over time, particularly in contexts in which the purchase or use of a research-grade device is infeasible.


Assuntos
Composição Corporal , Humanos , Reprodutibilidade dos Testes , Impedância Elétrica , Estudos Transversais , Absorciometria de Fóton/métodos
9.
J Hum Nutr Diet ; 36(3): 905-911, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36451080

RESUMO

BACKGROUND: Digital imaging analysis (DIA) estimates collected from mobile applications comprise a novel technique that can collect body composition estimates remotely without the inherent restrictions of other research-grade devices. However, the accuracy of the artificial intelligence used in DIA is reliant on the accuracy of the developmental methods. Few DIA applications are trained by multicompartment models, but this developmental strategy may be most accurate. Thus, the aim of the present study was to assess the precision and agreement of a DIA application with developmental software trained by a four-compartment (4C) model using an actual 4C model as the criterion method. METHODS: For this cross-sectional study, body composition estimations were collected from 102 participants (63 females, 39 males) using the methods necessary for a rapid 4C model and a DIA application using two different smartphones. RESULTS: Intraclass correlation coefficients (0.96-0.99; all p < 0.001) and root mean square coefficients of variation (0.5%-3.0%) showed good reliability for body fat percentage, fat mass and fat-free mass. There were no significant mean differences between the 4C model or the DIA estimates for the total sample, by sex, and for non-Hispanic White (n = 61) and Black/African-American (n = 32) participants (all p > 0.050). DIA estimates demonstrated equivalence with the 4C model for all variables but revealed proportional biases that underestimated body fat percentage (both ß = -0.25; p < 0.001) and fat mass (both ß = -0.07; p < 0.010) at higher degrees of each variable. CONCLUSIONS: DIA applications trained by a 4C model are reliable and produce body composition estimates equivalent to an actual 4C model.


Assuntos
Inteligência Artificial , Composição Corporal , Masculino , Feminino , Humanos , Absorciometria de Fóton/métodos , Estudos Transversais , Reprodutibilidade dos Testes , Tecido Adiposo , Impedância Elétrica
10.
J Strength Cond Res ; 37(8): e444-e454, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37184967

RESUMO

ABSTRACT: Escalante, G, Barakat, C, Tinsley, GM, and Schoenfeld, BJ. Nutrition, training, supplementation, and performance-enhancing drug practices of male and female physique athletes peaking for competition. J Strength Cond Res 37(8): e444-e454, 2023-The purpose of this descriptive investigation was threefold: (a) to assess the nutrition, training, supplement, and performance-enhancement drug practices of male and female physique competitors 30 days before competition; (b) to examine the specific water and macronutrient manipulation performed by competitors during the last 3 days before competition; and (c) to assess physiological responses to precontest preparation including body composition, body fluids, resting heart rate, and blood pressure. Competitors reported performing moderately high volume, moderate to high repetition, split-body resistance training programs performed on most days of the week; the programs included the use of a variety of advanced training methods. A majority of competitors included cardio to expedite fat loss, and most reported performing cardio in a fasted state despite a lack of objective evidentiary support for the practice. Competitors substantially restricted calories and consumed protein in amounts well above research-based guidelines (>3 g·kg -1 ·d -1 ); carbohydrate and lipid intake were highly variable. Water was substantially reduced in the final 3 days before competition. Competitors used a variety of dietary supplements throughout the study period, many of which are not supported by research. Both male and female competitors reported using performance enhancing drugs (∼48 and ∼38%, respectively) including testosterone derivatives, selective androgen receptor modulators, and human growth hormone. More research is warranted to elucidate safer and more effective peak week practices for physique competitors.


Assuntos
Substâncias para Melhoria do Desempenho , Humanos , Masculino , Feminino , Estado Nutricional , Atletas , Suplementos Nutricionais , Água
11.
J Strength Cond Res ; 37(5): 1042-1051, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730583

RESUMO

ABSTRACT: Rodriguez, C, Florez, CM, Prather, J, Zaragoza, J, Tinnin, M, Brennan, KL, Taylor, L, and Tinsley, GM. Influence of upper-extremity and lower-extremity resistance exercise on segmental body composition and body fluid estimates. J Strength Cond Res 37(5): 1042-1051, 2023-The purpose of this analysis was to determine if acute, localized resistance exercise (RE) artificially influences total and regional estimates of body composition from dual-energy X-ray absorptiometry (DXA) and bioelectrical impedance analysis (BIA). Recreationally active male ( n = 14) and female ( n = 18) subjects completed 3 testing visits: rest (R), upper-extremity RE (U), and lower-extremity RE (L). Dual-energy X-ray absorptiometry scans were completed before exercise and 60 minutes after exercise. Bioelectrical impedance analysis was completed immediately before and after exercise and at 15, 30, and 60 minutes after exercise. Subjects were not allowed to intake fluid during the exercise session or during the postexercise assessment period. The effects of the acute RE session on DXA and BIA estimates were analyzed using linear mixed-effects models with a random intercept for subject. Condition by time interactions were observed for most BIA outcomes. Relative to the reference model (i.e., R condition at baseline), total body water and fat-free mass estimates were, on average, approximately 1 and approximately 1.2 kg higher, in the U condition. In contrast, lower-extremity RE exerted little or no impact on most BIA variables. Some DXA estimates exhibited time main effects, but the magnitude of changes was negligible. An acute bout of localized RE, particularly upper-extremity RE, can artificially influence BIA body fluid and composition estimates, whereas DXA may be robust to the acute biological error introduced by RE. Although body composition assessments should ideally be conducted under standardized conditions, DXA may be suitable in less standardized situations. In addition, BIA is differentially influenced by upper-extremity and lower-extremity resistance exercise.


Assuntos
Líquidos Corporais , Treinamento Resistido , Humanos , Masculino , Feminino , Composição Corporal , Exercício Físico , Absorciometria de Fóton , Impedância Elétrica , Extremidades , Índice de Massa Corporal
12.
Crit Rev Food Sci Nutr ; 62(2): 466-474, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-32935557

RESUMO

"Eat breakfast like a king, lunch like a prince and dinner like a pauper" (Adelle Davis, 1904-1974) is a concept that appears to align with some contemporary evidence concerning the appropriate proportioning of daily meals. At the same time, with the popular and scientific dissemination of the concepts of intermittent fasting and time-restricted feeding, well-controlled clinical trials have emerged showing the safety or even possible benefits of skipping breakfast. In this comprehensive literature review, we discuss recent evidence regarding breakfast intake, cardiovascular outcomes and cardiovascular risk markers. Overall, breakfast omission appears to be associated with a higher risk for atherosclerotic and adverse cardiovascular outcomes. However, caution should be employed when deciphering these data as many complex, unmeasured confounders may have contributed. Unfortunately, long-term randomized, clinical trials with detailed dietary control that have assessed clinical outcomes are sparse. Notwithstanding the observational findings, current trials conducted so far-albeit apparently smaller number-have shown that breakfast addition in subjects who do not habitually consume this meal may increase body weight, particularly fat mass, through caloric excess, whereas skipping breakfast may be a feasible strategy for some people aiming for calorie restriction. To date, definitive benefits of breakfast omission or consumption are not supported by the best evidence-based research, and the question of whether skipping breakfast per se is causally associated with cardiovascular outcomes remains unresolved.


Assuntos
Desjejum , Doenças Cardiovasculares , Doenças Cardiovasculares/prevenção & controle , Comportamento Alimentar , Humanos , Almoço , Refeições
13.
Crit Rev Food Sci Nutr ; 62(21): 5717-5732, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33624538

RESUMO

We evaluated the effects of ketogenic diets (KDs) on body mass (BM), fat mass (FM), fat-free mass (FFM), body mass index (BMI), and body fat percentage (BFP) compared to non-KDs in individuals performing resistance training (RT). Online electronic databases including PubMed, the Cochrane Library, Web of Science, Embase, SCOPUS, and Ovid were searched to identify initial studies until February 2021. Data were pooled using both fixed and random-effects methods and were expressed as weighted mean difference (WMD) and 95% confidence intervals (CI). Out of 1372 studies, 13 randomized controlled trials (RCTs) that enrolled 244 volunteers were included. The pooled results demonstrated that KDs significantly decreased BM [(WMD = -3.67 kg; 95% CI: -4.44, -2.90, p < 0.001)], FM [(WMD = -2.21 kg; 95% CI: -3.09, -1.34, p < 0.001)], FFM [(WMD = -1.26 kg; 95% CI: -1.82, -0.70, p < 0.001)], BMI [(WMD = -1.37 kg.m-2; 95% CI: -2.14, -0.59, p = 0.022)], and BFP [(WMD = -2.27%; 95% CI: -3.63, -0.90, p = 0.001)] compared to non-KDs. We observed beneficial effects of KDs compared to non-KDs on BM and body fat (both FM and BFP) in individuals performing RT. However, adherence to KDs may have a negative effect on FFM, which is not ameliorated by the addition of RT.


Assuntos
Dieta Cetogênica , Treinamento Resistido , Tecido Adiposo , Composição Corporal , Índice de Massa Corporal , Dieta Cetogênica/métodos , Humanos
14.
Crit Rev Food Sci Nutr ; 62(23): 6516-6533, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33764214

RESUMO

Controversy regarding the effects of betaine supplementation on cardiovascular markers has persisted for decades. This systematic review and meta-analysis compared the effects of betaine supplementation on cardiovascular disease (CVD) markers. Studies examining betaine supplementation on CVD markers published up to February 2021 were identified through PubMed, the Cochrane Library, Web of Science, Embase, and SCOPUS. Betaine supplementation had a significant effect on concentrations of betaine (MD: 82.14 µmol/L, 95% CI: 67.09 to 97.20), total cholesterol (TC) (MD: 14.12 mg/dl, 95% CI%: 9.23 to 19.02), low-density lipoprotein (LDL) (MD: 10.26 mg/dl, 95% CI: 6.14 to 14.38)], homocysteine (WMD: -1.30 micromol/L, 95% CI: -1.61 to -0.98), dimethylglycine (DMG) (MD: 21.33 micromol/L, 95% CI: 13.87 to 28.80), and methionine (MD: 2.06 micromol/L, 95% CI: 0.23 to 3.88). Moreover, our analysis indicated that betaine supplementation did not affect serum concentrations of triglyceride (TG), high-density lipoprotein (HDL), fasting blood glucose (FBG), C-reactive protein (CRP), liver enzymes [alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyl transferase (GGT)], and blood pressure. Our subgroup analysis suggested that a maximum dose of 4 g/d might have homocysteine-lowering effects without any adverse effect on lipid profiles reported with doses of ≥4 g/d. In conclusion, the present systematic review and meta-analysis supports the advantage of a lower dose of betaine supplementation (<4 g/d) on homocysteine concentrations without the lipid-augmenting effect observed with a higher dosage.


Assuntos
Betaína , Doenças Cardiovasculares , Betaína/farmacologia , Biomarcadores , Doenças Cardiovasculares/prevenção & controle , Suplementos Nutricionais , Homocisteína , Humanos , Triglicerídeos
15.
Br J Nutr ; 127(11): 1656-1674, 2022 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34325758

RESUMO

The present study reports the validity of multiple assessment methods for tracking changes in body composition over time and quantifies the influence of unstandardised pre-assessment procedures. Resistance-trained males underwent 6 weeks of structured resistance training alongside a hyperenergetic diet, with four total body composition evaluations. Pre-intervention, body composition was estimated in standardised (i.e. overnight fasted and rested) and unstandardised (i.e. no control over pre-assessment activities) conditions within a single day. The same assessments were repeated post-intervention, and body composition changes were estimated from all possible combinations of pre-intervention and post-intervention data. Assessment methods included dual-energy X-ray absorptiometry (DXA), air displacement plethysmography, three-dimensional optical imaging, single- and multi-frequency bioelectrical impedance analysis, bioimpedance spectroscopy and multi-component models. Data were analysed using equivalence testing, Bland-Altman analysis, Friedman tests and validity metrics. Most methods demonstrated meaningful errors when unstandardised conditions were present pre- and/or post-intervention, resulting in blunted or exaggerated changes relative to true body composition changes. However, some methods - particularly DXA and select digital anthropometry techniques - were more robust to a lack of standardisation. In standardised conditions, methods exhibiting the highest overall agreement with the four-component model were other multi-component models, select bioimpedance technologies, DXA and select digital anthropometry techniques. Although specific methods varied, the present study broadly demonstrates the importance of controlling and documenting standardisation procedures prior to body composition assessments across distinct assessment technologies, particularly for longitudinal investigations. Additionally, there are meaningful differences in the ability of common methods to track longitudinal body composition changes.


Assuntos
Composição Corporal , Humanos , Masculino , Impedância Elétrica , Reprodutibilidade dos Testes , Antropometria/métodos , Absorciometria de Fóton/métodos
16.
Br J Nutr ; 128(5): 975-988, 2022 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34743773

RESUMO

Previous studies evaluating the effects of betaine supplementation on body composition offer contradictory findings. This systematic review and meta-analysis assessed the effects of betaine supplementation on body composition indices (body mass (BM), BMI, body fat percentage (BFP), fat mass (FM), fat-free mass (FFM)), and dietary intakes. Studies examining the effects of betaine supplementation on body composition and dietary intakes published up to August 2021 were identified through PubMed, the Cochrane Library, Web of Science, Embase, SCOPUS and Ovid databases. Betaine supplementation failed to significantly affect BM ((weighted mean difference (WMD): -0·40 kg, 95 % CI -1·46, 0·64), P = 0·447), BMI ((WMD: -0·05 kg/m2, 95 % CI -0·36, 0·25), P = 0·719), BFP ((WMD: 0·26 %, 95 % CI -0·82, 1·36), P = 0·663), FM ((WMD: -0·57 kg, 95 % CI -2·14, 0·99), P = 0·473) and FFM ((WMD: 0·61 kg, 95 % CI -1·27, 2·49), P = 0·527). Subgroup analyses based on participant's age (< 40 and > 40 years), sex, BMI, trial duration (< 8 and ≥ 8 weeks), betaine supplementation dosage (< 4 and ≥ 4 g) and health status (healthy or unhealthy) demonstrated similar results. Other than a potential negligible increase in protein intake (WMD: 3·56 g, 95 % CI 0·24, 6·88, P = 0·035), no changes in dietary intakes were observed following betaine supplementation compared with control. The present systematic review and meta-analysis does not show any beneficial effects of betaine supplementation on body composition indices (BM, BMI, FM and FFM).


Assuntos
Betaína , Suplementos Nutricionais , Adulto , Humanos , Composição Corporal , Peso Corporal
17.
Br J Nutr ; : 1-11, 2022 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-35109945

RESUMO

Few investigations have evaluated the validity of current body composition technology among racially and ethnically diverse populations. This study assessed the validity of common body composition methods in a multi-ethnic sample stratified by race and ethnicity. One hundred and ten individuals (55 % female, age: 26·5 (sd 6·9) years) identifying as Asian, African American/Black, Caucasian/White, Hispanic, Multi-racial and Native American were enrolled. Seven body composition models (dual-energy X-ray absorptiometry (DXA), air displacement plethysmography (ADP), two bioelectrical impedance devices (BIS, IB) and three multi-compartment models) were evaluated against a four-compartment criterion model by assessing total error (TE) and standard error of the estimate. For the total sample, measures of % fat and fat-free mass (FFM) from multi-compartment models were all excellent to ideal (% fat: TE = 0·94-2·37 %; FFM: TE = 0·72-1·78 kg) compared with the criterion. % fat measures were very good to excellent for DXA, ADP and IB (TE = 2·52-2·89 %) and fairly good for BIS (TE = 4·12 %). For FFM, single device estimates were good (BIS; TE = 3·12 kg) to ideal (DXA, ADP, IB; TE = 1·21-2·15 kg). Results did not vary meaningfully between each race and ethnicity, except BIS was not valid for African American/Black, Caucasian/White and Multi-racial participants for % fat (TE = 4·3-4·9 %). The multi-compartment models evaluated can be utilised in a multi-ethnic sample and in each individual race and ethnicity to obtain highly valid results for % fat and FFM. Estimates from DXA, ADP and IB were also valid. The BIS may demonstrate greater TE for all racial and ethnic cohorts and results should be interpreted cautiously.

18.
Br J Nutr ; : 1-13, 2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35614845

RESUMO

This exploratory study investigated the effects of early v. delayed time-restricted eating (TRE) plus caloric restriction (CR) on body weight, body composition and cardiometabolic parameters in adults with overweight and obesity. Adults (20-40 years) were randomised to one of three groups for 8 weeks: early time-restricted eating (eTRE; 08.00-16.00) plus CR, delayed time-restricted eating (dTRE; 12.00-20.00) plus CR or only CR (CR; 08.00-20.00). All groups were prescribed a 25 % energy deficit relative to daily energy requirements. Thirteen participants completed the study in the eTRE and CR groups and eleven in the dTRE group (n 37). After the interventions, there was no significant difference between the three groups for any of the outcomes. Compared with baseline, significant decreases were observed in the body weight (eTRE group: -4·2 kg; 95 % CI, -5·6, -2·7; dTRE group: -4·8 kg; 95 % CI, -5·9, -3·7; CR: -4·0 kg; 95 % CI, -5·9, -2·1), fat mass (eTRE group: -2·9 kg; 95 % CI, -3·9, -1·9; dTRE group: -3·6 kg; 95 % CI, -4·6, -2·5; CR: -3·1 kg; 95 % CI, -4·3, -1·8) and fasting glucose levels (eTRE group: -4 mg/dl; 95 % CI, -8, -1; dTRE group: -2 mg/dl; 95 % CI, -8, 3; CR: -3 mg/dl; 95 % CI, -8, 2). In a free-living setting, TRE with a energetic deficit, regardless of the time of day, promotes similar benefits in weight loss, body composition and cardiometabolic parameters. However, given the exploratory nature of our study, further investigation is needed to confirm these findings.

19.
J Strength Cond Res ; 36(12): 3551-3561, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34593729

RESUMO

ABSTRACT: Harty, PS, Friedl, KE, Nindl, BC, Harry, JR, Vellers, HL, and Tinsley, GM. Military body composition standards and physical performance: historical perspectives and future directions. J Strength Cond Res 36(12): 3551-3561, 2022-US military physique and body composition standards have been formally used for more than 100 years. These metrics promote appropriate physical fitness, trim appearance, and long-term health habits in soldiers, although many specific aspects of these standards have evolved as evidence-based changes have emerged. Body composition variables have been shown to be related to many physical performance outcomes including aerobic capacity, muscular endurance, strength and power production, and specialized occupational tasks involving heavy lifting and load carriage. Although all these attributes are relevant, individuals seeking to improve military performance should consider emphasizing strength, hypertrophy, and power production as primary training goals, as these traits appear vital to success in the new Army Combat Fitness Test introduced in 2020. This fundamental change in physical training may require an adjustment in body composition standards and methods of measurement as physique changes in modern male and female soldiers. Current research in the field of digital anthropometry (i.e., 3-D body scanning) has the potential to dramatically improve performance prediction algorithms and potentially could be used to inform training interventions. Similarly, height-adjusted body composition metrics such as fat-free mass index might serve to identify normal weight personnel with inadequate muscle mass, allowing for effective targeted nutritional and training interventions. This review provides an overview of the origin and evolution of current US military body composition standards in relation to military physical readiness, summarizes current evidence relating body composition parameters to aspects of physical performance, and discusses issues relevant to the emerging modern male and female warrior.


Assuntos
Militares , Masculino , Feminino , Humanos , Aptidão Física/fisiologia , Composição Corporal/fisiologia , Teste de Esforço/métodos , Estatura , Força Muscular/fisiologia , Resistência Física/fisiologia
20.
J Strength Cond Res ; 36(11): 3093-3104, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34172636

RESUMO

ABSTRACT: Rodriguez, C, Harty, PS, Stratton, MT, Siedler, MR, Smith, RW, Johnson, BA, Dellinger, JR, Williams, AD, White, SJ, Benavides, ML, and Tinsley, GM. Comparison of indirect calorimetry and common prediction equations for evaluating changes in resting metabolic rate induced by resistance training and a hypercaloric diet. J Strength Cond Res 36(11): 3093-3104, 2022-The ability to accurately identify resting metabolic rate (RMR) changes over time allows practitioners to prescribe appropriate adjustments to nutritional intake. However, there is a lack of data concerning the longitudinal utility of commonly used RMR prediction equations. The purpose of this study was to evaluate the validity of several commonly used prediction equations to track RMR changes during a hypercaloric nutritional intervention and supervised resistance exercise training program. Twenty resistance-trained men completed the study. The protocol lasted 6 weeks, and subjects underwent RMR assessments by indirect calorimetry (IC) preintervention and postintervention to obtain reference values. Existing RMR prediction equations based on body mass (BM) or dual-energy X-ray absorptiometry fat-free mass (FFM) were also evaluated. Equivalence testing was used to evaluate whether each prediction equation demonstrated equivalence with IC. Null hypothesis significance testing was also performed, and Bland-Altman analysis was used alongside linear regression to assess the degree of proportional bias. Body mass and FFM increased by 3.6 ± 1.7 kg and 2.4 ± 1.6 kg, respectively. Indirect calorimetry RMR increased by 165 ± 97 kcal·d -1 , and RMR:FFM increased by 5.6 ± 5.2%. All prediction equations underestimated mean RMR changes relative to IC, with magnitudes ranging from 75 to 155 kcal·d -1 , while also displaying unacceptable levels of negative proportional bias. In addition, no equation demonstrated equivalence with IC. Common RMR prediction equations based on BM or FFM did not fully detect the increase in RMR observed with resistance training plus a hypercaloric diet. Overall, the evaluated prediction equations are unsuitable for estimating RMR changes in the context of this study.


Assuntos
Metabolismo Basal , Treinamento Resistido , Masculino , Humanos , Calorimetria Indireta/métodos , Absorciometria de Fóton , Dieta , Composição Corporal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA