Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38571291

RESUMO

AIMS: Same-day discharge (SDD) after atrial fibrillation (AF) ablation is an effective means to spare healthcare resources. However, safety remains a concern, and besides structural adaptations, SDD requires more efficient logistics and coordination. Therefore, in this study, we implement a streamlined, nurse-coordinated SDD programme following a standardized protocol. METHODS AND RESULTS: As a dedicated SDD coordinator, a nurse specialized in ambulatory cardiac interventions was in charge of the full SDD protocol, including eligibility, patient flow, in-hospital logistics, patient education, and discharge as well as early post-discharge follow-up by smartphone-based virtual visits. Patients planned for AF ablation were considered eligible if they had a left ventricular ejection fraction (LVEF) ≥35%, with basic support at home and accessibility of the hospital within 60 min also forming a part of the eligibility criteria. A total of 420 consecutive patients were screened by the SDD coordinator, of whom 331 were eligible for SDD. The reasons for exclusion were living remotely (29, 6.9%), lack of support at home (19, 4.5%), or LVEF <35% (17, 4.0%). Of the eligible patients, 300 (91%) were successfully discharged the same day. There were no major post-SDD complications. Rates of unplanned medical attention (19, 6.3%) and 30-day readmission (5, 1.6%) were extremely low and driven by femoral access-site complications. These were significantly reduced upon the introduction of compulsory ultrasound-guided punctures after the initial 150 SDD patients (P = 0.0145). Standardized SDD coordination resulted in efficient workflows and reduced the total workload of the medical staff. CONCLUSION: Same-day discharge after AF ablation following a nurse-coordinated standardized protocol is safe and efficient. The concept of ambulatory cardiac intervention nurses functioning as dedicated coordinators may be key in the future transition of hospitals to SDD. Ultrasound-guided femoral puncture virtually eliminated relevant femoral access-site complications in our cohort and should therefore be a prerequisite for SDD.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Alta do Paciente , Volume Sistólico , Assistência ao Convalescente , Função Ventricular Esquerda , Estudos Retrospectivos , Resultado do Tratamento
2.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37294671

RESUMO

AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120 ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80 ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 45(9): 1115-1123, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35583311

RESUMO

BACKGROUND: It is unknown whether His-Purkinje conduction system pacing (HPCSP), as either His bundle or left bundle branch pacing, could be an alternative to cardiac resynchronization therapy (BiVCRT) for patients with left ventricular dysfunction needing ventricular pacing due to atrioventricular block. The aim of the study is to compare the echocardiographic response and clinical improvement between HPCSP and BiVCRT. METHODS: Consecutive patients who successfully received HPCSP were compared with a historical cohort of BiVCRT patients. Patients were 1:1 matched by age, LVEF, atrial fibrillation, renal function and cardiomyopathy type. Responders were defined as patients who survived, did not require heart transplantation and increased LVEF ≥5 points at 6-month follow-up. RESULTS: HPCSP was successfully achieved in 92.5% (25/27) of patients. During follow-up, 8% (2/25) of HPCSP patients died and 4% (1/25) received a heart transplant, whereas 4% (1/25) of those in the BiVCRT cohort died. LVEF improvement was 10% ± 8% HPCSP versus 7% ± 5% BiVCRT (p = .24), and the percentage of responders was 76% (19/25) HPCSP versus 64% (16/25) BiVCRT (p = .33). Among survivors, the percentage of patients who improved from baseline II-IV mitral regurgitation (MR) to 0-I MR was 9/11 (82%) versus 2/8 (25%) (p = .02). Compared to those with BiVCRT, patients with HPCSP achieved better NYHA improvement: 1 point versus 0.5 (OR 0.34; p = .02). CONCLUSION: HPCSP in patients with LVEF ≤45% and atrioventricular block improved the LVEF and induced a response similar to that of BiVCRT. HPCSP significantly improved MR and NYHA functional class. HPCSP may be an alternative to BiVCRT in these patients. (Figure 1. Central Illustration). [Figure: see text].


Assuntos
Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular , Fascículo Atrioventricular , Doença do Sistema de Condução Cardíaco , Estimulação Cardíaca Artificial/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular/etiologia , Disfunção Ventricular/terapia , Função Ventricular Esquerda
4.
Pacing Clin Electrophysiol ; 45(3): 374-383, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35015308

RESUMO

BACKGROUND: His-Purkinje conduction system pacing (HPCSP) has been proposed as an alternative to Cardiac Resynchronization Therapy (CRT); however, predictors of echocardiographic response have not been described in this population. Septal flash (SF), a fast contraction and relaxation of the septum, is a marker of intraventricular dyssynchrony. METHODS: The study aimed to analyze whether HPCSP corrects SF in patients with CRT indication, and if correction of SF predicts echocardiographic response. This retrospective analysis of prospectively collected data included 30 patients. Left ventricular ejection fraction (LVEF) was measured with echocardiography at baseline and at 6-month follow-up. Echocardiographic response was defined as increase in five points in LVEF. RESULTS: HPCSP shortened QRS duration by 48 ± 21 ms and SF was significantly decreased (baseline 3.6 ± 2.2 mm vs. HPCSP 1.5 ± 1.5 mm p < .0001). At 6-month follow-up, mean LVEF improvement was 8.6% ± 8.7% and 64% of patients were responders. There was a significant correlation between SF correction and increased LVEF (r = .61, p = .004). A correction of ≥1.5 mm (baseline SF - paced SF) had a sensitivity of 81% and 80% specificity to predict echocardiographic response (area under the curve 0.856, p = .019). CONCLUSION: HPCSP improves intraventricular dyssynchrony and results in 64% echocardiographic responders at 6-month follow-up. Dyssynchrony improvement with SF correction may predict echocardiographic response at 6-month follow-up.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Estimulação Cardíaca Artificial , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Estudos Retrospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/prevenção & controle , Função Ventricular Esquerda
5.
Antimicrob Agents Chemother ; 65(10): e0252220, 2021 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-34252304

RESUMO

Abiotrophia and Granulicatella species are fastidious organisms, representing the causative agents of ∼1% to 3% of cases of infective endocarditis (IE). Little is known about the optimal antibiotic treatment for these species, and daptomycin has been suggested as a therapeutic option. We describe the antimicrobial profiles of Abiotrophia and Granulicatella IE isolates, investigate high-level daptomycin resistance (HLDR) development, and evaluate daptomycin activity in combination therapy. In vitro studies with 16 IE strains (6 Abiotrophia defectiva strains, 9 Granulicatella adiacens strains, and 1 G. elegans strain) were performed using microdilution to determine MICs and time-kill methodology to evaluate combination therapy. Daptomycin nonsusceptibility (DNS) (MIC ≥ 2 mg/liter) and HLDR (MIC ≥ 256 mg/liter) were based on existing Clinical and Laboratory Standards Institute (CLSI) breakpoints for viridans group streptococci. All isolates were susceptible to vancomycin: G. adiacens was more susceptible to penicillin and ampicillin than A. defectiva (22% versus 0% and 67% versus 33%) but less susceptible to ceftriaxone and daptomycin (56% versus 83% and 11% versus 50%). HLDR developed in both A. defectiva (33%) and G. adiacens (78%) after 24 h of exposure to daptomycin. Combination therapy did not prevent the development of daptomycin resistance with ampicillin (2/3 strains), gentamicin (2/3 strains), ceftriaxone (2/3 strains), or ceftaroline (2/3 strains). Once developed, HLDR was stable for a prolonged time (>3 weeks) in G. adiacens, whereas in A. defectiva, HLDR reversed to the baseline MIC at day 10. This study is the first to demonstrate rapid HLDR development in Abiotrophia and Granulicatella species in vitro. Resistance was stable, and most combination therapies did not prevent it.


Assuntos
Abiotrophia , Daptomicina , Endocardite Bacteriana , Antibacterianos/farmacologia , Carnobacteriaceae , Daptomicina/farmacologia , Endocardite Bacteriana/tratamento farmacológico , Humanos
6.
J Antimicrob Chemother ; 76(6): 1539-1546, 2021 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-33837406

RESUMO

OBJECTIVES: To investigate if the addition of cloxacillin to vancomycin enhances the activity of both monotherapies for treating MSSA and MRSA experimental endocarditis (EE) in rabbits. METHODS: Vancomycin plus cloxacillin was compared with the respective monotherapies and daptomycin. In vitro time-kill studies were performed using standard (105 cfu) and high (108 cfu) inocula of five MRSA, one glycopeptide-intermediate (GISA) and five MSSA strains. One MSSA (MSSA-678) and one MRSA (MRSA-277) strain were selected to be used in the in vivo model. A human-like pharmacokinetics model was applied and the equivalents of cloxacillin 2 g/4 h IV and daptomycin 6 mg/kg/day IV were administered. To optimize vancomycin activity, dosage was adjusted to achieve an AUC/MIC ≥400. RESULTS: Daptomycin sterilized significantly more vegetations than cloxacillin (13/13, 100% versus 9/15, 60%; P = 0.02) and showed a trend of better activity than vancomycin (10/14, 71%; P = 0.09) and vancomycin plus cloxacillin (10/14, 71%; P = 0.09) against MSSA-678. Addition of cloxacillin to vancomycin (13/15, 87%) was significantly more effective than vancomycin (8/16, 50%; P = 0.05) and showed similar activity to daptomycin (13/18, 72%; P = 0.6) against MRSA-277. In all treatment arms, the bacterial isolates recovered from vegetations were re-tested and showed the same daptomycin susceptibility as the original strains. CONCLUSIONS: Vancomycin plus cloxacillin proved synergistic and bactericidal activity against MRSA. Daptomycin was the most efficacious option against MSSA and similar to vancomycin plus cloxacillin against MRSA. In settings with high MRSA prevalence, vancomycin plus cloxacillin might be a good alternative for empirical therapy of S. aureus IE.


Assuntos
Daptomicina , Endocardite Bacteriana , Endocardite , Staphylococcus aureus Resistente à Meticilina , Animais , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Cloxacilina , Endocardite/tratamento farmacológico , Endocardite Bacteriana/tratamento farmacológico , Meticilina/farmacologia , Resistência a Meticilina , Testes de Sensibilidade Microbiana , Coelhos , Staphylococcus aureus , Vancomicina
7.
J Antimicrob Chemother ; 75(12): 3586-3592, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32853336

RESUMO

BACKGROUND: In vitro and in vivo activity of daptomycin alone or plus either cloxacillin or fosfomycin compared with cloxacillin alone and cloxacillin plus gentamicin were evaluated in a rabbit model of MSSA experimental endocarditis (EE). METHODS: Five MSSA strains were used in the in vitro time-kill studies at standard (105-106 cfu/mL) and high (108 cfu/mL) inocula. In the in vivo EE model, the following antibiotic combinations were evaluated: cloxacillin (2 g/4 h) alone or combined with gentamicin (1 mg/kg/8 h) or daptomycin (6 mg/kg once daily); and daptomycin (6 mg/kg/day) alone or combined with fosfomycin (2 g/6 h). RESULTS: At standard and high inocula, daptomycin plus fosfomycin or cloxacillin were bactericidal against 4/5 and 5/5 strains, respectively, while cloxacillin plus gentamicin was bactericidal against 3/5 strains at standard inocula but against none at high inocula. Fosfomycin, cloxacillin, gentamicin and daptomycin MIC/MBCs of the MSSA-678 strain used in the EE model were: 8/64, 0.25/0.5, 0.25/0.5 and 1/8 mg/L, respectively. Adding gentamicin to cloxacillin significantly reduced bacterial density in vegetations compared with cloxacillin monotherapy (P = 0.026). Adding fosfomycin or cloxacillin to daptomycin [10/11 (93%) and 8/11 (73%), respectively] significantly improved the efficacy of daptomycin in sterilizing vegetations [0/11 (0%), P < 0.001 for both combinations] and showed better activity than cloxacillin alone [0/10 (0%), P < 0.001 for both combinations] and cloxacillin plus gentamicin [3/10 (30%), P = 0.086 for cloxacillin plus daptomycin and P = 0.008 for fosfomycin plus daptomycin]. No recovered isolates showed increased daptomycin MIC. CONCLUSIONS: The addition of cloxacillin or fosfomycin to daptomycin is synergistic and rapidly bactericidal, showing better activity than cloxacillin plus gentamicin for treating MSSA EE, supporting their clinical use.


Assuntos
Daptomicina , Endocardite Bacteriana , Endocardite , Fosfomicina , Animais , Antibacterianos/uso terapêutico , Cloxacilina , Endocardite/tratamento farmacológico , Endocardite Bacteriana/tratamento farmacológico , Gentamicinas , Testes de Sensibilidade Microbiana , Coelhos
8.
J Cardiovasc Electrophysiol ; 31(4): 868-874, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31967367

RESUMO

BACKGROUND: Micra transcatheter pacemaker system (TPS) usually achieves low implant pacing threshold (IPT). However, IPT may increase in some patients during follow-up. AIM: To apply implant parameters in predicting long-term occurrence of very high pacing threshold (VHPT) in patients with Micra-TPS. METHODS: A cohort of 110 consecutive patients implanted with a Micra-TPS from 2014 to 2018 was evaluated at discharge and at 1, 12, 24, 36, and 48 months follow-up. VHPT was defined as greater than 2 V/0.24 ms. VHPT predictors were identified. RESULTS: Micra-TPS was implanted successfully in 108 patients (98.2%). During a mean follow-up of 24 ± 16 months, 18 patients (16.7%) died of causes nonpacemaker-related, and 4 (3.8%) developed VHPT. Patients with VHPT had higher IPT and lower implant impedance than patients with non-VHPT: 1 ± 0.31 vs 0.55 ± 0.29 V/0.24 ms (P = .003) and 580 ± 59 vs 837 ± 232 Ω (P = .03), respectively. IPT and impedance had excellent discriminative power to predict VHPT (area under the curve: 0.85 ± 0.07 and 0.91 ± 0.05, respectively). Negative predictive value (NPV) of IPT ≤ 0.5 V/0.24 ms was 100%; positive predictive value (PPV) was 8% throughout follow-up. Implant impedance ≤ 600 Ω had NPV of 99% throughout follow-up, whereas PPV varied: 16%, 21%, 16%, and 28% at 1, 12, 24, and 36 months, respectively. Sequential combination of IPT greater than 0.5 V/0.24 ms and impedance ≤ 600 Ω improved PPV to 25%, 35%, 27%, and 44%, respectively, whereas NPV remained 99% throughout follow-up. CONCLUSION: Despite favorable long-term electrical performance of Micra-TPS, a small percent of patients developed VHPT during follow-up. A sequential combination of IPT and impedance could allow the implanter to identify patients who will develop VHPT during long-term follow-up.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Impedância Elétrica , Fontes de Energia Elétrica , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
9.
Europace ; 22(9): 1391-1400, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32898254

RESUMO

AIMS: Sudden cardiac death (SCD) risk estimation in patients referred for cardiac resynchronization therapy (CRT) remains a challenge. By CRT-mediated improvement of left ventricular ejection fraction (LVEF), many patients loose indication for primary prevention implantable cardioverter-defibrillator (ICD). Increasing evidence shows the importance of myocardial scar for risk prediction. The aim of this study was to investigate the prognostic impact of myocardial scar depending on the echocardiographic response in patients undergoing CRT. METHODS AND RESULTS: Patients with indication for CRT were prospectively enrolled. Decision about ICD or pacemaker implantation was based on clinical criteria. All patients underwent delayed-enhancement cardiac magnetic resonance imaging. Median follow-up duration was 45 (24-75) months. Primary outcome was a composite of sustained ventricular arrhythmia, appropriate ICD therapy, or SCD. A total of 218 patients with LVEF 25.5 ± 6.6% were analysed [158 (73%) male, 64.9 ± 10.7 years]. Myocardial scar was observed in 73 patients with ischaemic cardiomyopathy (ICM) (95% of ICM patients); in 62 with non-ischaemic cardiomyopathy (45% of these patients); and in all but 1 of 36 (17%) patients who reached the primary outcome. Myocardial scar was the only significant predictor of primary outcome [odds ratio 27.7 (3.8-202.7)], independent of echocardiographic CRT response. A total of 55 (25%) patients died from any cause or received heart transplant. For overall survival, only a combination of the absence of myocardial scar with CRT response was associated with favourable outcome. CONCLUSION: Malignant arrhythmic events and SCD depend on the presence of myocardial scar but not on CRT response. All-cause mortality improved only with the combined absence of myocardial scar and CRT response.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Arritmias Cardíacas , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/terapia , Humanos , Masculino , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
10.
Europace ; 22(4): 598-606, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32101605

RESUMO

AIMS: Ventricular tachycardia (VT) substrate-based ablation has become a standard procedure. Electroanatomical mapping (EAM) detects scar tissue heterogeneity and define conduction channels (CCs) that are the ablation target. Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) is able to depict CCs and increase ablation success. Most patients undergoing VT ablation have an implantable cardioverter-defibrillator (ICD) that can cause image artefacts in LGE-CMR. Recently wideband (WB) LGE-CMR sequence has demonstrated to decrease these artefacts. The aim of this study is to analyse accuracy of WB-LGE-CMR in identifying the CC entrances. METHODS AND RESULTS: Thirteen consecutive ICD-patients who underwent VT ablation after WB-LGE-CMR were included. Number and location of CC entrances in three-dimensional EAM and in WB-LGE-CMR reconstruction were compared. Concordance was compared with a historical cohort matched by cardiomyopathy, scar location, and age (26 patients) with LGE-CMR prior to ICD and VT ablation. In WB-CMR group, 101 and 93 CC entrances were identified in EAM and WB-LGE-CMR, respectively. In historical cohort, 179 CC entrances were identified in both EAM and LGE-CMR. The EAM/CMR concordance was 85.1% and 92.2% in the WB and historical group, respectively (P = 0.66). There were no differences in false-positive rate (CC entrances detected in CMR and absent in EAM: 7.5% vs 7.8% in WB vs. conventional CMR, P = 0.92) nor in false-negative rate (CC entrances present in EAM not detected in CMR: 14.9% vs.7.8% in WB vs. conventional CMR, P = 0.23). Epicardial CCs was predictor of poor CMR/EAM concordance (OR 2.15, P = 0.031). CONCLUSION: Use of WB-LGE-CMR sequence in ICD-patients allows adequate VT substrate characterization to guide VT ablation with similar accuracy than conventional LGE-CMR in patients without an ICD.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia
11.
Europace ; 21(5): 724-731, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30649273

RESUMO

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) may define left atrial (LA) anatomy and structural remodelling, and facilitate atrial fibrillation (AF) ablation. We aimed to assess the intra- and inter-observer reproducibility and agreement of LGE-CMR parameters with direct application to AF ablation techniques. METHODS AND RESULTS: One experienced and one non-experienced observer performed complete LGE-CMR data analysis twice, on different days, in 40 randomly selected LGE-CMR examinations [20 performed before ablation (pre-ablation) and 20 performed 3 months after ablation (post-ablation)]. Four additional observers (two experienced and two non-experienced) performed complete LGE-CMR data analysis in a subgroup of 30 patients (15 pre-ablation and 15 post-ablation). All LGE-CMR were performed in sinus rhythm. Intra- and inter-observer reproducibility of LA volume, LA area, and sphericity index (SI) was high: coefficient of variation <10% and intraclass correlation coefficient >0.71. Geometric congruency of repeated reconstruction of LA shape was high: maximal error <5 mm for intra-observer and <8 mm for inter-observer. The precision of scar location increased with extent of scar, and was high (Dice coefficient >0.75) when the scar area was >5 cm2 for a single observer and >15 cm2 for multiple observers. Non-experienced observers performed equally well to experienced observers. CONCLUSION: Late gadolinium enhancement cardiac magnetic resonance measurements of LA area, volume, and SI were reproducible, and geometric congruency of LA shape was high. Location of scar was precise for scar areas >5 cm2 for single observers and >15 cm2 for multiple observers, regardless of the observers' experience. These results may serve as a reference for future studies on the role for substrate-based AF ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter/métodos , Gadolínio/farmacologia , Átrios do Coração , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Remodelamento Atrial , Meios de Contraste/farmacologia , Feminino , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Reprodutibilidade dos Testes
12.
Clin Infect Dis ; 66(1): 104-111, 2018 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-29020360

RESUMO

Background: Infective endocarditis (IE) caused by Abiotrophia (ABI) and Granulicatella (GRA) species is poorly studied. This work aims to describe and compare the main features of ABI and GRA IE. Methods: We performed a retrospective study of 12 IE institutional cases of GRA or ABI and of 64 cases published in the literature (overall, 38 ABI and 38 GRA IE cases). Results: ABI/GRA IE represented 1.51% of IE cases in our institution between 2000 and 2015, compared to 0.88% of HACEK (Haemophilus, Aggregatibacter, Cardiobacterium, Eikenella, Kingella)-related IE and 16.62% of Viridans group streptococci (VGS) IE. Institutional ABI/GRA IE case characteristics were comparable to that of VGS, but periannular complications were more frequent (P = .008). Congenital heart disease was reported in 4 (10.5%) ABI and in 11 (28.9%) GRA cases (P = .04). Mitral valve was more frequently involved in ABI than in GRA (P < .001). Patient sex, prosthetic IE, aortic involvement, penicillin susceptibility, and surgical treatment were comparable between the genera. New-onset heart failure was the most frequent complication without genera differences (P = .21). Five (13.2%) ABI patients and 2 (5.3%) GRA patients died (P = .23). Factors associated with higher mortality were age (P = .02) and new-onset heart failure (P = .02). The genus (GRA vs ABI) was not associated with higher mortality (P = .23). Conclusions: GRA/ABI IE was more prevalent than HACEK IE and approximately one-tenth as prevalent as VGS; periannular complications were more frequent. GRA and ABI genera IE presented similar clinical features and outcomes. Overall mortality was low, and related to age and development of heart failure.


Assuntos
Abiotrophia/isolamento & purificação , Carnobacteriaceae/isolamento & purificação , Endocardite/epidemiologia , Endocardite/patologia , Infecções por Bactérias Gram-Positivas/epidemiologia , Infecções por Bactérias Gram-Positivas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Endocardite/microbiologia , Endocardite/mortalidade , Feminino , Infecções por Bactérias Gram-Positivas/microbiologia , Infecções por Bactérias Gram-Positivas/mortalidade , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento
13.
Clin Infect Dis ; 66(8): 1286-1289, 2018 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-29136121

RESUMO

Intravenous thrombolysis is contraindicated in acute ischemic stroke secondary to infective endocarditis. We report our initial experience in 6 cases of proximal vessel occlusion treated with mechanical thrombectomy, which was safe (no bleeding) and effective (significant early neurological improvement) and might be useful in this clinical setting.


Assuntos
Isquemia Encefálica/cirurgia , Endocardite Bacteriana/cirurgia , Endocardite/cirurgia , Acidente Vascular Cerebral/cirurgia , Administração Intravenosa , Idoso , Isquemia Encefálica/complicações , Endocardite/complicações , Endocardite Bacteriana/complicações , Feminino , Humanos , Masculino , Trombólise Mecânica , Pessoa de Meia-Idade , Acidente Vascular Cerebral/complicações , Trombectomia
14.
Artigo em Inglês | MEDLINE | ID: mdl-29610194

RESUMO

We investigated whether the addition of fosfomycin or cloxacillin to daptomycin provides better outcomes in the treatment of methicillin-resistant Staphylococcus aureus (MRSA) experimental aortic endocarditis in rabbits. Five MRSA strains were used to perform in vitro time-kill studies using standard (106) and high (108) inocula. Combined therapy was compared to daptomycin monotherapy treatment in the MRSA experimental endocarditis model. A human-like pharmacokinetics model was applied, and the equivalents of cloxacillin at 2 g/4 h, fosfomycin at 2 g/6 h, and daptomycin at 6 to 10 mg/kg/day were administered intravenously. A combination of daptomycin and either fosfomycin or cloxacillin was synergistic in the five strains tested at both inocula. A bactericidal effect was detected in four of five strains tested with both combinations. The MRSA-277 strain (vancomycin MIC, 2 µg/ml) was used for the experimental endocarditis model. Daptomycin plus fosfomycin significantly improved the efficacy of daptomycin monotherapy at 6 mg/kg/day in terms of both the proportion of sterile vegetations (100% versus 72%, P = 0.046) and the decrease in the density of bacteria within the vegetations (P = 0.025). Daptomycin plus fosfomycin was as effective as daptomycin monotherapy at 10 mg/kg/day (100% versus 93%, P = 1.00) and had activity similar to that of daptomycin plus cloxacillin when daptomycin was administered at 6 mg/kg/day (100% versus 88%, P = 0.48). Daptomycin nonsusceptibility was not detected in any of the isolates recovered from vegetations. In conclusion, for the treatment of MRSA experimental endocarditis, the combination of daptomycin plus fosfomycin showed synergistic and bactericidal activity.


Assuntos
Antibacterianos/uso terapêutico , Daptomicina/uso terapêutico , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/microbiologia , Fosfomicina/uso terapêutico , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Animais , Antibacterianos/farmacocinética , Cloxacilina/farmacocinética , Cloxacilina/uso terapêutico , Daptomicina/farmacocinética , Sinergismo Farmacológico , Feminino , Fosfomicina/farmacocinética , Humanos , Coelhos
15.
J Cardiovasc Electrophysiol ; 29(8): 1065-1072, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29722466

RESUMO

INTRODUCTION: The purpose of this study was to compare the anatomical characteristics of scar formation achieved by visual-guided laser balloon (Laser) and radiofrequency (RF) pulmonary vein isolation (PVI), using late-gadolinium-enhanced cardiac magnetic resonance imaging (LGE-CMR). METHODS AND RESULTS: We included 17 patients with paroxysmal or early persistent drug resistant AF who underwent Laser ablation; 2 were excluded due to procedure-related complications. The sample was matched with a historical group of 15 patients who underwent PVI using RF. LGE-CMR sequences were acquired before and 3 months post-PVI. Ablation gaps were defined as pulmonary vein (PV) perimeter sections showing no gadolinium enhancement. The number of ablation gaps was lower in Laser versus RF ablations (median 7 vs. 14, P  =  0.015). Complete anatomical PVI (circumferential scar around PV, without gaps) was more frequently achieved with Laser than with RF (39% vs. 19% of PVs, P  =  0.025). Fewer gaps were present at the superior and anterior left PV and posterior right PV antral regions in the Laser group, compared to RF. Scar extension into the PVs was similar in both groups, although RF produced more extensive ablation scar toward the LA body. AF recurrences at 1 year were similar in both groups (Laser 36% vs. RF 27%, P  =  1.00). CONCLUSIONS: Compared to RF, Laser ablation achieved more complete anatomical PVI, with less LA scar extension. However, AF recurrence appears to be similar after Laser compared to RF ablation. Further studies are needed to assess whether the anatomical advantages of Laser ablation translate into clinical benefit in patients with AF.


Assuntos
Gadolínio , Imagem Cinética por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Ablação por Radiofrequência/tendências , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Coortes , Feminino , Seguimentos , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/tendências , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/efeitos adversos
16.
Europace ; 20(2): 337-346, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28017938

RESUMO

Aims: Identification of local abnormal electrograms (EGMs) during ventricular tachycardia substrate ablation (VTSA) is challenging when they are hidden within the far-field signal. This study analyses whether the response to a double ventricular extrastimulus during substrate mapping could identify slow conducting areas that are hidden during sinus rhythm. Methods and results: Consecutive patients (n = 37) undergoing VTSA were prospectively included. Bipolar EGMs with >3 deflections and duration <133 ms were considered as potential hidden slow conduction EGMs (HSC-EGM) if located within/surrounding the scar area. Whenever a potential HSC-EGM was identified, a double ventricular extrastimulus was delivered. If the local potential delayed, it was annotated as HSC-EGM. The incidence of HSC-EGM in core, border-zone, and normal-voltage regions was determined. Ablation was delivered at conducting channel entrances and HSC-EGMs. VT inducibility after VTSA obtained was compared with data from a historic control group. 2417 EGMs were analyzed. 575 (23.7%) qualified as potential HSC-EGM, and 198 of them were tagged as HSC-EGMs. Scars in patients with HSC-EGMs (n = 21, 56.7%) were smaller (35.424.7 vs 67.639.1 cm2; P = 0.006) and more heterogeneous (core/scar area ratio 0.250.2 vs 0.450.19; P = 0.02). 28.8% of HSC-EGMs were located in normal-voltage tissue; 81.3% were targeted for ablation. Patients undergoing VTSA incorporating HSC analysis needed less radiofrequency time (17.411 vs 2310.7 minutes; P = 0.016) and had a lower rate of VT inducibility after VTSA than the historic controls (24.3% vs 50%; P = 0.018). Conclusion: Ventricular tachycardia substrate ablation incorporating HSC analysis allowed further arrhythmic substrate identification (especially in normal-voltage areas) and reduced RF time and VT inducibility after VTSA.


Assuntos
Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Taquicardia Ventricular/diagnóstico , Potenciais de Ação , Idoso , Ablação por Cateter , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento
17.
Eur J Oral Sci ; 126(4): 307-315, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29972599

RESUMO

In-vitro studies suggest that electromagnetic interference can occur under specific conditions involving proximity between electronic dental equipment and pacemakers. At present, in-vivo investigations to verify the effect of using electronic dental equipment in clinical conditions on patients with pacemakers are scarce. This study aimed to evaluate, in vivo, the effect of three commonly used electronic dental instruments - ultrasonic dental scaler, electric pulp tester, and electronic apex locator - on patients with different pacemaker brands and configurations. Sixty-six consecutive non-pacemaker-dependent patients were enrolled during regular electrophysiology follow-up visits. Electronic dental tools were operated while the pacemaker was interrogated, and the intracardiac electrogram and electrocardiogram were recorded. No interferences were detected in the intracardiac electrogram of any patient during the tests with dental equipment. No abnormalities in pacemaker pacing and sensing function were observed, and no differences were found with respect to the variables, pacemaker brands, pacemaker configuration, or mode of application of the dental equipment. Electromagnetic interferences affecting the surface electrocardiogram, but not the intracardiac electrogram, were found in 25 (37.9%) patients, especially while using the ultrasonic dental scaler; the intrinsic function of the pacemakers was not affected. Under real clinical conditions, none of the electronic dental instruments tested interfered with pacemaker function.


Assuntos
Equipamentos Odontológicos , Análise de Falha de Equipamento , Marca-Passo Artificial , Idoso , Teste da Polpa Dentária/instrumentação , Raspagem Dentária/instrumentação , Campos Eletromagnéticos , Desenho de Equipamento , Feminino , Humanos , Masculino , Odontometria/métodos , Espanha , Ápice Dentário/anatomia & histologia
18.
Europace ; 19(6): 976-982, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27353322

RESUMO

AIMS: This study assessed the benefit of peri-implantable cardioverter-defibrillator implant ventricular tachycardia (VT)-substrate ablation in patients with structural heart disease (SHD). METHODS AND RESULTS: Patients with SHD and indication for secondary prevention ICD implant were prospectively included. Patients presenting with incessant and/or slow VT or frequent (≥2) VT episodes who underwent peri-ICD VT-substrate ablation (the scar dechannelling technique) were compared with those who received ICD alone and did not meet ablation criteria. The primary endpoint was any sustained VT/ICD therapy during follow-up. Of 206 patients included (43.2% non-ischaemic), 70 were assigned to ablation and 136 received ICD implant alone. During a mean follow-up of 45.6 ± 24.7 months, the primary endpoint was more frequent in the non-ablation group (47.1 vs. 22.9%; P< 0.0001). Higher VT recurrence-free survival rate [log-rank P= 0.001; HR = 0.42 (0.24-0.73), P= 0.002] and ICD shock-free survival rate [log-rank P= 0.007; HR = 0.36 (0.17-0.78); P = 0.01] were observed in the ablation group. Higher relative risk reduction was observed in ischaemic [HR = 0.38 (0.18-0.83); P = 0.015] vs. non-ischaemic patients [HR = 0.49 (0.23-1.01); P = 0.08]. Patients with left ventricular ejection fraction (LVEF) <35% showed no differences in VT recurrence between treatment groups (log-rank P = 0.213) although VT burden during follow-up was lower in the ablation group [median (interquartile range) 1 (1-3) vs. 4 (1-10) VT episodes; P = 0.05]. CONCLUSION: First-line peri-ICD implant VT-substrate ablation was associated with decreased VT recurrence and ICD shocks during long-term follow-up in patients with SHD and indication for secondary prevention ICD implant, especially in ischaemic patients. In patients with LVEF <35%, no benefit was observed in terms of VT recurrence-free survival, although VT burden during follow-up was lower in the ablation group.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Secundária/instrumentação , Taquicardia Ventricular/terapia , Idoso , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Terapia Combinada , Intervalo Livre de Doença , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Prospectivos , Recidiva , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
20.
Europace ; 18(2): 232-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25883077

RESUMO

AIMS: Matrix metalloproteinases (MMPs) and their tissue inhibitors (TIMPs) are involved in cardiac remodelling. Available information regarding their prognostic utility in heart failure (HF) and cardiac resynchronization therapy (CRT) is controversial. The aim of this study was to analyse MMP-2 and TIMP-1 levels as predictors of long-term mortality in HF patients treated with CRT. METHODS AND RESULTS: We prospectively included 42 consecutive patients with successfully implanted CRT. Matrix metalloproteinase-2 and TIMP-1 assays were performed prior to implant. Patients were evaluated at baseline and at the outpatient clinic at 6-month intervals. Clinical response, left ventricular (LV) remodelling, and mortality were analysed. During a mean follow-up of 60 ± 34 months, long-term mortality from any cause was 36% (15 patients). The cause of death was end stage of HF in 12 patients, sudden death in 2 patients, and 1 unknown. After adjustment using a Cox regression model, the independent predictors of long-term mortality were baseline TIMP-1, hazard ratio (HR) 1.18 (95% confidence interval (95% CI) [1.05-1.33], P = 0.007), baseline glomerular filtration rate (GFR), HR 0.97 (95% CI [0.94-1.00], P = 0.05), and permanent atrial fibrillation (AF), HR 3.14 (95% CI [1.02-9.67], P = 0.04). Area under receiver operating characteristic curve for TIMP-1 was 0.79 (95% CI [0.63-0.94]). Tissue inhibitor of matrix metalloproteinase-1 ≥ 248 ng/mL predicts mortality with 80% sensitivity and 71% specificity. CONCLUSION: Tissue inhibitor of matrix metalloproteinase-1 is a powerful predictor of long-term mortality in HF patients treated with CRT.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Inibidor Tecidual de Metaloproteinase-1/sangue , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Área Sob a Curva , Biomarcadores/sangue , Terapia de Ressincronização Cardíaca/efeitos adversos , Causas de Morte , Intervalo Livre de Doença , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Humanos , Estimativa de Kaplan-Meier , Masculino , Metaloproteinase 2 da Matriz/sangue , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Curva ROC , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA