Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Proteome Sci ; 11(1): 38, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-23915316

RESUMO

BACKGROUND: Cell surface glycoprotein sialylation is one of the most ubiquitous glycan modifications found on higher eukaryotes. The surface sialylation pattern of cells is influenced by the cellular environment but also by the Golgi sialyltransferase activity and flux of metabolites through sialic acid producing pathways. Altered cell surface sialic acid patterns have been observed in several cancers and other pathological conditions. In this experiment we examined the cellular proteomic changes that occur in human embryonic kidney cells after 24 hours of sialic acid overproduction using N-Acetylmannosamine. We utilized high resolution mass spectrometry and label free protein quantification to characterize the relative changes in protein abundance as well as multiple reaction monitoring to quantify the cellular sialic acid levels. RESULTS: Using N-Acetylmannosamine we were able to induce sialic acid production to almost 70-fold compared to non-induced control cells. Mass spectrometric analysis of cellular proteome of control and induced cells identified 1802 proteins of which 105 displayed significant changes in abundance. Functional analysis of the resulting relative changes in protein abundance revealed regulation of several cellular pathways including protein transport, metabolic and signaling pathways and remodeling of epithelial adherens junctions. We also identified several physically interacting co-regulated proteins in the set of changed proteins. CONCLUSIONS: In this experiment we show that increased metabolic flux through sialic acid producing pathway affects the abundance of several protein transport, epithelial adherens junction, signaling and metabolic pathway related proteins.

2.
Clin Chim Acta ; 515: 96-103, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33460593

RESUMO

BACKGROUND AND AIMS: Ten UriSed 3 PRO automated microscopes (77 Elektronika, Hungary) were verified for nine HUSLAB laboratories with 160 000 annual urine samples. MATERIALS AND METHODS: Particle counting of the primary UriSed 3 PRO instrument (77 Elektronika, Hungary) was verified against reference visual microscopy with 463 urine specimens, and against urine culture on chromogenic agar plates with parallel 396 specimens. Nine secondary instruments were compared pairwise with the primary instrument. RESULTS: Relative imprecisions compared to Poisson distribution, R(CV), were estimated to be 1.0 for white blood cell (WBC) and 1.5 for red blood cell (RBC) counts, respectively. Spearman's correlations against visual microscopy were rS = 0.94 for WBC, rS = 0.87 for RBC, and rS = 0.82 for squamous epithelial cell (SEC) counts. Agreement with visual microscopy (Cohen's weighted kappa) was 0.94 for WBC, 0.89 for RBC, 0.88 for SEC, 0.59 for combined casts, and 0.49 for non-squamous epithelial cells (NEC). Bacteria were detected with a sensitivity of 90% and specificity of 39 against culture at 107 CFB/L (104 CFU/mL). Created flagging limits allowed automated reporting for 70-75% of patient results. CONCLUSIONS: UriSed 3 PRO instruments were adopted into routine use after acceptance of the verification.


Assuntos
Laboratórios , Microscopia , Humanos , Hungria , Reprodutibilidade dos Testes , Urinálise , Urina
3.
Clin Chim Acta ; 516: 149-156, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33549597

RESUMO

BACKGROUND AND AIMS: We assessed the possibility to rule out negative urine cultures by counting with UriSed 3 PRO (77 Elektronika, Hungary) at Helsinki and Uusimaa Hospital District. MATERIALS AND METHODS: Bacteria counting of the UriSed 3 PRO automated microscope was verified with reference phase contrast microscopy against growth in culture. After acceptance into routine, results of bacteria and leukocyte counting from 56 426 specimens with eight UriSed 3 PRO instruments were compared against results from parallel samples cultured on chromogenic agar. Laboratory data including preanalytical details were accessed through the regional database of the Helsinki and Uusimaa Hospital District. RESULTS: A combined sensitivity of 87-92% and a negative predictive value of 90-96% with a specificity of 54-50% was reached, depending on criteria. Preanalytical data (incubation time in bladder) combined with the way of urine collection would improve these figures if reliable. CONCLUSIONS: Complex patient populations, regional logistics and data interfases, and economics related to increased costs of additional particle counts against costs of screening cultures of all samples, did not support adaptation of a screening process of urine cultures. This conclusion was made locally, and may not be valid elsewhere.


Assuntos
Bacteriúria , Infecções Urinárias , Bacteriúria/diagnóstico , Humanos , Hungria , Laboratórios , Microscopia , Sensibilidade e Especificidade , Urinálise , Urina
4.
Clin Chim Acta ; 493: 20-24, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30802439

RESUMO

BACKGROUND: Bradykinin is an important mediator of inflammation and vascular permeability and could have an important role in the development of septic shock. Measurement of bradykinin by immunological methods may suffer from interference and lack of specificity. We developed and validated a liquid chromatography mass spectrometry assay (LC-MS/MS) for plasma bradykinin. METHODS: We used plasma samples from healthy volunteers (n = 19) and patients with septic shock (n = 47). Stable isotope bradykinin internal standard was added to samples before solid-phase extraction and quantification by LC-MS/MS. Stability of bradykinin was studied for 12 months. RESULTS: Our assay has good sensitivity (0.1 nmol/l) and a wide linear range (0.1-1000 nmol/l). Bradykinin added to plasma was stable for 12 months at -20 °C when a mixture of protease inhibitors was added at sampling but degraded during repeated freezing and thawing. Bradykinin concentration in plasma from septic shock patients (<0.1-0.6 nmol/l) did not change significantly during shock and recovery but differed slightly from that in healthy individuals (0.5-1.1 nmol/l). CONCLUSIONS: Our bradykinin assay was successfully used to determine bradykinin concentrations in plasma samples. Intensive care unit patients with septic shock had low concentrations of plasma bradykinin during both shock and recovery phases.


Assuntos
Bradicinina/sangue , Choque Séptico/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Cromatografia Líquida , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espectrometria de Massas em Tandem
5.
Clin Chim Acta ; 482: 78-83, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29596816

RESUMO

BACKGROUND: Serotonin (5-hydroxytyramine) is a mediator of gastrointestinal smooth muscle contraction, and is secreted by neuroendocrine neoplasms (NENs). We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum serotonin to be used in NEN diagnostics and follow-up. METHODS: We used serum samples from healthy volunteers (n = 31) and patients suspected or monitored for NEN (n = 98). Serotonin-D4 internal standard was added to samples before solid phase extraction (SPE) and quantification by LC-MS/MS. The effects of sample handling and preparation on serotonin stability were studied. Finally, we established a provisional reference range for serum serotonin and compared our assay with serum 5-hydroxyindoleacetic acid (5-HIAA) for detection of NENs. RESULTS: Our assay is sensitive and has a wide linear range (10-10,000 nmol/l). Serum serotonin is stable for 7 days at room temperature and for 3 months at -20 °C. Sampling temperature is not critical. Normal range for serum serotonin was 270-1490 nmol/l. We found that serum serotonin and 5-HIAA performed equally well as diagnostic tests for NENs. CONCLUSIONS: Our LC-MS/MS assay for serum serotonin is well suited for clinical research and patient diagnostics. Our results confirm that it can complement 5-HIAA in diagnosis of NENs.


Assuntos
Ácido Hidroxi-Indolacético/sangue , Tumores Neuroendócrinos/diagnóstico , Serotonina/sangue , Cromatografia Líquida/métodos , Humanos , Tumores Neuroendócrinos/induzido quimicamente , Tumores Neuroendócrinos/metabolismo , Projetos Piloto , Valores de Referência , Serotonina/efeitos adversos , Serotonina/metabolismo , Extração em Fase Sólida , Manejo de Espécimes , Espectrometria de Massas em Tandem/métodos
6.
Clin Chim Acta ; 446: 206-12, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25896957

RESUMO

BACKGROUND: Urinary vanillylmandelic acid (VMA) is used to diagnose and monitor catecholamine secreting neuroendocrine tumors (NETs). We developed and validated a new liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for determination of serum VMA. METHODS: We used serum samples from healthy volunteers (n=314) and patients suspected for NET (n=36). Deuterated VMA as an internal standard was added to samples before solid phase extraction (SPE) and LC-MS/MS analysis. We studied the effects of sample storage, sampling device and a meal on serum VMA and metanephrine concentrations. Diurnal variation and age-dependent reference intervals were established. The diagnostic performance was compared with a urinary HPLC assay for VMA and metanephrines and a serum metanephrine LC-MS/MS assay. RESULTS: Serum VMA is stable at least for one day at +4°C, seven days at room temperature and 98 days at -20°C. Type of sampling device was not critical, but elevated serum VMA occurs after a meal (p = 0.031). Serum VMA increased with age. Therefore, we suggest clinical cut-off values of 62 nmol/L, 80 nmol/L and 108 nmol/L for age groups 18-50 yrs, 51-70 yrs and > 70 yrs, respectively. Comparison between a urinary VMA HPLC assay and serum VMA LC-MS/MS assay showed good correlation. CONCLUSIONS: Our LC-MS/MS assay is fast and sensitive and suits well for use in a clinical laboratory. Compared to 24-h urine collection our serum assay enables well controlled sampling and convenient preanalytical steps.


Assuntos
Adenoma/sangue , Neoplasias das Glândulas Suprarrenais/sangue , Bioensaio , Biomarcadores Tumorais/sangue , Neuroblastoma/sangue , Paraganglioma/sangue , Ácido Vanilmandélico/sangue , Adenoma/diagnóstico , Adenoma/urina , Adolescente , Neoplasias das Glândulas Suprarrenais/diagnóstico , Neoplasias das Glândulas Suprarrenais/urina , Adulto , Idoso , Biomarcadores Tumorais/urina , Estudos de Casos e Controles , Cromatografia Líquida , Feminino , Humanos , Masculino , Metanefrina/sangue , Metanefrina/urina , Pessoa de Meia-Idade , Neuroblastoma/diagnóstico , Neuroblastoma/urina , Paraganglioma/diagnóstico , Paraganglioma/urina , Valores de Referência , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem , Ácido Vanilmandélico/urina
7.
Ann Clin Biochem ; 52(Pt 4): 428-33, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25249663

RESUMO

INTRODUCTION: Dietary serotonin increases urinary secretion of 5-HIAA. A falsely elevated 5-HIAA may lead to incorrect suspicion of a neuroendocrine tumour. Therefore, we determined the effect and duration of dietary serotonin on serum 5-HIAA concentration. We also studied the distribution of 5-HIAA in serum fractions. METHODS: We used serum samples from healthy volunteers (31 women and four men). All test subjects avoided serotonin-containing foods for three days before sample collection. They then ate either pineapple, banana, kiwi fruit, tomato or walnuts and additional blood samples were taken after 2, 4, 6, 24, 48 and 72 h. To study the distribution of 5-HIAA in serum, samples from a healthy individual, a test person who had ingested walnuts, and from a neuroendocrine tumour patient were fractionated by gel filtration chromatography. The fractions were analysed for 5-HIAA. RESULTS: Serum 5-HIAA concentration increased significantly (P ≤ 0.001) within 2 h after ingestion of serotonin-containing food. After 2 h, 5-HIAA concentration started to decrease and reached the baseline concentration within 24 h. A calculated half-life of 5-HIAA in circulation was 1.3 h. In fractionated serum, 5-HIAA was found not only in free form but also in the albumin and α2-globulin fractions. CONCLUSIONS: The increase of serum 5-HIAA caused by dietary serotonin is significant but transient. Therefore, serotonin-containing foods should be avoided for one day before blood sampling. In serum, 5-HIAA is free and apparently bound to albumin. Minor amounts were also found in the α2-globulin fraction. Our liquid chromatography tandem mass spectrometry assay measures free 5-HIAA in serum.


Assuntos
Dieta , Ácido Hidroxi-Indolacético/sangue , Serotonina/administração & dosagem , Serotonina/metabolismo , Adulto , Idoso , Cromatografia Líquida , Feminino , Meia-Vida , Humanos , Masculino , Pessoa de Meia-Idade , Albumina Sérica , Albumina Sérica Humana , Soroglobulinas , Espectrometria de Massas em Tandem , Adulto Jovem
8.
Clin Chim Acta ; 428: 38-43, 2014 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-24211728

RESUMO

BACKGROUND: Serum 5-hydroxyindoleacetic acid (5-HIAA) could replace the determination of 24-h urinary 5-HIAA for diagnosis and follow-up of neuroendocrine tumors (NETs). We developed and validated a straightforward liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum 5-HIAA. METHODS: We used serum samples from healthy volunteers (n=136) and patients suspected or followed for NET (n=129). Samples were spiked with 5-HIAA-D2, extracted and quantified by LC-MS/MS. We studied the effects of sample storage, sample device, a meal and diurnal variation on serum 5-HIAA. Furthermore, we established a reference range for serum 5-HIAA and compared our assay with a urinary 5-HIAA HPLC assay and a commercial plasma chromogranin A (CgA) immunoassay. RESULTS: Our LC-MS/MS assay is sensitive (LOQ 5 nmol/L), has a wide assay range (5-10,000 nmol/L) and short analysis time (7 min). 5-HIAA in serum is stable for several days in various temperatures and during five freeze-thaw cycles. We found no diurnal variation (p ≥ 0.20) and a meal had no effect on serum 5-HIAA (p=0.89). We suggest an upper reference limit of 123 nmol/L for serum 5-HIAA. The area under curve (AUC) in receiver operator characteristics (ROC) analysis was 0.83 for urinary 5-HIAA, 0.81 for serum 5-HIAA and 0.76 for CgA, respectively. CONCLUSIONS: The LC-MS/MS assay for serum 5-HIAA discriminates between healthy individuals and patients with NET and is well suited for the diagnosis and follow-up of NETs.


Assuntos
Biomarcadores Tumorais/sangue , Ácido Hidroxi-Indolacético/sangue , Tumores Neuroendócrinos/sangue , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Tumores Neuroendócrinos/diagnóstico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA